首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Choi HN  Cho SH  Lee WY 《Analytical chemistry》2003,75(16):4250-4256
Electrochemical behavior and electrogenerated chemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+)) immobilized in sol-gel-derived titania TiO2)-Nafion composite films coated on a glassy carbon electrode have been investigated. The electroactivity of Ru(bpy)3(2+) ion exchanged into the composite films and its ECL behavior were strongly dependent upon the amount of Nafion incorporated into the TiO2-Nafion composite films. The ECL sensor of Ru(bpy)32+ immobilized in a TiO2-Nafion composite with 50% Nafion content showed the maximum ECL intensities for both tripropylamine (TPA) and sodium oxalate in 0.05 M phosphate buffer solution at pH 7. Detection limits were 0.1 microM for TPA and 1.0 microM for oxalate (S/N = 3) with a linear range of 3 orders of magnitude in concentration. The present ECL sensor showed improved ECL sensitivity and long-term stability, as compared to the ECL sensors based on pure Nafion films. The present Ru(bpy)3(2+) ECL sensor based on TiO2-Nafion (50%) composite films was applied as an HPLC detector for the determination of erythromycin in human urine samples. The present Ru(bpy)3(2+) ECL sensor was stable in the mobile phase containing a high content of organic solvent (30%, v/v), in contrast to a pure Nafion-based Ru(bpy)3(2+) ECL sensor. The detection limit for erythromycin was 1.0 microM, with a linear range of 3 orders of magnitude in concentration.  相似文献   

2.
The voltammetry and electrogenerated chemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3 2+) ion-exchanged in Nafion and Nafion-silica composite materials have been investigated. The major goal of this work was to investigate and develop new materials and immobilization approaches for the fabrication of ECL-based sensors with improved reactivity and long-term stability. Nation-silica composite materials with varying contents of Nation (53-100 wt% relative to silica) were prepared via the two-step acid/base hydrolysis and condensation of tetramethoxysilane. The Nafion doped sols were spin cast on glassy carbon electrodes, dried, and then ion-exchanged with Ru(bpy)3 2+. The shapes of the cyclic voltammetric curves and the amount of Ru(bpy)3 2+ exchanged into the films strongly depends on the amount of Nafion incorporated into the hybrid sol. Nafion-silica films with a low content of Nafion ion-exchanged less Ru(bpy)3 2+ and exhibited tail-shaped voltammetry at 100 mV/s. The ECL of immobilized Ru(bpy)3 2+ in the presence of either tripropylamine or sodium oxalate in pH 5 acetate buffer was also strongly dependent on the amount of Nafion introduced into the composite with greater ECL observed for the Nafion-silica films relative to pure Nafion.  相似文献   

3.
The development of a detection method based on the electrogenerated chemiluminescence of tris(2,2'-bipyridine)ruthenium(II), (Ru(bpy)3(2+], immobilized in a Nafion film coated on an electrode is discussed. Control of the electrode potential controls creation of the reactive reagent Ru(bpy)3(3+) which reacts with certain analytes to yield chemiluminescence emission of intensity proportional to the analyte concentration. The reaction results in Ru(bpy)3(3+) being converted to Ru(bpy)3(2+), which then is recycled to Ru(bpy)3(3+) again at the electrode. This sensor has been used in flow injection to determine oxalate, alkylamines, and NADH. Detection limits are 1 microM, 10 nM, and 1 microM, respectively, with working ranges extending over 4 decades in concentration. Sensitivity is constant over the wide pH range from 3 to 10. With oxalate, and to a small extent with amines, emission intensities increase with increasing ionic strength; this was shown to be a phenomenon related to the Nafion film and not to the chemiluminescence reaction. Emission intensities increase with temperature. The sensor remains stable for several days with suitable storage conditions. Significant amounts of Ru(bpy)3(3+) are shown to be capable of storage within the film.  相似文献   

4.
2-(2-Aminoethyl)-1-methylpyrrolidine and N-(3-aminopropyl)pyrrolidine (NAPP) were found to be selective and sensitive derivatization reagents for carboxylic acid by high-performance liquid chromatography (HPLC) with electrogenerated chemiluminescence detection using tris(2,2'-bipyridine)ruthenium(II). Free fatty acids and ibuprofen were used as model compounds of carboxylic acids, and the derivatization conditions were optimized with myristic acid as a representative of free fatty acids. All the fatty acids tested were reacted with NAPP to produce highly sensitive derivatives under the mild reaction conditions of room temperature for 30 min in acetonitrile containing 2-bromo-1-ethylpyridinium tetrafluoroborate and 9-methyl-3,4-dihydro-2H-pyrido[1,2-a]pyrimidin-2-one. The chemiluminescence intensities were similar for all fatty acids. The derivatives obtained from 10 free fatty acids were completely separated by reversed-phase chromatography under isocratic elution conditions. The on-column detection limits (signal-to-noise ratio of 3) with proposed HPLC separation and chemiluminescence detection were 70 and 45 fmol for myristic acid and ibuprofen, respectively. The free fatty acids in human plasma were successfully determined using the present method. Histamine, a model compound of primary amines, was also determined after precolumn derivatization with 3-(diethylamino)propionic acid at room temperature for 60 min in acetonitrile containing N,N'-dicyclohexylcarbodiimide and 3,4-dihydro-3-hydroxy-4-oxo-1,2,3-benzotriazine with the detection limit of 70 fmol.  相似文献   

5.
The effects of nonionic surfactant chain length on the properties of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+) where bpy = 2,2'-bipyridine) electrochemiluminescence (ECL) have been investigated. The electrochemistry, photophysics, and ECL of Ru(bpy)3(2+) in the presence of a series of nonionic surfactants are reported (Triton X-100, 114, 165, 405, 305, and 705-70). These surfactants differ in the number of poly(ethylene oxide) units incorporated into the surfactant molecule. The anodic oxidation of Ru(bpy)3(2+) produces ECL in the presence of tri-n-propylamine (TPrA) in aqueous surfactant solution. Increases in ECL efficiency (> or = 5-fold) and TPrA oxidation current (> or = 2-fold) have been observed in surfactant media. Slight decreases in ECL intensity are observed as the chain length of the nonionic surfactant increases. The data supports adsorption of surfactant on the electrode surface, thus facilitating TPrA and Ru(bpy)3(2+) oxidation and leading to higher ECL efficiencies.  相似文献   

6.
Tris(2,2'-bipyridyl)ruthenium can be excited to fluorescence by visible light (lambda abs 454 nm, lambda em 607 nm) when in the M(II) oxidation state, but not in the M(III) state. A novel chromatographic detection method using the non-fluorescent M(III) form of the complex as a postcolumn fluorogenic reagent is demonstrated. The M(III) form is a powerful oxidizing agent (E degree = 1.27 V vs NHE, 1.05 V vs Ag/AgCl). The M(III) reagent is generated on-line from the M(II) form of the complex by a highly efficient porous carbon electrode and then reacted briefly with chromatographic effluent; the M(II) created by electron transfer from oxidation-susceptible analytes is then detected by fluorescence. The fluorescence detector can be calibrated for number of electrons transferred by injection of either M(II) or an oxidative standard such as ferrocyanide. It is hoped that this redox-based detection scheme will provide an alternative to electrochemical detection. Among the advantages are freedom from surface fouling and the potential for extremely low detection limits. The scheme was applied to detection of the peptide dynorphin A and several of its fragments. Dynorphin A contains tyrosine at the N-terminus (position 1) and tryptophan in position 15; these amino acid residues are susceptible to oxidation and peptides containing them can be detected on that basis. Flow injection testing of the model compounds Tyr-Gly-Gly-Phe-Leu and Gly-Gly-Trp-Gly indicated that tyrosine transferred approximately 1 electron to the M(III) reagent and that tryptophan transferred approximately 4 electrons. Similar results were obtained from the chromatographic runs. Dynorphin A and six dynorphin A fragments containing the N-terminal tyrosine were detected easily at 100 nM concentration (14 pmol) using laser-induced fluorescence. As expected, one fragment that did not contain tryptophan or tyrosine was not detected. A mass detection limit of 80 fmol was estimated for the tyrosine-containing fragments.  相似文献   

7.
The electrochemistry and electrogenerated chemiluminescence (ECL) of Ru(bpy)3(2+) (bpy = 2,2'-bipyridyl) were studied in the presence of the nonionic surfactants Triton X-100, Thesit, and Nonidet P40. The anodic oxidation of Ru(bpy)3(2+) produces ECL in the presence of tri-n-propylamine in both aqueous and surfactant solutions. Increases in both ECL efficiency (> or =8-fold) and duration of the ECL signal were observed in surfactant media. A shift to lower energies of the Ru(bpy)3(2+) ECL emission by approximately 8 nm was also observed. The one-electron oxidation of Ru(bpy)3(2+) to Ru(bpy)3(3t) occurs at + 1.03 V vs Ag/AgCl in aqueous buffered (0.2 M potassium phosphate) solution as found by square wave voltammetry. This potential did not shift in surfactant systems, indicating that the redshifts in ECL emission are due to stabilization of ligand pi* orbitals in the metal-to-ligand charge-transfer excited state. These results are consistent with hydrophobic interactions between Ru(bpy)3(2+) and the nonionic surfactants.  相似文献   

8.
Shi L  Liu X  Li H  Xu G 《Analytical chemistry》2006,78(20):7330-7334
A sensitive electrochemiluminescent detection scheme by solid-phase extraction at Ru(bpy)3(2+)-modified ceramic carbon electrodes (CCEs) was developed. The as-prepared Ru(bpy)3(2+)-modified CCEs show much better long-term stability than other Nafion-based Ru(bpy)3(2+)-modified electrodes and enjoy the inherent advantages of CCEs. The log-log calibration plot for dioxopromethazine is linear from 1.0 x 10(-9) to 1.0 x 10(-4) mol L(-1) using the new detection scheme. The detection limit is 6.6 x 10(-10) mol L(-1) at a signal-to-noise ratio of 3. The new scheme improves the sensitivity by approximately 3 orders of magnitude, which is the most sensitive Ru(bpy)3(2+) ECL method. The scheme allows the detection of dioxopromethazine in a urine sample within 3 min. Since Ru(bpy)3(2+) ECL is a powerful technique for determination of numerous amine-containing substances, the new detection scheme holds great promise in measurement of free concentrations, investigation of protein-drug interactions and DNA-drug interactions, pharmaceutical analysis, and so on.  相似文献   

9.
Liposomes ( approximately 100-nm diameter) containing Ru(bpy)32+ (bpy = 2,2'-bipyridine) were prepared as an electrogenerated chemiluminescent (ECL) tag for a sandwich-type immunoassay of human C-reactive protein (CRP). Polyclonal human CRP antibodies were introduced onto liposomes and magnetic beads through biotin-streptavidin interaction. The antigen-antibody conjugates formed on addition of a CRP-containing sample were separated from unreacted species magnetically. Addition of 0.1 M tri-n-propylamine and 0.1 M phosphate buffer (pH 7.6) containing 0.1 M NaCl and 1% (v/v) Triton X-100 caused liberation of the Ru(bpy)32+ from the liposome. ECL obtained in this medium showed a detection limit of 100 ng/mL for human CRP with good linearity of ECL intensity versus antigen concentration over the range 100 ng/mL-10 microg/mL.  相似文献   

10.
Liu J  Yan J  Yang X  Wang E 《Analytical chemistry》2003,75(14):3637-3642
The design and performance of a miniaturized chip-type tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)3(2+)] electrochemiluminescence (ECL) detection cell suitable for both capillary electrophoresis (CE) and flow injection (FI) analysis are described. The cell was fabricated from two pieces of glass (20 x 15 x 1.7 mm), and the 0.5-mm-diameter platinum disk was used as working electrode held at +1.15 V (vs silver wire quasi-reference), the stainless steel guide tubing as counter electrode, and the silver wire as quasi-reference electrode. The performance traits of the cell in both CE and FI modes were evaluated using tripropylamine, proline, and oxalate and compared favorably to those reported for CE and FI detection cells. The advantages of versatility, sensitivity, and accuracy make the device attractive for the routine analysis of amine-containing species or oxalate by CE and FI with Ru(bpy)3(2+) ECL detection.  相似文献   

11.
A new electrogenerated chemiluminescence detection method is investigated for use in detection in reversed-phase and reversed-phase ion-pair HPLC with Ru(bpy)(3)(2+) in the mobile phase. In this method, different concentrations of Ru(bpy)(3)(2+) are dissolved in the mobile phase and the HPLC column flushed with the mobile phase for 1 h until the column is saturated with Ru(bpy)(3)(2+). The separated analytes along with Ru(bpy)(3)(2+) pass through an optical-electrochemical flow cell which has a dual platinum electrode held at a potential of 1250 mV vs a Ag/AgCl reference electrode. On the surface of the electrode, Ru(bpy)(3)(2+) is oxidized to Ru(bpy)(3)(3+) which reacts with the analytes to emit light. The retention times, retention orders, detection limits, and linearity in working curves are compared to those obtained with the conventional postcolumn Ru(bpy)(3)(2+) addition method. The retention times for dansyl amino acids with Ru(bpy)(3)(2+) in the mobile phase are longer than those obtained with the postcolumn addition approach. This may be caused by π-to-π interactions between the aromatic groups of the dansyl derivatives and the bipyridyl groups of Ru(bpy)(3)(2+) in the Ru(bpy)(3)(2+)-saturated reversed-phase column. Similarly, oxalate is separated from urine and blood plasma samples by reversed-phase ion-pair HPLC. Plasma samples are obtained using ultrafiltration to remove proteins from whole blood. Retention times for oxalate with the two detection techniques are identical, and detection limits for these techniques are compared.  相似文献   

12.
Zu Y  Bard AJ 《Analytical chemistry》2001,73(16):3960-3964
We describe the effect of electrode surface hydrophobicity on the electrochemical behavior and electrogenerated chemiluminescence (ECL) of Ru(bpy)3(2+) (bpy = 2,2'-bipyridyl)/tripropylamine (TPrA) system. Gold and platinum electrodes were modified with different thiol monolayers. The hydrophobicity of the electrode surfaces changed with different terminal groups of the thiol molecules. The oxidation rate of TPrA was found to be much larger at the modified electrode with a more hydrophobic surface. The adsorption of neutral TPrA species on this kind of surface was assumed to contribute to the faster anodic kinetics. Due to the rapid generation of the highly reducing radical, TPrA., ECL intensity increased significantly at more hydrophobic electrodes. This electrode surface effect in the ECL analytical system allows one to improve the detection sensitivity at low concentrations of Ru(bpy)3(2+). The surfactant effect on the ECL process was also examined and discussed based on the change of electrode hydrophobicity by the adsorption of surfactant species.  相似文献   

13.
Yuan J  Li T  Yin XB  Guo L  Jiang X  Jin W  Yang X  Wang E 《Analytical chemistry》2006,78(9):2934-2938
A new method for prolidase (PLD, EC 3.4.13.9) activity assay was developed based on the determination of proline produced from enzymatic reaction through capillary electrophoresis (CE) with tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)3(2+)] electrochemiluminescence detection (ECL). A detection limit of 12.2 fmol (S/N = 3) for proline, corresponding to 1.22 x 10(-8) units of prolidase catalyzing for 1 min was achieved. PLD activity determined by CE-ECL method was in agreement with that obtained from the classical Chinard's one. CE-ECL showed its powerful resolving ability and selectivity as no sample pretreatment was needed and no interference existed. The clinical utility of this method was successfully demonstrated by its application to assay PLD activity in the serum of diabetic patients in order to evaluate collagen degradation in diabetes mellitus (DM). The results indicated that enhanced collagen degradation occurred in DM.  相似文献   

14.
Zu Y  Bard AJ 《Analytical chemistry》2000,72(14):3223-3232
We describe the electrogenerated chemiluminescence (ECL) processes of the Ru(bpy)3(2+) (bpy = 2,2'-bipyridyl)/ tripropylamine (TPrA) system at glassy carbon, platinum, and gold electrodes. The electrochemical behavior of TPrA on different electrode materials and its influence on the ECL process are demonstrated. At glassy carbon electrodes, the direct oxidation of TPrA began at approximately 0.6 V vs SCE and exhibited a broad irreversible anodic peak. Two ECL waves were observed, one in the potential region more negative than 1.0 V vs SCE and one at more positive potentials. The first ECL process apparently occurs without the electrogeneration of Ru(bpy)3(3+), in contrast to that of the second ECL wave. At Pt and Au electrodes, however, the formation of surface oxides significantly blocked the direct oxidation of TPrA. An ECL wave below 1.0 V did not appear at Pt and was very weak at gold. The ECL peaks at potentials of 1.1-1.2 V were also much weaker than those observed at the glassy carbon electrode. These results showed that the direct oxidation of TPrA played an important role in the ECL processes. Therefore, the enhancement of the TPrA oxidation current might lead to an increase in the ECL intensity. Small amounts of halide species were found to inhibit the growth of surface oxides on Pt and gold electrodes and led to an obvious increase of TPrA oxidation current. The anodic dissolution of gold in halide-containing solution was also important in activating the gold electrode surface. The electrochemical catalytic effect of bromide further promoted the oxidation of TPrA. A halide effect on ECL at Pt and Au electrodes was also evident. The most effective enhancement of ECL was observed at Au electrode in a bromide-containing solution. This effect was also found in an commercial flow-through instrument (IGEN) and provided a simple way to improve the detection sensitivity at low concentrations of Ru(bpy)3(2+).  相似文献   

15.
3-Isobutyl-9,10-dimethoxy-1,3,4,6,7,11b-hexahydro-2H-pyrido[2,1-a]isoquinolin-2-ylamine (IDHPIA) was found to be a selective and highly sensitive derivatization reagent for carboxylic acid by high-performance liquid chromatography (HPLC) with electrogenerated chemiluminescence detection using tris(2,2'-bipyridine)ruthenium(II). Free fatty acids and phenylbutylic acid were used as model compounds of carboxylic acids, and the derivatization conditions were optimized with myristic acid. Under the mild reaction conditions of room temperature for 45 min in acetonitrile containing 2-bromo-1-ethylpyridinium tetrafluoroborate and 9-methyl-3,4-dihydro-2H-pyridol1,2-a]pyrimidin-2-one, all the fatty acids tested were reacted with IDHPIA to produce highly sensitive derivatives. The chemiluminescence intensity was essentially the same for all fatty acids. The derivatives obtained from 10 free fatty acids were completely separated by reversed-phase chromatography under isocratic elution conditions. The on-column detection limit (signal-to-noise ratio of 3) with proposed HPLC separation and chemiluminescence detection was 0.5 and 0.6 fmol for myristic acid and phenylbutylic acid, respectively. IDHPIA was 100-fold more sensitive than previously developed reagents (Morita, H.; Konishi, M. AnaL Chem. 2002, 74, 1584-1589). The free fatty acids in human serum were successfully determined using the present method.  相似文献   

16.
We show here how a Ru(bpy)2(CE-bpy) complex can be used for the ECL detection of sodium ion in both aqueous and nonaqueous media. Recognition of Na+ by the crown ether moiety in CE-bpy results in a significant increase in the ECL emission intensity of the complex.  相似文献   

17.
Li F  Zu Y 《Analytical chemistry》2004,76(6):1768-1772
Fluorosurfactants are commercially available, and their applications in electrochemical systems have been the interest of many studies. Here, we describe a novel effect of a nonionic fluorosurfactant (Zonyl FSN) on the electrogenerated chemiluminescence (ECL) of the tris(2,2'-bipyridine)ruthenium(II)/tri-n-propylamine (TPrA) system at gold and platinum electrodes. Compared with its hydrocarbon analogue (Triton X-100), the adsorbed fluorosurfactant species not only rendered the electrode surfaces more hydrophobic but also significantly retarded the growth of the electrode oxide layers. As a result, more facile direct oxidation of TPrA was achieved, which led to the appearance of a low oxidation potential ECL signal (below 1.0 V vs SCE). At the gold electrode, the ECL peak appeared at 0.82 V, approximately 400 mV more negative than usual; while its intensity was approximately 50 times higher. The generation of the intense ECL signal at low oxidation potential may lead to the development of more efficient ECL analysis.  相似文献   

18.
19.
Xu G  Dong S 《Analytical chemistry》2000,72(21):5308-5312
A new detection scheme for the determination of adsorbable coreactants of Ru(bpy)3(2+) electrochemiluminescent reaction is presented. It is based on selective preconcentration of coreactant onto an electrode, followed by Ru(bpy)3(2+) electrochemiluminescent detection. The coreactant employed is chlorpromazine. It was sensitively detected after 5-min preconcentration onto a lauric acid-modified carbon paste electrode. The linear concentration range was found to occur from 1 x 10(-8) to 3 x 10(-6) mol L-1 with a detection limit of 3.1 x 10(-9) mol L-1. The total analysis time is less than 10 min. As a result of selective preconcentration and medium exchange, such remarkable selectivity is achieved that reproducible quantitation of chlorpromazine in urine is possible.  相似文献   

20.
Miao W  Bard AJ 《Analytical chemistry》2004,76(23):7109-7113
Biotinylated anti-C-reactive protein (CRP) species were attached to the surface of streptavidin-coated magnetic beads (MB) and avidin-coated polystyrene microspheres/beads (PSB) entrapping a large number of electrogenerated chemiluminescence (ECL) labels ( approximately 10(9) Ru(bpy)(3)[B(C(6)F(5))(4)](2)/bead) to form anti-CRP<-->MB and Ru(II) subsetPSB/avidin<-->anti-CRP conjugates, respectively. Sandwich-type Ru(II) subsetPSB/avidin<-->anti-CRP CRP anti-CRP<-->MB aggregates were formed when Ru(II) subsetPSB/avidin<-->anti-CRP was mixed with anti-CRP<-->MB conjugates in the presence of analyte CRP. The newly formed aggregates were magnetically separated from the reaction media and dissolved in MeCN containing tri-n-propylamine as an ECL coreactant. ECL was carried out with a potential scan from 0 to 2.8 V vs Ag/Ag(+), and the ECL intensity was found to be proportional to the analyte CRP concentration over the range of 0.010-10 mug/mL. The CRP concentration of an unknown human plasma specimen was measured by the standard addition method based on this technique. Elimination of the nonspecific adsorption of the CRP system with several different blocking agents was also studied, and 2.0% bovine serum albumin was found to be best.  相似文献   