首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
Gas chromatography–mass spectrometry (GC-MS) method and a liquid chromatography–fluorescence (LC-FL) detection method using experimental design and optimisation approach were improved for the quantitative determination of nitrite and nitrate in biological, food and environmental samples. The obtained recoveries of nitrite and nitrate ions from samples based on both GC-MS and LC-FL results ranged from 98.5% to 98.9% for nitrite and 97.9% to 98.4% for nitrate. The precision of these methods, as indicated by the relative standard deviations (RSDs), was within the range from 2.4% to 3.6% for nitrite and 2.5% to 3.8% for nitrate, respectively. The limits of detection of nitrite and nitrate ions from samples based on GC-MS and LC-FL results ranged from 0.01 to 0.14 ng L?1 for nitrite and 0.02 to 0.71 ng L?1 for nitrate, respectively. The optimised isolation procedure by central composite design was successfully applied to real samples. The results revealed that the proposed procedure combined with GC-MS and LC-FL techniques is more sensitive, reliable and selective compared to the other methods available for the precise determination of trace levels of nitrite and nitrate in biological, food and environmental samples.  相似文献   

2.
Pan X  Tian K  Jones LE  Cobb GP 《Talanta》2006,70(2):455-459
A simple, sensitive LC-ESI-MS method was optimized for quantitative analysis of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) in environmental samples. Under negative ionization mode, HMX can form adduct ions with various organic acids and salts, including acetic acid, formic acid, propionic acid, ammonium nitrate, ammonium chloride, sodium nitrite, and sodium nitrate. Acetic acid was chosen as additive and the ion, [M + CH3COO] with m/z = 355 was used for selective ion monitoring (SIM) in this study. Good sensitivity was achieved with low acetic acid concentration in the mobile phase and relatively low capillary temperature. The method detection limit was 0.78 pg for HMX in standard solution. Linearity (R2 > 0.9998) was obtained at low concentrations (0.5-50 μg/L). This method has been used to determine HMX concentrations in water samples and lizard egg samples from an animal exposure study.  相似文献   

3.
Chen PS  Huang SD 《Talanta》2006,69(3):669-675
A technique for the analysis of organophosphorus pesticides (ethoprop, diazinon, disulfoton, fenthion) in aqueous sample using liquid-phase microextraction (LPME), coupled with gas chromatography-mass spectrometry (GC-MS) was developed. A small section of a hollow fiber inserted into the needle of GC syringe and filled with the 3.5 μl of organic solvent was used to extract pesticides from a 20 ml aqueous sample. The limits of detection (LOD) with the selected ion monitoring (SIM) mode varied from 0.2 to 0.006 μg/l. The calibration curves were linear over three orders of magnitude with R2 ≥ 0.996. The relative standard deviations of the analysis (inter- and intra-day) were 5-8%, and the relative recoveries from the lake water sample were greater than 83%. The results were compared with results obtained using solid-phase microextraction (SPME/GC/MS).  相似文献   

4.
In this work a new electrochemical sensor based on an Ag-doped zeolite-expanded graphite-epoxy composite electrode (AgZEGE) was evaluated as a novel alternative for the simultaneous quantitative determination of nitrate and nitrite in aqueous solutions. Cyclic voltammetry was used to characterize the electrochemical behavior of the electrode in the presence of individual or mixtures of nitrate and nitrite anions in 0.1 M Na2SO4 supporting electrolyte. Linear dependences of current versus nitrate and nitrite concentrations were obtained for the concentration ranges of 1-10 mM for nitrate and 0.1-1 mM for nitrite using cyclic voltammetry (CV), chronoamperometry (CA), and multiple-pulsed amperometry (MPA) procedures. The comparative assessment of the electrochemical behavior of the individual anions and mixtures of anions on this modified electrode allowed determining the working conditions for the simultaneous detection of the nitrite and nitrate anions. Applying MPA allowed enhancement of the sensitivity for direct and indirect nitrate detection and also for nitrite detection. The proposed sensor was applied in tap water samples spiked with known nitrate and nitrite concentrations and the results were in agreement with those obtained by a comparative spectrophotometric method. This work demonstrates that using multiple-pulse amperometry with the Ag-doped zeolite-expanded graphite-epoxy composite electrode provides a real opportunity for the simultaneous detection of nitrite and nitrate in aqueous solutions.  相似文献   

5.
In this work, it was developed a method for the determination of nitrite and nitrate in groundwater by high-resolution continuum source electrothermal molecular absorption spectrometry of NO produced by thermal decomposition of nitrate in a graphite furnace. The NO line at 215.360 nm was used for all analytical measurements and the signal obtained by integrated absorbance of three pixels. A volume of 20 μL of standard solution or groundwater sample was injected into graphite furnace and 5 μL of a 1% (m/v) Ca solution was co-injected as chemical modifier. The pyrolisis and vaporization temperatures established were of 150 and 1300 °C, respectively. Under these conditions, it was observed a difference of thermal stability among the two nitrogen species in the presence of hydrochloric acid co-injected. While that the nitrite signal was totally suppressed, nitrate signal remained nearly stable. This way, nitrogen can be quantified only as nitrate. The addition of hydrogen peroxide provided the oxidation of nitrite to nitrate, which allowed the total quantification of the species and nitrite obtained by difference. A volume of 5 μL of 0.3% (v/v) hydrochloric acid was co-injected for the elimination of nitrite, whereas that hydrogen peroxide in the concentration of 0.75% (v/v) was added to samples or standards for the oxidation of nitrite to nitrate. Analytical curve was established using standard solution of nitrate. The method described has limits of detection and quantification of 0.10 and 0.33 μg mL−1 of nitrogen, respectively. The precision, estimated as relative standard deviation (RSD), was of 7.5 and 3.8% (n = 10) for groundwater samples containing nitrate–N concentrations of 1.9 and 15.2 μg mL−1, respectively. The proposed method was applied to the analysis of 10 groundwater samples and the results were compared with those obtained by ion chromatography method. In all samples analyzed, the concentration of nitrite–N was always below of the limit of quantification of both the methods. The concentrations of nitrate–N varied from 0.58 to 15.5 μg mL−1. No significant difference it was observed between the results obtained by both methods for nitrate–N, at the 95% confidence level.  相似文献   

6.
A flow injection (FI) method with flame atomic absorption spectrometry (FAAS) detection was developed for the determination and speciation of nitrite and nitrate in foodstuffs and wastewaters. The method is based on the oxidation of nitrite to nitrate using a manganese(IV) dioxide oxidant microcolumn where the flow of the sample through the microcolumn reduces the MnO2 solid phase reagent to Mn(II), which is measured by FAAS. The absorbance of Mn(II) are proportional to the concentration of nitrite in the samples. The injected sample volume was 400 μL with a sampling rate of analyses was 90 h−1 with a relative standard deviation better than 1.0% in a repeatability study. Nitrate is reduced to nitrite in proposed FI-FAAS system using a copperized cadmium microcolumn and analyzed as nitrite. The calibration curves were linear up to 20 mg L−1 and 30 mg L−1 with a detection limit of 0.07 mg L−1 and 0.14 mg L−1 for nitrite and nitrate, respectively. The results exhibit no interference from the presence of large amounts of ions. The method was successfully applied to the speciation of nitrite and nitrate in spiked natural water, wastewater and foodstuff samples. The precision and accuracy of the proposed method were comparable to those of the reference spectrophotometric method.  相似文献   

7.
Spectrophotometric flow injection methods were developed for the individual determination of nitrite or nitrate, and for the simultaneous determination of nitrite and nitrate, in soil samples. Nitrite was determined directly using a modified version of the Griess-Ilosvay diazo-coupling reaction, measuring at 543 nm the absorbance of the azo-dye complex formed. Simultaneous nitrite and nitrate determinations were based on on-line nitrate reduction in a micro column containing copperised cadmium. A single chromogenic reagent containing all the necessary reactants was used in both methods. For determinations, the chemical and instrumental variables were optimised by univariate analysis and simplex chemometric method. The optimised conditions gave a linear calibration range between 0.05 and 1.6 µg m L− 1 for N-NO2 and between 0.05 and 7.0 µg m L− 1 for N-NO3. The detection limits for nitrite and nitrate were 22 µg L− 1 and 44 µg L− 1 respectively. The proposed methods allowed up to 35-40 samples per hour to be analysed with good precision. The simultaneous method was successfully used for the determination of nitrite and nitrate in soil samples (the results obtained were validated against those obtained by reference methods). The proposed methods are simpler and faster than conventional methods and could be routinely used in environmental monitoring laboratories.  相似文献   

8.
A simple, sensitive and selective method for the simultaneous determination of nitrite and nitrate in water samples has been developed. The method is based on ion-exchange separation, online photochemical reaction, and luminol chemiluminescence detection. The separation of nitrite and nitrate was achieved using an anion-exchange column with a 20 mM borate buffer (pH 10.0). After the separation, these ions were converted to peroxynitrite by online UV irradiation using a low-pressure mercury lamp and then mixed with a luminol solution prepared with carbonate buffer (pH 10.0). The calibration graphs of the nitrite and nitrate were linear in the range from 2.0 × 10−9 to 2.5 × 10−6 M and 2.0 × 10−8 to 2.5 × 10−5 M, respectively. Since the sensitivity of nitrite was about 10 times higher than that of nitrate, the simultaneous determination of nitrite and nitrate in the water samples could be efficiently achieved. This method was successfully applied to various water samples – river water, pond water, rain water, commercial mineral water, and tap water – with only filtration and dilution steps.  相似文献   

9.
A rapid, simple miniaturised photometrical method was developed for the determination of nitrate and/or nitrite in freshwater samples. All procedures, including sample buffering, reduction by copperised cadmium granules, colour development and absorbance determination, were completed in a 96-well microplate. The factors governing the nitrate reduction and its recovery were investigated in detail, and the optimised analysing conditions were established. Nitrate was quantitatively reduced by copperised cadmium granules with a high reduction efficiency (96.59 ± 0.96%). The proposed method gave a linear calibration ranging from 0.01 to 1.50 mg L−1 for NO2-N and 0.02 to 1.50 mg L−1 for NO3-N. The detection limits for nitrite and nitrate were 2 and 4 μg L−1, respectively. The proposed method allowed at least 48 samples to be simultaneously analysed in duplicate, with good precision, within 90 min for nitrate and 30 min for nitrite, and was successfully applied to actual freshwater sample analysis with a recovery of 98.02 ± 1.04% for nitrite and 99.72 ± 1.39% for nitrate. This method produced accurate results comparable to standard methods, provided a much higher sample throughput than conventional methods and could be routinely used in actual freshwater sample monitoring.  相似文献   

10.
A new approach for in situ electrodeposition of a renewable copper layer onto a copper electrode is reported. The active surface was obtained by anodic dissolution of a copper electrode at an appropriate potential and further redeposition of copper ions still remaining at the diffusion layer. Under optimal experimental conditions the peak current response increases linearly with nitrate concentration over a range of 0.1-2.5 mmol L−1. The repeatability of measurements for nitrate was evaluated as 1.8% (N = 15) and the limit of detection of the method was found to be 11 μmol L−1 (S/N = 3). Nitrate contents in two different samples (mineral water and sausages) compared well with those obtained from using the standard Griess protocol at a 95% of confidence level measured by the t-student test. The interference from chloride on the nitrate analysis and the possibility of simultaneous determination of nitrite were also examined.  相似文献   

11.
Zhang M  Zhang Z  Yuan D  Feng S  Liu B 《Talanta》2011,84(2):443-450
An automatic gas-phase molecular absorption spectrometric (GPMAS) system was developed and applied to determine nitrite and total nitrate in water samples. The GPMAS system was coupled with a UV-light emitting diode photodiode (UV-LED-PD) based photometric detector, including a 255 nm UV-LED as the light source, a polyvinyl chloride (PVC) tube of 14 cm as the gas flow cell, and an integrated photodiode amplifier to measure the transmitted light intensity. The UV-LED-PD detector was compact, robust, simple and of low heat production, comparing with detectors used in other GPMAS works. For nitrite measurement, citric acid was used to acidify the sample, and ethanol to catalyze the quantitative formation of NO2. The produced NO2 was purged with air flow into the UV-LED-PD detector, and the gaseous absorbance value was measured. The total nitrate could be determined after being reduced to nitrite with a cadmium column. Limits of detection for nitrite and nitrate were 7 μmol/L and 12 μmol/L, respectively; and linear ranges of 0.021-5 mmol/L for nitrite and 0.036-4 mmol/L for nitrate were obtained. Related standard deviations were 1.81% and 1.08% for nitrite and nitrate, respectively, both at 2 mmol/L. The proposed method has been applied to determine nitrite and total nitrate in some environmental water samples.  相似文献   

12.
Mercury-pyrrolidinedithiocarbamate complexes are first time used for speciation of aquatic mercury with high-performance liquid chromatographic/ion trap-mass spectrometric method utilizing atmospheric pressure chemical ionization (APCI). The separation of the four mercury species was achieved in less than 5 min with a linear gradient profile of aqueous methanol from 70 up to 100% (v/v) in 4th min, isocratic elution at 100% up to 5th min and followed by a negative gradient to 70% in 6th min. The best separation was achieved on a reverse phase Zorbax Eclipse XDB C18 column (50 mm × 2.1 mm i.d., 1.8 μm particle size). The on-column limits of detection (injection volume 1 μL) were 370 pg for methylmercury (MeHg+), 280 pg for ethylmercury (EtHg+), 250 pg for phenylmercury (PhHg+) and 90 pg for inorganic mercury (Hg2+) when the data were collected in selective ion monitoring (SIM) mode. A method of isolation and preconcentration of the mercury species using a “home-made” C18 solid phase extraction (SPE) microcolumns was developed to enhance sensitivity of the method. The preconcentration factor as much as 2500 was achieved with on-column complex formation of mercury-pyrrolidinedithiocarbamate. Methanol (100%) was chosen for elution of preconcentrated mercury species. The method was applied for the determination of mercury species in river water samples.  相似文献   

13.
A fast and highly sensitive high performance liquid chromatographic/ion-trap mass spectrometric method (LC/MS) has been developed for simultaneous determination of ethynylestradiol (EE2), gestodene (GES), levonorgestrel (LNG), cyproterone acetate (CPA) and desogestrel (DES). Among three types of sorbents tested (C8, C18 and phenyl) from two suppliers, the best separation was achieved on reverse phase Zorbax SB-Phenyl column using aqueous methanol as a mobile phase. A linear gradient profile from 70 up to 100% (v/v) in 7th min, kept constant at 100% up to 10th min and followed by a negative gradient to 70% of methanol up to 12th min was used for elution. Applicability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) and influence of the mobile phase composition, its flow rate, capillary/vaporizer temperature of API source and in-source fragmentor voltage ionization are discussed. The on-column limits of quantification (10 S/N) were 300 pg of EE2, 14 pg of GES and LNG, 4 pg of CPA and 960 pg of DES per injection (1 μL) using APCI with data collection in selected ion monitoring (SIM) mode. The analytical performance of the method was evaluated using the determination of EE2, GES, LNG, CPA and DES in contraceptives and river water samples.  相似文献   

14.
A method based on immersed solid-phase microextraction (SPME) and gas chromatography mass spectrometry detection (GC-MS) for the determination of organophosphorous pesticides (OPPs) in aqueous samples was developed. A sol-gel based coating fiber was prepared using 3-(trimethoxysilylpropyl) amine as precursor. The synthesized fiber was prepared in a way to impart polar moiety into the coating network and would be more suitable for extracting polar and semi-polar organic pollutants. Important parameters influencing the extraction process were optimized and an extraction time of 40 min at 30 °C gave maximum peak area, when NaCl (20% w/v) was added to the aqueous sample. The linearity for disulfoton, phorate and sulfotep was in the concentration range of 0.01 to 5 ng mL− 1 and for parathion and O,O,O-triethylthiphosphate was in the range of 0.01 to 50 ng mL− 1. Limits of detection ranged from 1 ng L− 1, for parathion, to 0.05 ng L− 1, for disulfoton using time-scheduled selected ion monitoring (SIM) mode, and the RSD% values were all below 10.5% at the 1 ng mL− 1 level. The developed method was successfully applied to real water samples while the relative recovery percentages obtained for the spiked water samples were from 80 to 115%.  相似文献   

15.
A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg−1, respectively. This validated method was successfully applied to the determination of melamine in real samples from market.  相似文献   

16.
A simple and sensitive automated method for determination of aflatoxins (B1, B2, G1, and G2) in nuts, cereals, dried fruits, and spices was developed consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–mass spectrometry (LC–MS). Aflatoxins were separated within 8 min by high-performance liquid chromatography using a Zorbax Eclipse XDB-C8 column with methanol/acetonitrile (60/40, v/v): 5 mM ammonium formate (45:55) as the mobile phase. Electrospray ionization conditions in the positive ion mode were optimized for MS detection of aflatoxins. The pseudo-molecular ions [M+H]+ were used to detect aflatoxins in selected ion monitoring (SIM) mode. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample using a Supel-Q PLOT capillary column as an extraction device. The extracted aflatoxins were readily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC–MS with SIM method, good linearity of the calibration curve (r > 0.9994) was obtained in the concentration range of 0.05–2.0 ng/mL using aflatoxin M1 as an internal standard, and the detection limits (S/N = 3) of aflatoxins were 2.1–2.8 pg/mL. The in-tube SPME method showed >23-fold higher sensitivity than the direct injection method (10 μL injection volume). The within-day and between-day precision (relative standard deviations) at the concentration of 1 ng/mL aflatoxin mixture were below 3.3% and 7.7% (n = 5), respectively. This method was applied successfully to analysis of food samples without interference peaks. The recoveries of aflatoxins spiked into nuts and cereals were >80%, and the relative standard deviations were <11.2%. Aflatoxins were detected at <10 ng/g in several commercial food samples.  相似文献   

17.
The potential usefulness of terbium(III) as reagent for the luminescent determination of flumequine residues in food samples has been studied using both fluorescence (FL) and time-resolved (TR) modes and both batch (B) and integrated liquid chromatography (LC)/derivatisation approaches. The system was optimised in each instance to establish the analytical features of the four methods. The dynamic ranges of the calibration graphs, obtained with standard solutions of flumequine, were (ng mL−1): B-FL 0.18-600; B-TR 2.4-150; LC-FL 3.7-1000 and LC-TR 52-3000. The detection limits were also obtained giving the following values (ng mL−1): B-FL 0.055; B-TR 0.7; LC-FL 1.1 and LC-TR 15. The precision, expressed as the percentage of relative standard deviation, was equal or lower than 5.1% in all instances. The LC methods, which avoid the interference of other quinolone antibiotics, were applied to the analysis of chicken muscle and liver, and whole milk samples. The sample pre-treatment only consisted of a deproteinisation step. The validation procedure for the analysis of samples was carried out using EC recommendations, and the decision limit and detection capability were calculated. The recoveries obtained ranged from 95.0% to 103.8%.  相似文献   

18.
The purpose of this study is to establish an easy and accurate method for the determination of bisphenol A (BPA) in the human serum. The samples were applied to the C18 solid phase extraction (SPE) column for clean up of samples. The BPA is conjugated with tetrabutylammonium hydrogen sulfate as the counter ion in alkali solution. The ion paired BPA is moves from the aqueous phase to the organic phase as an ion paired extraction. BPA extracted from human serum were derivatized with pentafluorobenzyl bromide (PFBBr). The derivative was analyzed by gas chromatography (GC)/mass spectrometry (MS) using negative chemical ionization (NCI). The instrumental detection limit of BPA was 5 pg/ml (10 fg). The instrumental response between 0.01 and 100 pg/ml of BPA standards was linear (r2=0.998). The recovery of BPA spiked into human serum was 101.0±4.63 (1 pg/ml) and 100.9±3.75 (10 pg/ml), respectively. The concentration of BPA in the human serum from 20 individuals was 0.54 pg/ml.  相似文献   

19.
Triethyloxonium tetrafluoroborate derivatization combined with direct headspace (HS) or SPME-gas chromatography-mass spectrometry (GC-MS) is proposed here for the simultaneous determination of nitrite and nitrate in seawater at micromolar level after conversion to their corresponding volatile ethyl-esters (EtO-NO and EtO-NO2). Isotopically enriched nitrite [15N] and nitrate [15N] are employed as internal standards and for quantification purposes. HS-GC-MS provided instrumental detection limits of 0.07 μM NO2 and 2 μM NO3. Validation of the methodology was achieved by determination of nitrite and nitrate in MOOS-1 (Seawater Certified Reference Material for Nutrients, NRC Canada), yielding results in excellent agreement with certified values. All critical aspects connected with the potential inter-conversion between nitrite and nitrate (less than 10%) were evaluated and corrected for by the use of the isotopically enriched internal standard.  相似文献   

20.
Feres MA  Reis BF 《Talanta》2005,68(2):422-428
In this work, a downsized flow set up designed based on multicommutation concept for photometric determination of iron(II)/iron(III) and nitrite/nitrate is surface water is described. The flow system network comprised a set of three-way solenoid valves, reaction coil and a double-channel flow cell, which were nested in order to obtain a compact and small-size instrument. To accomplish the downsizing requirement light source (LED) and radiation detection (phototransistor) were coupled to the flow cell. In order to demonstrated the effectiveness of the system, the photometer methods based on Griess reaction and 1-10-phenantroline for nitrite and iron(II) determination, respectively, were selected. Under computer control the set up provided facilities to handle four reagent solutions employing a single pumping channel, thus permitting also the determination of nitrate and iron(III) after its reduction to nitrite and to iron(II), respectively. The overall system performance was demonstrated working several days running standard solution, no significant variation of base line, linear response range and slop (less than 1%) were observed. The usefulness of the downsized system was ascertained by analyzing a set of surface water. Aiming to access the accuracy sample were also analyzed employing reference procedures and no significant difference at 95% confidence level were observed for the four analytes. Other profitable features such as analytical throughput of 40 determination per hour; relative standard deviation of 1%; linear response range between 50 and 300 μg l−1 for nitrite and nitrate, 0.5-6.0 mg l−1 iron(II) and iron(III); low reagent consumption 75 μg for nitrate/nitrite and 0.6 mg for iron(II)/iron(III) per determination; and 2.4 ml waste generation per determination were also achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号