首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 295 毫秒
1.
Brushes made of carbon fibers are used to improve the thermal conductivities of phase change materials packed around heat transfer tubes. The transient thermal responses measured in brush/n-octadecane composites essentially improve as the volume fraction of the fibers and the brush diameter increase. However, there is a critical diameter above which further improvement is not expected due to thermal resistance between the fibers and the tube surface. A two-dimensional heat transfer model describing anisotropic heat flow in the composite is numerically solved. The calculated transient temperatures agree well with the experimental. A simple model is also developed to predict the heat exchange rate between the composite and the heat transfer fluid. The values of the correction factors are identified on the basis of the results for the anisotropic model.  相似文献   

2.
基于焓法模型对水平管壳式相变蓄热装置热性能的增强进行研究,首先分析蓄热过程中传统管壳式装置内材料的传热及流动机理;然后引入椭圆元素并对比椭圆内管及外壳的强化传热效果;最后对热源温度、相变材料导热系数及初始温度对装置热性能的作用规律进行探讨。结果显示,椭圆外壳的强化传热效果优于内管,同等条件下,长短轴之比为2的椭圆外壳可使蓄热时间缩短53.5%。热源温度升高,椭圆外壳的强化传热效果进一步增强,相变材料的导热系数及初始温度对装置热性能的影响较小。  相似文献   

3.
针对热电联产机组供热期发电负荷受供热量限制,机组调峰能力下降、电力系统弃风弃光现象严重的问题,设计了一种新型蓄热式管壳换热器.利用相变材料蓄/放热过程中温度接近恒定、释放潜热量大等优点,选取石蜡为相交材料,换热器相交区作为换热单元,采用控制变量法,针对传热流体流速、相变材料导热系数及相变层厚度等关键因素,对换热单元的蓄...  相似文献   

4.
Flooded evaporators are widely used as compact cooling units to cool liquids. They consist of a shell-and-tube heat exchanger, with the fluid to cool flowing inside the tubes of the bundle and a refrigerant that evaporates over those tubes. Pool boiling on the external surface of the tubes is a very complex process, and therefore the boiling heat transfer coefficients (HTCs) should be determined experimentally. Copper and copper alloys tubes are commonly employed in such heat exchangers, due to their high thermal conductivity and relative low cost. On the other hand, refrigeration and air conditioning sectors are undergoing significant changes caused mainly by the necessity of replacing existing refrigerants with more environmentally friendly ones. This paper reports the experimental determination of the pool boiling HTCs of R-134a and R-417A blend on a smooth copper tube of 18.87 mm diameter, at two saturation temperatures of 10°C and 7°C. Although smooth tubes are not commonly used in shell-and-tube evaporators nowadays, it is a first approach to pool boiling of drop-in refrigerants. The experimental setup and data acquisition are described, the experimental procedure is explained, the data reduction methodology is detailed, and the results are presented and discussed.  相似文献   

5.
基于列管式换热器具有传热面积大、结构紧凑、操作弹性大等优点,使其在相变储能领域具有广阔的应用前景。本文建立一种新型列管式相变蓄热器模型,在不考虑自然对流的情况下,利用Fluent软件对相变蓄热器进行二维储热过程的数值模拟。本文主要研究斯蒂芬数、雷诺数、列管排列方式、肋片数以及相变材料的导热系数对熔化过程的影响,并对熔化过程中固液分界面的移动规律进行了分析。模拟结果表明,内肋片强化换热效果明显,特别是对应用低导热系数相变材料[导热系数小于1 W/(m·K)]的列管式蓄热器,相对于无肋片结构,加入肋片(Nfn=2)可缩短熔化时间52.6%。  相似文献   

6.
In the present study, the heat transfer performance and friction factor characteristics in a circular tube fitted with twisted wire brush inserts were investigated experimentally. The twisted wire brush inserts were fabricated with four different twisted wire densities of 100, 150, 200, and 250 wires per centimeter by winding a 1 mm diameter of the copper wire over a 5 mm diameter of two twisted iron core-rods. Heat transfer and friction factor data in tubes were examined for Reynolds number ranging from 7,200 to 50,200. The results indicated that the presence of twisted wire brush inserts led to a large effect on the enhancement of heat transfer with corresponding increase in friction factor over the plain tube. The Nusselt number and friction factor of using the twisted wire brush inserts were found to be increased up to 2.15 and 2.0 times, respectively, than those over the plain tube values. Furthermore, the heat transfer performance was evaluated to assess the real benefits of using those type of inserts and the performance was achieved 1.85 times higher compared to the plain tube based on the constant blower power. Finally, correlations were developed based on the data generated from this work to predict the heat transfer, friction factor, and thermal performance factor for turbulent flow through a circular tube fitted with the twisted wire brush inserts in terms of wire density (y), Reynolds number (Re), and Prandtl number (Pr).  相似文献   

7.
本文基于最小火积耗散热阻原理,在考虑相变材料导热热阻以及非稳态传热过程的基础上,对多级套管式相变蓄热系统的融化温度进行了数值优化,获得了最优融化温度分布。在此基础上,研究了相变材料导热系数和传热管长度对最优融化温度、火积耗散热阻和平均蓄热速率的影响。研究结果表明,与现有理论优化方法相比,本文提出的数值优化方法具有更好的适用性;优化后多级套管式相变蓄热系统可有效提高相变蓄热系统的平均蓄热速率,降低火积耗散热阻;随着相变材料导热系数增大和传热管长度增加,多级套管式相变蓄热系统最优融化温度的温差愈加明显,其强化传热性能呈上升趋势。  相似文献   

8.
This paper describes new type of solid sorption composite based on expanded graphite (EXG) and carbon fibers (CF). Process of production (including preparation of the components and molding) of the composite, as well as measurements of its heat transfer coefficient has been presented. Introduction of carbon fibers allowed to obtain thermal conductivity λ of about 13–15 W/mK in comparison to 6.5–9.2 W/mK for expanded graphite based only composites described in available literature. Thermal conductivity of the composite has been measured in cryostat using the axial stationary heat flow method. Temperature profiles for various thermal conductivities (ranging 0.3–16 W/mK) were numerically calculated and compared.The composite has been introduced in experimental single stage sorption heat pump system using CaCl2 – NH3 as working pair.  相似文献   

9.
The radiative properties and heat transfer in fiber-loaded silica aerogel composites were investigated using modified anomalous diffraction theory in a combined heat conduction and radiation model. The randomly parameterized 2-D fiber distribution was generated to simulate a very realistic material structure. The finite volume method was then used to solve a two flux radiation model and the steady-state energy equation to calculate the effective thermal conductivity of the composite. The numerical results provide theoretic guidelines for material designs with optimum parameters, such as the inclination angle, diameter and length-to-diameter ratio of the fibers. The results show that the fiber extinction coefficient increases as the fiber length-to-diameter ratio is reduced or the fiber inclination angle is increased. The effective thermal conductivity of the fiber-loaded aerogel can be reduced by reducing the fiber length-to-diameter ratio and the inclination angle and by moderately increasing the fiber volume fraction. The 4–6 μm diameter silicon fibers are optimum for high-temperature thermal insulation.  相似文献   

10.
The commercial CFD code FLUENT is used to investigate the effect of baffle orientation and of viscosity of the working fluid on the heat transfer and pressure drop in a shell-and-tube heat exchanger in the domain of turbulent flow. The shell-and-tube heat exchanger considered follows the TEMA standards and consists of 76 plane tubes with fixed outside diameter, which are arranged in a triangular pitch. Two baffle orientations as well as leakage flows are considered. In order to determine the effect of viscosity on heat transfer and pressure drop, simulations are performed for the working fluids air, water, and engine oil with Prandtl numbers in the range of 0.7 to 206. For each baffle orientation and working fluid, simulations are performed using different flow velocities at the inlet nozzle. Heat transfer and pressure drop are reported in order to describe the performance of vertically and horizontally baffled shell-and-tube heat exchangers. The heat transfer coefficient is described as modified shell-side Nusselt number, which is defined similar to the VDI method.  相似文献   

11.
岩土导热系数是地源热泵地埋管换热器的重要设计参数;测井单位深度换热量是地埋管换热器系统的设计依据。掌握工程区域岩土的热物性及换热性能,是保证地源热泵系统高效、稳定运行的关键。文章建立了现场测试岩土导热系数及换热量的方法,并结合沈阳浑南高新技术产业开发区某地源热泵工程,测试分析了岩土导热系数和测井单位深度换热量。结果表明,该区域的岩土具有较好的导热能力,适合采用地埋管地源热泵系统;在特殊地理条件下设计地源热泵系统方案前,应对拟建区域的地质条件进行全面勘探,以优选工程区域,为岩土热响应测试结果的可靠性提供保障。  相似文献   

12.
In spray type evaporators using a conventional overhead spray method, a dry-out phenomenon occurs on the lower surface of the evaporator tubes under high surface heat flux conditions, and thus the heat transfer performance of the evaporator system is seriously impaired. This study shows that in a compact triangular-pitch shell-and-tube evaporator, the dry-out problem can be delayed through the use of an interior spray method, in which each heater tube within the bundle is sprayed simultaneously by two nozzles. The experimental results reveal that the shell-side heat transfer coefficients obtained using the proposed spray technique are significantly higher than those achieved in a conventional flooded type evaporator. The results also show that the heat transfer performance improves as the saturation temperature decreases since the density and thermal conductivity of the sprayed liquid increase. Finally, it is shown that for a constant heat flux and saturation temperature, the heat transfer coefficient increases with an increasing refrigerant mass flow rate.  相似文献   

13.
《Applied Thermal Engineering》2007,27(5-6):1001-1008
In this paper, the heat transfer coefficient and pressure drop on the shell side of a shell-and-tube heat exchanger have been experimentally obtained for three different types of copper tubes (smooth, corrugated and with micro-fins). Also, experimental data has been compared with theoretical data available. Correlations have been suggested for both pressure drop and Nusselt number for the three tube types. A shell-and-tube heat exchanger of an oil cooler used in a power transformer has been modeled and built for this experimental work in order to investigate the effect of surface configuration on the shell side heat transfer as well as the pressure drop of the three types of tube bundles. The bundles with the same geometry, configuration, number of baffles and length, but with different external tube surfaces inside the same shell were used for the experiment. Corrugated and micro-fin tubes have shown degradation of performance at a Reynolds number below a certain value (Re < 400). At a higher Reynolds number the performance of the heat exchanger greatly improved for micro-finned tubes.  相似文献   

14.
利用无网格迦辽金(EFG)法建立正交各向异性相变材料的传热计算模型,基于该模型编程完成各向异性材料太阳能相变蓄热水箱和管壳式相变蓄热单元的相变传热分析,并探讨热导率因子和材料方向角对复合材料相变传热特性的影响.研究表明:在相同节点布置下EFG法的温度场和相界面计算精度均高于有限元法,EFG法在动态相界面追踪方面具有明显...  相似文献   

15.
《Applied Thermal Engineering》2000,20(17):1615-1648
An experimental comparison is made over a large range of Reynolds numbers (from 30 to 30,000) between two shell-and-tube heat exchangers having the same heat-transfer area and same number of bends, but different configurations: one has a helical configuration (regular flow), the other has a chaotic one (chaotic advection flow). Both are composed of 33 bends with circular tube cross section (inside diameter 23 mm) and are immersed in a closed shell. The working fluids are Newtonian with different Prandtl numbers (820, 230, 75 and 6.5) in order to cover the large-Reynolds-number range. The comparison is made by using a criterion L that takes into account thermal performance and energy expenditure. The results show that at low Reynolds numbers, heat transfer is higher and heating more homogeneous for chaotic advection flow, with no increase in energy expenditure. At high Reynolds numbers, the configuration has no influence on heat transfer. When the Prandtl number increases, the heat transfer increases. The flows have also been visualized by laser-induced fluorescence to assess the improvement of mixing in the chaotic configuration.  相似文献   

16.
This paper analyzes the effect of three different working fluids (ammonia, propane, and freon-114) on the size of OTEC heat exchangesrs and system performance. Seven different combinations of shell-and-tube heat exchangers are considered. For each combination, a simple computer model of the OTEC power system is used to compare the three fluids. The comparison is made on the basis of A/Wnet, where A is the total heat transfer area (evaporator plus condenser) and Wnet is the net power output of the plant. Overall, ammonia is shown to be the best fluid (i.e. it yields the lowest value of A/Wnet), although in some cases only by a small margin. The thermophysical property that gives ammonia its general superiority is its relatively high thermal conductivity. The paper also discusses heat exchanger design problems associated with liquid entrainment and boiling liquid superheat.  相似文献   

17.
A numerical simulation has been carried out to investigate the heat transfer enhancement in a shell-and-tube heat exchanger using a porous medium inside its shell and tubes, separately. A three-dimensional geometry with k-? turbulent model is used to predict the heat transfer and pressure drop characteristics of the flow. The effects of porosity and dimensions of these media on the heat exchanger's thermal performance and pressure drop are analyzed. Inside the shell, the entire tube bundle is wrapped by the porous medium, whereas inside the tubes the porous media are located in two different ways: (1) at the center of the tubes, and (2) attached to the inner wall of the tubes. The results showed that this method can improve the heat transfer at the expense of higher pressure drop. Evaluating the method showed that using porous media inside the shell, with particular dimension and porosity can increase the heat transfer rate better than pressure drop. Using this method inside the tubes leads to two diverse results: In the first configuration, pressure loss prevails over the heat transfer augmentation and it causes energy loss, whereas in the second configuration a great performance enhancement is observed.  相似文献   

18.
Fouling is a challenging, longstanding, and costly problem affecting a variety of heat transfer applications in industry. Mathematical models that aim at capturing and predicting fouling trends in shell-and-tube heat exchangers typically focus on fouling inside the tubes, while fouling on the shell side has generally been neglected. However, fouling deposition on the shell side may be significant in practice, impairing heat transfer, increasing pressure drops, and modifying flow paths. In this paper, a new model formulation is presented that enables capturing fouling on the shell side of shell-and-tube heat exchangers including the effect of occlusion of the shell-side clearances. It is demonstrated by means of an industrial case study in a crude oil refinery application. The model, implemented in an advanced simulation environment, is fitted to plant data. It is shown to capture the complex thermal and hydraulic interactions between fouling growth inside and outside of the tubes, the effect of fouling on the occlusion of the shell-side construction clearances, and to unveil the impact on shell-side flow patterns, heat transfer coefficient, pressure drops, and overall exchanger performance. The model is shown to predict the fouling behavior in a seamless dynamic simulation of both deposition and cleaning operations, with excellent results.  相似文献   

19.
《储能科学与技术》2017,(4):607-622
Phase change microcapsules can carry large amounts of heat and be dispersed into other mediums either as a solid composite or as slurry fluids without changes to their appearance or fluidity. These two standout features make phase change microcapsules ideal for use in thermal energy applications to enhance the efficiency of energy utilisation. This review paper includes methods used for the encapsulation of phase change materials, especially the method suitable for large scale productions, the trends of phase change microcapsule development and their use in thermal energy applications in static and dynamic conditions. The effect of phase change microcapsules on convective heat transfer through addition to thermal fluids as slurries is critically reviewed. The review highlighted that so far the phase change microcapsules used mainly have polymeric shells, which has very low thermal conductivities. Their enhancement in convective heat transfer was demonstrated in locations where the phase change material experiences phase change. The phase change results in the slurries having higher apparent local specific heat capacities and thus higher local heat transfer coefficients. Out of the phase change region, no enhancement is observed from the solid microcapsule particles due to the low specific heat capacity and thermal conductivity of the phase change microcapsules compared to that of water, which is normally used as slurry media in the test. To further the research in this area, phase change microcapsules with higher specific heat capacity, higher thermal conductivity and better shape stability need to be applied.  相似文献   

20.
Clothing materials may be considered composite materials composed of fiber, air, and moisture. For this paper, effective thermal conductivities of wet clothing materials were analyzed numerically using a proposed heat transfer model. The following simplifications were introduced. The clothing material fiber is woven with a single yarn, there is no air movement between fibers, and mass transfer is neglected. Numerical calculations were made using finite difference equations for steady three-dimensional heat conduction for several composite materials representing wet clothing materials. The main results obtained were as follows. The effective thermal conductivity of wet clothing material increases as the thermal conductivity of the yarn and the moisture content increase. We found that our numerical results agree qualitatively with those previously measured. The effective thermal conductivity of a wet layered material depends on the distribution of moisture and attains a maximum in the wet layer. © 1998 Scripta Technica, Heat Trans Jpn Res, 27(3): 243–254, 1998  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏