首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(10):1746-1757
Bifunctional combination of carbon nanotubes and ionophore is introduced for anodic stripping analysis of lead (Pb2+). Carbon nanotubes are employed to improve the detection sensitivity due to their excellent electrical conductivity and strong adsorption ability. An ionophore is utilized for its excellent selectivity toward Pb2+. The proposed carbon nanotubes/ionophore modified electrode shows improved sensitivity and selectivity for Pb2+. Low detection limit (1 nM), wide linear range (5 nM–8 µM) and excellent selectivity over other metal ions (Cd2+, Cu2+, and Hg2+) was obtained. The practical application has been carried out for determination of Pb2+ in real water samples.  相似文献   

2.
《Analytical letters》2012,45(1):17-28
ABSTRACT

A PVC membrane electrode for Pb2 ions based on tetraphenylporphyrin was prepared. The sensor exhibits a Nernstian response for lead ions over a wide concentration range (1.0 x 10?5-1.0 x 10?2 M). The limit of detection is 8.5 x 10?6M. It has a response time of 15 s and can be used for at least three months without any divergence in potential. The proposed electrode shows a fairly good discriminating ability towards Pb2 ion in comparison to some alkali, alkaline earth, transition and heavy metal ions. The electrode can be used in the pH range 5.0 to 7.5. It was used as an indicator electrode in potentiometric titration of lead ion.  相似文献   

3.
A sensitive voltammetric method for detection of trace heavy metal ions using chemically modified carbon nanotubes (CNTs) electrode surfaces is described. The CNTs were covalently modified with cysteine prior to casting on electrode surfaces. Cysteine is an amino acid with high affinities towards some heavy metals. In this assay, heavy metals ions accumulated on the cysteine‐modified CNT electrode surfaces prior to being subjected to differential pulse anodic stripping voltammetry analysis. The resulting peak currents were linearly related to the concentrations of the metal ions. The method was optimized with respect to accumulation time, reduction time and reduction potential. The detection limits were found to be 1 ppb and 15 ppb for Pb2+ and Cu2+ respectively. The technique was used for the detection of Pb2+ and Cu2+ in spiked lake water. The average recoveries of Pb2+ and Cu2+ were 96.2% and 94.5% with relative standard deviations of 8.43% and 7.53% respectively. The potential for simultaneous detection of heavy metal ions by the modified CNTs was also demonstrated.  相似文献   

4.
A novel selective membrane electrode for determination of ultra-trace amount of lead was prepared. The PVC membrane containing N,N′-dimethylcyanodiaza-18-cown-6 (DMCDA18C6) directly coated on a graphite electrode, exhibits a Nernstian response for Pb2+ ions over a very wide concentration range (from 1.0×10−2 to 1.0×10−7 M) with a limit of detection of 7.0×10−8 M (∼14.5 ppb). It has a fast response time of ∼10 s and can be used for at least 2 months without any major deviation in potential. The electrode revealed very good selectivity with respect to all common alkali, alkaline earth, transition and heavy metal ions. The proposed sensor was used as an indicator electrode in potentiometric titration of lead ions and in determination of lead in edible oil, human hair and water samples. The proposed sensor was found to be superior to the best Pb2+-selective electrodes reported in terms of detection limit and selectivity coefficient.  相似文献   

5.
《Comptes Rendus Chimie》2016,19(7):789-797
A smectite-based inorganic-organic hybrid material was prepared by a one-step intercalation of cetyltrimethylammonium ions and thiourea within the interlayer space of montmorillonite (MT). The surface and textural properties of the resulting material were examined using several techniques (X-ray diffraction, elementary analysis and N2 adsorption-desorption experiments (BET method)) that demonstrated the presence of both modifiers in the clay mineral structure. The presence of thiourea molecules in the modified MT greatly improved its ability towards the fixation of Pb2+ and Cd2+ ions when the organoclay material was used for sensing purposes as a glassy carbon electrode modifier. The electro-analytical procedure was based on the chemical accumulation of both analytes under open-circuit conditions, followed by the detection of the preconcentrated species using square wave voltammetry. Upon optimization of different parameters likely to influence the electrode response, linear calibration graphs were obtained in the concentration ranges from 0.1 to 1 μM and 0.01 to 0.1 μM for Cd2+ and Pb2+, respectively, leading to low limits of detection (4.2 × 10−10 M for Pb2+and 1.2 × 10−9 M for Cd2+).  相似文献   

6.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

7.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

8.
《Electroanalysis》2004,16(5):360-366
The performance of a remote stripping sensor based on mercury microelectrodes (MM‐RS) for the in situ detection of trace metals in aquatic systems, was investigated. The submersible device employed here consists of a single mercury‐coated platinum disk microelectrode assembled in a two‐electrode cell configuration, and connected remotely by a 30 m long shielded cable. First, the MM‐RS device is characterized in Ru(NH3) and Pb2+ synthetic aqueous solutions by applying cyclic voltammetry and anodic stripping voltammetry (ASV), respectively. The results obtained show that the small electrode dimensions and the related low currents involved, the long remote connection cable or the use of a two‐electrode system do not cause noise effects or uncompensated resistance problems in the measurements. Using square‐wave voltammetry in the stripping step, linear calibration graphs for Pb2+ ions over the concentration range 1×10?9?5×10?7 M were obtained, and a detection limit, DL, of 0.15 nM was found. The relative standard deviation (RSD), at 5×10?8 M Pb2+ level, was within 5%. The effect of humic acid and of sodium dodecylsulfate surfactants on the stripping responses was also investigated. The performance of the submersible MM‐RS system was tested for the in situ monitoring of the labile fraction of lead and copper on a site of the Lagoon of Venice. In situ Pb2+ and Cu2+ concentrations were monitored for about 8 hours, by leaving the sensor immersed in the lagoon waters (2 m depth) and recording the response every hour. Under these field conditions, reliable in situ data for the labile fraction of these metal ions with a satisfactory precision, the RSD being within 7 and 9 % for lead and copper, respectively, were obtained.  相似文献   

9.
In the present work, a sensitive, facile and disposable sensing platform for trace analysis of heavy metal ions was developed at the Bi modified graphene‐poly(sodium 4‐styrenesulfonate) composite film screen printed electrode (GR/PSS/Bi/SPE). The GR/PSS/Bi/SPE improved sensitivity and linearity due to the functionalization of graphene with negatively charged PSS providing more absorbing sites. The detection limit of the GR/PSS/Bi/SPE is found to be 0.042 µg L?1 for Cd2+ and 0.089 µg L?1 for Pb2+ with linear responses of Cd2+ and Pb2+ in the range of 0.5–120 µg L?1. Finally, the practical application was confirmed in real water with satisfactory results.  相似文献   

10.
《Electroanalysis》2018,30(3):533-542
A simple and highly sensitive electrochemical sensor COOH−C4 derived from dicarboxyl‐calix[4]arene modified on a screen printed gold electrode (Au) was developed for the determination of lead ions in water samples. A 3‐mercaptopropionic acid (MPA) monolayer was used as a template on the gold electrode for the surface modification with dicarboxyl‐calixarene. The modified electrodes were surface‐characterized using Fourier Transform infrared spectroscopy (FTIR). The data obtained proved the confirmation of each stage of the electrode modification. The electrochemical analyses of the COOH−C4 electrode showed an enhanced electrocatalytic activity and higher current towards Pb2+ ions as compared to the bare Au and MPA/Au electrodes. Under optimum conditions, the differential pulse voltammetry response of COOH−C4 displayed a wide linear response ranging from 280–2500 μg/L for Pb2+ with a detection limit of 6.2 μg/L. In addition, the fabricated electrode showed a high selectivity and stability towards the Pb2+ ions in presence of possible interfering species. The present method was successfully applied to determine Pb2+ ions in real samples with satisfactory precision, with a relative standard deviation of 3.12 % and an acceptable recovery of 92 %, which demonstrated the potential application of dicarboxyl‐calix[4]arene modified on electrodes for heavy‐metal sensing.  相似文献   

11.
《Analytical letters》2012,45(11):2169-2181
ABSTRACT

A new PVC membrane for zinc ions based on DBDA15C4 as membrane carrier was prepared. The electrode shows a linear stable response over a wide concentration range (5.0 × 10?5-1.0 × 10?1 M) with a slope of 22 mV/decade and a limit of detection of 3.0 × 10?5 M (2.0 μg/ml). It has a very short response time of less than 5 s and can be use for at least 11 months without any divergence in potential. The zinc ion-selective electrode exhibited very good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions and could be used in a pH range 1.5-7.0. It was successfully applied for the direct determination of zinc in a pharmaceutical sample and, as an indicator electrode, in potentiometric titration of Zn2+ ions.  相似文献   

12.
《Analytical letters》2012,45(8):1501-1512
ABSTRACT

A poly (vinyl chloride) (PVC) based membrane of cephaloridine as a novel ionophore exhibits good potentiometric response for Cu2+ over a wide concentration range (10?5-10? M) with a slope of 28.5 mV per decade. The detection limit is 3.5 × 10?6 M. The response time of the sensor is < 60 s. The electrode has been used for a period of one month and exhibits good selectivity towards Cu2+ in comparison to alkali, alkaline earth, transition and heavy metal ions, with no interference caused by Pb2+ Cd2+ and Fe2+ which are known to interfere with many other copper electrodes. The electrode can be used in the pH range from 4.0 to 6.5 and it can also be used in partially non-aqueous medium having up to 10 (v/v) non aqueous content and in the presence of cationic surfactants at concentrations less than 10?3 M.  相似文献   

13.
A PVC membrane electrode for Hg(II) ions, based on a new cone shaped calix[4]arene (L) as a suitable ionophore was constructed. The sensor exhibits a linear dynamic in the range of 1.0 × 10?6–1.0 × 10?1 M, with a Nernstian slope of 29.4 ± 0.4 mV decade?1, and a detection limit of 4.0 × 10?7 M. The response time is quick (less than 10 s), it can be used in the pH range of 1.5–4, and the electrode response and selectivity remained almost unchanged for about 2 months. The sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, and some transition and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Hg2+ ions with potassium iodide, and the direct determination of mercury content of amalgam alloy and water samples.  相似文献   

14.
The Cu (II) imprinted polymer glassy carbon electrode (GCE/Cu-IP) was prepared by electropolymerization of pyrrole at GCE in the presence of methyl red as a dopant and then imprinting by Cu2+ ions. This electrode was applied for potentiometric and voltammetric detection of Cu2+ ion. The potentiometric response of the electrode was linear within the Cu2+ concentration range of 3.9 × 10?6 to 5.0 × 10?2 M with a near-Nernstian slope of 29.0 mV decade?1 and a detection limit of 5.0 × 10?7 M. The electrode was also used for preconcentration anodic stripping voltammetry and results exhibited that peak currents for the incorporated copper species were dependent on the metal ion concentration in the range of 1.0 × 10?8 to 1.0 × 10?3 M and detection limit was 6.5 × 10?9 M. Also the selectivity of the prepared electrode was investigated. The imprinted polymer electrode was used for the successful assay of copper in two standard reference material samples.  相似文献   

15.
《Analytical letters》2012,45(10):1850-1866
Abstract

This work introduces a unique ionophore for the selective determination of Sr2+ ions. The ionophore, salicylaldehyde thiosemicarbazone (ST), presented a high affinity toward the strontium cations. The demonstrated characteristics of the sensor included a linear dynamic range between 1.0 × 10?6 and 1.0 × 10?2 M with a near Nernstian slope of 29.4±0.5 mV per decade, a detection limit of 4.8 × 10?7 M, and a very good selectivity for Sr2+ over other cations in a wide pH range (2.8–10.4). The sensor possessed the advantages of short conditioning time, fast response time (< 10 s), and, especially, good selectivity toward the transition and heavy metal ions as well as some mono, di, and trivalent cations. Concerning the electrode lifetime, no considerable potential divergence was noticed for at least 10 weeks. The developed sensor was successfully used as an indicator electrode in the Sr2+ titration with EDTA from binary mixtures, and the Sr2+ monitoring in mixtures of three and five different ions.  相似文献   

16.
A new PVC-membrane electrode for Co2+ ions based on N,N′-di(thiazol-2-yl)formimidamide (TF) as membrane carrier has been developed. The electrode resulted in Nernstian response (29.5?±?0.4?mV decade?1) for Co2+ ion over a wide concentration range (2.5?×?10?7 ?1.0?×?10?1?M) with a detection limit of 6.1?×?10?8?M. The sensor has a response time of about 10?s, and can be used for at least 2 months without observing any deviation from the Nernstain response. The electrode revealed good selectivity towards cobalt(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions and could be used in the pH range 2.0–7.0. The electrode was used for determination of Co2+ in real samples.  相似文献   

17.
In this study, a carbon paste electrode modified with a novel 1-(3-aminopropyl) imidazole functionalised crosslinked chlorosulfonated poly(styrene)-divinyl benzene polymer was used for selective and sensitive determination of the trace amounts of Pb2+, Cu2+ and Hg2+ ions by square wave anodic stripping voltammetry. The effect of some parameters such as paste composition, pH, preconcentration time, reduction potential and time, type of supporting electrolyte and potential scan rate on the determination of metal ions were investigated to find the optimal conditions. The effective open-circuit accumulation of the studied metal ions was succeeded only by the modification of the carbon paste electrode with functional polymer. For 6 min open-circuit preconcentration, the detection limit of Pb2+, Cu2+ and Hg2+ was found to be 5, 9 and 14 µgL?1, respectively at 100 mVs?1. The results confirmed that the lower concentration levels of these trace metal ions can be determined with the increase of preconcentration time and/or potential scan rate. Good detection limits and large dynamic concentration ranges were also obtained for their binary and ternary mixtures. The optimised method was successively applied to determine the concentration of Pb2+, Cu2+ ions in the tap water sample and Cu2+ ion in the waste water sample in the presence of possible interfering species (RSD<1%, recoveries 96–110% for 4 min preconcentration).  相似文献   

18.
In this paper a carbon ionic liquid electrode (CILE) was fabricated by using ionic liquid 1‐ethyl‐3‐methylimidazolium ethylsulphate ([EMIM]EtOSO3) as the modifier and further used as the working electrode for the sensitive anodic stripping voltammetric detection of Pb2+. The characteristics of the CILE were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). In pH 4.5 NaAc‐HAc buffer Pb2+ was accumulated on the surface of CILE due to the extraction effect of IL and reduced at a negative potential (‐1.20 V). Then the reduced Pb was oxidized by differential pulse anodic stripping voltammetry with an obvious stripping peak appeared at ?0.67 V. Under the optimal conditions Pb2+ could be detected in the concentration range from 1.0 × 10?8 mol/L to 1.0 × 10?6 mol/L with the linear regression equation as Ip(μA) = ?0.103 C (μmol/L) + 0.0376 (γ = 0.999) and the detection limit as 3.0 × l0?9 mol/L (3σ). Interferences from other metal ions were investigated and Cd2+ could be simultaneously detected in the mixture solution. The proposed method was further applied to the trace levels of Pb2+ detection in water samples with satisfactory results.  相似文献   

19.
4,13-Didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) has been explored as a neutral ionophore for preparing polyvinyl chloride (PVC)-based membrane sensor selective to lead(II). The optimized membrane incorporating kryptofix22DD as the active material, nitrobenzene as plasticizer and sodium tetraphenylborate as an anion excluder and membrane modifier in PVC (in the weight ratio of 5.0: 63.0: 2.0: 30.0, respectively) was directly coated on the surface of graphite rod. The sensor exhibits a Nernstian slope (29.4 mV/decade) in the concentration range of 1.0 × 10–5 to 1.0 × 10–1 M Pb2+. The detection limit of the sensor is 6.5 × 10–6 M. The proposed sensor has a fast response time (~10 s), a satisfactory reproducibility and relatively long lifetime. The electrode shows high selectivity toward Pb2+ ion in comparison to other common cations. The proposed sensor is suitable for use in aqueous solutions in a wide pH range of 2.0–10.0. It was used as an indicator electrode for the end point detection in the potentiometric titration of Pb2+ ion with ethylenediaminetetraacetic acid (EDTA) and sodium iodide (NaI) solutions. The proposed sensor was successfully applied for the recovery of Pb2+ ions spiked in real water samples.  相似文献   

20.
A composite multiwalled carbon nanotube polyvinyl chloride electrode based on 7,16‐dibenzyl‐1,4,10,13‐tetraoxa‐7,16‐diazacyclooctadecane (DBDA18C6) as Sm3+ ionophore is reported. This potentiometric sensor showed a wide linear working range, 1×10?2–1×10?8 M, Nernstian slope, 20.2±0.48 mV per decade and a limit of detection, 6.3±0.36×10?9 M. It works in the pH range 2.5–8.5 and shows a good selectivity over a number of metal ions. It has been found suitable for the analysis of ores and industrial effluents. The electrode surface is characterized by FRA and AFM.  相似文献   