首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A new ion selective electrode for salicylate based on N,N'-(aminoethyl)ethylenediamide bis(2-salicylideneimine)binuclear copper(Ⅱ)complex[Cu(Ⅱ)_2-AEBS]as an ionophore was developed.The electrode has a linear range from1.0×10~(-1) to 5.0×10~(-7) mol·L~(-1) with a near-Nernstian slope of(-55±1)mV/decade and a detection limit of 2.0×10~(-7) mol·L~(-1) in phosphorate buffer solution of pH 5.0 at 25℃.It shows good selectivity for Sal~- and displaysanti-Hofmeister selectivity seoquence:Sal~->SCN~->ClO_4~->I~->NO_2~->Br~->NO_3~->CI~->SO_3~(2-)>SO_4~(2-)The proposed sensor based on binuclear copper(Ⅱ)complex has a fast response time of 5-10 s and can be used forat least 2 months without any major deviation.The response mechanism is discussed in view of the alternating cur-rent(AC) impedance technique and the UV-vis spectroscopy technique.The effect of the electrode membranecompositions and the experimental conditions were studied.The electrode has been successfully used for the deter-mination of salicylate ion in drug pharmaceutical preparations.  相似文献   

2.
郎建平  蔡进华 《结构化学》1995,14(4):297-299
StructureofCopper(Ⅱ)Bis(piperidyldithiocarbamate)LangJian-ping;LuJian-Mei;BianGuo-Qing(DepartmentofChemistry,SuzhouUniversity...  相似文献   

3.
In the ethanol solvent, a nickel(Ⅱ) complex Ni(C12H10N2O2S)2 upon reaction of 2'-(2-thienylidene)-hydroxybenzoylhydrazide with nickel acetate was synthesized, and its structure was characterized by IR, UV, elemental analysis and X-ray diffraction analysis. The crystal belongs to monoclinic system, space group C2/c with a = 22.052(3), b = 5.9681(6), c = 18.522(2) (A), β = 110.679(4)° , V = 2280.6(4) (A)3, Z = 4, Mr = 551.27, μ = 1.606 mm-1, Dc = 1.075 g/cm3, F(000) = 1136 and Rint = 0.0556. The nickel(Ⅱ) atom in the compound is four-coordinated with two nitrogen atoms from amide and two oxygen atoms from keto group. The biological activities have been measured, show- ing the compound exhibits better anti-bacterial activity than the ligand.  相似文献   

4.
5.
1 INTRODUCTION The researches on organic polyamines are currently of great interest because of their potential applications as useful organic ligands, in which the amine nitrogen atoms have strong coordination ability to the transition metal ions. Their transition metal complexes play an excellent role in catalysis and the mimic studies on superoxide dismutase and chlorophyll[1~6]. N,N,N?,N?-Tetrakis(3-ami- nopropyl) ethylenediamine has been extensively stu- died[7~9], but few new ineq…  相似文献   

6.
合成了一类新的金属配合物[Cu(sampn)CuL](sampn^4-:N,N′-1,2-丙水杨酰胺根离子;L:2,2-联吡啶或1,10-菲绕啉),经元素分析、IR、电子光谱等手段推定配合物具有酚氧桥结构,Cu(Ⅱ)离子和配位环境为畸变四方构型,测定了配合物的变温磁化率,其数值用量二乘法与修正的Bleaney-Bowers方程拟合,从中得到较大的θ值,表明双核分子间有较大的分子间相互作用。  相似文献   

7.
IntroductionThe synthesis and characterization of the novelcomplexes with polycarboxylate groups are activefields currently due to their diverse intriguingstructures and potential properties as new materi-als[1_ 3 ] . 1 ,2 ,4,5 - Benzenetetracarboxylic acid( H4tcb) has a versatile coordination behavior sinceit can bridge metal centers in many modes,gener-ating various and sometimes surprising moleculararchitectures. Therefore,numerous complexeswith ligand H4TCB have been extensively stud-ied…  相似文献   

8.
Cleavage of DNA pUC19 by [Cu(saldien)(NH3)]C12 (here, saldien=bis(salicylicdene)-diethylenetriamine) was investigated at different pHs, times, concentrations, and 37℃. It wasfound that the copper( Ⅱ ) complex could cleave DNA without added coreactants.  相似文献   

9.
《结构化学》2004,23(3):242-246
The reaction of di(2-pyridyl)ketone with ethylenediamine produced hexadentate Schiff base 1 which can be reduced to form a new ligand N,N-bis(di(2-pyridyl)-methyl)ethylene- diamine (BDPM) in ethanol solution. The two compounds were characterized by elemental analyses and spectroscopic methods. Their structures were determined by X-ray diffraction study. Crystal data for 1: C24H20N6, Mr = 392.5, monoclinic, P21/c, a = 13.871(3), b = 13.510(2), c = 12.153(2) ? b = 112.97(2)? Z = 4, V = 2094.1(6) ?, Dc = 1.245 g/cm3, m(MoKa) = 0.078 mm-1, F(000) = 824, the final R = 0.0545 and wR = 0.0557 for 2048 observed reflections (I > 2s(I)); for BDPM: C24H24N6, Mr = 396.49, monoclinic, C2/c, a = 21.411(3), b = 8.053(1), c = 11.868(1) ? b = 92.63(1)? Z = 4, V = 2044.2(4) 3, Dc = 1.288 g/cm3, m(MoKa) = 0.080 mm-1, F(000) = 840, the final R = 0.0401 and wR = 0.0939 for 1673 observed reflections (I > 2s(I)).  相似文献   

10.
The synthesis and characterization of the copper (II) complex [Cu2(OOCCH = C(CH3)Fc)3(phen)2]CIO4 · 2H2O (1) are reported. The structure of the complex was determined by single‐crystal X‐ray analysis. The compound crystallizes in the monoclinic system, space group Pc, with Z =2, a = 1.2799(4) nm, b =0.9969 (4) nm, c = 2.5228 nm, and β = 91.576 (1) °. The cationic part of 1 indicates a penametallic core in which three 3‐ferrocenyl‐2‐crotonic acid salt (FCA) groups act as (O, O') bridging ligands between two copper (II) ions with a square‐pyramidal environment. Cyclic voltammetric experiments in acetonitrile have been performed mainly to examine the Fe(II) → Fe(III) one‐electron oxidation in FCA and its complex. The variable‐temperature magnetic susceptibility measurements revealed very weak intramolecular anti‐ferromagnetic coupling. Fitting parameters are 2J = ‐0.2 cm?1, g = 2.114, and θ = 0K.  相似文献   

11.
本文报道了一种以牛磺酸双核铜络合物为中性载体的硫氰酸根PVC膜电极。该电极对硫氰酸根有良好的电位响应并呈现出anti-Hofmeister行为,其选择性顺序SCN->I->ClO4->Sal->NO3-> NO2-> Br- > Cl- > SO3-> SO4 2-。在20℃ pH 5.0的磷酸缓冲溶液中,其线性范围为1.0´10 -1~ 1.0´10-6mol×L-1,检测线为8.0×10 -7mol•L-1,斜率为 -56.5 mV/pcSCN-。紫外、红外和交流阻抗研究表明电极的高选择性与载体的立体结构和分析物与中心金属离子的作用相关。将该电极用于废水和人体尿液中硫氰酸根的测定,获得了较满意的结果。  相似文献   

12.
归国风  柴雅琴  袁若  孙爱丽  王福昌 《化学学报》2006,64(21):2185-2189
研制了基于N,N'-亚乙基(μ-5,5-亚甲基-二水杨醛根)(乙酰丙酮根)合二铜(II) [Cu2(II)-MDSBAE]金属配合物为中性载体的阴离子选择性电极. 试验表明, 以Cu2(II)-MDSBAE金属配合物为中性载体的电极对SCN具有良好的电位响应特性, 且呈现反Hofmeister行为,其选择性序列为: SCN>Sal>I>ClO4>NO3>Br>NO2>Cl≈SO32->SO42-. 在pH 5.0的磷酸盐缓冲体系中, 电极电位呈现近能斯特响应, 线性响应范围为1.0×10-6~1.0×10-1 mol/L, 斜率为-53. 6 mV/dec (25 ℃), 检测下限为8.1×10-7 mol/L. 用交流阻抗研究了电极的响应机理, 并用紫外可见光谱技术测定了电极载体与SCN, Sal, I, ClO4和NO3离子间的配位数及缔合常数. 将该电极用于实验室废水和工业废水中硫氰酸根的检测, 其结果令人满意.  相似文献   

13.
许文菊  袁若  柴雅琴 《中国化学》2009,27(1):99-104
本文以2,9,16,23-四硝基酞菁铜(II) (Cu(II)TNPc) 和2,9,16,23-四氨基酞菁铜(II) (Cu(II)TAPc) 为载体制备PVC聚合膜,构建了水杨酸根选择性电极,并探讨了该电极的选择性响应性能。研究了增塑剂的性质、载体的含量及阴、阳离子添加剂对电极电位响应的影响。结果表明,基于Cu(II)TNPc为载体的PVC膜电极对水杨酸根 (Sal-) 呈现出优先选择性电位响应。具有最佳电位响应的电极的膜组成是:(w/w) 3.0% Cu(II)TNPc,67.0% o-NPOE,29.5% PVC和0.5% NaTPB。基于该组成的电极的线性响应范围为1.0×10-1-9.0×10-7 mol·L-1,检测下限为7.2×10-7 mol·L-1,斜率为-59.8±0.5 mV/decade;其响应快速,稳定性好,适宜的pH范围是3.0-7.0。并成功运用于了实际样品中水杨酸含量的测定,获得令人满意的结果。  相似文献   

14.
MOGHIMI Ali 《中国化学》2008,26(10):1831-1836
A novel, simple, sensitive and effective method has been developed for preconcentration of thallium on N,N’-bis(3-methylsalicylidene)-ortho-phenylenediamine (MSOPD) adsorbent in a pH range 5.0—10.0, prior to its spectrophotometric determination, based on the oxidation of bromopyrogallol red at λ=520 nm. This method makes it possible to quantitize thallium in a range of 3.6×10-9 to 2.0×10-5 mol/L, with a detection limit (S/N=3) of 1.42×10-9 mol/L. This procedure has been successfully applied to determine the ultra trace levels of thallium in the environmental samples, free from the interference of some diverse ions. The precision, expressed as relative standard deviation of three measurements, is better than 2.9%.  相似文献   

15.
《Electroanalysis》2006,18(16):1620-1626
A polyvinylchloride membrane sensor based on N,N′‐bis(salecylidene)‐1,2‐phenylenediamine (salophen) as membrane carrier was prepared and investigated as a Al3+‐selective electrode. The sensor exhibits a Nernstian response toward Al(III) over a wide concentration range (8.0×10?7–3.0×10?2 M), with a detection limit of 6.0×10?7 M. The potentiometric response of the sensor is independent of the pH of the test solution in the pH range 3.2–4.5. The electrode possesses advantages of very fast response and high selectivity for Al3+ in comparison with alkali, alkaline earth and some heavy metal ions. The sensor was used as an indicator electrode, in the potentiometric titration of aluminum ion and in determination of Al3+ contents in drug, water and waste water samples.  相似文献   

16.
A PVC membrane electrode for copper(II) ion based on a recently synthesized Schiff base as a suitable ion carrier was constructed. The electrode exhibits a Nernstian slope of 28.3 ± 0.6 mV per decade of Cu2+ over a wide concentration range of 7.0 × 10?6‐2.6 × 10?2 M with a detection limit of 5.0 × 10?6M in the pH range of 4.2–5.8. The response time is about 10s and it can be used for at least 1 month without any considerable divergence in potential. It was successfully applied as an indicator electrode in the potentiometric titration of copper ions.  相似文献   

17.
18.
《Electroanalysis》2006,18(11):1091-1096
N‐(2‐Pyridyl)‐N′‐(4‐methoxyphenyl)‐thiourea (PMPT) was found to be a suitable neutral ion carrier for the construction of a highly selective and sensitive La(III) membrane sensor. Poly(vinyl chloride) (PVC) based membranes of PMPT with potassium tetrakis (p‐chlorophenyl) borate (KTpClPB) as an anionic excluder and oleic acid (OA), dibutyl phthalate (DBP), benzyl acetate (BA) and o‐nitrophenyloctyl ether (NPOE) as plasticizing solvent mediators were constructed and investigated as La(III) membrane sensors. A membrane composed of PMPT‐PVC‐KTpClPB‐BA with the ratio 8.0 : 35.0 : 3.0 : 54.0 works well over a very wide concentration range (4.0×10?8 to 1.0×10?1 M) with a Nernstian slope of 19.6±0.2 mV per decade of activity between pH values of 4.0 and 9.0. The detection limit of the sensor was calculated to be 2.0×10?8 M (ca. 3.0 ppb). The sensor displays very good discrimination toward La(III) ions with regard to most common metal ions and lanthanide ions. The proposed sensor shows a short response time for whole concentration range (ca. 12 s). For evaluation of the analytical applicability of the La(III) sensor, it was successfully used as an indicator electrode for the titration of La(III) ions with EDTA. It was also applied to the determination of fluoride content of two mouth wash preparation samples and monitoring of La(III) ions in some binary and ternary mixtures.  相似文献   

19.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on Co(III)-Schiff base [Co(5-NO2- Salen)(PBu3)]ClO4•H2O (where 5-NO2-SalenH=bis(5-nitrosalycilaldehyde)ethylenediamine) as a new carrier for construction of perchlorate-selective electrode by incorporating the membrane ingredients on the surface of a graphite electrodes has been reported. The proposed electrode possesses a very wide Nernestian potential linear range to perchlorate from 1.0×10-6 to 5.0×10-1 mol•L-1 with a slope of (59.4±0.9) mV per decade of perchlorate concentration with a low detection limit of 5.0×10-7 mol•L-1 and good perchlorate selectivity over the wide variety of other anions. The developed electrode has an especially fast response (<5 s) and a wide pH independent range (3.0—12.0) in comparison with recent reported electrodes and can be used for at least 2 months without any considerable divergence in their potential response. This electrode was used for the determination of perchlorate in river water, drinking water, sludgy water and human urine with satisfactory results without complicated and time consuming pretreatment.  相似文献   

20.
The simple PVC‐based membrane containing N,N′,N″,N′′′‐tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane (tpmc) as an ionophore and dibutyl phthalate as a plasticizer, directly coated on a glassy carbon electrode was examined as a new sensor for Cu2+ ions. The potential response was linear within the concentration range of 1.0×10?1–1.0×10?6 M with a Nernstian slope of 28.8 mV/decade and detection limit of 7.0×10?7 M. The electrode was used in aqueous solutions over a wide pH range (1.3–6). The sensor exhibited excellent selectivity for Cu2+ ion over a number of cations and was successfully used in its determination in real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号