首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
There is a need for fast testing of drug candidates for properties of pharmacokinetics and pharmacodynamics importance, in particular lipophilicity and acidity. These two parameters can conveniently be estimated by gradient reversed-phase HPLC. Appropriate conventional organic solvent gradient and the new pH gradient HPLC procedures are presented. The chromatographic parameter of lipophilicity, log kw, can be determined from two organic solvent gradient runs instead of 6-8 runs necessary in the standard isocratic (polycratic) approach. The newly introduced pH gradient reversed-phase HPLC consists in a programmed increase during the chromatographic run of the eluting power of the mobile phase with regards to ionizable analytes. The eluting strength of the mobile phase increases due to its increasing (in case of acidic analytes) or decreasing (basic analytes) pH, whereas the content of organic modifier remains constant. It has been theoretically and experimentally demonstrated that the pKa and log kw values can be evaluated based on retention data from a pH gradient run, combined with appropriate data from two organic solvent gradient runs. The gradient HPLC-derived log kw parameters correlate well with analogous parameters determined isocratically as well as with reference lipophilicity parameter log P (logarithm of n-octanol/water partition coefficient). Also, the HPLC-derived pKa parameters correlate to the literature pKa values (w(w)pKa), conventionally determined by titrations in water. The approach described allows rapid and high-throughput assessment of log kw and pKa for large series of drugs candidates, also when the analytes are available in a form of mixture, e.g. produced by combinatorial synthesis.  相似文献   

2.
The purpose of this work was to propose a theoretical model of the combined pH/organic modifier gradient in reversed-phase high-performance liquid chromatography (RP HPLC) with special emphasis on its applicability to polyprotic analytes. The model was developed and approximated to be useful for a data set comprising organic modifier gradients obtained at different pH changes and different gradient durations. It was evaluated regarding its ability to describe experimental data. The chromatographic pK(a) and lipophilicity parameter, log k(w), were obtained by fitting to the proposed model and comparing to the literature values.  相似文献   

3.
In a series of reports published recently by our laboratory comprehensive theory and experimental conditions were established for reversed-phase high-performance liquid chromatography (RP HPLC) employing the programmed pH gradient of mobile phase. A procedure was developed providing, rapidly and conveniently, the acidity (pKa) of weak acids and bases and their lipophilicity (hydrophobicity) log kw. The basis of the double-gradient RP HPLC, employing simultaneous gradients of organic modifier content and mobile phase pH, was also elaborated. The fundamentals of the approach are presented briefly and systematically and its advantages and limitations are discussed. It is demonstrated that the newly introduced pH gradient method increases the analytical versatility of RP HPLC and our understanding of its physicochemical basis.  相似文献   

4.
The retention properties of calcitonins on a reversed-phase column are examined using salmon calcitonin as the model compound. The effect of the concentration of organic modifier, buffer strength, pH of the mobile phase, and ion-pair reagent are studied. In the absence of an ionic modifier in the eluent the calcitonin peak shapes are not symmetrical. The addition of 0.1% trifluoroacetic acid (TFA), however, results in good peak characteristics without the need to add nonvolatile salts. The retention of the calcitonins was found to be very sensitive to the concentration of the organic modifier (acetonitrile) present in the mobile phase. A change of pH between 2 and 5 has only a slight effect of the k' of salmon calcitonin, but the k' increases significantly at higher pH values. The addition of a phosphate buffer to the mobile phase and an increase in the buffer concentration (0-0.2 M) causes a decrease in the retention of salmon calcitonin. Evidence shows that reproducible, quantitatively measurable data can be obtained using reversed-phase chromatography if the ion-pairing reagent and organic modifier concentrations are carefully controlled. The system also shows a good selectivity for the calcitonin series. Therefore, both highly selective methods (qualitative) as well as quantitative methods for analytical, pharmaceutical, and manufacturing use can be developed by adjusting the high-performance liquid chromatography (HPLC) conditions as discussed.  相似文献   

5.
An HPLC method for the separation of six target alkaloids from Papaver somniferum L. (morphine, codeine, oripavine, thebaine, papaverine, and noscapine) was developed, optimized, and validated. The chromatographic behavior of these alkaloids was investigated using a reversed-phase chromatography at acidic and alkaline pH. The effects of ion-pairing agents, pH value of the mobile phase, concentration of the buffer components, mobile phase organic modifier, and column temperature were studied. Regardless of the large differences in their pKa values, all alkaloids were separated within a close retention window, and good peak shape was achieved for each of the six alkaloids. The proposed method has adequate selectivity, linearity, accuracy, precision, and reproducibility and is applicable for poppy straw.  相似文献   

6.
A review about the influence of mobile phase acid-base equilibria on the liquid chromatography retention of protolytic analytes with acid-base properties is presented. The general equations that relate retention to mobile phase pH are derived and the different procedures to measure the pH of the mobile phase are explained. These procedures lead to different pH scales and the relationships between these scales are presented. IUPAC rules for nomenclature of the different pH are also presented. Proposed literature buffers for pH standardization in chromatographic mobile phases are reviewed too. Since relationships between analyte retention and mobile phase pH depends also on the pKa value of the analyte, the solute pKa data in water-organic solvent mixtures more commonly used as chromatographic mobile phase are also reviewed. The solvent properties that produce variation of the pKa values with solvent composition are discussed. Chromatographic examples of the results obtained with the different procedures for pH measurement are presented too. Application to the determination of aqueous pKa values from chromatographic retention data is also critically discussed.  相似文献   

7.
The linear-solvent strength (LSS) model of gradient elution has been applied to estimate parameters of lipophilicity and acidity of a series of drugs and model chemicals. Apparent pKa values and log kw values for individual analytes were determined in 2-3 gradient runs. The first experiment (or first two experiments) uses a wide-range organic modifier gradient with pH chosen for suppressed ionization of the analyte. The result of this experiment allows an estimate of contents of organic modifier of the mobile phase (%B) providing the required retention coefficient, k, for the non-ionized analyte. The following experiment is carried out with the latter %B and a pH-gradient of the aqueous component of the eluent that is sufficient to overlap the possible pKa-value of the analyte. The initial pH of the buffer used to make the mobile phase is selected to insure that the analyte is in non-ionized form. The resulting retention time allows an estimate of PKa in a solvent of the selected %B. At the same time, estimates of log kw can also be obtained. The log kw parameter obtained from gradient HPLC by the approach proposed correlated well with the corresponding value obtained by standard procedure of extrapolation of retention data determined in a series of isocratic measurements. Correlation between log kw and the reference parameter of lipophilicity, log P, was very good for a series of test analytes and satisfactory for a structurally diverse series of drugs. The approach supported with specific detection procedures can be recommended for fast screening of lipophilicity of individual components of complex mixtures like those produced by combinatorial chemistry. The values of pKa obtained in a study were found to correlate with the literature pKa data determined in water for a set of aniline derivatives studied. In case of a series of drugs the correlation was less than moderate if the general procedure of pKa determination was applied.  相似文献   

8.
In an effort to gain insight into the relationship between stationary phase solvation and selectivity, the use of short- and medium-chained-length alcohols (methanol, n-propanol, n-butanol, and n-pentanol) as mobile phase modifiers in reversed-phase liquid chromatography (RPLC) was investigated to determine their impact on chromatographic selectivity. A wide range of mobile phase compositions was evaluated because of the large effect exerted by solvent strength on selectivity. Employing a set of six vanillin compounds as retention probes, evidence is presented to support the view that an increase in the hydrophobicity of the organic modifier used in RPLC can increase the selectivity of the C18 alkyl bonded phase while simultaneously decreasing the retention time of the eluting solutes. Thus, we are presented with an interesting paradox: higher selectivity and shorter retention times, which can be attributed to changes in either solvent selectivity and/or stationary phase solvation by the organic modifier.  相似文献   

9.
Summary The chromatographic properties of an alkylphosphonate-modified magnesia-zirconia composite stationary phase have been investigated by reversed-phase high-performance liquid chromatography with basic compounds as probes. The influence of organic modifier composition and mobile phase pH was studied. The new stationary phase, similar to a silica-based reversed-phase stationary phase, has hydrophobic properties, but greater pH stability. Use of the phase results in more symmetric peaks for basic compounds. A possible mechanism of retention of basic solutes on the new stationary phase is discussed. The chromatographic behavior of the basic solutes depends mainly on hydrophobic interactions between the solutes and the hydrophobic moiety of the stationary phase. Br?nsted acidic and basic sites on the surface of the new stationary phase play an important role in the retention of ionized solutes by ion-exchange interaction. Promising separations of some basic compounds have been achieved by use of methanolic TRIS buffer, pH 10.0, as the mobile phase.  相似文献   

10.
11.
12.
Direct and indirect reversed-phase (RP) high-performance liquid chromatographic methods were developed for the separation of enantiomers of 18 unnatural beta-amino acids, including several beta-3-homo amino acids. The direct separations of the underivatized analytes were performed on chiral stationary phases (CSPs) containing macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T column) and teicoplanin aglycone (Chirobiotic TAG column). The indirect method involved pre-column derivatization with a new chiral derivatizing agent (CDA), (S)-N-(4-nitrophenoxycarbonyl)phenylalanine methoxyethyl ester ((S)-NIFE), and subsequent separation of diastereomers on Discovery C18 and Hyperpep 300 C18 columns. The different methods were compared in systematic chromatographic examinations. The effects of organic modifier, mobile phase composition, pH and flow rate on the separation were investigated.  相似文献   

13.
An ab initio simulation of reversed-phase liquid chromatography for phenolic compounds was achieved based on molecular interaction energy values calculated using molecular mechanics calculations (MM2) of the CAChe program. The precision of the predicted retention factors from the molecular interaction energy values was equivalent to the predicted retention factors based on octanol-water partition coefficients (log P) calculated using the molecular orbital package (MOPAC). The prediction of retention factors of phenolic compounds in reversed-phase liquid chromatography in a given pH eluent was possible using the predicted dissociation constant (pKa) from the atomic partial charge without a chemical experiment if the organic modifier effect was known.  相似文献   

14.
Novel chiral stationary phases (CSPs) based on zwitterionic Cinchona alkaloid-type low-molecular mass chiral selectors (SOs), as they have been reported recently, were investigated in HPLC towards effects on their chromatographic behavior by mobile phase composition. Mobile phase characteristics like acid-to-base ratio and type of acidic and basic additives as well as effect of type of bulk solvents in nonaqueous polar organic and aqueous reversed-phase (RP) eluent systems were varied in order to illustrate the variability and applicability of zwitterionic CSPs with regard to mobile phase aspects. Chiral SOs of the five zwitterionic CSPs investigated herein contained weak and strong cation-exchange (WCX, SCX) sites at C9- and C6′-positions of the Cinchona alkaloid scaffold which itself accommodated the weak anion-exchange (WAX) site. The study focused on zwitterion-exchange (ZX) operational mode and chiral amino acids as target analytes. Besides, also the anion-exchange (AX) mode for chiral N-blocked amino acid analytes was considered, because of the intramolecular counterion (IMCI) property available in AX mode. Overall, most general and successful conditions in ZX mode were found to be weakly acidic methanolic mobile phases. In aqueous eluents RP contributions to retention came into play but only at low organic modifier content because of the highly polar character of zwitterionic analytes. At higher acetonitrile content, HILIC-related retention phenomena were observed. When using weakly basic eluent system in AX mode remarkably fast enantiomer separations involving exclusion phenomena were possible with one enantiomer eluting before and the other after void volume.  相似文献   

15.
Abstract

The retention behaviour of eleven derivatives of counarin was investigated by reversed-phase (RP) thin-layer and high performance liquid chromatography. The linear relationships between log k'or RM values and the content of organic modifier in the aqueous mobile phase obtained for wide composition ranges indicate that the plots can be used to determine RMw and log kw values by extrapolation to pure water. The effects of individual substituants on the retention and the correlation between TLC and HPLC data was analysed.  相似文献   

16.
Abstract

Fractionation of amino acid specific tRNAs by descending salt gradient on a reversed-phase high-performance liquid chromatography column is demonstrated. Stationary phase variables such as n-alkyl chain length and silica type are discussed in terms of stability and selectivity. Mobile phase parameters including salt concentration, organic modifier, pH, and temperature are investigated. The concentration of organic modifier to adjust elution profiles can be critical in terms of tRNA retention.  相似文献   

17.
Computer models have been widely used to predict the chromatographic behaviour of liquid chromatography systems. With the introduction of mass spectrometric detection and the use of lower mobile phase flow rates with conventional LC equipment, the influence of the dwell volume on the shape of the gradient curve becomes an issue in predicting the retention times. A new straight forward algorithm is proposed for the modelling of retention times in reversed-phase LC, taking the effect of the dwell volume on the gradient shape into account. The results show that the dwell volume has a large effect at lower flow rates and on the retention times of the analytes eluting at the end of fast gradient curves. The proposed model is able to make reliable predictions and can be helpful in LC-MS method development.  相似文献   

18.
In reversed-phase high performance liquid chromatography, the logarithm of the retention factor, log k, is usually correlated with the logarithm of the octanol-water partition coefficient, log Kow. The k and Kow of an ionizable analyte are greatly influenced by the mobile phase pH. In this paper, log kw of diprotic o-phthalic, 3-nitrophthalic, and 4-nitrophthalic acids, are obtained by extrapolation to pure aqueous fraction of mobile phase in ion-suppression reversed-phase high performance liquid chromatography with acetic acid and perchloric acid as the ion-suppressors. The Kow values of the three analytes are calibrated according to the apparent octanol-water partition coefficient, Kow, under different pH conditions, and the log K"ow values show a much better correlation with log kw than do log Kow. The influences of two ion-suppressors, acetic and perchloric acids, on the retention behavior of these diprotic acids at different pH are contrasted. An abnormal trend is found in the k vs. pHw plot of the acetic acid system when the methanol content is low. A possible reason is that acetic acid is an even stronger organic modifier than methanol, besides being an ion-suppressor. The results make the selection of mobile phase for the separation of acidic compounds by ion-suppression reversed-phase high performance liquid chromatography direct, accurate, and practical.  相似文献   

19.
Chromatographic resolution of four flavanones is achieved by reversed-phase high-performance liquid chromatography (HPLC) on a chiral stationary phase based on silica coated with a (2-hydroxy-3-methacryloyloxypropyl beta-cyclodextrin-co-N-vinylpyrrolidone) copolymer. The influence of the mobile phase water content and the nature of the organic modifier on the retention and resolution is evaluated. Monosubstituted flavanones are better resolved than the unsubstituted one. Nevertheless, the 6- and 7-methoxy substituents enhance retention and chiral recognition to polymeric beta-cyclodextrin stationary phase less than the 6-hydroxy group.  相似文献   

20.
The effects of pH, ionic strength, organic modifier, heptanesulphonic acid and citric acid content of a high-performance liquid chromatography mobile phase on the chromatographic and electrochemical behaviour of norepinephrine, epinephrine, dopamine, 3,4-dihydroxybenzylamine, 3,4-dihydroxyphenylethylene glycol, 3,4-dihydroxyphenylalanine and 3,4-dihydroxyphenylacetic acid in a reversed-phase system have been systematically studied. Optimal mobile phase conditions have been derived allowing the separation and reductive-mode detection of these compounds, applicable to both alumina and ion-paired solvent extracts of plasma. It is demonstrated that mobile phase composition significantly affects the sensitivity of a triple-electrode electrochemical detection system, in reductive and oxidative modes, and that electrochemical pre-treatment of mobile phase is required to attain maximum detector sensitivity in the reductive mode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号