首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We present boron isotope and concentration data from magmatic (komatiitic to rhyolitic) and sedimentary geological silicate and artificial glass reference materials that cover a wide spectrum of boron isotope compositions and boron concentrations. Boron isotope compositions were determined by TIMS (Cs2BO2+ -graphite and BO2- method) and boron concentrations by ICP-AES. Boron concentrations ranged from 7 to 159μ g-1 and agree within 14% with published values. Based on replicate analyses of individually prepared sample aliquots an overall external reproducibility of better than 10% was determined. The obtained δ11B values ranged from -12.6 to +13.6% and were reproducible within 1.1 % (2 RSD; excluding NTIMS) on the basis of individually prepared sample aliquots. The δ11B values of JA-1 (+5.3%), JB-3 (+5.9%) and JR-2 (+2.9%) overlap the published data within analytical uncertainty. For the first time δ11B values for the TB (-12.6%) and the MPI-DING glasses GOR-128-G (+13.6%), GOR-132-G (+7.1 %) and StHs6/80-G (-4.5%) are reported. The δ11B values obtained by the Cs2BO2+ -graphite and the BO2- method as well as the majority of δ11B values obtained using different sample preparation methods agree within analytical uncertainty. Therefore, we conclude that none of these analytical methods introduce any systematic error on the obtained δ11B values.  相似文献   

2.
Chromium (Cr) isotopes have been widely used in various fields of Earth and planetary sciences. However, high‐precision measurements of Cr stable isotope ratios are still challenged by difficulties in purifying Cr and organic matter interference from resin using double‐spike thermal ionisation mass spectrometry. In this study, an improved and easily operated two‐column chemical separation procedure using AG50W‐X12 (200–400 mesh) resin is introduced. This resin has a higher cross‐linking density than AG50W‐X8, and this higher density generates better separation efficiency and higher saturation. Organic matter from the resin is a common cause of inhibition of the emission of Cr during analysis by TIMS. Here, perchloric and nitric acids were utilised to eliminate organic matter interference. The Cr isotope ratios of samples with lower Cr contents could be measured precisely by TIMS. The long‐term intermediate measurement precision of δ53/52CrNIST SRM 979 for BHVO‐2 is better than ± 0.031‰ (2s) over one year. Replicated digestions and measurements of geological reference materials (OKUM, MUH‐1, JP‐1, BHVO‐1, BHVO‐2, AGV‐2 and GSP‐2) yield δ53/52CrNIST SRM 979 results ranging from ?0.129‰ to ?0.032‰. The Cr isotope ratios of geological reference materials are consistent with the δ53/52CrNIST SRM 979 values reported by previous studies, and the measurement uncertainty (± 0.031‰, 2s) is significantly improved.  相似文献   

3.
The Istituto di Geoscienze e Georisorse (IGG), on behalf and with the support of the International Atomic Energy Agency (IAEA), prepared eight geological materials (three natural waters and five rocks and minerals), intended for a blind interlaboratory comparison of measurements of boron isotopic composition and concentration. The materials were distributed to twenty seven laboratories - virtually all those performing geochemical boron isotope analyses in the world -which agreed to participate in the intercomparison exercise. Only fifteen laboratories, however, ultimately submitted the isotopic and/or concentration results they obtained on the intercomparison materials. The results demonstrate that interlaboratory reproducibility is not well reflected by the precision values reported by the individual laboratories and this observation holds true for both boron concentration and isotopic composition. The reasons for the discrepancies include fractionations due to the chemical matrix of materials, relative shift of the zero position on the δ11B scale and a lack of well characterized materials for calibrating absolute boron content measurements. The intercomparison materials are now available at the IAEA (solid materials) and IGG (waters) for future distribution.  相似文献   

4.
This work presents new 87Sr/86Sr and δ88/86SrSRM987 isotopic values of thirteen mineral, vegetal and animal reference materials. Except for UB‐N, all our results are consistent with previously published data. Our results highlight intermediate precisions among the best presently published and a non‐significant systematic shift with the calculated δ88/86SrSRM987 mean values for the three most analysed reference materials in the literature (i.e., IAPSO, BCR‐2 and JCp‐1). By comparison with the literature and between two distinct digestions, a significant bias of δ88/86SrSRM987 values was highlighted for two reference materials (UB‐N and GS‐N). It has also been shown that digestion protocols (nitric and multi‐acid) have a moderate impact on the δ88/86SrSRM987 isotopic values for the Jls‐1 reference materials suggesting that a nitric acid digestion of carbonate can be used without significant bias from partial digestion of non‐carbonate impurities. Different δ88/86SrSRM987 values were measured after two independent Sr/matrix separations, according to the same protocol, for a fat‐rich organic reference material (BCR‐380R) and have been related to a potential post‐digestion heterogeneity. Finally, the δ88/86SrSRM987 value differences measured between animal‐vegetal and between coral‐seawater reference materials agree with the previously published results, highlighting an Sr isotopic fractionation along the trophic chain and during carbonate precipitation.  相似文献   

5.
This paper presents an adapted anion exchange column chemistry protocol which allowed separation of high-purity fractions of Cu and Zn from geological materials. Isobaric and non-spectral interferences were virtually eliminated for consequent multiple-collector ICP-MS analysis of the isotopic composition of these metals. The procedure achieved ∼ 100% recoveries, thus ensuring the absence of column-induced isotopic fractionation. By employing these techniques, we report isotopic analyses for Cu and Zn from five geological reference materials: BCR-027 blende ore (BCR), δ65Cu = 0.52 ± 0.15‰ (n = 10) and δ66Zn = 0.33 ± 0.07‰ (n = 8); BCR-030 calcined calamine ore (BCR), δ66Zn = -0.06 ± 0.09‰ (n = 8); BCR-1 basalt (USGS), δ66Zn = 0.29 ± 0.12‰ (n = 8); NOD-P-1 manganese nodule (USGS), δ65Cu = 0.46 ± 0.08‰ (n = 10) and δ66Zn = 0.78 ± 0.09‰ (n = 9); SU-1 Cu-Co ore (CCRMP), δ65Cu = -0.018 ± 0.08‰ (n = 10) and δ66Zn = 0.13 ± 0.17‰ (n = 6). All uncertainties are ± 2s; copper isotope ratios are reported relative to NIST SRM-976, and zinc isotope ratios relative to the Lyon-group Johnson Matthey metal (batch 3-0749 L) solution, JMC Zn. These values agree well with the limited data previously published, and with results reported for similar natural sample types. Samples were measured using a GVi IsoProbe MC-ICP-MS, based at the Natural History Museum, London. Long-term measurement reproducibility has been assessed by repeat analyses of both single element and complex matrix samples, and was commonly better than ± 0.07‰ for both δ66Zn and δ65Cu.  相似文献   

6.
The advent of multiple collector-inductively coupled plasma-mass spectrometry has provided an impetus to the study of isotope abundance variations in natural materials. In particular, the study of "non-traditional" stable isotopes has revealed isotope fractionation variations caused by a range of physiochemical and biological mechanisms. The magnitude of these variations may be < 1 per mil per mass unit, but are significant in terms of the experimental uncertainties involved, provided rigorous mass spectrometric protocols are followed. The double spike technique can be used effectively to evaluate isotope fractionation effects for both multiple collector-inductively coupled plasma-mass spectrometry and thermal ionisation mass spectrometry. The demanding nature of this research implies the need for internationally-accepted reference materials so that interlaboratory comparisons can be made with confidence. At present, isotopically certified reference materials are unavailable for many elements, including Cu, Zn, Mo and Cd, and it is important that this situation be rectified as soon as practicable. Until such time as isotopically certified reference materials become available for every element, stable isotope geochemists should adopt a common reference material as the standard for each element so that rigorous interlaboratory comparisons can be made.  相似文献   

7.
In 1999 the Istituto di Geoscienze e Georisorse (IGG), with the support of the International Atomic Energy Agency (IAEA), undertook the collection, preparation and distribution of eight geological materials intended for a blind interlaboratory comparison of measurements of boron isotopic composition and concentration. The materials came from Italian sources and consist of three natural waters (Mediterranean seawater and two groundwaters) and five rocks and minerals (tourmaline, basalt, obsidian, limestone and clay). The solid materials were crushed, milled and mixed, in preparation for distribution. Extensive assays performed at the IGG on these materials demonstrated that their boron isotopic and chemical compositions are homogeneous.
Additional homogeneity tests were carried out on solid material fragments at the GeoForschungsZentrum Potsdam, with the specific objective of investigating the suitability of some of them for the calibration in situ of micro-analytical techniques. Two materials, B4 (tourmaline) and B6 (obsidian), proved to be isotopically homogeneous and may become excellent references for in situ microanalyses of boron isotopes.
The materials described here were used as the basis of a major laboratory intercomparison study and are now available for further distribution from either the IAEA (solid materials) or the IGG (waters).  相似文献   

8.
This contribution presents data for laser ablation multicollector ICP‐MS (LA‐MC‐ICP‐MS) analyses of NIST SRM 610 and 612 glasses with the express purpose of examining the Pb isotope homogeneity of these glasses at the ~ 100 μm spatial scale, relevant to in situ analysis. Investigation of homogeneity at these scales is important as these glasses are widely used as calibrators for in situ measurements of Pb isotope composition. Results showed that at the levels of analytical uncertainty obtained, there was no discernable heterogeneity in Pb isotope composition of NIST SRM 610 and also most probably for NIST SRM 612. Traverses across the ~ 1.5 mm glass wafers supplied by NIST, consisting of between 75 and 133 individual measurements, showed no compositional outliers at the two standard deviation level beyond those expected from population statistics. Overall, the measured Pb isotope ratios from individual traverses across NIST SRM 610 and 612 wafers closely approximate single normally‐distributed populations, with standard deviations similar to the average internal uncertainty for individual measurement blocks. Further, Pb isotope ratios do not correlate with Tl/Pb ratios measured during the analysis, suggesting that regions of volatile element depletion (marked by low Tl/Pb) in these glasses are not associated with changes in Pb isotope composition. For NIST SRM 610 there also appeared to be no variation in Pb isotope composition related to incomplete mixing of glass base and trace element spike during manufacture. For NIST SRM 612 there was some dispersion of measured ratios, including some in a direction parallel to the expected mixing line for base‐spike mixing. However, there was no significant correlation parallel to the mixing line. At this time this cannot be unequivocally demonstrated to result from glass heterogeneity, but it is suggested that NIST SRM 610 be preferred for standardising in situ Pb isotope measurements. Data from this study also showed significantly better accuracy and somewhat better precision for ratios corrected for mass bias by external normalisation to Pb isotope ratios measured in bracketing calibrators compared to mass bias corrected via internal normalisation to measured 205Tl/203Tl, although the Tl isotopic composition of both glasses appears to be homogeneous.  相似文献   

9.
Calcium isotopic compositions of sixteen Ca‐bearing USGS geological reference materials including igneous and sedimentary rocks are reported. Calcium isotopic compositions were determined in two laboratories (GPMR, State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan; and CIG, Centre for Isotope Geochemistry, University of California, Berkeley) using the 42Ca‐48Ca double‐spike technique by thermal ionisation mass spectrometry. As opposed to common cation exchange resin, a micro‐column filled with Ca‐selective resin (DGA resin) was used in order to achieve high recovery (> 96%) and efficient separation of Ca from the sample matrix. The intermediate measurement precision was evaluated at 0.14‰ (2s) for δ44/40CaSRM915a at GPMR, based on replicate measurements of pure Ca reference material NIST SRM 915a, NIST SRM 915b and seawater. Overall, the measurement uncertainties in both laboratories were better than 0.15‰ at the 2s level. Result validation was carried out for all available data sets. The Ca isotopic compositions of USGS reference materials are not only in agreement between GPMR and CIG, but also in agreement with previously published data within quoted uncertainties. The comprehensive data set reported in this study serves as a reference for both quality assurance and interlaboratory comparison of high precision Ca isotopic study.  相似文献   

10.
河水样品中硼的分离及其同位素组成测定   总被引:1,自引:0,他引:1  
对河水样品中低含量硼的分离方法及硼同位素组成的测定进行了研究。将约1000mL河水样品分别用硼特效树脂,混合树脂富集和纯化后,紫外灯照射去除有机质,蒸发浓缩至小体积,采用正热离子质谱法进行硼同位素组成的测定。全流程回收率在95%以上,同位素稀释法测得全流程空白为41ng。经该方法处理后的样品能满足同位素质谱测定的需要。不产生同位素分馏,测试精度基本在0.6‰以内。  相似文献   

11.
The interest in the study of gallium (Ga) stable isotope fractionation in low‐ and high‐temperature environments has increased significantly in the last few years. However, a unified reference material (RM) is still lacking for the Ga isotope research community, which hinders interlaboratory comparison between different groups. Consequently, certification of Ga isotopic reference materials for interlaboratory comparison is of high priority. In this study, Ga isotope ratio data for ten geological RMs including silicates, shales and ferromanganese nodules, and two pure Ga RMs including NIST SRM 994 and NIST SRM 3119a reported by three different groups, were determined by MC‐ICP‐MS. Sample matrices of geological RMs were separated by a two‐column separation method with the use of AG MP‐1M and AG 50‐X8 resin, separately, and quantitative recoveries of > 99% Ga were obtained for all geological RMs. Instrumental mass bias was corrected by the combined calibrator‐sample bracketing and internal normalisation model. Validation of the proposed method was performed by analysing synthetic solutions. After normalisation of all available δ71Ga data of geological RMs to a single Ga RM, results obtained in our study are in agreement with previously reported results.  相似文献   

12.
Magnesium isotopic compositions are reported for twenty‐four international geological reference materials including igneous, metamorphic and sedimentary rocks, as well as phlogopite and serpentine minerals. The long‐term reproducibility of Mg isotopic determination, based on 4‐year analyses of olivine and seawater samples, was ≤ 0.07‰ (2s) for δ26Mg and ≤ 0.05‰ (2s) for δ25Mg. Accuracy was tested by analysis of synthetic reference materials down to the quoted long‐term reproducibility. This comprehensive dataset, plus seawater data produced in the same laboratory, serves as a reference for quality assurance and inter‐laboratory comparison of high‐precision Mg isotopic data.  相似文献   

13.
The concentration of boron was determined in twenty one geochemical reference materials (silicate rocks) by isotope dilution inductively coupled plasma-mass spectrometry. Boron was extracted from the rocks using HF digestion, suppressing boron volatilisation through boron-mannitol complexation. Sample solutions, in a diluted HCl matrix, were analysed by ICP-MS without any separation of boron from the matrix elements. The results obtained were in agreement with the literature data and indicate that using the described procedure, trace amounts of boron can be very easily determined in complex matrices with rapidity and precision. With the instrumentation and reagents used in this study, this procedure can be used for the determination of 0.5 μg g−1 boron in a 15 0 mg silicate rock sample. Replicate analyses of the twenty one geochemical reference materials (GRM), ranging in boron concentration from 1.35 to 15 7 μg g−1, yielded precisions (relative standard deviation) varying between 0.9 and 9.8%.  相似文献   

14.
In this study, the Cd isotopic composition of various geological reference materials and anthropogenic samples was investigated. The measurements were made by multicollector ICP-MS and instrumental mass fractionation was controlled using a "sample-standard bracketing" technique. Cadmium isotopic data are reported relative to an internal Cd solution (Cd Spex) and expressed as the 114 Cd/110Cd delta value. Two other Cd solutions (Prolabo and JMC) were analysed and yielded the same 0% delta value. A fractionated Cd metal sample (Münster Cd) was used as a secondary reference material for Cd isotopic measurements and we obtained a 114 Cd/110 Cd delta value of 4.48% relative to Cd Spex solution. As opposed to multi-stage Cd purification previously published in the literature, a new one step anionic exchange purification using dilute HCl for the analysis of Cd isotopes in geological samples was developed. This method enabled a high recovery (> 95%) and effective separation of the sample matrix to be achieved. The long-term external reproducibility was evaluated at 0.12% (2 standard deviations) for the 114 Cd/110Cd ratio, based on reference solutions and replicated measurements of samples over one year. The variation of Cd isotopic composition of natural terrestrial samples is restricted to a small range of 0.4%, which is similar to previously reported results. In contrast, large variations of Cd isotopic composition were found for anthropogenic samples with values as low as −0.64% for a dust sample issued from a lead smelter and values as high as +0.50% for NIST SRM 2711 (metal-rich soil). These variations are 10 times larger than the reproducibility and suggest that Cd isotopes can be useful as tracers of anthropogenic sources of Cd in the environment.  相似文献   

15.
In this study the homogeneity of the zinc isotopic composition in the NIST SRM 683 reference material was examined by measuring the Zn isotopic signature in microdrilled sample powders from two metal nuggets. Zinc was purified using AG MP‐1M resin and then measured by MC‐ICP‐MS. Instrumental mass bias was corrected using the “sample‐standard bracketing” method and empirical external normalisation with Cu doping. After evaluating the potential effects of varying acid mass fractions and different matrices, high‐precision Zn isotope data were obtained with an intermediate measurement precision better than ± 0.05‰ (δ66Zn, 2s) over a period of 5 months. The δ66ZnJMC‐Lyon mean values of eighty‐four and fourteen drilled powders from two nuggets were 0.11 ± 0.02‰ and 0.12 ± 0.02‰, respectively, indicating that NIST SRM 683 is a good isotopic reference material with homogeneous Zn isotopes. The Zn isotopic compositions of seventeen rock reference materials were also determined, and their δ66Zn values were in agreement with most previously published data within 2s. The δ66Zn values of most of the rock reference materials analysed were in the range 0.22–0.36‰, except for GSP‐2 (1.07 ± 0.06‰, n = 12), NOD‐A‐1 (0.96 ± 0.03‰, = 6) and NOD‐P‐1 (0.78 ± 0.03‰, = 6). These comprehensive data should serve as reference values for quality assurance and interlaboratory calibration exercises.  相似文献   

16.
The interest in variations of barium (Ba) stable isotope amount ratios in low and high temperature environments has increased over the past several years. Characterisation of Ba isotope ratios of widely available reference materials is now required to validate analytical procedures and to allow comparison of data obtained by different laboratories. We present new Ba isotope amount ratio data for twelve geological reference materials with silicate (AGV‐1, G‐2, BHVO‐1, QLO‐1, BIR‐1, JG‐1a, JB‐1a, JR‐1 and JA‐1), carbonate (IAEA‐CO‐9) and sulfate matrices (IAEA‐SO‐5 and IAEA‐SO‐6) relative to NIST SRM 3104a. In addition, two artificially fractionated in‐house reference materials BaBe12 and BaBe27 (δ137/134Ba = ?1.161 ± 0.049‰ and ?0.616 ± 0.050‰, respectively) are used as quality control solutions for the negative δ‐range. Accuracy of our data was assessed by interlaboratory comparison between the University of Bern and the United States Geological Survey (USGS). Data were measured by MC‐ICP‐MS (Bern) and TIMS (USGS) using two different double spikes for mass bias correction (130Ba–135Ba and 132Ba–136Ba, respectively). MC‐ICP‐MS measurements were further tested for isobaric and non‐spectral matrix effects by a number of common matrix elements. The results are in excellent agreement and suggest data accuracy.  相似文献   

17.
An analytical artefact is reported here related to differences in instrumental mass fractionation between NIST SRM glasses and natural geological glasses during SIMS boron isotope determinations. The data presented demonstrated an average 3.4‰ difference between the NIST glasses and natural basaltic to rhyolitic glasses mainly in terms of their sputtering-induced fractionation of boron isotopes. As no matrix effect was found among basaltic to rhyolitic glasses, instrumental mass fractionation of most natural glass samples can be corrected by using appropriate glass reference materials. In order to confirm the existence of the compositionally induced variations in boron SIMS instrumental mass bias, the observed offset in SIMS instrumental mass bias has been independently reproduced in two laboratories and the phenomenon has been found to be stable over a period of more than one year. This study highlights the need for a close match between the chemical composition of the reference material and the samples being investigated.  相似文献   

18.
Geochemical studies of geological samples require the precise determination of their major and trace element contents and, when measured, of their isotopic compositions. It is now commonly accepted that the accuracy and precision of geochemical analyses are best estimated by the concomitant analysis of international reference materials run as unknown samples. Although the composition of a wide selection of basalts is relatively well constrained, this is far from being the case for sedimentary materials. We present here a comprehensive set of major and trace element data as well as Nd, Hf, Sr and Pb isotopic compositions for thirteen commonly used international reference materials – eight magmatic rocks (BHVO‐2, BR, BE‐N, BR 24, AGV‐1, BIR‐1, UB‐N, RGM‐1) and five sediments (JLk‐1, JSd‐1, JSd‐2, JSd‐3, LKSD‐1). We determined the concentrations of over forty elements in the magmatic rocks together with Sr, Nd, Hf and Pb isotopic compositions. Our trace element results were both accurate (difference ≤ 3%) and precise (reproducibility at 1s ≤ 3%) and the isotopic results were very similar to other published values. In contrast, we observed a significant chemical and isotopic variability in the sedimentary materials, which we attribute to mineral heterogeneities in the powders. Despite the limitation imposed by this heterogeneity, our work presents a complete set of data determined with a precision not yet achieved in the literature for sedimentary material. We also provide the first Nd, Hf and Pb isotopic measurements for the five sediments, which are commonly used by the geochemical community. Our study of both basalt and sediment reference materials represents a comprehensive and self‐consistent set of geochemical data and can therefore be considered as a reference database for the community.  相似文献   

19.
The boron isotopic ratio of 11B/10B (δ11BSRM951) and trace element composition of marine carbonates are key proxies for understanding carbon cycling (pH) and palaeoceanographic change. However, method validation and comparability of results between laboratories requires carbonate reference materials. Here, we report results of an inter‐laboratory comparison study to both assign δ11BSRM951 and trace element compositions to new synthetic marine carbonate reference materials (RMs), NIST RM 8301 (Coral) and NIST RM 8301 (Foram) and to assess the variance of data among laboratories. Non‐certified reference values and expanded 95% uncertainties for δ11BSRM951 in NIST RM 8301 (Coral) (+24.17‰ ± 0.18‰) and NIST RM 8301 (Foram) (+14.51‰ ± 0.17‰) solutions were assigned by consensus approach using inter‐laboratory data. Differences reported among laboratories were considerably smaller than some previous inter‐laboratory comparisons, yet discrepancies could still lead to large differences in calculated seawater pH. Similarly, variability in reported trace element information among laboratories (e.g., Mg/Ca ± 5% RSD) was often greater than within a single laboratory (e.g., Mg/Ca < 2%). Such differences potentially alter proxy‐reconstructed seawater temperature by more than 2 °C. These now well‐characterised solutions are useful reference materials to help the palaeoceanographic community build a comprehensive view of past ocean changes.  相似文献   

20.
The lithium isotope system can be an important tracer for various geological processes, especially tracing continental weathering. The key to this application is the accurate and precise determination of lithium isotopic composition. However, some of the previously established column separation methods are not well behaved when applied to chemically diverse materials, due to the significant variations in matrix/lithium ratios in some materials. Here, we report a new dual‐column system for lithium purification to achieve accurate and precise analysis of lithium isotopic compositions using a multi‐collector inductively coupled plasma‐mass spectrometer (MC‐ICP‐MS). Compared with single‐column systems, our dual‐column system yielded a consistent elution range of the lithium‐bearing fraction (7–16 ml) for samples with a large range of lithium loads and matrix compositions, so that column re‐calibration is not required. In addition, this method achieved complete lithium recovery and low matrix interference (e.g., Na/Li ≤ 1) with a short elution time (~ 6 h, excluding evaporation), with the entire procedure completed in 1.5 days. We report high precision Li isotopic compositions in twelve chemically diverse materials including seawater, silicates, carbonates, manganese nodules and clays. New recommended Li isotopic values and associated uncertainties are presented as reference values for quality control and inter‐laboratory calibration for future research and were consistent with previously published data. However, significant lithium isotopic variances (~ 1‰) in BHVO‐2 from different batches suggest Li isotopic heterogeneity in this reference material and that Li isotopic studies using this reference material should be treated with caution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号