首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A recently developed analytical optical coherence tomography (OCT) model [Thrane et al., J. Opt. Soc. Am. A 17, 484 (2000)] allows the extraction of optical scattering parameters from OCT images, thereby permitting attenuation compensation in those images. By expanding this theoretical model, we have developed a new method for extracting optical scattering parameters from multilayered tissue structures in vivo. To verify this, we used a Monte Carlo (MC) OCT model as a numerical phantom to simulate the OCT signal for heterogeneous multilayered tissue. Excellent agreement between the extracted values of the optical scattering properties of the different layers and the corresponding input reference values of the MC simulation was obtained, which demonstrates the feasibility of the method for in vivo applications. This is to our knowledge the first time such verification has been obtained, and the results hold promise for expanding the functional imaging capabilities of OCT.  相似文献   

2.
Saxer CE  de Boer JF  Park BH  Zhao Y  Chen Z  Nelson JS 《Optics letters》2000,25(18):1355-1357
A high-speed single-mode fiber-based polarization-sensitive optical coherence tomography (PS OCT) system was developed. With a polarization modulator, Stokes parameters of reflected flight for four input polarization states are measured as a function of depth. A phase modulator in the reference arm of a Michelson interferometer permits independent control of the axial scan rate and carrier frequency. In vivo PS OCT images of human skin are presented, showing subsurface structures that are not discernible in conventional OCT images. A phase retardation image in tissue is calculated based on the reflected Stokes parameters of the four input polarization states.  相似文献   

3.
We report on a modification of optical coherence tomography (OCT) that allows one to measure small phase differences between beams traversing adjacent areas of a specimen. The sample beam of a polarization-sensitive low-coherence interferometer is split by a Wollaston prism into two components that traverse the object along closely spaced paths. After reflection at the various sample surfaces, the beams are recombined at the Wollaston prism. Any phase difference encountered between the two beams is converted into a change of polarization state of the recombined beam. This change is measured, and the resulting signals are converted to differential phase-contrast OCT images. The first images obtained from simple test objects allowed us to determine path-difference gradients with a resolution of the order of 5 x 10(-5) .  相似文献   

4.
An improved polarization-sensitive optical coherence tomography (OCT) system is developed and used to measure birefringence in porcine myocardium tissue and produce two-dimensional birefringence mapping of the tissue. Signal-to-noise issues that cause systematic measurement errors are analyzed to determine the regime in which such measurements are accurate. The advantage of polarization-sensitive OCT systems over standard OCT systems in avoiding image artifacts caused by birefringence is also demonstrated.  相似文献   

5.
Jiao S  Yu W  Stoica G  Wang LV 《Optics letters》2003,28(14):1206-1208
An optical-fiber-based multichannel polarization-sensitive Mueller optical coherence tomography (OCT) system was built to acquire the Jones or Mueller matrix of a scattering medium, such as biological tissue. For the first time to our knowledge, fiber-based polarization-sensitive OCT was dynamically calibrated to eliminate the polarization distortion caused by the single-mode optical fiber in the sample arm, thereby overcoming a key technical impediment to the application of optical fibers in this technology. The round-trip Jones matrix of the sampling fiber was acquired from the reflecting surface of the sample for each depth scan (A scan) with our OCT system. A new rigorous algorithm was then used to retrieve the calibrated polarization properties of the sample. This algorithm was validated with experimental data. The skin of a rat was imaged with this fiber-based system.  相似文献   

6.
A polarization-sensitive Fourier domain optical coherence tomography (PS-FD-OCT) system has been developed. By using a two-dimensional CCD camera, this PS-FD-OCT simultaneously obtains two spectral interferograms corresponding to orthogonal polarization components of a probing beam. FD-OCT avoids axial mechanical scanning, therefore, two OCT images are obtained by a single lateral scanning. This system requires only two one-dimensional scannings for determining the Müller matrix images of a sample. In the Müller matrix images, the birefringence properties of the inner surface of a porcine esophagus are revealed.  相似文献   

7.
We describe a novel imaging technique, second-harmonic-generation optical coherence tomography (SHOCT). This technique combines the spatial resolution and depth penetration of optical coherence tomography (OCT) with the molecular sensitivity of second-harmonic-generation spectroscopy. As a consequence of the coherent detection required for OCT, polarization-resolved images arise naturally. We demonstrate this new technique on a skin sample from the belly of Icelandic salmon, acquiring polarization-resolved SHOCT and OCT images simultaneously.  相似文献   

8.
Noisy structure of optical coherence tomography (OCT) images of turbid medium contains information about spatial variations of its optical parameters. We propose analytical model of statistical characteristics of OCT signal fluctuations from turbid medium with spatially inhomogeneous coefficients of absorption and backscattering. Analytically predicted correlation characteristics of OCT signal from spatially inhomogeneous medium are in good agreement with the results of correlation analysis of OCT images of different biological tissues. The proposed model can be efficiently applied for quantitative evaluation of statistical properties of absorption and backscattering fluctuations basing on correlation characteristics of OCT images.  相似文献   

9.
We have developed a dual-channel optical coherence tomography-Indocyanine Green dye (OCT-ICG) fluorescence system based on a previously reported ophthalmic OCT confocal imaging system. The confocal channel is tuned to the fluorescence wavelength range of the ICG, and light from the same optical source is used to generate the OCT image and to excite the ICG fluorescence. The system enables the clinician to visualize simultaneously en face OCT slices and corresponding ICG angiograms of the ocular fundus, displayed side by side. C-scan (constant depth) and B-scan (cross section) images are collected by a fast en face scan (T scan). The pixel-to-pixel correspondence between the OCT and angiography images allows the user to capture OCT B scans precisely at selected points on the ICG confocal images.  相似文献   

10.
We report a dual-modal device capable of sequential acquisition of Raman spectroscopy (RS) and optical coherence tomography (OCT) along a common optical axis. The device enhances application of both RS and OCT by precisely guiding RS acquisition with OCT images while also compensating for the lack of molecular specificity in OCT with the biochemical specificity of RS. We characterize the system performance and demonstrate the capability to identify structurally ambiguous features within an OCT image with RS in a scattering phantom, guide acquisition of RS from a localized malignancy in ex vivo breast tissue, and perform in vivo tissue analysis of a scab.  相似文献   

11.
We study the influence of multiple backscattering on optical coherence tomography (OCT) images or pulsed-sounding images of layered turbid media. A method for calculating the signal of various orders of backscattering is proposed. The retarding effects of OCT-signal dropping are analyzed. The contrast attenuation of an image of a layered medium due to multiple backscattering is examined. The blurring effect of an image of the back boundary of a scattering layer, caused by a delay of multiply scattered photons compared with single-scattered ones, is studied theoretically and experimentally using an OCT device.  相似文献   

12.
OCT图像法测量折射率   总被引:2,自引:0,他引:2  
基于光程匹配原理提出了一种用光学相干断层成像(OCT)系统获得的图像测量样品折射率的方法。通过分析光程匹配原理,给出用OCT图像法测量样品折射率的原理及过程。以玻璃载波片和黄瓜组织为样品进行实验。实验结果表明,用OCT图像法获得的载玻片和黄瓜组织的折射率测量值分别为1.499和1.353,与发表或已知的折射率结果相吻合,测试结果的随机误差可小于0.01。另外,使用OCT图像法通过短时间所采集的两幅图像可对横向扫描任意位置的折射率同时进行测量。该方法进一步简化了基于光程匹配原理的折射率测量法的过程,缩短了测量时间,是一种快速测量样品折射率的实用方法。  相似文献   

13.
Optical coherence tomography (OCT) relies on interference between a polarized reference and the target reflection. Thus, it has generally been impossible to detect any unpolarized part in the signal. Here, we demonstrate a scheme that overcomes this limitation. Using a combination of heterodyning and filtering, we realize a polarization-sensitive OCT system capable of measuring the full Stokes vector, including the depolarized part. Based on such a system, we perform full Stokesmetric imaging of different layers in a porcine tendon sample. The complete 4 × 4 backscattering Muellermetric images of one layer are acquired and investigated.  相似文献   

14.
We investigated the use of optical coherence tomography (OCT) to measure several materials immersed in optical adhesives. The effects of variations in the concentration, physical characteristics, and thickness of the materials were studied, and these parameters were found to significantly affect the OCT measurement. The materials were selected for their distinct spectral properties in the infrared region. To ensure reliability, we acquired images using a scanning electron microscope after performing the semiconductor production process. We verified the feasibility of the application of OCT for defect inspection and product verification of touch-screen panels.  相似文献   

15.
We have demonstrated functional optical coherence tomography (fOCT) for neural imaging by detecting scattering changes during the propagation of action potentials through neural tissue. OCT images of nerve fibers from the abdominal ganglion of the sea slug Aplysia californica were taken before, during, and after electrical stimulation. Images acquired during stimulation showed localized reversible increases in scattering compared with those acquired before stimulation. Motion-mode OCT images of nerve fibers showed transient scattering changes from spontaneous action potentials. These results demonstrate that OCT is sensitive to the optical changes in electrically active nerve fibers.  相似文献   

16.
Park BH  Pierce MC  de Boer JF 《Optics letters》2004,29(24):2873-4; discussion 2875-7
We comment on the recent Letter by Jiao et al. [Opt. Lett. 28, 1206 (2003)] in which a polarization-sensitive optical coherence tomography system was presented. Interrogating a sample with two orthogonal incident polarization states cannot always recover birefringence correctly. A previously presented fiber-based polarization-sensitive system was inaccurately characterized, and its method of eliminating the polarization distortion caused by single-mode optical fiber was presented earlier by Saxer et al. [Opt. Lett. 25, 1355 (2000)].  相似文献   

17.
Xu C  Ye J  Marks DL  Boppart SA 《Optics letters》2004,29(14):1647-1649
Optical coherence tomography (OCT) images of biological tissues often have low contrast. Spectroscopic optical coherence tomography (SOCT) methods have been developed to enhance contrast but remain limited because most tissues are not spectrally active in the frequency bands of laser sources commonly used in OCT. Near-infrared (NIR) dyes with absorption spectra features within the OCT source spectrum can be used for enhancing contrast in this situation. We introduce and demonstrate the use of NIR dyes as contrast agents for SOCT. Contrast-enhanced images are compared with fluorescence microscopy, demonstrating a link between SOCT and fluorescence imaging.  相似文献   

18.
Moneron G  Boccara AC  Dubois A 《Optics letters》2007,32(14):2058-2060
We present a polarization-sensitive full-field optical coherence tomography system that can produce high-resolution images of the linear retardance and reflectivity properties of biological media. En face images can be delivered at a frame rate of 3.5 Hz by combination of interferometric images acquired by two CCD cameras in an interference microscope illuminated with a tungsten halogen lamp. Isotropic spatial resolution of approximately 1.0 microm is achieved. The technique is demonstrated on ex vivo muscle tissues.  相似文献   

19.
The basic principles and possibilities of optical coherence tomography (OCT) as a method for the investigation of pathologies in medical diagnostics are outlined. We discuss the OCT method limitations and issues related to the need for improving the resolution of optical tomographs. The prospects are considered for developing the OCT methods based on probing with diffraction-free light beams.  相似文献   

20.
Forward-imaging instruments for optical coherence tomography   总被引:2,自引:0,他引:2  
We discuss the design and implementation of forward-imaging instruments for optical coherence tomography (OCT), which require the delivery, scanning, and collection of single-spatial-mode optical radiation. A hand-held surgical probe for use in open surgery can provide cross-sectional images of subsurface tissue before surgical incisions are made. A rigid laparoscope for minimally invasive surgical OCT imaging provides a simultaneous enface view of the area being imaged. OCT imaging is demonstrated on in vitro human specimens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号