首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, the composite carbon-polyvinylchloride (C-PVC) was used as an electrode for the detection of dopamine, ascorbic acid, uric acid and their mixtures by differential pulse voltammetry (DPV). The results showed that the untreated C-PVC electrode was selective and stable for the oxidation of dopamine in a mixture containing uric acid and an excess of ascorbic acid in acidic medium. The pre-treated C-PVC electrode in a neutral medium exhibited good resolution of the mixture components in the micro molar concentration range of DA. The ageing of the C-PVC electrode during longer time periods did not affect the peak potential and the detection of dopamine, uric acid and ascorbic acid in 0.1 M H2SO4. The practical analytical utility of the C-PVC electrode was demonstrated by the measurement of uric acid in human urine and serum samples without any preliminary pre-treatment.  相似文献   

2.
A gold electrode surface was modified using a dinuclear copper complex [CuII2 (Ldtb)(μ-OCH3)](BPh4) and then coated with a chitosan film. This biomimetic polymer film-coated electrode was employed to eliminate the interference from ascorbic acid and uric acid in the sensitive and selective determination of dopamine. The optimized conditions obtained for the biomimetic electrode were 0.1 M phosphate buffer solution (pH 8.0), complex concentration of 2.0 × 10−4 M, 0.1% of chitosan and 0.25% of glyoxal. Under the optimum conditions, the calibration curve was linear in the concentration range of 4.99 × 10−7 to 1.92 × 10−5 M, and detection and quantification limits were 3.57 × 10−7 M and 1.07 × 10−6 M, respectively. The recovery study gave values of 95.2-102.6%. The lifetime of this biomimetic sensor showed apparent loss of activity after 70 determinations. The results obtained with the modified electrode for dopamine quantification in the injection solution matrix were in good agreement with those of the pharmacopoeia method.  相似文献   

3.
The electrochemical behavior of ascorbic acid (AA) and uric acid (UA) at the surface of a carbon-paste electrode modified with incorporate thionine-nafion ion-paired was thoroughly investigated. The results show the presence of nafion inside the matrix of modified electrode, because of the effective ion-pairing and hydrophobic interactions, significantly enhances the stability of thionine as an electron mediator inside the modified electrode. A high reproducibility in voltammetric response to analyte species results because of this enhancement. The cyclic voltammetric studies using the prepared modified electrode show the best electrocatalytic property for the electro-oxidation of AA and noticeable decrease in anodic overpotential. Although the catalytic effect is observed to some extent for UA, the property cannot be seen for other biologically reducing agents such as cysteine. The voltammetric studies using the thionine-nafion modified electrode show two well-resolved anodic peaks for AA and UA, revealing the possibility of the simultaneous electrochemical detection of these compounds in the presence of biological thiols. The detection limits of 5 × 10−8 and 5 × 10−7 M were obtained in differential pulse voltammetric (DPV) measurements for UA and AA, respectively. Spectrophotometric investigations were used to confirm the selective catalytic effect of thionine in oxidation of AA and to some extent, UA. The detection system is stable (R.S.D. for the slope of the calibration curves was less than 4% for six measurements in one month) and is of high selectivity for electro-oxidation of AA and UA in complex biological and clinical matrices. The prepared modified electrode is applied for the DPV measurement of AA in pharmaceutical preparations. Also, the electrode is used to determine UA in human urine and serum samples and recovery of the amounts of UA added to these complex samples.  相似文献   

4.
This paper describes the preparation, characterization and application of a composite electrode based on methylene blue adsorption to phosphorylated zirconia-silica mixed oxide particles prepared by a sol-gel process. This electrode electrocatalytically oxidizes ascorbic acid (AA), dopamine (DA) and uric acid (UA), allowing their simultaneous voltammetric detection. Well-defined and -separated oxidation peaks were observed by differential pulse voltammetry in a 0.35 mol l−1 Tris-HCl buffer solution (pH 7.4) containing 0.5 mol l−1 KCl. The anodic peak currents observed at −74, 94 and 181 mV increased with increasing concentrations of AA, DA and UA, respectively. Linear calibration plots were obtained over the range of 100-1600 μmol l−1 for ascorbic acid, 6-100 μmol l−1 for dopamine and 22-350 μmol l−1 for uric acid with detection limits of 8.3 ± 0.1, 1.7 ± 0.1 and 3.7 ± 0.2 μmol l−1, respectively. DA and UA concentrations could also be determined under conditions of excess AA (1 mmol l−1).  相似文献   

5.
Functionalized polypyrrole film were prepared by incorporation of [Fe(CN)6]4− as a doping anion, during the electropolymerization of pyrrole onto a carbon paste electrode in an aqueous solution by potentiostatic method. The electrochemical behavior of dopamine (DA) and ascorbic acid (AA) in one solution was studied at the surface of bare and modified carbon paste electrodes using cyclic voltammetry (CV), linear sweep voltammetry (LSV) and differntial pulse voltammetry (DPV) methods. The well separated anodic peaks for oxidation of DA and AA were observed at the surface of the modified carbon paste electrode under optimum condition (pH 6.00), which can be used for determination of these species simultaneously in mixture by LSV and DPV methods. The linear analytical curves were obtained in the ranges of 0.10-1.00 mM and 0.10-0.95 mM for ascorbic acid and 0.10-1.20 mM and 0.20-0.95 mM for dopamine concentrations using LSV and DPV methods, respectively. The detection limits (2σ) were determined as 3.38 × 10−5 M and 1.34 × 10−5 M of ascorbic acid and 3.86 × 10−5 M and 1.51 × 10−5 M of dopamine by CV and DPV methods.  相似文献   

6.
A modified carbon-paste electrode (CPE) is prepared by incorporating thionine-nafion supported on multi-walled carbon nanotube (MWCNT). The electrochemical behavior of dopamine (DA) and ascorbic acid (AA) on the surface of the modified electrode is investigated by cyclic voltammetry (CV). The results show that thionine effectively immobilized in the matrix of the paste by using an appropriate mixture of nafion/MWCNT under the ultrasonic condition. On the other hand, presence of nafion enhances the stability of the thionine supported by MWCNT in the composite electrode and improves the reproducibility of the surface of the modified electrode under renewing process by polishing. The results of cyclic and differential pulse voltammetric investigations show that the modified electrode possesses an efficient electrocatalytic activity for the electrochemical oxidation of DA and AA and a peak potential separation nearly 379 mV is resulted for two compounds. The prepared modified electrode does not show any considerable response toward the electro-oxidation of sulfhydryl compounds, such as, cysteine, penicillamine and glutathione, revealing a good selectivity for voltammetric response to AA and DA in clinical and pharmaceutical preparations. The effective electrocatalytic property, excellent peak resolution and ability for masking the voltammetric responses of the other biologically reducing agents, make the modified electrode suitable for simultaneous and sensitive voltammetric detection of sub-micromolar amounts of AA and DA.  相似文献   

7.
The electrochemistry of dopamine (DA) was investigated by cyclic voltammetry (CV) and differential pulse voltammograms (DPV) at a glassy carbon electrode modified by the hybridization adducts of Fc-SWNTs. The electro-oxidation of DA could be catalyzed by Fc/Fc+ couple as a mediator and had a higher electrochemical response due to the unique carbon surface of carbon nanotubes. The anodic peaks of DA, ascorbic acid (AA) and uric acid (UA) in their mixture can be well separated by the prepared electrode. Under optimum conditions linear calibration graphs were obtained over the DA concentration range 5.0 × 10−6 to 3.0 × 10−5 M with a correlation coefficient of 0.9998 and a detection limit of 5.0 × 10−8 M based on the equation Cm = 3sb1/m. The modified electrode has been successfully applied for the assay of DA in human blood serum. This work provides a simple and easy approach to selectively detect DA in the presence of AA and UA.  相似文献   

8.
Multi walled carbon nanotube modified carbon-ceramic electrode (MWCNT/CCE) was employed for the simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA). The MWCNT/CCE displayed very good electrochemical catalytic activities with respect to CCE. The oxidation over-potentials of AA, DA and UA decreased dramatically, and their oxidation peak currents increased significantly at MWCNT/CCE compared to those obtained at the bare CCE. Differential pulse voltammetry was used for the simultaneous determination of AA, DA and UA in their ternary mixture. The peak separation between AA and DA, and DA and UA was large up to 205 and 160 mV, respectively. The calibration curves for AA, DA and UA were obtained in the range of 15.00-800.00, 0.50-100.00, and 0.55-90.00 μM, respectively. The detection limits (S/N = 3) were 7.71, 0.31, and 0.42 μM for AA, DA and UA, respectively.The present method was applied to the determination of AA, DA and UA in human serum and some commercial pharmaceutical samples, using standard adding method and the results were quite promising.  相似文献   

9.
A polymerized film of eriochrome black T (EBT) was prepared on the surface of a glassy carbon (GC) electrode in alkaline solution by cyclic voltammetry (CV). The redox response of the poly(EBT) film at the GC electrode appeared in a couple of redox peak in 0.1 M hydrochloride and the pH dependent peak potential was −55.1 mV/pH which was close to the Nernst behavior. The poly(EBT) film-coated GC electrode exhibited excellent electrocatalytic activity towards the oxidations of dopamine (DA), ascorbic acid (AA) and uric acid (UA) in 0.05 mM phosphate buffer solution (pH 4.0) and lowered the overpotential for oxidation of DA. The polymer film modified GC electrode conspicuously enhanced the redox currents of DA, AA and UA, and could sensitively and separately determine DA at its low concentration (0.1 μM) in the presence of 4000 and 700 times higher concentrations of AA and UA, respectively. The separations of anodic peak potentials of DA-AA and UA-DA reached 210 mV and 170 mV, respectively, by cyclic voltammetry. Using differential pulse voltammetry, the calibration curves for DA, AA and UA were obtained over the range of 0.1-200 μM, 0.15-1 mM and 10-130 μM, respectively. With good selectivity and sensitivity, the present method provides a simple method for selective detection of DA, AA and UA in biological samples.  相似文献   

10.
A carbon paste electrode (CPE) modified with thionine immobilized on multi-walled carbon nanotube (MWCNT), was prepared for simultaneous determination of ascorbic acid (AA) and acetaminophen (AC) in the presence of isoniazid (INZ). The electrochemical response characteristics of the modified electrode toward AA, AC and INZ were investigated by cyclic and differential pulse voltammetry (CV and DPV). The results showed an efficient catalytic role for the electro-oxidation of AA and AC, leading to a remarkable peak resolution (∼303 mV) for two compounds. On the other hand, the presence of INZ, which is considered as important drug interference for AC, does not affect the voltammetric responses of these pharmaceuticals. The mechanism of the modified electrode was analyzed by monitoring the CVs at various potential sweep rates and pHs of the buffer solutions. Under the optimum conditions, the calibration curves for AA, AC and INZ were obtained in the range of 1 × 10−6 to 1 × 10−4 M, 1 × 10−7 to 1 × 10−4 M and 1 × 10−6 to 1 × 10−4 M, respectively. The prepared modified electrode shows several advantages such as simple preparation method, high sensitivity, long-time stability, ease of preparation and regeneration of the electrode surface by simple polishing and excellent reproducibility. The proposed method was applied to determination of AA, AC and INZ in commercial drugs and in plasma samples and the obtained results were satisfactory.  相似文献   

11.
A new gold nanoparticles-modified electrode (GNP/LC/GCE) was fabricated by self-assembling gold nanoparticles to the surface of the l-cysteine-modified glassy carbon electrode. The modified electrode showed an excellent character for electrocatalytic oxidization of uric acid (UA) and ascorbic acid (AA) with a 0.306 V separation of both peaks, while the bare GC electrode only gave an overlapped and broad oxidation peak. The anodic currents of UA and AA on the modified electrode were 6- and 2.5-fold to that of the bare GCE, respectively. Using differential pulse voltammetry (DPV), a highly selective and simultaneous determination of UA and AA has been explored at the modified electrode. DPV peak currents of UA and AA increased linearly with their concentration at the range of 6.0 × 10−7 to 8.5 × 10−4 mol L−1 and 8.0 × 10−6 to 5.5 × 10−3 mol L−1, respectively. The proposed method was applied for the detection of UA and AA in human urine with satisfactory result.  相似文献   

12.
This paper reports the selective determination of norepinephrine (NEP) in the presence of very important interferences, ascorbic acid (AA) and uric acid (UA) using electropolymerized film of 2-amino-1,3,4-thiadiazole (p-ATD) modified glassy carbon (GC) electrode in 0.20 M phosphate buffer solution (pH 5.0). The bare GC electrode does not separate the voltammetric signals of AA, NEP and UA. However, p-ATD modified GC electrode not only resolved the voltammetric signals of AA, NEP and UA with potential differences of 150 and 130 mV between AA–NEP and NEP–UA, respectively but also dramatically enhanced the oxidation peak currents of them when compared to bare GC electrode. The modified electrode showed an excellent selectivity towards NEP even in the presence of 100-fold excess of AA and UA. The amperometric current was linearly increased from 40 nM to 25 μM for NEP and the lowest detection limit was found to be 0.17 nM (S/N = 3). The practical application of the modified electrode was demonstrated by determining NEP in norepinephrine hydrochloride injection.  相似文献   

13.
5-Hydroxytryptophan (5-HTP) was covalently grafted on the surface of glassy carbon electrodes (GCEs) using cyclic voltammetric method in a phosphate buffer solution. The prepared electrode, denoded as 5-HTP/GCE, was characterized by X-ray photoelectron spectroscopy, cyclic voltammetry and differential pulse voltammetry (DPV). Tryptophan grafted GCE (TRP/GCE) and 5-hydroxytryptamine grafted GCE (5-HTP/GCE) were also prepared by the same method for comparison. It was found that the electrocatalytic activities toward the oxidation of uric acid (UA) and ascorbic acid (AA) was in the order of 5-HT/GCE > 5-HTP/GCE > TRP/GCE for UA oxidation and 5-HT/GCE = 5-HTP/GCE > TRP/GCE for AA oxidation. However, the CV current sensitivity was estimated as 4:2:1 for 5-HTP/GCE:5-HT/GCE:TRP/GCE. The DPV peaks for UA and AA oxidation appeared at 0.07 V and 0.34 V versus SCE, respectively, allowing simultaneous determination in mixtures. A linearly response in the range of: 5.0 × 10−7 to 1.1 × 10−5 M with the detection limit (s/n = 3) of 2.8 × 10−7 M for UA determination, and a linear response in the range of: 5.0 × 10−6 to 1.0 × 10−4 M with the detection limit of 4.2 × 10−6 M for AA determination were obtained. This electrode was used for UA and AA determinations in human urine samples satisfactorily.  相似文献   

14.
The copper was deposited on glassy carbon (GC) and indium tin oxide (ITO) electrodes by electrochemical method. The copper structures on electrode were characterized by atomic force microscope, X-ray diffractometeric pattern and differential pulse voltammetric studies. Optimal conditions for uniform growth of copper structures on the electrode were established. Voltammetric sensor was fabricated using the copper deposited GC electrode for the simultaneous detection and determination of uric acid (UA) and homovanillic acid (HVA) in the presence of excess concentrations of ascorbic acid (AA). The voltammetric signals due to AA and UA oxidation were well separated with a potential difference of 400 mV and AA did not interfere with the measurement of UA and HVA at the GC/Cu electrode. Linear calibration curves were obtained in the concentration range 1-40 μM for AA and 20-50 μM for UA at physiological pH and a detection limit of 10 nM of UA in the presence of 10-fold excess concentrations of AA was achieved. The simultaneous detection of submicromolar concentrations of AA, UA and HVA was achieved at the GC/Cu electrode. The practical utility of the present GC/Cu modified electrode was demonstrated by measuring the AA content in Vitamin C tablet, UA content in human urine and blood serum samples with satisfactory results.  相似文献   

15.
Functionalized polypyrrole film were prepared by incorporation of (Fe(CN)6)4− as doping anion, during the electropolymerization of pyrrole onto a carbon paste electrode (CPE) in aqueous solution by using potentiostatic method. The electrochemical behavior of the (Fe(CN)6)3−/(Fe(CN)6)4− redox couple in polypyrrole was studied by cyclic voltammetry and double step potential chronoamperometry methods. In this study, an obvious surface redox reaction was observed and dependence of this reaction on the solution pH was illustrated. The electrocatalytic ability of polypyrrole/ferrocyanide films modified carbon paste electrode (Ppy/FCNMCPEs) was demonstrated by oxidation of ascorbic acid. It has been found that under optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such electrode occurs at a potential about 540 mV less positive than unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and catalytic reaction rate constant, kh′, were also determined by using various electrochemical approaches.The catalytic oxidation peak current showed a linear dependent on the ascorbic acid concentration and a linear calibration curve was obtained in the range of 4.5×10−4 to 9.62×10−3 M of ascorbic acid with a correlation coefficient of 0.9999. The detection limit (2σ) was determined as 5.82×10−5 M.  相似文献   

16.
A novel modified glassy carbon electrode (GCE) with a binuclear copper complex was fabricated using a cyclic voltammetric method in phosphate buffer solution. This modified electrode shows very efficient electrocatalytic activity for anodic oxidation of both dopamine (DA) and ascorbic acid (AA) via substantial decrease in anodic overpotentials for both compounds. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using this modified electrode show two well-resolved anodic waves for the oxidation of DA and AA in mixed solution, which makes it possible for simultaneous determination of both compounds. Linear analytical curves were obtained in the ranges 2.0–120.0 μM and 5.0–160.0 μM for DA and AA concentrations by using DPV methods, respectively. The detection limits were 1.4 × 10−6 M of DA and 2.8 × 10−6 M of AA. This electrode was used for AA and DA determinations in medicine and foodstuff samples with satisfactory results.  相似文献   

17.
A glassy carbon electrode modified with LaHCF was constructed and was characterized by cyclic voltammetry (CV) and electrochemical impedance spectrum (EIS). The resulting LaHCF modified glassy carbon electrode had a good catalytic character on uric acid (UA) and was used to detect uric acid and ascorbic acid (AA) simultaneously. This modified electrode exhibits potent and persistent electron-mediating behavior followed by well-separated oxidation peaks towards UA and AA with activation overpotential. For UA and AA in mixture, one can well separate from the other with a potential large enough to allow the determination of one in presence of the other. The DPV peak currents obtained increased linearly on the UA in the range of 2.0 × 10−7 to 1.0 × 10−4 mol/L with the detection limit (signal-to-noise ratio was 3) for UA 1.0 × 10−7 mol/L. The proposed method showed excellent selectivity and stability, and the determination of UA and AA simultaneously in urine was satisfactory.  相似文献   

18.
A silica gel-modified carbon paste electrode (Si-CPE) was fabricated and used for selective and sensitive determination of insulin. The experimental results suggested that insulin effectively accumulated on surface of the modified electrode resulting in a marked enhancement of its oxidation current response. Therefore, the modified electrode was used as an electrochemical sensor for the differential pulse adsorptive stripping voltammetric and hydrodynamic amperometric determination of insulin. The influence of various experimental parameters on the voltammetric response of insulin was investigated. Using hydrodynamic amperometry, under optimum conditions, calibration plot for insulin was linear in the range of 90–1400 pM. The sensitivity and detection limit of the proposed amperometric method were found to be 107.3 pA/pM (1511.3 pA/pM cm2) and 36 pM, respectively. The electrode has the remarkable advantages of simple preparation using inexpensive material, high reproducibility, good chemical and mechanical stabilities, and easy surface renewal owing to bulk modification. The high selectivity of the modified electrode towards oxidation of insulin in the presence of sulfur containing amino acids including cystine, cysteine, and glutathione is a key advantage of the proposed electrode.  相似文献   

19.
The layer-by-layer adsorption technique was used to prepare polyaniline (PANI)–gold nanoparticles (AuNP) multilayered structures with different AuNP/PANI ratios. By means of microgravimetric measurements it was found that the amount of the adsorbed species depends on the duration of the AuNP adsorption step. At fixed adsorption step durations the amount of both (PANI and AuNP) materials increases linearly with the number of adsorption steps.Two types of PANI–AuNP multilayered nanocomposites with different AuNP/PANI ratio were studied as electrocatalytic materials for dopamine and uric acid oxidation. The sensitivity of PANI–AuNP for dopamine oxidation was found to depend on type of the nanocomposite whereas for uric acid oxidation the sensitivity remained unaffected by the type of the nanocomposite structure. This result is discussed in terms of the different limitations for both oxidation reactions. By means of differential pulse voltammetry experiments linear concentration dependences of the anodic peak currents were observed for both dopamine and uric acid in the concentration ranges 7–148 μmol dm−3 and 29–720 μmol dm−3, respectively. In the presence of both analytes no interference effects were detected.  相似文献   

20.
Supercritical fluids, especially carbon dioxide, are increasingly used as carriers for adsorption-desorption processes, particularly in the pharmaceutical industry. Nevertheless, equilibria data for such processes are rather limited. Therefore, in this work, the adsorption equilibria of benzoic acid onto non-modified silica gel from scCO2 were evaluated by Supercritical Fluid Chromatography applying the Peak Maxima method. Solubility of benzoic acid in scCO2 was enhanced by addition of 2-propanol.The effects of modifier content, temperature and pressure on the solute loading were investigated. Experimental data were best described by the cubic Hill isotherm model, which accounted for the change of curvature of the elution profiles observed as concentrations in the mobile phase increased. For the concentration range reached in this study (up to 6 mg/mL), adsorption of benzoic acid was favoured at low modifier contents, high temperatures and low pressures, conditions at which the solvating power of the modified scCO2 decreased.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号