首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A pilot-plant study was designed to compare the effectiveness of microfiltration (MF) and ultrafiltration (UF) as pretreatment for high-pressure membranes in reclamation of biologically treated wastewater effluent. Granular media, filtered secondary effluent from a full-scale wastewater treatment plant, was fed to MF and UF units that operated in parallel. Each of these filtrates served as the feedwater to two reverse osmosis (RO) units and one nanofiltration (NF) unit that operated in parallel. The decline in specific flux was substantially lower for high-pressure membranes receiving UF than MF pretreatment over the course of each of four pilot plant runs that lasted from 1 to 7 weeks. The removal of organic matter as measured by dissolved organic carbon (DOC) was somewhat higher by UF than MF pretreatment (about 15% by UF compared with 11% by MF). Addition of ferric chloride ahead of the UF unit, but not ahead of the MF unit, may account for this additional removal of organic matter. However, the additional DOC removal appeared insufficient to explain the differential in foulant accumulation between high-pressure membranes receiving UF and MF pretreatment. Extensive autopsy analyses of these high-pressure membranes showed from 35% to 56% less organic carbon on those receiving UF rather than MF pretreatment. A more specific indicator of a differential in organic fouling was the accumulation of polysaccharides and this showed from 27% to 38% less on UF- than on MF-pretreated membranes. Yet another possible source of foulants is inorganic material given that the inorganic and organic weight percentages were nearly equal (56% vs. 44%) on the membrane surface. One specific source was aluminum added for phosphorus removal. Less fouling of high-pressure membranes pretreated by UF than MF could be due to the following: (1) a small, but very important, colloidal fouling fraction may have passed through MF but was rejected by UF pretreatment; (2) organic fouling was not related to organics in either the MF or UF filtrates but rather to organics that are generated in situ by microbial activity on the membrane surface; and/or (3) less passage of colloidal Al-P that carried over from secondary wastewater treatment.  相似文献   

2.
Ultrafiltration (UF) fouling has been attributed to concentration polarization, gel layer formation as well as outer and inner membrane pore clogging. It is believed that mass of humic materials either retained on membrane surface or associated with membrane inner pore surface is the primary cause for permeate flux decline and filtration resistance build-up in water supply industries. While biofilm/biofouling and inorganic matter could also be contributing factors for permeability decline in wastewater treatment practices. The present study relates UF fouling to mass of dissolved organic matter (DOM) retained on membrane and quantifies the effect of retained DOM mass on filtration flux decline. The results demonstrate that larger pore membranes exhibit significant flux decline in comparison with the smaller ones. During a 24-h period, dissolved organic carbon mass retained in 10 kDa membranes was about 1.0 g m−2 and that in 100 kDa membranes was more than 3 times higher (3.6 g m−2). The accumulation of retained DOM mass significantly affects permeate flux. It is highly likely that some DOMs bind or aggregate together to form surface gel layer in the smaller 10 kDa UF system; those DOMs largely present in inner pore and serving as pore blockage on a loose membrane (100 kDa) are responsible for severe flux decline.  相似文献   

3.
Xing Zheng  Martin Jekel 《Water research》2010,44(10):3203-3213
Natural biofiltration processes have been verified as effective pre-treatment choice improving the performance of low-pressure membranes (MF/UF) in wastewater reclamation. In the present work, pilot-scale slow sand filtration (SSF) was used to simulate bank filtration at high filtration rates (from 0.25 m/h to 0.5 m/h) to filter secondary effluent prior to UF. The results showed that SSF improved the performance of UF to a large extent. Related to previous work biopolymers are considered as major dissolved organic foulants in treated wastewater. The removal of these organic foulants in slow sand filters and factors affecting the performance of SSF were investigated. It was observed that the removal of biopolymers took place mainly at the upper sand layer and was related to biological degradation. Tests on the degradability of biopolymers verified that they are biodegradable. Sixteen months monitoring of biopolymer concentration in the secondary effluent indicated that it varied seasonally. In winter season the concentration was much higher than during the summer months. Higher temperature and lower biopolymer concentration led to more effective foulants removal and more sustainable operation of SSF. During the whole experimental period, the performance of SSF was always better at filtration rate of 0.25 m/h than at 0.5 m/h. Under the present experimental conditions, SSF exhibited stable and effective biopolymer removal at temperatures higher than 15 °C, at biopolymer concentrations lower than 0.5 mg C/L and with sufficient oxygen available.  相似文献   

4.
Chon K  Kim SJ  Moon J  Cho J 《Water research》2012,46(6):1803-1816
The effects of the combined coagulation-disk filtration (CC-DF) process on the fouling characteristics and behavior caused by interactions between effluent organic matter (EfOM) and the membrane surfaces of the ultrafiltration (UF) and reverse osmosis (RO) membranes in a pilot plant for municipal wastewater reclamation (MWR) were investigated. The feed water from secondary effluents was treated by the CC-DF process used as a pretreatment for the UF membrane to mitigate fouling formation and the permeate from the CC-DF process was further filtered by two UF membrane units in parallel arrangement and fed into four RO modules in a series connection. The CC-DF process was not sufficient to mitigate biofouling but the UF membrane was effective in mitigating biofouling on the RO membrane surfaces. Fouling of the UF and RO membranes was dominated by hydrophilic fractions of EfOM (e.g., polysaccharide-like and protein-like substances) and inorganic scaling (e.g., aluminum, calcium and silica). The desorbed UF membrane foulants included more aluminum species and hydrophobic fractions than the desorbed RO membrane foulants, which was presumably due to the residual coagulants and aluminum-humic substance complexes. The significant change in the surface chemistry of the RO membrane (a decrease in surface charge and an increase in contact angle of the fouled RO membranes) induced by the accumulation of hydrophilic EfOM onto the negatively charged RO membrane surface intensified the fouling formation of the fouled RO membrane by hydrophobic interaction between the humic substances of EfOM with relatively high hydrophobicity and the fouled RO membranes with decreased surface charge and increased contract angle.  相似文献   

5.
A 5-month monitoring program was undertaken in South Wales in the UK to determine the fate of 55 pharmaceuticals, personal care products, endocrine disruptors and illicit drugs (PPCPs) in two contrasting wastewater plants utilising two different wastewater treatment technologies: activated sludge and trickling filter beds. The impact of treated wastewater effluent on the quality of receiving waters was also assessed.PPCPs were found to be present at high loads reaching 10 kg day−1 in the raw sewage. Concentrations of PPCPs in raw sewage were found to correlate with their usage/consumption patterns in Wales and their metabolism. The efficiency of the removal of PPCPs was found to be strongly dependent on the technology implemented in the wastewater treatment plant (WWTP). In general, the WWTP utilising trickling filter beds resulted in, on average, less than 70% removal of all 55 PPCPs studied, while the WWTP utilising activated sludge treatment gave a much higher removal efficiency of over 85%. The monitoring programme revealed that treated wastewater effluents were the main contributors to PPCPs concentrations (up to 3 kg of PPCPs day−1) in the rivers studied. Bearing in mind that in the cases examined here the WWTP effluents were also major contributors to rivers' flows (dilution factor for the studied rivers did not exceed 23 times) the effect of WWTP effluent on the quality of river water is significant and cannot be underestimated.  相似文献   

6.
微滤/反渗透净化污水厂二级处理出水   总被引:8,自引:1,他引:8  
以微絮凝和微滤作为反渗透的预处理工艺,采用连续流微滤-反渗透集成膜工艺深度处理城市污水厂二级生物处理出水,比较了投加聚合氯化铝和氯化铁进行微絮凝控制微滤膜污染的效果.结果表明,投加氯化铁对微滤膜污染具有更好的控制效果;微滤出水浊度<0.5 NTU,对TOC的去除率为50%左右,对UV260的去除率<30%.  相似文献   

7.
Huang X  Leal M  Li Q 《Water research》2008,42(4-5):1142-1150
Natural organic matter (NOM) fouling continues to be the major barrier to efficient application of microfiltration (MF) and ultrafiltration (UF) in drinking water treatment. In this study, the potential of TiO2/UV photocatalytic oxidation to control fouling of membranes by NOM was evaluated. Decomposition kinetics of NOM was investigated using a commercial TiO2 catalyst, and the effect of various experimental parameters including TiO2 dosage and initial total organic carbon (TOC) concentration were also determined. The reaction kinetics was found to increase with increasing TiO2 dosage, but decrease with increasing initial TOC concentration. Even though the rate of TOC removal was relatively low, the TiO2/UV process was very effective in controlling membrane fouling by NOM. At a TiO2 concentration of 0.5 g/L, fouling of both an MF and a UF membrane was completely eliminated after 20 min of treatment. Careful analyses of specific UV absorbance (SUVA) and molecular weight (MW) distribution of NOM revealed that the effectiveness in membrane fouling control is the result of the changes in NOM molecular characteristics, namely MW and SUVA due to the preferential removal and transformation of large, hydrophobic NOM compounds. Results from this study show that TiO2/UV photocatalytic oxidation is a promising pretreatment method for MF and UF systems.  相似文献   

8.
E Filloux  H Gallard  JP Croue 《Water research》2012,46(17):5531-5540
Anion exchange resin (AER), powder activated carbon (PAC) adsorption and ozonation treatments were applied on biologically treated wastewater effluent with the objective to modify the effluent organic matter (EfOM) matrix. Both AER and PAC led to significant total organic carbon (TOC) removal, while the TOC remained nearly constant after ozonation. Liquid Chromatography-Organic Carbon Detection (LC-OCD) analysis showed that the AER treatment preferentially removed high and intermediate molecular weight (MW) humic-like structures while PAC removed low MW compounds. Only a small reduction of the high MW colloids (i.e. biopolymers) was observed for AER and PAC treatments. Ozonation induced a large reduction of the biopolymers and an important increase of the low MW humic substances (i.e. building blocks).Single-cycle microfiltration (MF) and ultrafiltration (UF) tests were conducted using commercially available hollow fibres at a constant flux. After reconcentration to their original organic carbon content, the EfOM matrix modified by AER and PAC treatments exhibited higher UF membrane fouling compared to untreated effluent; result that correlated with the higher concentration of biopolymers. On the contrary, ozonation which induced a significant degradation of the biopolymers led to a minor flux reduction for both UF and MF filtration tests. Based on a single filtration, results indicate that biopolymers play a major role in low pressure membrane fouling and that intermediate and low MW compounds have minor impact. Thus, this approach has shown to be a valid methodology to identify the foulant fractions of EfOM.  相似文献   

9.
Howe KJ  Marwah A  Chiu KP  Adham SS 《Water research》2007,41(17):3842-3849
Hollow fiber and flat sheet membranes were compared in side-by-side bench-scale experiments to evaluate whether the configuration has an impact on the rate of membrane fouling. Both microfiltration (MF) and ultrafiltration (UF) membranes were evaluated. In general, flat sheet membranes fouled more rapidly than hollow fiber membranes. Pretreatment such as coagulation generally affected both configurations similarly, but in some cases coagulation reduced fouling on hollow fiber membranes but increased fouling on flat sheet membranes. Prefiltration to remove foulants above 1microm in size had a consistent effect on both configurations. A bench-scale apparatus employing a single-fiber module that allows testing over multiple filter runs with integral backwashing capabilities was demonstrated to provide more detailed information about fouling, which can be applied to full-scale applications. When bench-scale tests are to be used to screen treatment options for full-scale applications, the use of a backwashable hollow fiber system is recommended.  相似文献   

10.
Ultrafiltration (UF) is considered as a suitable treatment process after conventional wastewater treatment to produce reuse water. Nevertheless, fouling affects the performance of UF to a large extent. As biopolymers (mostly macro polysaccharide-like and protein-like molecules) have been identified as major foulants affecting the filterability of water in dead-end UF, the present study focuses on investigating the reversibility of biopolymer fouling occurring at different biopolymer mass loads to the membrane and under different compression conditions. UF-membrane stirred cell tests using five cycles show that filtering treated domestic wastewater leads to a significant permeability reduction due to the accumulation of biopolymers on the membrane surface and/or in the membrane pores. Although they can be removed by hydraulic backwashing, an increased mass load of biopolymers reduces the removal efficiency. This correlation was verified using a UF pilot plant filtering treated wastewater (secondary effluent or slow sand filtrate). The effect of biopolymer fouling layer deformation on its reversibility was studied using multi-cycle membrane filtration tests under different filtration pressures. The results showed that higher filtration pressures result in more compact biopolymer fouling which is more difficult to be hydraulically backwashed. This phenomenon was also confirmed by pilot-scale UF experiments.  相似文献   

11.
Schäfer AI  Fane AG  Waite TD 《Water research》2001,35(6):1509-1517
This paper compares the membrane processes available for water treatment. Membranes have the advantage of currently decreasing capital cost, a relatively small footprint compared to conventional treatment, generally a reduction in chemicals usage and comparably low maintenance requirements. Three membrane processes applicable to water treatment, micro- (MF), ultra- (UF), and nanofiltration (NF), are compared in terms of intrinsic rejection, variation of rejection due to membrane fouling and increase in rejection by ferric chloride pretreatment. Twelve different membranes are compared on the basis of their membrane pore size which was calculated from their molecular weight cut-off. A pore size of < 6 nm is required to achieve substantial (> 50%) organics removal. For a fouled membrane this pore size is about 11 nm. UV rejection is higher than DOC rejection. Coagulation pretreatment allows a higher rejection of organics by MF and UF and the cut-off criterion due to initial membrane pore size is no longer valid. A water quality parameter (WQP) is introduced which describes the product water quality achieved as a function of colloid, DOC and cation rejection. The relationship between log (pore size) and WQP is linear. Estimation of membrane costs as a function of WQP suggests that open UF is superior to MF (similar cost at higher WQP) and NF is superior to tight UF. Chemical pretreatment could compensate for the difference between MF and UF. However, when considering chemicals and energy costs, it appears that a process operated at a higher energy is cheaper at a guaranteed product quality (less dependent on organic type). This argument is further supported by environmental issues of chemicals usage, as energy may be provided from renewable sources.  相似文献   

12.
Organic polymers are commonly used as coagulants or flocculants in pretreatment for microfiltration (MF). These high molecular weight compounds are potential membrane foulants when carried over to the MF filters. This study examined fouling of three MF membranes of different materials by three commonly used water treatment polymers: poly(diallyldimethylammonium) chloride (pDADMAC), polyacrylamide (PAM), and poly(acrylic acid-co-acrylamide (PACA) with a wide range of molecular weights. The effects of polymer molecular characteristics, membrane surface properties, solution condition and polymer concentration on membrane fouling were investigated. Results showed severe fouling of microfiltration membranes at very low polymer concentrations, suggesting that residual polymers carried over from the coagulation/flocculation basin can contribute significantly to membrane fouling. The interactions between polymers and membranes depended strongly on the molecular size and charge of the polymer. High molecular weight, positively charged polymers caused the greatest fouling. Blockage of membrane pore openings was identified as the main fouling mechanism with no detectable internal fouling in spite of the small molecular size of the polymers relative to the membrane pore size. Solution conditions (e.g., pH and calcium concentration) that led to larger polymer molecular or aggregate sizes resulted in greater fouling.  相似文献   

13.
The aim of this study was to quantify the amount of polybrominated diphenyl ethers (PBDEs) released into the environment (biosolids, effluent) from a conventional Australian activated sludge treatment wastewater treatment plant (WWTP). The concentration of PBDE congeners was measured at various treatment stages and included four aqueous samples (raw, primary, secondary and tertiary effluents) and three sludges (primary, secondary and lime stabilized biosolids), collected at three sampling events over the course of the experiment (29 days). Semi-permeable membrane devices (SPMDs) were also installed for the duration of the experiment, the first time that SPMDs have been used to measure PBDEs in a WWTP. Over 99% of the PBDEs entering the WWTP were removed through the treatment processes, principally by sedimentation. The main congeners detected were BDE 47, 99 and 209, which are characteristic of the two major commercial formulations viz penta-BDE and deca-BDE. All the PBDE congeners measured were highly correlated with each other, suggesting a similar origin. In this case, the PBDEs are thought to be from domestic sources since domestic wastewater is the main contribution to the in-flow (∼ 95%). The mean concentration of ΣPBDEs in chemically stabilized sewage sludge (biosolids) was 300 μg kg− 1 dry weight. It is calculated that 2.3 ± 0.3 kg of PBDEs are disposed of each year with biosolids generated from the WWTP. If all Australian sewage sludge is contaminated to at least this concentration then at least 110 kg of PBDEs are associated with Australian sewage sludge annually. Less than 10 g are released annually into the environment via ocean outfall and field irrigation; this level of contamination is unlikely to pose risk to humans or the environment. The environmental release of treated effluent and biosolids is not considered a large source of PBDE environmental emissions compared to the quantities used annually in Australia.  相似文献   

14.
The effects of microfiltration (MF) as pretreatment for reverse osmosis (RO) on biofouling of RO membranes were analyzed with secondary wastewater effluents. MF pretreatment reduced permeate flux decline two- to three-fold, while increasing salt rejection. Additionally, the oxygen uptake rate (OUR) in the biofouling layer of the RO membrane was higher for an RO system that received pretreated secondary wastewater effluent compared to a control RO system that received untreated secondary effluent, likely due to the removal of inert particulate/colloidal matter during MF. A higher cell viability in the RO biofilm was observed close to the membrane surface irrespective of pretreatment, which is consistent with the biofilm-enhanced concentration polarization effect. Bacterial 16S rRNA gene clone library analysis revealed dominant biofilm communities of Proteobacteria and Bacteroidetes under all conditions. The Cramer-von Mises test statistic showed that MF pretreatment did not significantly change the bacterial community structure of RO membrane biofilms, though it affected bacterial community structure of non-membrane-associated biofilms (collected from the feed tank wall). The finding that the biofilm community developed on the RO membrane was not influenced by MF pretreatment may imply that RO membranes select for a conserved biofilm community.  相似文献   

15.
Zheng X  Ernst M  Jekel M 《Water research》2009,43(1):238-59
Ultrafiltration (UF) membranes can be used after conventional wastewater treatment to produce particle free and hygienically safe water for reuse. However, membrane fouling affects the performance of UF to a large extent. Stirred cell tests with UF membrane show high flux decline filtering treated domestic wastewater. Investigation on the impact of size fractioned substances indicates that dissolved substances are major foulants affecting water filterability. Dissolved organic substances in feed and permeate samples of the stirred cell tests are analyzed by liquid chromatography with online organic carbon detection (LC-OCD). The resulting chromatograms displayed a significant difference of feed and permeate samples in the range of large molecules identified as biopolymer peak. The substances detected in this peak (mostly macro polysaccharide-like and protein-like molecules) are almost completely retained by UF membranes. Quantified investigation shows that biopolymer concentration influences filterability of corresponding water sample proportionally. The apparent magnitude of delivered biopolymer to membrane has a striking correlation with fouling resistance. The relationship was verified to be reproducible using different water samples. Mechanism analysis demonstrates that based on the delivered biopolymer load to membrane pore blocking or cake/gel fouling is the main fouling mechanism in the present experiment conditions.  相似文献   

16.
Lee N  Amy G  Croué JP  Buisson H 《Water research》2004,38(20):4511-4523
An understanding of natural organic matter (NOM) as a membrane foulant and the behavior of NOM components in low-pressure membrane fouling are needed to provide a basis for appropriate selection and operation of membrane technology for drinking water treatment. Fouling by NOM was investigated by employing several innovative chemical and morphological analyses.

Source (feed) waters with a high hydrophilic (HPI) fraction content of NOM resulted in significant flux decline. Macromolecules of a relatively hydrophilic character (e.g. polysaccharides) were effectively rejected by low-pressure membranes, suggesting that macromolecular compounds and/or colloidal organic matter in the hydrophilic NOM fraction may be a problematic foulant of low-pressure membranes. Moreover, the significant organic fouling that is contributed by polysaccharides and/or proteins in macromolecular and/or colloidal forms depends on molecular shape (structure) as well as size (i.e. molecular weight). More significant flux decline was observed in microfiltration (MF) compared to ultrafiltration (UF) membrane filtration. MF membrane fouling may be caused by pore blockage associated with large (macromolecular) hydrophilic molecules and/or organic colloids. In the case of UF membranes, the flux decline may be caused by sequential or simultaneous processes of surface (gel layer) coverage during filtration. Morphological analyses support the notion that membrane roughness may be considered as a more important factor in membrane fouling by controlling interaction between molecules and the membrane surface, compared to the hydrophobic/hydrophilic character of membranes. Membrane fouling mechanisms are not only a function of membrane type (MF versus UF) but also depend on source (feed) water characteristics.  相似文献   


17.
粉末活性炭/污泥回流工艺强化膜前预处理的研究   总被引:2,自引:1,他引:1  
采用粉末活性炭(PAC)吸附/混凝沉淀/浸没式超滤膜组合工艺处理苏州市某河水,考察了PAC/污泥回流工艺对膜前预处理的强化效果及对膜污染的影响,并与常规混凝沉淀、污泥回流强化混凝沉淀、PAC吸附/混凝沉淀等3种预处理工艺进行了对比。结果表明,PAC/污泥回流强化预处理工艺对浊度、DOC、UV254和THMFP的去除率分别为80.2%、47.5%、42.3%和52.3%,均比其他预处理工艺的高,对MW30 ku和MW1 ku有机物的去除效果明显。PAC/污泥回流强化预处理和超滤膜组合工艺对浊度、DOC、UV254和THMFP的去除率分别可达到99.2%、54.1%、47.2%和60.2%;经过15 d的运行,超滤膜的跨膜压差基本保持稳定,而其他预处理工艺虽能在一定程度上减轻膜污染,但无法避免不可逆膜污染的发生。  相似文献   

18.
19.
何维涛 《四川建材》2013,(4):114-115,117
作为一种具有发展前景的饮用水净化工艺,超滤膜技术日益得到广泛应用。但是膜污染一直是困扰其发展的主要因素。将传统的处理技术与超滤膜相结合,通过预处理的方式在提高水质的同时可以防止膜污染的生成。本文主要讨论了混凝、吸附、预氧化和其他预处理方法及其组合方法在水处理中应用和对膜污染的抑制作用。未来研究方向应在深入讨论膜污染机理的基础上,针对不同情况进行分析。  相似文献   

20.
Decolorization of wastewater of a Baker's yeast plant by membrane processes   总被引:8,自引:0,他引:8  
The aim of this study is to develop a membrane-based treatment scheme to remove colorants from the effluent of a baker's yeast plant. For this purpose microfiltration (MF), ultrafiltration (UF) and nanofiltraton (NF) membranes with differing molecular weight cut-offs (MWCOs) were tested. To evaluate the effectiveness of membrane processes in treating the waste stream, optical density (OD), COD, color measurements together with permeation fluxes were used. Effects of pretreatment methods (coagulation and coarse filtration) and feed composition on OD, color, COD were studied. In addition, gel filtration analysis was employed to characterize feed and permeate streams in terms of MW distribution of organics that are present. Maximum rejections obtained were 94%, 89% and 72% for OD, color and COD, respectively, when 0.8 microm microfiltration membrane and 400 Da NF membrane were used in series. It was also observed that addition of intermediate UF steps did not increase overall rejections and final permeate flux of NF membrane. Based on these observations, an efficient scheme was offered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号