首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到5条相似文献,搜索用时 0 毫秒
1.
Zhang Y  He F  Wan Y  Meng M  Xu J  Yi J  Wang Y  Feng C  Wang S  Xi R 《Talanta》2011,83(3):732-737
Trenbolone (TRE) is a steroid used by veterinarians on livestock to increase appetite and body weight. The use of TRE has been restricted because of its harmful side effect for consumers. To effectively control TRE residue in food and food product, a rapid and convenient immunoassay was developed by preparing an anti-TRE monoclonal antibody. The immunogen and coating antigen were prepared by coupling TRE hapten with carrier proteins via 1-ethyl-3-(dimethylaminopropyl)carbodiimide hydrochloride (EDC) method. The optimized method gave an average IC50 value of 0.323 ng mL−1 towards TRE and an average detection limit (LOD) of 0.06 ng mL−1, which is much lower than the maximum residue levels (2.0 ng g−1) accepted by the Joint FAO/WHO Expert Committee on Food Additives (JECFA). The specificity of the antibody was evaluated by measuring cross-reactivity of six structurally related compounds, including 19-nortestosterone (9.7%), testosterone (0.13%), methyltestosterone (<0.01%), methandrostenolone (<0.01%), (+)-dehydroisoandrosterone (<0.001%) and β-estradiol (<0.001%). The recovery rates of the test in detection of TRE-fortified animal tissue, urine and animal feed samples were in the range of 81.3-89.4%, while the intra- and inter-assay coefficients of variation were less than 12.0%.  相似文献   

2.
Monoclonal antibodies against the hop-derived prenylated chalcone xanthohumol (X) and the prenylated flavonoids isoxanthohumol (IX) and 8-prenylnaringenin (8-PN) were developed. Carboxylic acid haptens of X, IX and 8-PN were synthesized by linking a spacer to their C4′-OH group followed by subsequent coupling to bovine serum albumin (BSA) to form conjugates that were employed as immunogens in BALB/c mice to raise antibodies. The monoclonal antibodies that were secreted from the established hybridoma cell lines proved, in cross-reactivity studies, to possess highly specific binding capacities in an optimized competitive indirect ELISA. The immunoassays make use of immunogen-coated microtiterplates and a peroxidase-labeled anti-mouse IgG1 secondary antibody with ABTS as a chromogenic substrate. For X the IC50 value derived from the standard curve was 62.91 ng mL−1, and for both IX and 8-PN 37.15 ng mL−1. The assay was validated for the quantitative analysis of X, IX and 8-PN in urine and serum. A simple sample pretreatment procedure using a diethyl ether extraction was optimized and the recoveries and matrix effects were assessed. The validity of the established assay was tested and mean inter- and intra-assay variations in urine were 2.32% and 1.91%, respectively for X, 6.24% and 2.39%, respectively for IX and 7.18% and 0.74%, respectively for 8-PN. In serum, the mean inter- and intra-assay variations were 8.90% and 1.37%, respectively for X, 6.13% and 1.57%, respectively for IX and 6.13% and 2.43%, respectively for 8-PN. Furthermore, the method demonstrated excellent accuracy and significant correlation with measurements by an established and validated HPLC-MS method.  相似文献   

3.
Zhang Q  Wang L  Ahn KC  Sun Q  Hu B  Wang J  Liu F 《Analytica chimica acta》2007,596(2):303-311
Five haptens with different spacer-arm attachment sites on the structure of the organophosphorus insecticide fenthion were designed and synthesized. All of the haptens were conjugated with ovalbumin (OVA) for the coating antigen, and three haptens containing all or most of the structure of fenthion were conjugated with bovine serum albumin (BSA) for the immunogen. Six polyclonal antisera were raised against the three BSA conjugates, and 30 antibody/coating conjugate combinations were selected for studies of assay sensitivity and specificity for fenthion. The study revealed the best combination with high sensitivity (I50 of 0.08 ng mL−1) and high assay specificity, which indicated that when structural difference between the analyte and an immunizing hapten is less than that between a coating hapten and the immunizing hapten, a high sensitive enzyme-linked immunosorbent assay (ELISA) in the heterologous system may stand a good chance to be developed. The immunity results showed that heterology in the hapten spacer-arm attachment site of the immunogen could achieve a remarkable improvement in the quantity, sensitivity, and/or specificity of antibody, and that the moiety of an analyte, which is the same as the moiety near/on the immunizing spacer-arm hapten attachment site, contributes greatly to the interaction of antibody and hapten.  相似文献   

4.
The incorporation of melamine into food products is banned but its misuse has been widely reported in both animal feeds and food. The development of a rapid screening immunoassay for monitoring of the substance is an urgent requirement. Two haptens of melamine were synthesized by introducing spacer arms of different lengths and structures on the triazine ring of the analyte molecular structure. 6-Aminocaproic acid and 3-mercaptopropionic acid were reacted with 2-chloro-4,6-diamino-1,3,5-triazine (CAAT) to produce hapten 1 [3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylamino) hexanoic acid] and hapten 2 [3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylthio) propanoic acid], respectively. The molecular structures of the two haptens were identified by 1H nuclear magnetic resonance spectrometry, mass spectrometry and infrared spectrometry. An immunogen was prepared by coupling hapten 1 to bovine serum albumin (BSA). Two plate coating antigens were prepared by coupling both haptens to egg ovalbumin (OVA). A competitive indirect enzyme-linked immunosorbent assay (ciELISA) was developed to evaluate homogeneous and heterogeneous assay formats. The results showed that polyclonal antibodies with high titers were obtained, and the heterogeneous immunoassay format demonstrated a better performance with an IC50 of 70.6 ng mL−1, a LOD of 2.6 ng mL−1 and a LOQ of 7.6 ng mL−1. Except for cyromazine, no obvious cross-reactivity to common compounds was found. The data showed that the hapten synthesis was successful and the resultant antisera could be used in an immunoassay for the rapid and sensitive detection of this banned chemical.  相似文献   

5.
A polyclonal antibody (Ab) for the progestin levonorgestrel (LNG) was generated, and immunochemical assays for its detection, clean-up and concentration were developed. A highly specific microplate diagnostic assay for the detection of LNG was developed that used the enzyme linked immunosorbent assay (ELISA) method. The LNG ELISA developed was sensitive and reproducible; it exhibited I50 and I20 values of 3.3 ± 1.8 ng mL−1 and 0.6 ± 0.4 ng mL−1, respectively, and the Abs did not cross react with any of the tested steroid hormones. The above Abs were used to develop a sol-gel-based immunoaffinity purification (IAP) method for concentration and clean-up of LNG that is compatible with subsequent immunochemical or instrumental chemical analytical procedures, such as liquid chromatography followed by mass spectrometry (LC-MS/MS). Development of the columns included successful entrapment of Abs within a tetramethoxysilane (TMOS)-based SiO2 polymer network. The Abs could bind the free analyte from solution, and the bound analyte could be easily eluted from the sol-gel matrix at high recoveries. The Ab selectivity towards the antigen was high, in both ELISA and the sol-gel columns, but the entrapped Abs cross-reacted with two other steroid hormones - ethynylestradiol (EE2) and nortestosterone (NT) - which share similar epitopes with LNG, despite the lack of cross reactivity in the ELISA. The validity of the method was investigated by LC-MS/MS and a good analytical correlation was obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号