首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Adsorption air-conditioning technology has attracted much attention recently due to its environmental friendly property. Some successes have been reported in the literature on the adsorption technology for air-conditioning applications. This paper presents an overview of the researches which had been carried out on adsorption refrigeration system with the commonly used adsorbent and adsorbate working pairs, solar adsorption refrigeration and adsorption technologies in automobile. Activated carbon has been widely used as the adsorbent in adsorption refrigeration system. However, one of the bottlenecks which prevent the improvement of the adsorption refrigeration technology using activated carbon is the use of the readily available commercial activated carbon without prior treatment, which has resulted in relatively lower performance as compared to the conventional absorption and vapour compression technologies. Various modification methods on activated carbon are thus discussed in this paper for future development and improvement of adsorption air-conditioning system.  相似文献   

2.
In this study, a lumped parameter simulation model has been developed for analysis of the thermal performance of a single-stage two-bed adsorption chiller. Since silica gel has low regeneration temperature and water has high latent heat of vaporisation, silica gel–water pair has been chosen as the working pair of the adsorption chiller. Low-grade waste heat or solar heat at around 70–80°C can be used to run this adsorption chiller. In this model, the effects of operating parameters on the performance of the chiller have been studied. The simulated results show that the cooling capacity of the chiller has an optimum value of 5.95?kW for a cycle time of 1600?s with the hot, cooling, and chilled water inlet temperatures at 85°C, 25°C, and 14°C, respectively. The present model can be utilised to investigate and optimise adsorption chillers.  相似文献   

3.
Solar refrigeration represents an important application of solar energy due to the excellent matching between the high sunshine and the refrigeration needs. Solar adsorption refrigeration devices are among the significant techniques used to meet the needs for cooling requirements. Several solar refrigeration systems have been proposed and are under development such as sorption systems including liquid/vapor, solid/vapor absorption, adsorption, vapor compression and others. The purpose of this paper is to identify the influence of a cylindrical adsorber on the performances of a solar adsorption refrigerating machine. The adsorber heated by solar energy contains an activated carbon–ammonia pair; it is composed by many cylindrical tubes welded using external fins. A model based on the conservation equations of energy and mass in the adsorber has been developed and well described. Using real solar irradiance data as well as many initial conditions, the model computes for each point and in the considered time interval during the day, the temperature, the adsorbed mass, the pressure inside the adsorber and the solar performance coefficient (COP). The results show that the optimal diameter of the adsorber with fins is greater than the one without fins. Moreover the mass cycled in the case of an adsorber equipped with external fins is more significant than the one without fins, and the maximal temperature reached in the adsorber with fins attains 97 °C while in the adsorber without fins reaches 77 °C. Thus, the performances of the solar adsorption refrigerating machine with an adsorber equipped with fins are higher than the machine without fins.  相似文献   

4.
A laboratory model of a thermally driven adsorption refrigeration system with activated carbon as the adsorbent and 1,1,1,2-tetrafluoroethane (HFC 134a) as the refrigerant was developed. The single stage compression system has an ensemble of four adsorbers packed with Maxsorb II specimen of activated carbon that provide a near continuous flow which caters to a cooling load of up to 5 W in the 5–18 °C region. The objective was to utilise the low grade thermal energy to drive a refrigeration system that can be used to cool some critical electronic components. The laboratory model was tested for its performance at various cooling loads with the heat source temperature from 73 to 93 °C. The pressure transients during heating and cooling phases were traced. The cyclic steady state and transient performance data are presented.  相似文献   

5.
6.
7.
The objective of this paper is to experimentally determine the efficiency and viability of the performance of an advanced trigeneration system that consists of a micro gas turbine in which the exhaust gases heat hot thermal oil to produce cooling with an air cooled absorption chiller and hot water for heating and DHW. The micro gas turbine with a net power of 28 kW produces around 60 kW of heat to drive an ammonia/water air-cooled absorption chiller with a rated capacity of 17 kW. The trigeneration system was tested in different operating conditions by varying the output power of the micro gas turbine, the ambient temperature for the absorption unit, the chilled water outlet temperature and the thermal oil inlet temperature. The modelling performance of the trigeneration system and the electrical modelling of the micro gas turbine are presented and compared with experimental results. Finally, the primary energy saving and the economic analysis show the advantages and drawbacks of this trigeneration configuration.  相似文献   

8.
Growing concern about global warming has directed much attention towards natural gas-driven co-generation systems (CGS). For wider use of CGS in Japan, innovative technologies to utilize the waste heat of CGS more efficiently for the air-conditioning of office buildings have been long required. Tokyo Gas has developed a high-performance gas absorption chiller heater with auxiliary waste heat recovery. This paper presents the results of the development, including a numerical cycle simulation and experiments for heating and cooling.  相似文献   

9.
This paper presents a techno-economic analysis of corn stover fired process heating (PH) and the combined heat and power (CHP) generation systems for a typical corn ethanol plant (ethanol production capacity of 170 dam3). Discounted cash flow method was used to estimate both the capital and operating costs of each system and compared with the existing natural gas fired heating system. Environmental impact assessment of using corn stover, coal and natural gas in the heat and/or power generation systems was also evaluated. Coal fired process heating (PH) system had the lowest annual operating cost due to the low fuel cost, but had the highest environmental and human toxicity impacts. The proposed combined heat and power (CHP) generation system required about 137 Gg of corn stover to generate 9.5 MW of electricity and 52.3 MW of process heat with an overall CHP efficiency of 83.3%. Stover fired CHP system would generate an annual savings of 3.6 M$ with an payback period of 6 y. Economics of the coal fired CHP system was very attractive compared to the stover fired CHP system due to lower fuel cost. But the greenhouse gas emissions per Mg of fuel for the coal fired CHP system was 32 times higher than that of stover fired CHP system. Corn stover fired heat and power generation system for a corn ethanol plant can improve the net energy balance and add environmental benefits to the corn to ethanol biorefinery.  相似文献   

10.
Radiative–conductive heat transfer in a medium bounded by two reflecting and radiating plane surfaces is considered. This process is described by a nonlinear system of two differential equations: an equation of the radiative heat transfer and an equation of the conductive heat exchange. The problem is characterized by anisotropic scattering of the medium and by specularly and diffusely reflecting boundaries. For the computation of solutions of this problem, two approaches based on iterative techniques are considered. First, a recursive algorithm based on some modification of the Monte Carlo method is proposed. Second, the diffusion approximation of the radiative transfer equation is utilized. Numerical comparisons of the approaches proposed are given in the case of isotropic scattering.  相似文献   

11.
This paper describes the development and use of a hydrogen infrastructure optimization model using the TIMES modeling framework, H2TIMES, to analyze hydrogen development in California to 2050. H2TIMES is a quasi-spatial model that develops the infrastructure to supply hydrogen fuel in order to meet demand in eight separate California regions in a least cost manner subject to various resource, technology and policy constraints. A Base case, with a suite of hydrogen policies now in effect or proposed in California (renewable hydrogen mandate, fuel carbon intensity constraint and prohibition on using coal without carbon capture and sequestration) leads to hydrogen fuel with significant reductions in carbon intensity (85% below gasoline on an efficiency-adjusted basis, 75% below on a raw energy basis) and competitive hydrogen costs (∼$4.00/kg in 2025–2050). A number of sensitivity scenarios investigate the cost and emissions implications of altering policy constraints, technology and resource availability, and modeling decisions. The availability of biomass for hydrogen production and carbon capture and sequestration are two critical factors for achieving low-cost and low-emission hydrogen.  相似文献   

12.
In this paper, a viscous fluid flowing past a rotating isothermal cylinder with heat transfer is studied and simulated numerically by the lattice Boltzmann method (LBM). A numerical strategy for dealing with curved and moving boundaries of second-order accuracy for both velocity and temperature fields is proposed and presented. The numerical strategy and method are validated by comparing the present numerical results of flow without heat transfer with those of available previous theoretical, experimental and numerical studies, showing good agreements. On this basis, the convective heat transfer performance in such rotational boundary environments is further studied and validated; the numerical results are reported in the first time. The effects of the peripheral-to-translating-speed ratio, Reynolds number and Prandtl number on flow and heat transfer are discussed in details.  相似文献   

13.
A composite adsorbent composed of BaCl2 impregnated into expanded vermiculite has been synthesized and tested in a laboratory scale adsorption chiller. Previous work has established the promising theoretical performance of this adsorbent with ammonia as a refrigerant, in terms of equilibrium uptake, suitable equilibrium temperatures for use in air conditioning applications and good reaction dynamics. Analysis of the adsorption phase revealed a simple exponential approach to equilibrium uptake which was not previously observed in larger scale experiments.It was demonstrated that this material can provide effective operation of the chiller using a low potential heat source (80–90 °C) giving COP as high as 0.54 ± 0.01 and SCP ranging from 300 to 680 W/kg. The specific cooling power depends strongly on the driving temperature difference and the cycle duration.  相似文献   

14.
Parameter estimation problems and heat source/flux reconstruction problems are some of the most frequently encountered inverse heat transfer problems. These problems find their application in many areas of science and engineering. The primary focus of this paper is on the heat transfer parameter estimation for a two-dimensional unsteady heat conduction problem with (a) convection boundary condition and (b) convection and radiation boundary condition. The paper demonstrates the effect of a priori model on the performance of the algorithm at different noise levels in the measured data. The inverse problem is solved using three different a priori models namely normal, log normal and uniform. The posterior PDF is sampled using the Metropolis–Hastings sampling algorithm. Both single-parameter estimation and multi-parameter estimation problems are addressed and the effects of corresponding a priori models are studied. It was found that the mean and maximum a posteriori estimates for thermal conductivity and the convection heat transfer coefficient were insensitive to the a priori model at all the considered noise levels for the single-parameter estimation problem. At high noise levels in the two-parameter estimation problem, the estimates for thermal conductivity and convection coefficient were sensitive to the a priori model. It was also found that the standard deviation of the samples was correlated to the error in estimation in the single-parameter estimation case. In three parameter estimation case, alternate solutions to the same problem were retrieved due to a strong correlation between the convection coefficient and the emissivity. However, a more informative a priori model could address this issue.  相似文献   

15.
This paper presents and analyzes a novel fossil-fuel–free trans-critical energy storage system that uses CO2 as the working fluid in a closed loop shuttled between two saline aquifers or caverns at different depths: one a low-pressure reservoir and the other a high-pressure reservoir. Thermal energy storage and a heat pump are adopted to eliminate the need for external natural gas for heating the CO2 entering the energy recovery turbines. We carefully analyze the energy storage and recovery processes to reveal the actual efficiency of the system. We also highlight thermodynamic and sensitivity analyses of the performance of this fossil-fuel–free trans-critical energy storage system based on a steady-state mathematical method. It is found that the fossil-fuel–free trans-critical CO2 energy storage system has good comprehensive thermodynamic performance. The exergy efficiency, round-trip efficiency, and energy storage efficiency are 67.89%, 66%, and 58.41%, and the energy generated of per unit storage volume is 2.12 kW·h/m3, and the main contribution to exergy destruction is the turbine reheater, from which we can quantify how performance can be improved. Moreover, with a higher energy storage and recovery pressure and lower pressure in the low-pressure reservoir, this novel system shows promising performance.  相似文献   

16.
In this paper, the laminar forced convection heat transfer of the water-based nanofluid inside a minichannel heat sink is studied numerically. An Eulerian two-fluid model is considered to simulate the nanofluid flow inside the triangular heat sink and the governing continuity, momentum, and energy equations for both phases are solved using the finite volume method. Comparisons of the Nusselt number predicted by the Eulerian–Eulerian model with the experimental data available in the literature demonstrate that the simulation results are in excellent agreement with the experimental data and the maximum deviation from experimental data is 5%. The results show that the heat sink with nanofluid has a better heat transfer rate in comparison with the water-cooled heat sink. Also, the heat transfer enhancement increases with an increase in Reynolds number and nanoparticle volume concentration. In addition, the friction factor increases slightly for nanofluid-cooled minichannel heat sink.  相似文献   

17.
18.
It is imperative to mitigate the convective heat loss from the receiver to improve the overall efficiency of the parabolic dish concentrator. In this study, the reductions of convective heat loss from the cylindrical-hemispherical receiver are numerically analyzed and the model was validated by the experimental data from literature. In the first case, the impact of the glass cover on convective heat loss is examined under conditions of both natural and forced convections at various receiver orientations (γ = 0°, 30°, 60°, and 90°). Numerical results clearly demonstrate that the use of a glass cover significantly reduces the intrusion of surrounding air into the receiver cavity which leads to an enhancement of the stagnation zone inside the cavity and, as a consequence, a noticeable reduction in convective heat loss is observed. To perform analysis of the receiver with glass cover under forced convective condition, the wind velocities over the receiver are considered in the range of 1–6 m/s. The maximum reduction of convective heat loss using the glass cover is achieved to be 58.44% with wind velocity of 5 m/s at γ = 60°. In the second case, the influence of air curtain at the receiver aperture under natural convective heat loss conditions is analyzed. The analysis incorporates three variables: receiver orientation (γ = 0°–60°), nozzle width ( L noz ${L}_{\mathrm{noz}}$ = 0.002–0.004 m), and nozzle outlet velocity ( V noz ${V}_{\mathrm{noz}}$ = 0.5–3.5 m/s). The results show that the air curtain minimizes the outflow of receiver inside air and results in an improvement in the stagnation zone inside the cavity. The maximum effectiveness of the air curtain is found to be 43.2% at nozzle width of L noz ${L}_{\mathrm{noz}}$ = 0.004 m and nozzle velocity of V noz ${V}_{\mathrm{noz}}$ = 1.5 m/s at receiver orientation of 60°. It is also noteworthy that the optimal nozzle velocity decreases with the increase of nozzle widths.  相似文献   

19.
20.
In this paper, a new variant of the k-ε turbulence model (Saqr et al., CFD Letters, 1(2) pp. 87–94) is used to compute the shear driven vortex flow in an open cylindrical cavity. The results are compared with published LDA measurements for such flow configuration. The modified turbulence model demonstrated good agreement with experimental results, which further supports its validity in computing vortex dominated flows.  相似文献   