首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 265 毫秒
1.
目的研究ABO血型不合供者外周血造血干细胞的采集方法,探讨不去除红细胞和/或血浆进行造血干细胞移植的安全性。方法 29例异基因外周血干细胞移植供者与受者HLA配型为全相合或1~3位点不合,其中ABO主要不合13例,次要不合7例,ABO血型相合9例。采用CS-3000Plus血细胞分离机的干细胞采集程序对ABO血型不合供者的外周血造血干细胞进行采集,不去除红细胞和/或血浆,直接回输给受者。结果 ABO血型主要不合、次要不合及血型相合的供者每次采集的外周血干细胞(PBSC)产品终体积为(59.11±1.19)ml,单个核细胞(MNC)采集物、MNC比例、CD34+细胞、RBC含量三组间的差异无统计学意义。结论应用CS-3000Plus血细胞分离机采集ABO血型不合供者外周血造血干细胞,不仅对供者安全,而且采集产品中造血干细胞浓度较高,血型不合的红细胞污染较少,不需要去除红细胞和血浆,可安全地用于ABO血型不合的受者。  相似文献   

2.
ABO血型不合供者外周血造血干细胞的采集及移植效果研究   总被引:1,自引:0,他引:1  
目的探讨应用CS-3000 Plus血细胞分离机采集ABO血型不合供者外周血造血干细胞的效率及不去除红细胞和/或血浆进行异基因外周血造血干细胞移植(PBSCT)的安全性。方法经G-CSF 5μg/(kg.d)动员的异基因外周血干细胞供者33名,应用CS-3000 Plus血细胞分离机的干细胞采集程序于动员后d 5采集,其中ABO血型主要不合12名,次要不合8名以及ABO血型相合13名。根据供者外周血的红细胞压积(Hct)和单个核细胞(MNC)计数,对分离机参数作相应调整。输注前从产品袋中留取干细胞,检测有核细胞数、MNC比例、CD34+细胞数、红细胞、血浆含量。单次处理循环血量(9 986±2 489)ml,抗凝剂用量(971±162)ml。供者采集前注射10%葡萄糖酸钙,以预防低钙反应。观察PBSC输注后受者的生命体征、尿液颜色及是否有溶血相关不良反应等。结果ABO血型主要不合组、次要不合组与ABO血型相合组采集物中的有核细胞数、CD34+细胞数、MNC比例无统计学差异(P>0.05),3组供者每次采集的PBSC产品终体积近60 ml,ABO主要不合组采集物中混入红细胞为(3.67—10.25)×1010/袋,ABO次要不合组采集物中血浆量为22—38 ml,不去除红细胞及血浆,直接回输给受者,均未出现溶血反应,所有患者造血功能均获得重建。结论应用CS-3000 Plus血细胞分离机采集ABO血型不合供者的外周血干细胞,通过调整分离机参数,减少ABO血型不合红细胞的混入,可以获得足够的干细胞数量并安全用于移植。  相似文献   

3.
背景:异基因外周血造血干细胞移植大约1/3是在ABO血型不合的供受者之间进行的.目的:探讨ABO血型主要不合供者外周血造血干细胞在不去除红细胞情况下应用COM.TEC血细胞分离机直接回输给受者的可行性.方法:27例HLA全相合同胞供者皮下注射粒细胞集落刺激因子5 μg/(kg?d),连续5 d干细胞动员,于第5天开始应用COM.TEC血细胞分离机进行外周血造血干细胞单采,每次总处理血量为3.0~3.5个供者全身血量.ABO相合供者按常规方法进行单采,主要不合供者采取动态调整白膜收集量和保持稳定充足的血流量以减少红细胞污染.结果与结论:27例供者中ABO主要不合供者11例,相合供者16例.主要不合组产品体积及红细胞内含量均显著低于相合组(P < 0.05),回输给受者均未出现急性溶血反应;2组单个核细胞及CD34+细胞计数差异无显著性意义(P > 0.05),受者均获造血重建,中性粒细胞及血小板重建时间相似(P > 0.05).提示应用COM.TEC血细胞分离机进行ABO主要不合供者外周血造血干细胞单采,可以保持稳定充足的血流量情况下通过动态调整白膜收集量参数,在不影响采集产品产量和质量的同时显著减少红细胞的污染,预防回输后受者的急性溶血反应.  相似文献   

4.
背景:异基因外周血造血干细胞移植大约1/3是在ABO血型不合的供受者之间进行的。目的:探讨ABO血型主要不合供者外周血造血干细胞在不去除红细胞情况下应用COM.TEC血细胞分离机直接回输给受者的可行性。方法:27例HLA全相合同胞供者皮下注射粒细胞集落刺激因子5μg/(kg.d),连续5d干细胞动员,于第5天开始应用COM.TEC血细胞分离机进行外周血造血干细胞单采,每次总处理血量为3.0~3.5个供者全身血量。ABO相合供者按常规方法进行单采,主要不合供者采取动态调整白膜收集量和保持稳定充足的血流量以减少红细胞污染。结果与结论:27例供者中ABO主要不合供者11例,相合供者16例。主要不合组产品体积及红细胞内含量均显著低于相合组(P〈0.05),回输给受者均未出现急性溶血反应;2组单个核细胞及CD34+细胞计数差异无显著性意义(P〉0.05),受者均获造血重建,中性粒细胞及血小板重建时间相似(P〉0.05)。提示应用COM.TEC血细胞分离机进行ABO主要不合供者外周血造血干细胞单采,可以保持稳定充足的血流量情况下通过动态调整白膜收集量参数,在不影响采集产品产量和质量的同时显著减少红细胞的污染,预防回输后受者的急性溶血反应。  相似文献   

5.
目的:观察COBE Spectra血细胞分离机AutoPBSC程序以及Spectra Optia血细胞分离机MNC程序对采集的健康供者外周血造血干细胞成分的影响。方法:2015年1月至2016年8月期间对12例供者随机应用COBE Spectra血细胞分离机AutoPBSC程序以及Spectra Optia血细胞分离机MNC程序进行外周血造血干细胞采集,观察应用不同采集程序获得的采集物中单个核细胞、CD34~+细胞、粒细胞、淋巴细胞、血小板数的差异。结果:两种采集程序在循环血量、采集时间及抗凝剂使用量方面无显著差异。COBE Spectra血细胞分离机AutoPBSC程序采集的采集物体积及单个核细胞计数均低于Spectra Optia血细胞分离机MNC程序的采集物体积及单个核细胞计数。AutoPBSC程序采集的CD34~+细胞计数高于MNC程序采集的CD34~+细胞计数。AutoPBSC程序采集物中混入的淋巴细胞及血小板较MNC程序中多,其差异均有统计学意义(P0.05)。结论:与Spectra Optia血细胞分离机MNC程序相比,COBE Spectra血细胞分离机AutoPBSC程序采集的造血干细胞数量多,混入的淋巴细胞及血小板多。  相似文献   

6.
[目的]探讨应用CS-3000 Plus血细胞分离机采集ABO及Rh血型不合的供者外周血干细胞(PBSC)的得率及不去除红细胞或血浆用于异基因外周血干细胞移植的可行性.[方法]采用CS-3000 Plus血细胞分离机的自动干细胞采集程序对14例异基因外周血干细胞供者进行采集,其中ABO血型主要不合5例,次要不合6例,主要次要均不合2例,Rh血型主要不合1例.供者循环收集的细胞成分按供者外周血的红细胞比容(HCT)和单个核细胞(MNC)计数作相应调整.输注前从产品袋中留取标本检查有核细胞计数、MNC比例、CD34 细胞计数和台盼蓝拒染率.回输时对受者采取使用糖皮质激素、水化、碱化、利尿等保护措施.[结果]供者均经2~3次采集收集到足够的有核细胞直接回输给受者.共采集PBSC 30次,平均每次获得有核细胞5.65×1010,单个核细胞占96%~98%.CD34 细胞数平均为6.52×106/kg,细胞拒染率均为100%.ABO血型主要不合、主要、次要均不合及Rh主要血型不合的供者每次采集的PBSC产品终体积均为50 ml,产品中含压积红细胞3~7 ml,ABO血型次要不合供者每次采集的PBSC产品中含血浆15~25 ml,不去除红细胞及血浆,直接回输给受者,无一例出现溶血性输血反应,造血均获得重建.[结论]采用CS-3000Plus血细胞分离机,通过调整参数采集血型不合供者的外周血干细胞,减少血型不合的红细胞,可以获得足够的干细胞数量并安全用于移植.  相似文献   

7.
本研究探讨ABO血型不合异基因造血干细胞移植对红系造血的影响。对16例ABO血型不合的造血干移植患者的ABO血型,IgM和IgG抗体进行监测。结果显示,16例ABO血型不合的造血干细胞移植患者均恢复造血功能,与ABO血型相合组比较,ABO血型不合组在粒细胞植活时间、血小板植活时间无差异,但红系重建时间明显延长;ABO主侧不合与双侧不合受者抗供者凝集素消失时间与红系恢复时间有相关性。结论 :ABO血型不合的异基因造血干细胞移植会导致红系造血迟缓。移植前用供型血浆置换法或输注供者红细胞来中和受者体内抗供者红细胞的凝集素能缩短红细胞植入时间,减少红细胞的输注。  相似文献   

8.
目的:观察COBE Spectra血细胞分离机Auto PBSC程序、MNC程序及Spectra Optia血细胞分离机MNC程序采集自体外周血造血干细胞的效果及不良反应。方法:对41例采集对象分别采用COBE Spectra血细胞分离机Auto PBSC程序、MNC程序及Spectra Optia血细胞分离机MNC程序进行自体外周血造血干细胞采集,观察3种采集程序采集的MNC及CD34~+细胞数、采集后患者血红蛋白及血小板下降的差异以及3种采集程序采集过程中的不良反应。结果:在全血处理量及采集时间基本相同的情况下,COBE Spectra和Spectra Optia的MNC程序采集的MNC数较COBE Spectra Auto PBSC程序采集的数高,但采集的CD34~+细胞数均低于Auto PBSC程序采集的CD34~+细胞数(P0.05)。COBE Spectra和Spectra Optia的MNC程序采集的终产物体积大于Auto PBSC程序采集的终产物体积。Spectra Optia血细胞分离机MNC程序与COBE Spectra血细胞分离机MNC程序相比,采集的M NC数无显著差异,但Spectra Optia血细胞分离机M NC程序采集的CD34~+细胞数大于COBE Spectra血细胞分离机MNC程序采集的CD34~+细胞数(P0.05)。Spectra Optia的MNC程序采集后患者血小板及血红蛋白较采集前下降幅度最低(P0.05)。3种程序采集过程中的不良反应相似,患者均可耐受。结论:COBE Spectra血细胞分离机Auto PBSC程序和Spectra Optia血细胞分离机MNC程序采集自体外周血造血干细胞优于COBE Spectra血细胞分离机的MNC程序。Spectra Optia的MNC程序采集后患者血小板及血红蛋白损失最低。  相似文献   

9.
应用血细胞分离机采集ABO血型不合供者的外周血干细胞   总被引:2,自引:0,他引:2  
为了探索应用血细胞分离机采集ABO血型主要和(或)次要不合的供者外周血造血干细胞的得率及不去除红细胞或血浆用于干细胞移植的可行性,采用CobeSpectra(Version6.1)血细胞分离机的自动干细胞采集程序对9例异基因外周血造血干细胞供者进行采集,其中ABO血型主要不合4例,次要不合2例,主要次要均不合3例。对ABO血型主要不合及主要、次要均不合的供者每循环收集的细胞成分和血浆的量分别作相应调整。输注前从产品袋中留取标本检查有核细胞计数、单个核细胞比例、CD34 细胞计数和细胞的成活率(台盼蓝拒染率)。输入时对受者采取一系列保护肾功能的措施。液体总量控制在4000毫升/日。结果显示:除1例因供者体重远大于受者经1次采集即可满足移植所需细胞量外,其余供者均经2次采集收集到足够的有核细胞直接回输给受者或冰冻保存备用。共采集PBSC17次,平均每次获得有核细胞3.77×1010个,单个核细胞占97%-99%。CD34 细胞数平均为8.62×106/kg,细胞拒染率均为100%。ABO血型主要不合及主要、次要均不合的供者每次采集的PBSC产品中含压积红细胞8-10ml,ABO血型次要不合供者每次采集的PBSC产品中含血浆80-120ml,不去除红细胞及血浆,直接回输给受者。无1例出现溶血性输血反应,造血功能均获得重建。结论:采用CobeSpectra血细  相似文献   

10.
背景:ABO血型不合供受者之间进行外周血造血干细胞移植,面临受者血型的转变、移植后输血的选择等问题.目的:观察ABO血型不合外周血造血干细胞移植治疗血液病的临床疗效和近远期并发症.方法:回顾性分析了2005/2008武警总医院收治的10例ABO血型不合异基因外周血同胞供者造血干细胞移植患者的资料.总结植入效果,血型转变,移植物抗宿主病以及不良反应.结果与结论:9例患者恢复造血功能,血型转变为完全供者型,1例患者白细胞血小板恢复,但红细胞植入延迟.所有患者在输注移植物时未出现短暂的血红蛋白尿,无严重急性溶血和迟发型溶血的发生,1例出现严重的移植物抗宿主病.可见ABO血型不合外周血造血干细胞移植对移植疗效无明显影响,红细胞植入延迟的预防和处理十分重要.  相似文献   

11.
BACKGROUND: Granulocyte–colony‐stimulating factor–mobilized peripheral blood stem cells, collected by white blood cell apheresis, are used for more than 80% of allogeneic and most autologous hematopoietic stem cell transplantations. Optimal donor and recipient outcomes require maximized stem cell collection efficiency and minimized non–target cell contamination. Therefore, improved apheresis technology is desirable. The safety and feasibility of apheresis collections with the novel, electronics‐assisted apheresis system Spectra Optia v.5.0 (CaridianBCT) were recently demonstrated. An unpublished optimization trial had furthermore determined that different settings than manufacturer‐installed default might result in improved apheresis yields. STUDY DESIGN AND METHODS: The first prospective comparison of allogeneic peripheral blood stem cell apheresis with the Spectra Optia versus the COBE Spectra (CaridianBCT) mononuclear cell (MNC) in a routine clinical setting is reported here; “optimized” machine settings were used. Assessed variables included collection efficiency, product characteristics, donor outcomes, and frequency of operator interventions. Outcomes were additionally compared with historical data from the Spectra Optia in default mode. RESULTS: The mean CD34+ cell collection efficiency CE1 was 7.9% greater with the Spectra Optia than with the COBE Spectra MNC. Variability of outcomes was equally great. Reduced platelet (PLT) attrition necessitated 90% fewer autologous PLT reinfusions. Spectra Optia products contained 50% fewer red blood cells, but 50% more granulocytic lineage cells. Less operator input was required, although 26% of Spectra Optia apheresis procedures required triggering of the first chamber flush. Apheresis yield and collection efficiency were also markedly greater than in default‐mode Spectra Optia collections. CONCLUSION: Using optimized machine settings, peripheral blood stem cell apheresis outcomes with the automated apheresis system Spectra Optia exceed results with the COBE Spectra MNC or the Spectra Optia in the default mode.  相似文献   

12.
目的总结COBE SPECTRA血细胞分离机在恶性淋巴瘤自体外周血干细胞采集中的情况。方法总结17例48次采用COBE SPECTRA血细胞分离机进行恶性淋巴瘤自体外周血干细胞采集过程,分析血液学参数、不良反应等情况。结果17例共采集48次。其中7例采集2次;6例采集3次;4例采集4次;每次循环血量为74.03~205.56ml/kg,平均139.96 ml/kg;每次采集时间116~241 min,平均191.96 min;采集过程顺利,每例采集的单个核细胞(MNC)均〉3.0×108/kg,CD34+细胞均〉2×106/kg,全部病例均获造血功能重建,无移植相关死亡。48次采集过程中及结束后出现不良反应8次,男性7次,女性1次,为低血容量反应、枸橼酸盐毒性反应及血小板减少引起的症状;快速回输复苏后的造血干细胞,未见严重不良反应。结论采用COBE SPECTRA血细胞分离机进行自体外周血干细胞采集方法可靠,平均2.82次采集可达到临床治疗要求。  相似文献   

13.
本研究比较CEP+G-CSF与CVP+G-CSF动员方案对非霍奇金淋巴瘤(NHL)患者外周血造血干细胞动员采集及造血恢复的效果。回顾性分析我科收治的57例NHL患者。分组采用CEP+G-CSF与CVP+G-CSF动员方案进行外周血干细胞动员采集,并于预处理结束后回输外周血干细胞,分析动员效果、不良反应及自身移植后造血恢复情况。结果表明:动员期间所有患者外周血白细胞(WBC)计数均降至1.0×109/L以下,血小板(Plt)数降至40×109/L以下。57例患者均采集成功,CEP+G-CSF动员方案组采集单个核细胞(MNC)数和CD34+细胞数明显高于CVP+G-CSF动员方案组(p=0.002和p=0.019)。预处理后所有病例均达到骨髓抑制,CEP+G-CSF和CVP+G-CSF动员方案组WBC数恢复到≥1.0×109/L的平均时间分别为11.4和12.3天(p﹥0.05),Plt数恢复到≥50×109/L的平均时间分别为18.6和19.3天(p﹥0.05)。结论:自体外周血干细胞移植治疗NHL疗效显著,CEP或CVP联合G-CSF方案行外周血干细胞动员均安全有效,临床效果满意,CEP+G-CSF方案动员外周血干细胞效果更好。  相似文献   

14.
目的 比较FenwalCS 3000plus及CobeSpectra两种血细胞分离机分离外周血造血干细胞的效果。方 法 共有76名供者入组。FenwalCS 3000plus组31例,平均年龄(39.1±12.9)岁,共循环38次;CobeSpectra组 45例,平均年龄(38.2±11.2)岁,共循环65次。比较两组采集物白细胞总数、单核细胞百分率、采集物单核细胞中 CD34+细胞百分率。结果 两组采集物的白细胞计数无明显统计学差异;FenwalCS 3000plus组单核细胞百分率 高于CobeSpectra组。两组采集物中CD34+细胞百分率无明显统计学差异。CobeSpectra组采集物中单核细胞百 分率与白细胞数负相关。两组单核细胞百分率、两组白细胞数均与CD34细胞百分率无相关性。结论 本组资料 显示在分离外周血干细胞方面FenwalCS 3000plus与CobeSpectra之间没有差异。  相似文献   

15.
为了评价Cobe Spectra(Version6.1)和Fenwal CS 3000 Plus两种血细胞分离机在造血干/祖细胞采集中的采集效能,对36人64次外周血造血干/祖细胞的采集进行了回顾性分析.20人42次使用Cobe Spectra采集,16人22次使用Fenwal CS 3000 Plus采集对CD34^ 细胞采集量、采集效率以及红细胞与血小板的采集量进行比较,结果表明:Cobe Spectra和Fenwal CS 3000 Plus在CD34^ 细胞采集量和采集效率上无显著差异?CD34^ 细胞采集量与供者白细胞、单核细胞、造血祖细胞、CD34^ 细胞的动员情况呈正相关,在多因素stepwise线性回归模型中,采集前外周血干/祖细胞浓度是唯一有意义的影响因素,Fenwal CS 3000 Plus的采集效率与外周血单核细胞量呈负相关。Fenwal CS 3000 Plus对红细胞的收集量显著高于Cobe Spectra,并且采集后供者外周血血小板降低程度较Cobe Spectra更严重。结论:Cobe Spectra(Version 6.1)和Fenwal CS 3000 Plus在CD34^ 细胞的采集能力上无显著差别。当外周血单核细胞数量高,或是血型不合移植的及血小板减少的供者,推荐使用Cobe Spectra血细胞分离机.  相似文献   

16.
目的考察利用COBE Spectra血细胞分离机采集幼儿外周血造血干/祖细胞的影响因素。方法根据患儿体重(≤15 kg,>15 kg)、采集时外周血白细胞计数(≤5×109/L,>5×109/L)、淋巴细胞+单核细胞比例(≤18%,>18%)、Hct(≤25%,>25%)、采血速度(≤20 mL/min,>20 mL/min)血细胞分离机报警次数(≤3次,>3次)分别分组,比较2组患儿的每公斤体重单个核细胞计数、CD34+细胞计数及所占比例。结果淋巴细胞+单核细胞比例>18%组与≤18%组比较,Hct>25%组与≤25%组比较,血细胞分离机报警次数≤3次组与>3次组比较,在每公斤体重单个核细胞计数、CD34+细胞计数及所占比例均有显著差异(P<0.01)。其余组别之间差异不显著(P>0.05)。结论采用COBE Spectra血细胞分离机采集幼儿外周血造血干/祖细胞时,淋巴细胞+单核细胞比例、患儿红细胞比积及血细胞分离机报警次数是影响采集得率的因素。  相似文献   

17.
BACKGROUND: Cryopreserved hematopoietic progenitor cells collected by apheresis from granulocyte–colony‐stimulating factor with or without chemotherapy–mobilized patients have become the preferred type of autograft to support treatment of diseases amenable to high‐dose chemotherapy. A novel apheresis system, the Spectra Optia v.5.0 (CaridianBCT), was constructed to meet certain shortcomings of manual apheresis systems such as the COBE Spectra MNC (CaridianBCT), including the need for continuous optical or manual monitoring and readjustment of buffy coat position and sensitivity to inconsistent blood flow. By use of optical sensors, which provide real‐time automatic interface (buffy coat) and collection line control, the Spectra Optia promises to automatically guide apheresis procedures, potentially freeing up operator time and reducing variability in collection efficiency (CE2). STUDY DESIGN AND METHODS: In a two‐center clinical trial, 35 autologous stem cell donors were subjected to apheresis with the Spectra Optia to validate feasibility and effectiveness of apheresis procedures. Results were compared to data from 80 autologous apheresis procedures with the COBE Spectra MNC. RESULTS: Usability and function of the automatic interface management were excellent. CD34+ cell quality, assessed by viability staining, colony‐forming unit–culture frequency, and engraftment kinetics, was equally good with both systems. CE2 of the Spectra Optia, calculated as CD34+ contents in the product divided by the number of CD34+ cells presented to the collection port, exceeded that of the COBE Spectra MNC. Spectra Optia product volumes were significantly smaller. Very high white blood cell and platelet counts modestly reduced CE2 with the Spectra Optia. CONCLUSION: The Spectra Optia is a novel automatic apheresis system supporting autologous stem cell collection with at least equal efficiency and superior user‐friendliness compared to the COBE Spectra MNC.  相似文献   

18.
异基因外周血造血干细胞移植后血型基因型与抗原的转变   总被引:1,自引:0,他引:1  
目的 探讨异基因外周血造血干细胞移植(Allo—PBSCT)后患者ABO、Rh血型的转变在血液病移植治疗中的意义。方法 选择2例非血源关系的供、受者作为研究对象,采用基因分型与血清学方法检测移植前后ABO、Rh血型的表达,追踪移植后患者血型基因型与抗原的转变。结果 2例患者分别在移植后第7天与第10天检测到供者的A、Rh(c)基因,第7天与第15天不同程度地表达供者的ABO、Rh血型抗原。结论 观察ABO与Rh血型的转变可作为植入证明的检测方法之一,且直观、迅速。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号