 共查询到20条相似文献,搜索用时 359 毫秒
1.
This paper aims to develop thermal model of a vault roof building integrated with earth to air heat exchanger (EAHE). The building under consideration is made of brick vault and adobe (or mud) structures. The methodology adopted for developing thermal model of this building with six interconnected rooms is presented in this paper. The energy balance equations were solved simultaneously using fourth order Runge-Kutta numerical technique. The results from the thermal model were validated using experimental observed data. Experimental results showed that the room air temperature during winter was found 5-15 °C higher as compared to ambient air temperature while lower during summer months. The results show that annual energy saving potential of the building before and after integration of EAHE were 4946 kWh/year and 10321 kWh/year respectively. The seasonal energy efficiency ratio (SEER) for EAHE was determined as 2-3. This considerable increase in annual energy savings potential of building due to EAHE leads to mitigation of CO2 emissions about 16 tons/year and the corresponding annual carbon credit of building was estimated as € 340/year. The life cycle cost (LCC) analysis shows that the payback period is less than 2 years for the investment on EAHE system.  相似文献   

2.
The performance of a high-temperature heat pump unit using geothermal water for heat recovery in buildings is experimentally evaluated. The unit consists of a twin-screw refrigeration compressor, a condenser, an evaporator and an oil cooling system. The effect of the cooled oil temperature on the performance of the heat pump unit is experimentally investigated. Results show that the unit stably produces outlet hot water at a constant temperature of 85 °C and performs well in a wide range of high-temperature conditions with a high energy efficiency ratio. The results also indicate that the key to improving the performance of a high-temperature heat pump unit often depend on the selection of proper cooled oil temperature. The optimum cooled oil temperature is 50-65 °C when the condensing temperature is above 70 °C. At these temperatures, the oil cooling system can increase the energy efficiency ratio of the heat pump by 6.3%.  相似文献   

3.
Shanghai is characteristic of subtropical monsoonal climate with the mean annual temperature of 17.6 °C, and receives annual total radiation above 4470 MJ/m2 with approximately 2000 h of sunshine. A solar energy system capable of heating, cooling, natural ventilation and hot water supply has been built in Shanghai Research Institute of Building Science. The system mainly contains 150 m2 solar collector arrays, two adsorption chillers, floor radiation heating pipes, finned tube heat exchangers and a hot water storage tank of 2.5 m3 in volume. It is used for heating in winter, cooling in summer, natural ventilation in spring and autumn, hot water supply in all the year for 460 m2 building area. The whole system is controlled by an industrial control computer and operates automatically. Under typical weather condition of Shanghai, it is found that the average heating capacity is up to 25.04 kW in winter, the average refrigerating output reaches 15.31 kW in summer and the solar-enhanced natural ventilation air flow rate doubles in transitional seasons. The experimental investigation validated the practical effective operation of the adsorption cooling-based air-conditioning system. After 1-year operation, it is confirmed that the solar system contributes 70% total energy of the involved space for the weather conditions of Shanghai.  相似文献   

4.
洗浴废热能量回收与中水水源热泵应用   总被引:2,自引:0,他引:2  
随着人们生活品质的不断提高,生活洗浴热水所消耗的热能在建筑耗能中的比重不断增加,洗浴废水能量回收的重要性日益凸显。采用中水水源热泵方式回收洗浴废水中的热量要进行合理的技术经济分析,要避免盲目性和节能设备的不合理搭配及滥用。同时,在大型浴室类项目建设的前期,要确定洗浴废水能量回收方案,提前考虑设备机房、浴室结构等土建条件。  相似文献   

5.
Nowadays, modern heat supply technologies are preferred by the decentralized municipal sector because they considerably reduce heat transfer losses. One such solution is a heating system using residential thermal stations (RTS). The advantages of a heating system with RTS, as compared with hot water storage vessels, include stabilizing heat costs, saving energy and a decrease in heat transfer losses.This paper presents the results of an experiment investigating heat consumption in a residential building using RTS. The building, located in Lublin, Poland, was supplied by the local district heating network. The energy consumption was monitored from April 2007 to April 2009. The efficiency of this system was 71.4% during the period when heat was required (winter) and 61.5% during the summer; an annual average efficiency of 67.1%. The energy consumption of the space heating system varied from 0.03 to 0.53 GJ m−2 of the flat's surface area, with the average value being 0.22 GJ m−2. The influences of the location of the flat within the building and the surface area of the flat on the quantity of heat required for space heating were analysed. Specific attention was paid to the occurrence of local heat flows between flats.  相似文献   

6.
The temperature and humidity independent control (THIC) system, which controls indoor temperature and moisture separately, may be an attractive alternative to existing conventional HVAC systems for its prominent improvement on the overall system performance and utilization of low grade energy resources. In order to verify the effectiveness of THIC system, a pilot project has been implemented in an office building in Shenzhen, China. In the system, liquid desiccant fresh air handling units driven by heat pumps are utilized to remove the entire latent load of outdoor air supplied for the whole building, and chilled water at the temperature of 17.5 °C from chiller is pumped and distributed into dry fan coil units and radiant panels to control indoor temperature. This paper presents the results of field test of the system, which shows that the system can provide a comfortable indoor environment even in very hot and humid weather. The COP of the entire THIC system can reach 4.0. According to the energy usage data recorded from the year 2009, the energy consumption of the THIC system in the tested office building was 32.2 kWh/(m2 yr), which demonstrates magnificent energy-saving potential compared with the conventional air-conditioning system (around 49 kWh/(m2 yr)).  相似文献   

7.
In this paper, a simplified mathematical model develops to study round the year effectiveness of photovoltaic/thermal (PV/T) and earth air heat exchanger (EAHE) integrated with a greenhouse, located at IIT Delhi, India. The solar energy application through photovoltaic system and earth air heat exchanger (EAHE) for heating and cooling of a greenhouse is studied with the help of this simplified mathematical model. Calculations are done for four types of weather conditions (a, b, c and d types) in New Delhi, India. The paper compares greenhouse air temperatures when it is operated with photovoltaic/thermal (PV/T) during daytime coupled with earth air heat exchanger (EAHE) at night, with air temperatures when it is operated exclusively with photovoltaic/thermal system (PV/T) and earth air heat exchanger (EAHE), for 24 h. The results reveal that air temperature inside the greenhouse can be increased by around 7-8 °C during winter season, when the system is operated with photovoltaic (PV/T), coupled with earth air heat exchanger (EAHE) at night. From the results, it is seen that the hourly useful thermal energy generated, during daytime and night, when the system is operated with photovoltaic (PV/T) coupled with earth air heat exchanger (EAHE), is 33 MJ and 24.5 MJ, respectively. The yearly thermal energy generated by the system has been calculated to be 24728.8 kWh, while the net electrical energy savings for the year is 805.9 kWh and the annual thermal exergy energy generated is 1006.2 kWh.  相似文献   

8.
Electrically driven heat pumps achieve good efficiencies for space heating. If heat pumps are driven directly by a combustion engine instead of an electric motor, losses attributed to the production and transport of electricity are eliminated. Additionally, the use of the combustion engine's heat leads to a reduced temperature difference across the heat pump. This article presents annual efficiencies of these systems and compares internal combustion engine and electrically driven heat pumps in terms of primary energy consumption and CO2 emissions. Because heat pump performance depends strongly on the heating circuit's flow temperature level, the comparison is performed for air-to-water and geothermal heat pump systems in two cases of maximum flow temperatures (40 °C and 60 °C). These temperature levels represent typical modern buildings with large heating surfaces and older buildings with high-temperature radiators, respectively. In addition to the different heat pump setups, conventional space heating systems are included in the comparison. The calculations show that natural gas-driven heat pumps achieve about the same efficiency and CO2 emissions as electrically driven heat pumps powered with electricity from the most modern natural gas-fired combined cycle power plants. The efficiency of such systems is about twice that of conventional boiler technologies.  相似文献   

9.
The Eawag's new headquarters “Forum Chriesbach” is an exemplary illustration of a ‘sustainable’ construction design for office buildings. With a unique combination of architectural and technical elements the building reaches a very low 88 kWh/m2 overall primary energy consumption, which is significantly lower than the Swiss Passive House standard, Minergie-P. A monitoring and evaluation project shows that the building is heated mainly by using the sun and internal heat gains from lighting, electrical appliances and occupants, resulting in an extremely low space heating demand. Cooling is provided by natural night time ventilation and the earth-coupled air intake, which pre-cools supply air and provides free cooling for computer servers. However, values for embodied energy and electricity consumption remain significant, even with partial on-site electricity production using photovoltaics. TRNSYS computer simulations show the contributions of individual building services to the overall energy balance and indicate that the building is resilient towards changes in parameters such as climate or occupancy density. Measurements confirm comfortable room temperatures below 26 °C, even during an extremely hot summer period, and 20-23 °C in the winter season. An economic analysis reveals additional costs of only 5% compared to a conventionally constructed building and a payback-time of 13 years.  相似文献   

10.
This is the first research paper on data center from Finland. The objectives of this study are to evaluate air management and energy performance of cooling system and investigate the possibilities of energy saving and reuse in the data center. Field measurements, particularly for long term's IT and facility powers, were conducted. Different performance metrics for the cooling system and power consumption were examined and analysed. Key problem areas and energy saving opportunities were identified. The electrical end use breakdown was estimated. Results show that IT equipment intake conditions were within the recommended or allowable ranges from ASHRAE. The Power Usage Effectiveness (PUE) value for a typical year was about 1.33. Noticeable recirculation of hot air was not observed, but extreme bypass air was found. The air change rate was set much bigger than the recommended ASHRAE's value. There was no heat recovery system. The air management and heat recovery issues therefore need to be addressed. Fan speeds (Computer Room Air-Conditioning Unit) should be reduced and the ventilation rate should be minimized. Further, a simulated heat recovery system was presented demonstrating that the data center could potentially provide yearly space and hot water heating for 30,916 m2 non-domestic building.  相似文献   

11.
Donata Dubber  N.F. Gray 《Water research》2009,43(14):3443-3452
A new approach to the enumeration of ciliate protozoa in activated sludge is described. A 25 μL sub-sample volume is optimal for routine analysis using a standard slide and 24 × 24 mm cover slip requiring between 20 and 40 min per sub-sample for full enumeration and identification of species. However, to achieve high probability (≥95%) of recovering all species large numbers of replicates are required (i.e. 23-47). To achieve high probabilities of recovery using less replicates it is necessary to neglect rare species with low densities (<0.5%); based on the assumption that they do not play a significant role in plant performance. The precise number of replicates required for different probabilities of recovering species is determined by conducting an initial pilot survey analysing a minimum of 8 replicates and using a probability equation to determine the optimum replicate number for that particular plant. Six replicate 25 μL sub-samples provided excellent species recovery (90-95% excluding up to 3 rare species), while analysing just two or three replicates, as commonly used in previous wastewater studies, only gave probabilities of 25 and 50% respectively for the same recovery. Ciliate analysis should be completed within 8 h of collection with significant changes in community structure occurring beyond this period.  相似文献   

12.
本文介绍并分析了空调冷凝热回收和回路控制方法及热水器的设计结构和应用。  相似文献   

13.
This article presents a simulation study comparing the primary energy and comfort performance of ventilation assisted thermo-active building systems (TABS) relative to a conventional all-air (VAV) system in a compact office building featuring good thermal envelope performance, heat recovery, and solar gain control for the continental climate of Omaha, Nebraska with pronounced heating and cooling periods. TABS heating is accomplished using a geothermal heat pump and TABS cooling using a geothermal heat exchanger without an additional vapor compression cycle required. It was found that the coordination of the TABS and VAV systems is crucial, i.e., supply air temperature and active layer temperature setpoints and reset schedules greatly affect the performance of the overall system. The small contribution of TABS in the heating case shows the need for the adaptation of the ventilation system configuration to the TABS system. Annual cooling energy demand for the ventilation assisted TABS is higher than for the pure VAV system, which is due to lower occupied period room operative temperatures and thus a higher comfort provided. While a 4% useful energy penalty for the combined TABS/VAV was recorded, the VAV case requires 20% more delivered energy than the TABS case because of the displacement of compressor driven coil loads with low-exergy cooling through the ground heat exchanger in the TABS case. A primary energy intensity of 189 kWh/m2 a was recorded for the TABS case; in contrast, the conventional all-air (VAV) equipped building incurs a primary energy intensity of 229 kWh/m2a, which represents a penalty of 20%. Clear advantages of the TABS approach can be observed with respect to thermal comfort: during summer cooling periods, the mean radiant temperature of the TABS case is on average 2 K below that of the VAV case. Moreover, the VAV system is associated with a fairly constant predicted mean vote (PMV) value of 0.75, which is quite warm, while the TABS equipped system reveals an average of 0.56, which results in only 12% instead of 17% of people dissatisfied. Based on these results, ventilation assisted thermo-active cooling systems appear to be a very promising alternative to conventional all-air systems offering both significant primary energy as well as thermal comfort advantages provided the TABS is mated with low-exergy heating and cooling sources.  相似文献   

14.
Benchmarking is an important step in implementing energy conservation in a semiconductor fabrication plant (hereafter referred to as “fab”). A semiconductor cleanroom facility system is complicated, usually comprised of several sub-systems, such as a chilled water system, a make-up system, an exhaust air system, a compressed air system, a process cooling water (PCW) system, a nitrogen system, a vacuum system, and an ultra-pure water (UPW) system. It is a daunting task to allocate energy consumption and determine an optimum benchmark. This study aims to establish the energy benchmark of a typical 8-in. DRAM semiconductor fab through field measurement data. Results of the measured energy consumption index were: chilled water system (including chiller, chilled water pump and cooling tower): 0.257 kW/kW (=0.9 kW/RT) in summer and 0.245 kW/kW (=0.86 kW/RT) in winter air recirculation air system: 0.00018 kWh/m3 make-up air system: 0.0042 kWh/m3 general exhaust air system: 0.0007 kWh/m3 solvent exhaust air system: 0.0021 kWh/m3 acid exhaust air system: 0.0009 kWh/m3 alkaline exhaust air system: 0.0025 kWh/m3 nitrogen system: 0.2209 kWh/m3 compressed dry air system: 0.2250 kWh/m3 process cooling water system: 1.3535 kWh/m3 and ultra-pure water system: 9.5502 kWh/m3. These data can be used to assess the efficiency of different energy-saving schemes and as a good reference for factory authorities. The PCW system's status before and after implementing energy conservation is discussed.  相似文献   

15.
This paper presents the performance evaluation of a hybrid photovoltaic thermal (Semi transparent PVT) double pass facade for space heating. The thermal model has been developed by using the energy balance equations of the proposed hybrid photovoltaic thermal double pass facade under quasi-steady state condition. Numerical computations have been carried out for the composite climate of New Delhi, India. An analysis has been carried out to calculate annual energy and exergy gain for the hybrid photovoltaic thermal double pass facade. On the basis of numerical results it has been observed that the annual thermal and electrical energy are 480.81 kWh and 469.87 kWh respectively. The yearly overall thermal energy generated by the system has been calculated as 1729.84 kWh. It is also observed that the room air temperature increases by 5-6 °C than the ambient air temperature for a typical winter day.  相似文献   

16.
This paper investigates energy conservation, mitigation of CO2 emissions and economics of retrofitting for a honey storage building with Trombe wall for winter heating application. The passive heating potential of Trombe wall for a honey storage building was estimated using TRNSYS building simulation software. This honey storage building is located at Gwalior (latitude: 26°14′N) in India. During winter months, the room air temperature of building falls below the required temperature range of 18–27 °C which is suitable for honey storage. So, the room air temperature range is maintained in the building using a 2.3 kW capacity electrical oil filled radiator (or room air heater) which accounts for the major energy consumption of the building on an annual basis. On account of which there are significant CO2 emissions into the atmosphere from the honey storage building. Hence, this case study was conducted to recommend the passive heating concept to the stakeholders of the building so as to conserve the energy requirement for room air heating. The investigation showed that the room air temperature can be easily maintained in the range suitable for honey storage using a vented Trombe wall. The experimental work was carried out for the existing building on a typical clear day of harsh winter month of January to validate the results of TRNSYS model of the present building. The statistical error analysis showed a good agreement between model and experimental results. This investigation concludes that there is potential of energy conservation up to 3312 kWh/year and associated reduction in CO2 emissions (∼33 tonne/year) using a Trombe wall. Also, the retrofitting of building is economically viable as the simple payback period is only about 7 months.  相似文献   

17.
Environmental protection measures are conducted directly by the use of renewable energy sources. The energy development of cities in Europe is aimed at the sustainable use of renewable energy sources in order to achieve the substitution of fossil fuels and the reduction of the hazardous gas emission into the atmosphere. Geothermal resources of medium and low enthalpy in Europe being used for obtaining heat energy are providing about 6600 MWt, currently having the growth trend of 50 MWt annually. The use of geothermal low enthalpy, namely of subgeothermal groundwater resources, has even higher annual growth rate, and if such a trend is kept till the year 2010, the produced energy will amount about 8000 MWt. Criteria of the groundwater use as a hydrogeothermal energy resource in heat pumps are complex, and they deal with aspects of incoming temperatures and groundwater quantities. The precise limit temperature of groundwater that would separate the direct use of geothermal energy (only by the use of heat exchangers), and indirectly by the use of a heat pump has not been determined in the professional and scientific practice of Serbia so far. Taking into account that relatively small number of new flat is being built in Serbia nowadays, if we want to save energy it is necessary to carry out the energy reconstruction of the existing flats whose number is estimated to be more than 2.8 million. By the application of subgeothermal energy and the use of heat pumps, energy consumption would be significantly reduced.  相似文献   

18.
Taipei City, located in the subtropical zone, has a basin landform. The summer is always hot and humid and the air temperature right after sunset is typically higher than 30 °C. Heat rejection from residential buildings in urban area, equipped with lots of the window type air conditioners, not only increases the air temperature outside, but also burdens the cooling load. Based on the time schedule of air conditioner use of Taipei citizens, the heat rejection/building energy use and the air temperature distribution were evaluated, and finally the additional electric consumption of air conditioners was predicted. Two software, EnergyPlus (building energy program) and Windperfect (CFD, computational fluid dynamics software) were employed in this study. In the CFD simulation, the geometry of buildings that covers 700 m in diameter was created with GIS (geographical information system) and the total mesh number was more than 3 millions. Three specified temperatures (Tam, Tbu and Tac) were used to describe the temperature distribution within the urban canopy by hourly time variation and spatial distribution with height and horizontal profile. The results revealed that the temperature gradually increased with height and the temperature next to the buildings was always higher than the ambient air. The feedback (penalty) of heat rejection to cooling load was found 10.7% during 19:01 to 02:00 h on the following day.  相似文献   

19.
The heat pump for simultaneous heating and cooling (HPS) carries out space heating, space cooling and hot water production for small office and residential buildings. It works under heating, cooling and simultaneous modes to produce hot and chilled water according to the thermal demand of the building. A subcooler connected to a water tank is placed after the condenser to recover some energy by subcooling of the refrigerant during a heating mode. The water loop at a higher temperature than ambient air is used subsequently as a source for a water evaporator. Average winter performance is improved compared to a standard reversible heat pump (HP). The air evaporator is defrosted by a two-phase thermosiphon without stopping the heat production. The operation of the HPS is modelled using TRNSYS software. The model is validated using results of an experimental study carried out on a HPS prototype working with R407C. Annual simulations of the HPS coupled to a hotel are run in order to evaluate annual performance and energy consumption of the system. The results are compared to the ones of a standard reversible HP. Depending on the scenario, savings in electric energy consumption and annual performance improvement can reach respectively 55% and 19%.  相似文献   

20.
Energy performance of non-residential buildings and in particular of office buildings used as bank branches is very limited. This paper presents new data from 39 representative bank branches and results from a more in-depth analysis of information from energy audits in 11 typical bank branches throughout Greece. The data was used to derive practical energy benchmarks and assess various energy conservation measures. Accordingly, the average annual total energy consumption is 345 kWh/m2. The breakdown of the different end-uses reveals that HVAC averages 48% of the final energy consumption, lighting averages 35% and other office and electronic equipment average 17%. The most effective energy conservation measures reach annual energy savings of 56 kWh/m2 by regulating the indoor set point temperature, while the use of HF electronic ballasts and CFL lamps may save about 22 kWh/m2 and 29 kWh/m2 with and without the use of the external marquee sign, respectively.  相似文献   