首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
When used in traditional pool-boiling type refrigeration cycles, non-azeotropic mixed refrigerants tend to result in a reduced efficiency compared to pure refrigerants. This results from the composition shift effect, which distributes the mixture components: concentrating the more volatile component in the high pressure part of the cycle, and the less volatile component in the low pressure part. The obvious effect of this is to increase the compression ratio relative to a single component. This article investigates a way of manipulating the composition change of a refrigerant mixture, using two components of similar volatility, in order to reduce the compression ratio. Counter-current vapour–liquid contact is used in a “refrigeration column”, which is combined with a distillation column. The cycle is able to exploit heat sources below 100°C as input to the distillation column and the designer is able to optimise the consumption of compressor power and distillation heat input.  相似文献   

2.
A combined-cycle refrigeration system (CCRS) that comprises a conventional refrigeration and air-conditioning system using mechanical compressor (RAC/MC) and an ejector-cooling cycle (EJC) is proposed and studied. The EJC is driven by the waste heat from the RAC/MC and acts as the bottom cycle of the RAC/MC. A system analysis shows that the COP of a CCRS is significantly higher than a single-stage refrigeration system. Improvement in COP can be as high as 18.4% for evaporating temperature of the RAC/MC Te at −5°C. A prototype of the CCRS was built and tested in the present study. Experimental results show that at Te=−4.5°C, COP is improved by 14% for a CCRS. For Te at 5°C, COP can be improved by 24% for a CCRS with higher condensing temperature of the RAC/MC. The present study shows that the CCRS using the ejector-cooling cycle as the bottom cycle of the RAC/MC is viable. Further improvement in COP is possible since the prototype is not designed and operated at an optimal condition.  相似文献   

3.
In this paper, the thermoeconomic theory is applied to the economic optimization of a single effect water/LiBr vapour absorption refrigeration system for air-conditioning application, aimed at minimizing its overall operation and amortization cost. The mathematical and numerical techniques based optimization of thermal system is not always possible due to plant complexities. Therefore, a simplified cost minimization methodology is applied to evaluate the economic costs of all the internal flows and products of the system by formulating exergoeconomic cost equations. Once these costs are determined, the system is thermoeconomically evaluated to identify the effects of design variables on costs and enables to suggest values of design variables that would make the overall system cost effective. Finally, an approximate optimum design configuration is obtained by means of sequential local optimization of the system, carried out unit by unit. The result compares this optimum with the base case and shows percentage variations in the system's operation and amortization cost.  相似文献   

4.
In this article, a general definition of the process average temperature has been developed, and the impact of the various dissipative mechanisms on 1/COP of the chiller evaluated. The present component-by-component black box analysis removes the assumptions regarding the generator outlet temperature(s) and the component effective thermal conductances. Mass transfer resistance is also incorporated into the absorber analysis to arrive at a more realistic upper limit to the cooling capacity. Finally, the theoretical foundation for the absorption chiller T–s diagram is derived. This diagrammatic approach only requires the inlet and outlet conditions of the chiller components and can be employed as a practical tool for system analysis and comparison.  相似文献   

5.
This paper describes a novel cycle which uses a steam ejector to enhance the concentration process by compressing the vapour from the lithium bromide solution to a state that it can be used to re-heat the solution from which it came. The energy efficiency and the performance characteristics of the novel cycle are theoretically investigated in this paper. The theoretical results show that the coefficient of performance (COP) of the novel cycle is better than the conventional single-effect absorption cycle. The characteristics of the cycle performance show its promise in using high temperature heat source at low cost.  相似文献   

6.
In ammonia–water absorption refrigeration systems a purification process to reduce the water content in the vapour leaving the generator is required. During this process the water content in the vapour must be reduced to a minimum, otherwise it tends to accumulate in the evaporator and strongly deteriorates the efficiency of the system. The vapour purification can be carried out by partial condensation, by establishing a liquid–vapour counter flow or by combining both methods. In systems with partial condensation, the distillation column can be composed of one or more rectifiers using different cooling mediums, and the rectifying and stripping sections. In complete condensation systems only the rectifying and stripping sections can be used. Therefore different distillation column arrangements should be considered. This paper presents a study of several distillation column configurations for single stage ammonia–water absorption refrigeration systems with partial and complete condensation. In order to evaluate and compare the different configurations, a parameter that indicates the ratio of the ammonia vapour concentration increase in each part of the column to the total ammonia purification has been defined. The analysis has been based on the system COP. Finally the efficiency in each part of the column has been calculated to estimate its design requirements.  相似文献   

7.
The hydraulic refrigeration system (HRS) is a vapor-compression system that accomplishes the compression and condensation of the refrigerant in a unique manner, by entraining refrigerant vapor in a down-flowing stream of water and utilizing the pressure head of the water to compress and condense the refrigerant. A multi-stage HRS was designed, fabricated, and tested using n-butane as the refrigerant. In general, both the refrigeration rate and the coefficient of performance (COP) increased with a corresponding decrease in the compression fluid temperature of the third and final stage. The refrigeration rate and COP were also found to increase with a corresponding increase in evaporator temperature. The predictions of an enhanced model incorporating two-phase hydraulic losses show excellent agreement with the experimental data with a maximum error of ±20%. The results of the experimental investigation indicate that the HRS offers an attractive and feasible alternative to conventional vapor-compression systems, especially in applications where direct-contact heat exchange in the evaporator is desirable.  相似文献   

8.
Jet-refrigeration cycles seem to provide an interesting solution to the increasing interest in environment protection and the need for energy saving due to their low plant costs, reliability and possibility to use water as operating fluid. A steam/steam ejector cycle refrigerator is investigated introducing a two-stage ejector with annular primary at the second stage. The steady_state refrigerator, exchanging heat with the water streams at inlet fixed temperatures at the three shell and tube heat exchangers, evaporator, condenser and generator, is considered as an open system. Heat transfer irreversibilities in the heat exchangers and external friction losses in the water streams are considered, ignoring the internal pressure drop of the vapor. A simulation program numerically searches the maximum COP at given external inlet fluid temperatures as a function of mass flows, dimensions and temperature differences in the heat exchangers. The code gives the ejector and heat exchangers design parameters.  相似文献   

9.
An adsorption cooling system was developed and tested and various operation procedures have been tried. The experimental results show that the heat recovery operation between two adsorption beds will increase the COP by about 25% if compared with one adsorber basic cycle system. It was also proved that mass recovery is very effective for heat recovery adsorption cooling operation, which may help to obtain a COP increase of more than 10%. Theoretical analyses on the COP have been completed for various heat and mass recovery cycles, such as basic intermittent adsorption cycle, continuous two-adsorber heat recovery cycle, mass recovery cycle, mass recovery with sensible heat recovery, and mass recovery with both sensible heat and heat of adsorption recovery. The theoretical results are in good agreement with experimental values. Based upon the developed theoretical model, it is possible to predict the COP for various operation procedures of a real adsorption cooling system.  相似文献   

10.
Simulation results of triple-effect absorption cycles   总被引:1,自引:0,他引:1  
A simulation analysis was carried out for three kinds of triple-effect absorption cycles of parallel-flow, series-flow and reverse-flow using a newly developed simulation program. The cycles investigated in this paper are similar to the alternate double-condenser coupled cycles of Grossman. The coefficient of performance, the maximum pressure and the maximum temperature of each cycle were calculated. The sensitivity analysis of UA of each component was also carried out. The results show that the parallel-flow cycle yields the highest coefficient of performance among the cycles, while the maximum pressure and temperature in the reverse-flow cycle are lower than those of other cycles.  相似文献   

11.
Experimental investigation of mass recovery adsorption refrigeration cycle   总被引:1,自引:0,他引:1  
The study investigates the performance of silica gel–water adsorption refrigeration cycle with mass recovery process by experimental prototype machine. In an adsorption refrigeration cycle, the pressures in adsorber and desorber are different. The mass recovery cycle utilizes the pressure difference to enhance the refrigerant mass circulation. Moreover, novel cycle was proposed for improvement of cooling output. In our previous study, simulation analysis shows that mass recovery cycle has the advantage over conventional single-stage. Experiments with prototype machine were conducted to investigate the performance improvement of mass recovery cycle in the present paper. Specific cooling power (SCP) and coefficient of performance (COP) were calculated with experimental data to analyze the influences of operating conditions. The proposed cycle was compared with the single-stage cycle in terms of SCP and COP. The results show that SCP of mass recovery cycle is superior to that of conventional cycle and mass recovery cycle is effective with low temperature heat source.  相似文献   

12.
A refrigeration/heat-pump system based on a number of simple tubular adsorption modules is described. A single module is comprised of a generator and a receiver/condenser/evaporator. A single generator consisting of a 12.7 mm stainless steel tube lined with 3 mm of monolithic active carbon has been manufactured. A complete module has been tested in a simple rig, which subjects it to alternating hot and cold airstreams, desorbing and adsorbing ammonia. A complete system, consisting of 32 modules has been modelled in detail and its predicted performance is presented. Key parameters have been varied and their effect on the performance discussed.  相似文献   

13.
The consequences of the oil rejected by the compressor of a vapour-compression refrigeration system on the operation of the evaporator and condenser are analysed. The modelled prototype uses the mixture of HFC R410A and a synthetic polyolester (POE) oil. The rise of the amount of lubricant circulating in the system leads to a progressive change in the behaviour of the mixture of refrigerant and oil that, for the higher oil mass fraction, evolves like a zeotropic mixture. One also observes that the presence of lubricant is generally associated with a fall of the performances of the heat exchangers, except however in the evaporator where an optimum is observed when the quantity of oil is equal to 0.1% of the total mass of the mixture. Some conclusions are drawn about the choice of correlations for the calculation of the refrigerant side heat transfer coefficient in a plate evaporator.  相似文献   

14.
This paper addresses the problem of absorption of refrigerant vapor in a stagnant layer of lubricant oil. The bulk motion of the solute is described in terms of apparent diffusion coefficients that encompass both molecular diffusion and possible macroscopic motion induced by liquid density instability and surface tension. In absorption of refrigerant mixtures, diffusion in the vapor and liquid phases are coupled with a thermodynamic model for interfacial equilibrium. Results are compared with experimental data available in the literature for absorption of several refrigerants in polyol ester oil (POE68). The adequacy of the formulation is assessed in the light of its basic assumptions and performance of the model.  相似文献   

15.
The objectives of this paper are to analyze a combined heat and mass transfer for an ammonia–water absorption process, and to carry out the parametric analysis to evaluate the effects of important variables such as heat and mass transfer areas on the absorption rate for two different absorption modes — falling film and bubble modes. A plate heat exchanger with an offset strip fin (OSF) in the coolant side was used to design the falling film and the bubble absorber. It was found that the local absorption rate of the bubble mode was always higher than that of the falling film model leading to about 48.7% smaller size of the heat exchanger than the falling film mode. For the falling film absorption mode, mass transfer resistance was dominant in the liquid flow while both heat and mass transfer resistances were considerable in the vapor flow. For the bubble absorption mode, mass transfer resistance was dominant in the liquid flow while heat transfer resistance was dominant in the vapor region. Heat transfer coefficients had a more significant effect on the heat exchanger size (absorption rate) in the falling film mode than in the bubble mode, while mass transfer coefficients had a more significant effect in the bubble mode than in the falling film mode.  相似文献   

16.
In recent years the interest in cooling machines or heat pumps combining the principles of compression and sorption technology is increasing. The reason is that both technologies have specific drawbacks which can be overcome by the combination. Our discussion is centred around absorption cycles which use a compressor, and, consequently, an input of a significant amount of mechanical work in addition to heat. In most publications cycles of this kind are discussed in terms of one single COP as usual in the refrigeration industry. This, however, is wrong from a thermodynamic, and misleading from a technical and economical point of view. In order to highlight the need for a strict thermodynamic approach, a fundamental difference between distinct kinds of work input, namely “recoverable work”, “dissipative work” and “heat transformation work” is discussed in the first part of the paper. In the second part it is shown how the input of both work and heat into a energy conversion system has to be handled with both mechanical and thermal COP. The method is thermodynamically sound and straightforward, technically feasible and easy to apply, and most quickly transferred into economical terms. In the third part, a practical example of a compression–absorption hybrid is investigated.  相似文献   

17.
This paper focuses on cascading an ideal vapor compression cycle and determining the optimal intermediate temperatures based on the entropy generation minimization method. Only superheating and throttle losses of the cycle are considered since they are inherent to the ideal vapor compression refrigeration cycle. The second law equations have been developed in terms of specific heats and temperature ratios with the intent of reducing involved property modeling. Also the entropy generation was expressed in terms of a single independent variable and minimized to develop an advanced rule for selecting optimum intermediate temperatures. Results for a cascade system operating between reduced temperatures of 0.684 and 0.981 with R-134a as the working fluid are presented. The approximate method presented here predicted the optimum intermediate reduced temperature for a two-stage system to be 0.88, a difference of 2% from the optimum. The method presented was a much better predictor of the optimum temperature than the geometric mean method which was 0.82, a difference of 5% from the optimum. The entropy generation distribution of the optimum solution was investigated. For a two-stage system, the lower stage and higher stage entropy generation was 44% and 56%, respectively. In comparison to the single stage, the two-stage reduced losses by 78%.  相似文献   

18.
A diffusion absorption refrigeration (DAR) cycle is driven by heat and utilizes a binary solution of refrigerant and absorbent as working fluid, together with an auxiliary inert gas. Commercial DAR systems operate with ammonia–water solution and hydrogen or helium as the inert gas. In this work, the performance of a simplified DAR system working with an organic absorbent (DMAC – dimethylacetamide) and five different refrigerants and helium as inert gas was examined numerically, with the aim of lowering the generator temperature and system pressure along with a non-toxic refrigerant The refrigerants were: chlorodifluoromethane (R22), difluoromethane (R32), 2-chloro-1,1,1,2-tetrafluoroethane (R124), pentafluoroethane (R125) and 1,1,1,2-tetrafluoroethane (R134a). The results were compared with the performance of the same system working with ammonia–water and helium. Similar behavior was found for all systems, regarding the coefficient of performance (COP) and rich and poor solution concentrations as functions of generator temperature. It was found that typical generator temperature with the new substances was 150 °C, yet lower COPs, higher evaporator temperatures and lower condensation temperature of about 40 °C governed these systems.  相似文献   

19.
In this paper, a new solution cycle in the double absorption heat transformer is presented and the thermodynamic performance of this new cycle is simulated based on the thermodynamic properties of aqueous solution of lithium bromide. The results show that this new cycle is superior to the cycle being studied by some researchers. This new solution cycle has a wider range of operation in which the system maintains the high value of COP and has larger temperature lifts and operation stability. The relationship between the absorber and the absorbing evaporator is more independent and this makes the operation and control of the system more easier.  相似文献   

20.
A refrigeration Carnot-type cycle based on isothermal compression and two reversible expansions is proposed. Although ideal, this cycle is close to a realistic one which could be designed with existing hardware.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号