首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
This paper proposes a system modeling and performance analysis of a renewable hydrogen energy hub (RHEH) connected to an ac/dc hybrid microgrid (MG). The proposed RHEH comprises a photovoltaic (PV)-based renewable energy source (RES) as the primary source, a proton exchange membrane fuel cell (PEMFC) as the secondary power source, and a proton exchange membrane electrolyzer (PEMELZ) that can generate and store hydrogen in a hydrogen tank. All these resources are directly connected at the dc bus of the ac/dc microgrids. The PEMFC operates and utilizes the hydrogen from the hydrogen tank when the energy generated by RES cannot meet the load demand. A coordinated power flow control approach has been developed for the RHEH to mitigate the mismatch between generation and demand in the ac/dc microgrid and produce renewable hydrogen when renewable power is in excess. The paper also proposes a modified hybrid Perturb & Observe-Particle Swarm Optimization (Hybrid PO-PSO) algorithm to ensure the maximum power point tracking (MPPT) operation of the PV and the PEMFC. The operation of the proposed RHEH is validated through simulations under various critical conditions. The results show that the proposed RHEH is effective to maintain the system power balance and can provide power-to-hydrogen and hydrogen-to-power when required.  相似文献   

2.
In this paper, a novel control strategy for frequency control in stand-alone application based on coordination control of fuel cells (FCs) and double-layer capacitor (DLC) bank in an autonomous hybrid renewable energy power generation system is implemented. The proposed renewable energy power generation subsystems include wind turbine generator (WTG), photovoltaic system (PV), FC system and DLC bank as energy storage system. The system performance under different condition has been verified by using real weather data. Simulation results demonstrate the validity of proposed studied hybrid power generation system feeding isolated loads in power frequency balance condition.  相似文献   

3.
针对光伏并网系统中光伏微电源出力的波动性和间歇性,将蓄电池和超级电容器构成的混合储能系统HESS(hybrid energy storage system)应用到光伏并网系统中可以实现光伏功率平滑、能量平衡以及提高并网电能质量。在同时考虑蓄电池的功率上限和超级电容的荷电状态(SOC)的情况下,对混合储能系统提出了基于超级电容SOC的功率分配策略;该策略以超级电容的SOC和功率分配单元的输出功率作为参考值,对混合储能系统充放电过程进行设计。超级电容和蓄电池以Bi-direction DC/DC变换器与500 V直流母线连接,其中超级电容通过双闭环控制策略对直流母线电压进行控制。仿真结果表明,所提功率分配策略能对混合储能系统功率合理分配,而且实现了单位功率因数并网,稳定了直流母线电压。  相似文献   

4.
由于国内的储能技术起步较晚,分布式电源中应用单一储能介质很难满足系统运行要求.基于某公司的光伏储能并网系统示范项目,以具有快速响应特性的超级电容器和具有大容量储能特性的锂离子电池为混合储能系统,以储能控制器为控制核心统一协调控制,使电能以可控功率按需送入电网.该系统可有效提高储能系统的功率输出能力,优化储能系统的充放电过程,延长储能电池的使用寿命,具有良好的应用及推广价值.  相似文献   

5.
A technico-economic analysis based on integrated modeling, simulation, and optimization approach is used in this study to design an off grid hybrid solar PV/Fuel Cell power system. The main objective is to optimize the design and develop dispatch control strategies of the standalone hybrid renewable power system to meet the desired electric load of a residential community located in a desert region. The effects of temperature and dust accumulation on the solar PV panels on the design and performance of the hybrid power system in a desert region is investigated. The goal of the proposed off-grid hybrid renewable energy system is to increase the penetration of renewable energy in the energy mix, reduce the greenhouse gas emissions from fossil fuel combustion, and lower the cost of energy from the power systems. Simulation, modeling, optimization and dispatch control strategies were used in this study to determine the performance and the cost of the proposed hybrid renewable power system. The simulation results show that the distributed power generation using solar PV and Fuel Cell energy systems integrated with an electrolyzer for hydrogen production and using cycle charging dispatch control strategy (the fuel cell will operate to meet the AC primary load and the surplus of electrical power is used to run the electrolyzer) offers the best performance. The hybrid power system was designed to meet the energy demand of 4500 kWh/day of the residential community (150 houses). The total power production from the distributed hybrid energy system was 52% from the solar PV, and 48% from the fuel cell. From the total electricity generated from the photovoltaic hydrogen fuel cell hybrid system, 80.70% is used to meet all the AC load of the residential community with negligible unmet AC primary load (0.08%), 14.08% is the input DC power for the electrolyzer for hydrogen production, 3.30% are the losses in the DC/AC inverter, and 1.84% is the excess power (dumped energy). The proposed off-grid hybrid renewable power system has 40.2% renewable fraction, is economically viable with a levelized cost of energy of 145 $/MWh and is environmentally friendly (zero carbon dioxide emissions during the electricity generation from the solar PV and Fuel Cell hybrid power system).  相似文献   

6.
Due to the characteristics of intermittent photovoltaic power generation and power fluctuations in distributed photovoltaic power generation, photovoltaic grid-connected systems are usually equipped with energy storage units. Most of the structures combined with energy storage are used as the DC side. At the same time, virtual synchronous generators have been widely used in distributed power generation due to their inertial damping and frequency and voltage regulation. For the PV-storage grid-connected system based on virtual synchronous generators, the existing control strategy has unclear function allocation, fluctuations in photovoltaic inverter output power, and high requirements for coordinated control of PV arrays, energy storage units, and photovoltaic inverters, which make the control strategy more complicated. In order to solve the above problems, a control strategy for PV-storage grid-connected system based on a virtual synchronous generator is proposed. In this strategy, the energy storage unit implements maximum power point tracking, and the photovoltaic inverter implements a virtual synchronous generator algorithm, so that the functions implemented by each part of the system are clear, which reduces the requirements for coordinated control. At the same time, the smooth power command is used to suppress the fluctuation of the output power of the photovoltaic inverter. The simulation validates the effectiveness of the proposed method from three aspects: grid-connected operating conditions, frequency-modulated operating conditions, and illumination sudden-drop operating condition. Compared with the existing control strategies, the proposed method simplifies the control strategies and stabilizes the photovoltaic inverter fluctuation in the output power of the inverter.  相似文献   

7.
It is necessary to have an energy management system based on one or more control strategies to sense, monitor, and control the behavior of the hybrid energy sources. In renewable hybrid power systems containing fuel cells and batteries, the hydrogen consumption reduction and battery state of charge (SOC) utilizing are the main objectives. These parameters are essential to get the maximum befits of cost reduction as well as battery and hydrogen storage lifetime increasing. In this paper, a novel hybrid energy management system (HEMS) was designed to achieve these objectives. A renewable hybrid power system combines: PV, PEMFC, SC, and Battery was designed to supply a predetermined load with its needed power. This (REHPS) depends on the PV power as a master source during the daylight. It uses the FC to support as a secondary source in the night or shading time. The battery is helping the FC when the load power is high. The supercapacitor (SC) is working at the load transient or load fast change. The proposed energy management system uses fuzzy logic and frequency decoupling and state machine control strategies working together as a hybrid strategy where the switching over between both strategies done automatically based on predetermined values to obtain the minimum value of hydrogen consumption and the maximum value of SOC at the same time. The proposed HEMS achieves 19.6% Hydrogen consumption saving and 5.4% increase in SOC value compared to the results of the same two strategies when working as a stand-alone. The load is designed to show a surplus power when the PV power is at its maximum value. This surplus power is used to charge the battery. To validate the system, the results were compared with the results of each strategy if working separately. The comparison confirms the achievement of the hybrid energy management system goal.  相似文献   

8.
Hybrid renewable energy systems are expected to become competitive to conventional power generation systems in the near future and, thus, optimization of their operation is of particular interest. In this work, a hybrid power generation system is studied consisting of the following main components: photovoltaic array (PV), electrolyser, metal hydride tanks, and proton exchange membrane fuel cells (PEMFC). The key advantage of the hybrid system compared to stand-alone photovoltaic systems is that it can store efficiently solar energy by transforming it to hydrogen, which is the fuel supplied to the fuel cell. However, decision making regarding the operation of this system is a rather complicated task. A complete framework is proposed for managing such systems that is based on a rolling time horizon philosophy.  相似文献   

9.
The integration of significant amounts of renewable-storage hybrid power generation systems to the electric grid poses a unique set of challenges to utilities and system operators. This article deals with the designing methodology of an intelligent control based grid-connected a hybrid system composed of renewable energy source (RES) and storage system (SS). RES is a photovoltaic (PV) source and SS is a process of hydrogen transformation system (H2TS) which composed of alkaline water electrolysis (AWE) for decomposition water by using the PV power, a tank used for gas storage and a proton exchange membrane (PEM) fuel cell (FC) to transform the H2 to the electrical energy. The interconnection of the grid with the power generation system (PGS) is ensured through using a DC/AC hysteresis converter and it can synchronize current with the grid voltage among an independent control of active (P) and reactive (Q) power through a possibility of the Q compensation. In the proposed system, three algorithms are applied; two used inside generation and the third is used inside the grid. Perturb and observe (P&O) maximum power point tracking (MPPT) control algorithm always finds optimal power in the PV generator. A simple cascade controls loop of DC-DC boost converter and operate the FC generator to ensure maximum power and to regulate the DC Bus voltage. In addition, adaptive fuzzy logic control (FLC) unit is developed to control the DC/AC inverter, with adopting an off-line optimization based on genetic algorithms (GAs) applauded for tune different issues as scaling factors of the FLC and PIDs gains of the PV and the H2TS control loops. Simulated results prove a big success of the proposed controls of the grid connected the hybrid PV-H2TS with good performance.  相似文献   

10.
In this study, design and optimization of the hybrid renewable energy system consisting of Photovoltaic (PV)/Electrolyzer/Proton Exchange Membrane Fuel Cell (PEMFC) was investigated to provide electricity and heat for Greenhouse in ?anl?urfa (Turkey). The coupling of a photovoltaic system with PEMFC was preferred to supply continuous production of electric energy throughout the year. Additionally, produced heat from PEMFC was used to heating of the greenhouse by micro cogeneration application. The MATLAB/Simulink was applied to the design and optimization of the proposed hybrid system. In the designed system, solar energy was selected to produce the Hydrogen (H2) required to run the electrolyzer. In cases where the solar energy is not sufficient and cannot meet the electricity requirement for the electrolyzer; the H2 requirement for the operation of the PEMFC was met from the H2 storage tanks and energy continuity was ensured. The electrolyzer was designed for H2 demand of the 3 kW PEMFC which were met the greenhouse energy requirement. PEMFC based hybrid system has 48% electrical and 45% thermal efficiencies. According to optimization results obtained for the proposed hybrid system, the levelized cost of energy was found 0.117 $/kWh. The obtained results show the proposed PV/Electrolyzer/PEMFC hybrid power system provides an applicable option for powering stand-alone application in a self-sustainable expedient.  相似文献   

11.
针对并网光伏发电系统输出功率的波动,提出利用混合储能系统对功率进行平抑.介绍了光伏最大功率跟踪和并网逆变的控制,为实现发电和并网功率的匹配,考虑蓄电池和超级电容器各自特性的优势,对混合储能系统提出了三级式功率分配策略;通过设计相应的控制方法和以功率分配单元的输出功率作为参考值,混合储能系统控制变换器进行合理充放电.混合储能系统不仅保证了并网功率按计划运行,而且稳定了直流母线电压、满足了随机负荷供电.通过仿真验证,三级式功率分配策略有效,控制方法可行.  相似文献   

12.
This paper presents the results of investigations on the application of wind, photovoltaic (PV), and hybrid wind/PV power generating systems for utilization as stand-alone systems. A simple numerical algorithm has been developed for generation unit sizing. It has been used to determine the optimum generation capacity and storage needed for a stand-alone, wind, PV, and hybrid wind/PV system for an experimental site in a remote area in Montana with a typical residential load. Generation and storage units for each system are properly sized in order to meet the annual load and minimize the total annual cost to the customer. In addition, an economic analysis has been performed for the above three scenarios and is used to justify the use of renewable energy versus constructing a line extension from the nearest existing power line to supply the load with conventional power. Annual average hourly values for load, wind speed, and insolation have been used  相似文献   

13.
This study presents an original control algorithm for a hybrid energy system with a renewable energy source, namely, a polymer electrolyte membrane fuel cell (PEMFC) and a photovoltaic (PV) array. A single storage device, i.e., a supercapacitor (ultracapacitor) module, is in the proposed structure. The main weak point of fuel cells (FCs) is slow dynamics because the power slope is limited to prevent fuel starvation problems, improve performance and increase lifetime. The very fast power response and high specific power of a supercapacitor complements the slower power output of the main source to produce the compatibility and performance characteristics needed in a load. The energy in the system is balanced by d.c.-bus energy regulation (or indirect voltage regulation). A supercapacitor module functions by supplying energy to regulate the d.c.-bus energy. The fuel cell, as a slow dynamic source in this system, supplies energy to the supercapacitor module in order to keep it charged. The photovoltaic array assists the fuel cell during daytime. To verify the proposed principle, a hardware system is realized with analog circuits for the fuel cell, solar cell and supercapacitor current control loops, and with numerical calculation (dSPACE) for the energy control loops. Experimental results with small-scale devices, namely, a PEMFC (1200 W, 46 A) manufactured by the Ballard Power System Company, a photovoltaic array (800 W, 31 A) manufactured by the Ekarat Solar Company and a supercapacitor module (100 F, 32 V) manufactured by the Maxwell Technologies Company, illustrate the excellent energy-management scheme during load cycles.  相似文献   

14.
光伏发电的间歇性和随机性是制约其大规模发展的主要因素,由此文章提出一种适用于多场景的光伏-双单元储能系统协同平抑功率波动控制策略。首先,针对光伏电站多个典型出力场景,并结合并网限制要求,对光伏原始功率信号进行变分模态分解,求得并网目标功率和储能需求功率,并利用阈值补偿方法缩短计算时长;然后,通过协调互补的双单元储能系统对储能需求功率进行消纳,使得各储能单元能够在标准充、放循环深度内独立承担任务;最后,在Matlab平台上对所提信号分析算法的平抑效果,以及光伏-双单元储能系统协同平抑功率波动控制策略的普适性进行仿真验证。仿真结果表明,在多个典型场景下,所测得的并网目标功率均满足并网限制要求,所选的分析算法可有效平抑光伏出力的波动,该协同控制策略能够保证双单元储能系统的长期稳定运行,大幅度提高了光伏并网的可靠性。  相似文献   

15.
In this study, a multi-source hybrid power system consisting of wind turbine (WT), photovoltaic (PV) solar unit, proton exchange membrane (PEM) FC and battery is proposed. The WT and PV generation systems are considered as the main power sources for utilizing the available renewable energy. The FC system is proposed as the back-up generation combined with electrolyzer unit and battery picks up the fast load transients and ripples. In such a hybrid system, energy management plays an important role for the overall system performance and durability. From this perspective, a fuzzy logic based intelligent controller is considered in this study. Besides, a detailed minute-scale meteorological and load demand data is utilized in the simulation process and the importance of utilization of such detailed data is presented. This detailed analysis may be valuable for evaluating the feasibility of grid-independent hybrid renewable energy units for upcoming power systems.  相似文献   

16.
This paper presents a novel hourly energy management system (EMS) for a stand-alone hybrid renewable energy system (HRES). The HRES is composed of a wind turbine (WT) and photovoltaic (PV) solar panels as primary energy sources, and two energy storage systems (ESS), which are a hydrogen subsystem and a battery. The WT and PV panels are made to work at maximum power point, whereas the battery and the hydrogen subsystem, which is composed of fuel cell (FC), electrolyzer and hydrogen storage tank, act as support and storage system. The EMS uses a fuzzy logic control to satisfy the energy demanded by the load and maintain the state-of-charge (SOC) of the battery and the hydrogen tank level between certain target margins, while trying to optimize the utilization cost and lifetime of the ESS. Commercial available components and an expected life of the HRES of 25 years were considered in this study. Simulation results show that the proposed control meets the objectives established for the EMS of the HRES, and achieves a total cost saving of 13% over other simpler EMS based on control states presented in this paper.  相似文献   

17.
In this paper, the robust capability of HOMER and Criteria-COPRAS is deployed to explore the prospect of selecting a renewable energy system. The energy system consisting of wind turbines, solar photovoltaic (PV), fuel cell (FC), electrolyzer, hydrogen storage, and battery energy storage is intended to power a residential load in Lagos Nigeria. Based on the economic metric, the results show that the optimal system is a PV-Battery whose total net present cost (TNPC) and initial investment cost are $9060 and $3,818, respectively. However, if the energy systems are ranked based on multiple criteria (economic, technical and environmental aspects), the most preferred of the feasible energy systems is a hybrid PV-FC-wind-battery (TNPC-$10,324, initial cost: $7670). The study results indicate that, for viability in the adoption of hydrogen energy storage as part of the hybrid energy system, the selection metric should be based on more than one criterion.  相似文献   

18.
Bangladesh is a potential site of implementing renewable energy system to reduce the severe power crisis throughout the year. According to this, Chittagong is the southeastern part of Bangladesh is also a potential site for implementing renewable energy system such as grid-connected photovoltaic (PV) system. Financial viability and green-house gas emission reduction of solar PV as an electricity generation source are assessed for 500 kW grid connected solar PV system at University of Chittagong, Chittagong. Homer simulation software and monthly average solar radiation data from NASA is used for this task. In the proposed system monthly electricity generation varies between 82.65 MW h and 60.3 MW h throughout the year with a mean value of 68.25 MW h depending on the monthly highest and lowest solar radiation data. It is found that per unit electricity production cost is US$ 0.20 based on project lifetime 25 years. The IRR, equity payback and benefit-cost ratio shows favorable condition for development of the proposed solar PV system in this site. A minimum 664 tones of green-house gas emissions can be reduced annually utilizing the proposed system.  相似文献   

19.
分析了风光互补发电系统的技术优势,设计了基于固态变压器结构的并网型风光互补发电系统。分别建立了光伏系统,风力发电系统,超级电容和蓄电池的模型,并分析各环节的控制策略,提出了基于平均功率的储能设备容量配置方法。仿真结果表明,该系统能模拟风光互补系统在不同模式下的运行特性,可以有效降低功率波动和维持电压稳定,并能在低光照强度、低风速等情况下为系统提供短时能量支撑。  相似文献   

20.
This study proposes a combined hydrogen, heating and power system based on solar energy for the off-grid application of distributed renewable energy. With hydrogen as the energy carrier, the stable consumption of renewable energy can be achieved by integrating alkaline water electrolysis (AWE), metal hydride (MH) hydrogen storage, and proton exchange membrane fuel cells (PEMFCs). An energy management strategy is proposed based on the coordinated control of mass, energy, and information flow. Fluctuations in multi-source heat flow during solar photovoltaic (PV) power generation, hydrogen production, hydrogen-storage, and PEMFC power generation were studied based on electric and heating loads of typical winter and summer days in an eco-neighborhood in Ningbo, China. Owing to differences in solar radiation between summer and winter, the total electric energy generated by PV panels was 6179 kWh and 3667 kWh for summer and winter, respectively. The start-up times for AWE and MHs were 0.92 h and 0.32 h in summer and 1.70 h and 0.55 h in winter, respectively. After one day of operation, the hydrogen and heat surpluses were 57.17 kg and 5735.83 MJ in summer, while in winter the hydrogen surplus and heat deficit were 30.87 kg and 226.41 MJ, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号