首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectivesThe purpose of this study was to assess the temporal trends of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic stenosis (AS), and to compare the outcomes between TAVR and surgical aortic valve replacement (SAVR) in this population.BackgroundRandomized trials comparing TAVR to SAVR in AS with bicuspid valve are lacking.MethodsThe study queried the National Inpatient Sample database (years 2012 to 2016) to identify hospitalizations for bicuspid AS who underwent isolated aortic valve replacement. A propensity-matched analysis was used to compare outcomes of hospitalizations for TAVR versus SAVR for bicuspid AS and TAVR for bicuspid AS versus tricuspid AS.ResultsThe analysis included 31,895 hospitalizations with bicuspid AS, of whom 1,055 (3.3%) underwent TAVR. TAVR was increasingly utilized during the study period for bicuspid AS (ptrend = 0.002). After matching, TAVR and SAVR had similar in-hospital mortality (3.1% vs. 3.1%; odds ratio: 1.00; 95% confidence interval: 0.60 to 1.67). There was no difference between TAVR and SAVR in the rates of cardiac arrest, cardiogenic shock, acute kidney injury, hemopericardium, cardiac tamponade, or acute stroke. TAVR was associated with lower rates of acute myocardial infarction, post-operative bleeding, vascular complications, and discharge to nursing facility as well as a shorter length of hospital stay. On the contrary, TAVR was associated with a higher incidence of complete heart block and permanent pacemaker insertion. TAVR for bicuspid AS was associated with similar in-hospital mortality compared with tricuspid AS.ConclusionsThis nationwide analysis showed similar in-hospital mortality for TAVR and SAVR in patients with bicuspid AS. TAVR for bicuspid AS was also associated with similar in-hospital mortality compared with tricuspid AS. Further studies are needed to evaluate long-term outcomes of TAVR for bicuspid AS.  相似文献   

2.
BackgroundSurgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions.ObjectivesThe aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs).MethodsData were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year.ResultsFor TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003).ConclusionsIn propensity score–matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.  相似文献   

3.
Current guidelines recommend that clinical surveillance for patients with moderate aortic stenosis (AS) and aortic valve replacement (AVR) may be considered if there is an indication for coronary revascularization. Recent observational studies, however, have shown that moderate AS is associated with an increased risk of cardiovascular events and mortality. Whether the increased risk of adverse events is caused by associated comorbidities, or to the underlying moderate AS itself, is incompletely understood. Similarly, which patients with moderate AS need close follow-up or could potentially benefit from early AVR is also unknown. In this review, the authors provide a comprehensive overview of the current published reports on moderate AS. They first provide an algorithm that helps to diagnose moderate AS correctly, especially when discordant grading is observed. Although the traditional focus of AS assessment has been on the valve, it is increasingly acknowledged that AS is not only a disease of the aortic valve but also of the ventricle. The authors therefore discuss how multimodality imaging can help to evaluate the left ventricular remodeling response and improve risk stratification in patients with moderate AS. Finally, they summarize current evidence on the management of moderate AS and highlight ongoing trials on AVR in moderate AS.  相似文献   

4.
ObjectivesThe aim of this study was to assess 10-year all-cause mortality in patients with heavily calcified lesions (HCLs) undergoing percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG).BackgroundLimited data are available on very long term outcomes in patients with HCLs according to the mode of revascularization.MethodsThis substudy of the SYNTAXES (Synergy Between PCI With Taxus and Cardiac Surgery Extended Survival) study assessed 10-year all-cause mortality according to the presence of HCLs within lesions with >50% diameter stenosis and identified during the calculation of the anatomical SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) score among 1,800 patients with the 3-vessel disease and/or left main disease randomized to PCI or CABG in the SYNTAX trial. Patients with HCLs were further stratified according to disease type (3-vessel disease or left main disease) and assigned treatment (PCI or CABG).ResultsThe 532 patients with ≥1 HCL had a higher crude mortality rate at 10 years than those without (36.4% vs 22.3%; HR: 1.79; 95% CI: 1.49-2.16; P < 0.001). After adjustment, an HCL remained an independent predictor of 10-year mortality (HR: 1.36; 95% CI: 1.09-1.69; P = 0.006). There was a significant interaction in mortality between treatment effect (PCI and CABG) and the presence or absence of HCLs (Pinteraction = 0.005). In patients without HCLs, mortality was significantly higher after PCI than after CABG (26.0% vs 18.8%; HR: 1.44; 95% CI: 0.97-1.41; P = 0.003), whereas in those with HCLs, there was no significant difference (34.0% vs 39.0%; HR: 0.85; 95% CI: 0.64-1.13; P = 0.264).ConclusionsAt 10 years, the presence of an HCL was an independent predictor of mortality, with a similar prognosis following PCI or CABG. Whether HCLs require special consideration when deciding the mode of revascularization beyond their current contribution to the anatomical SYNTAX score deserves further evaluation. (Synergy Between PCI With TAXUS and Cardiac Surgery: SYNTAX Extended Survival [SYNTAXES], NCT03417050; SYNTAX Study: TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries [SYNTAX], NCT00114972)  相似文献   

5.
ObjectivesThe aim of this study was to determine the impact of delayed high-degree atrioventricular block (HAVB) or complete heart block (CHB) after transcatheter aortic valve replacement (TAVR) using a minimalist approach followed by ambulatory electrocardiographic (AECG) monitoring.BackgroundLittle is known regarding the clinical impact of HAVB or CHB in the early period after discharge following TAVR.MethodsA prospective, multicenter study was conducted, including 459 consecutive TAVR patients without permanent pacemaker who underwent continuous AECG monitoring for 14 days (median length of hospital stay 2 days; IQR: 1-3 days), using 2 devices (CardioSTAT and Zio AT). The primary endpoint was the occurrence of HAVB or CHB. Patients were divided into 3 groups: 1) no right bundle branch block (RBBB) and no electrocardiographic (ECG) changes; 2) baseline RBBB with no further changes; and 3) new-onset ECG conduction disturbances.ResultsDelayed HAVB or CHB episodes occurred in 21 patients (4.6%) (median 5 days postprocedure; IQR: 4-6 days), leading to PPM in 17 (81.0%). HAVB or CHB events were rare in group 1 (7 of 315 [2.2%]), and the incidence increased in group 2 (5 of 38 [13.2%]; P < 0.001 vs group 1) and group 3 (9 of 106 [8.5%]; P = 0.007 vs group 1; P = 0.523 vs group 2). No episodes of sudden or all-cause death occurred at 30-day follow-up.ConclusionsSystematic 2-week AECG monitoring following minimalist TAVR detected HAVB and CHB episodes in about 5% of cases, with no mortality at 1 month. Whereas HAVB or CHB was rare in patients without ECG changes post-TAVR, baseline RBBB and new-onset conduction disturbances determined an increased risk. These results would support tailored management using AECG monitoring and the possibility of longer hospitalization periods in patients at higher risk for delayed HAVB or CHB.  相似文献   

6.
ObjectivesThe authors explored the development and validation of machine-learning models for augmenting the echocardiographic grading of aortic stenosis (AS) severity.BackgroundIn AS, symptoms and adverse events develop secondarily to valvular obstruction and left ventricular decompensation. The current echocardiographic grading of AS severity focuses on the valve and is limited by diagnostic uncertainty.MethodsUsing echocardiography (ECHO) measurements (ECHO cohort, n = 1,052), we performed patient similarity analysis to derive high-severity and low-severity phenogroups of AS. We subsequently developed a supervised machine-learning classifier and validated its performance with independent markers of disease severity obtained using computed tomography (CT) (CT cohort, n = 752) and cardiovascular magnetic resonance (CMR) imaging (CMR cohort, n = 160). The classifier’s prognostic value was further validated using clinical outcomes (aortic valve replacement [AVR] and death) observed in the ECHO and CMR cohorts.ResultsIn 1,964 patients from the 3 multi-institutional cohorts, 1,346 (68%) subjects had either nonsevere or discordant AS severity. Machine learning identified 1,117 (57%) patients as having high-severity and 847 (43%) as having low-severity AS. High-severity patients in CT and CMR cohorts had higher valve calcium scores and left ventricular mass and fibrosis, respectively than the low-severity group. In the ECHO cohort, progression to AVR and progression to death in patients who did not receive AVR was faster in the high-severity group. Compared with the conventional classification of disease severity, machine-learning–based severity classification improved discrimination (integrated discrimination improvement: 0.07; 95% confidence interval: 0.02 to 0.12) and reclassification (net reclassification improvement: 0.17; 95% confidence interval: 0.11 to 0.23) for the outcome of AVR at 5 years. For both ECHO and CMR cohorts, we observed prognostic value of the machine-learning classifications for subgroups with asymptomatic, nonsevere or discordant AS.ConclusionsMachine learning can integrate ECHO measurements to augment the classification of disease severity in most patients with AS, with major potential to optimize the timing of AVR.  相似文献   

7.
BackgroundThe study investigators previously reported that moderate aortic stenosis (AS) is associated with a poor prognosis in patients with heart failure (HF) with reduced left ventricular ejection fraction (LVEF) (HFrEF). However, the respective contribution of moderate AS versus HFrEF to the outcomes of these patients is unknown.ObjectivesThis study sought to determine the impact of moderate AS on outcomes in patients with HFrEF.MethodsThe study included 262 patients with moderate AS (aortic valve area >1.0 and <1.5 cm2; and peak aortic jet velocity >2 and <4 m/s, at rest or after dobutamine stress echocardiography) and HFrEF (LVEF <50%). These patients were matched 1:1 for sex, age, estimated glomerular filtration rate, New York Heart Association functional class III to IV, presence of diabetes, LVEF, and body mass index with patients with HFrEF but no AS (i.e., peak aortic jet velocity <2 m/s). The endpoints were all-cause mortality and the composite of death and HF hospitalization.ResultsA total of 262 patients with HFrEF and moderate AS were matched with 262 patients with HFrEF and no AS. Mean follow-up was 2.9 ± 2.2 years. In the moderate AS group, mean aortic valve area was 1.2 ± 0.2 cm2, and mean gradient was 14.5 ± 4.7 mm Hg. Moderate AS was associated with an increased risk of mortality (hazard ratio [HR]: 2.98; 95% confidence interval [CI]: 2.08 to 4.31; p < 0.0001) and of the composite of HF hospitalization and mortality (HR: 2.34; 95% CI: 1. 72 to 3.21; p < 0.0001). In the moderate AS group, aortic valve replacement (AVR) performed in 44 patients at a median follow-up time of 10.9 ± 16 months during follow-up was associated with improved survival (HR: 0.59; 95% CI: 0.35 to 0.98; p = 0.04). Notably, surgical AVR was not significantly associated with improved survival (p = 0.92), whereas transcatheter AVR was (HR: 0.43; 95% CI: 0.18 to 1.00; p = 0.05).ConclusionsIn this series of patients with HFrEF, moderate AS was associated with a marked incremental risk of mortality. AVR, and especially transcatheter AVR during follow-up, was associated with improved survival in patients with HFrEF and moderate AS. These findings provide support to the realization of a randomized trial to assess the effect of early transcatheter AVR in patients with HFrEF and moderate AS.  相似文献   

8.
BackgroundPsychosocial risk factors (PSRFs) have emerged as important nontraditional risk factors that are associated with worse surgical outcomes but have not been well-characterized in valvular disease.ObjectivesThis study evaluates the impact of PSRFs on 30-day outcomes following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR).MethodsAll adult patients (≥18 years of age) who underwent isolated TAVR or SAVR in the Nationwide Readmissions Database from 2016 to 2018 were included. Patients were classified as having 0 PSRFs vs ≥1 PSRF. PSRFs included limited cognitive understanding, substance use, psychiatric disease, low socioeconomic status, or uninsured status. Primary outcomes included 30-day mortality, readmission, and composite morbidity (stroke, pulmonary embolus, pacemaker implantation, bleeding complications, acute kidney injury, myocardial infarction, or new atrial fibrillation).ResultsA nationally weighted total of 74,763 SAVR and 87,142 TAVR patients met inclusion criteria. For SAVR, patients with PSRFs had significantly higher 30-day mortality (4.2% vs 3.7%; P = 0.048) and readmissions (13.1% vs 11.3%; P < 0.001), but there was no difference in composite morbidity. For TAVR, patients with PSRFs had significantly higher 30-day readmission (11.7% vs 10.7%; P = 0.012) but no difference in 30-day mortality or composite morbidity. On risk-adjusted analysis, presence of PSRFs was a significant predictor of higher 30-day readmissions following SAVR (adjusted OR: 1.10; 95% CI: 1.02-1.19).ConclusionsThe presence of PSRFs is associated with worse short-term outcomes following SAVR and TAVR, with a more profound impact in SAVR. This study highlights the importance of identifying at-risk patients and suggests that TAVR may be beneficial in patients with less social support.  相似文献   

9.
Expansion of extracellular fluid volume is central to the pathophysiology of heart failure. Increased extracellular fluid leads to elevated intracardiac filling pressures, resulting in a constellation of signs and symptoms of heart failure referred to as congestion. Loop diuretics are one of the cornerstones of treatments for heart failure, but in contrast to other therapies, robust clinical trial evidence to guide the use of diuretics is sparse. A nuanced understanding of renal physiology and diuretic pharmacokinetics is essential for skillful use of diuretics in the management of heart failure in both the inpatient and outpatient settings. Diuretic resistance, defined as an inadequate quantity of natriuresis despite an adequate diuretic regimen, is a major clinical challenge that generally portends a poor prognosis. In this review, the authors discuss the fundamental mechanisms and physiological principles that underlie the use of diuretic therapy and the available data on the optimal use of diuretics.  相似文献   

10.
ObjectivesThis study sought to evaluate the ability of individual markers of frailty to predict outcomes after transcatheter aortic valve replacement (TAVR) and of their discriminatory value in different age groups.BackgroundAppropriate patient selection for TAVR remains a dilemma, especially among the most elderly and potentially frail.MethodsThe study evaluated patients ≥65 years of age in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy registry, linked to Centers for Medicare and Medicaid administrative claims data, receiving elective TAVR from November 2011 to June 2016 (n = 36,242). Indices of frailty included anemia, albumin level, and 5-m walk speed. We performed Cox proportional hazards regression for 30-day and 1-year mortality, adjusting for risk factors known to be predictive of 30-day mortality in the Transcatheter Valve Therapy registry, as well as survival analysis.ResultsThese indices are independently associated with mortality at 30 days and 1 year and provide incremental value in risk stratification for mortality, with low albumin providing the largest value (hazard ratio: 1.52). Those with low albumin and slower walking speed had longer lengths of stay and higher rates of bleeding and readmission (p < 0.001). Those with anemia also had higher rates of bleeding, readmission, and subsequent myocardial infarction (p < 0.001).ConclusionsThis represents the largest study to date of the role of frailty indices after TAVR, further facilitating robust modeling and adjusting for a large number of confounders. These simple indices are easily attainable, and clinically relevant markers of frailty that may meaningfully stratify patients at risk for mortality after TAVR.  相似文献   

11.
Endothelial injury and microvascular/macrovascular thrombosis are common pathophysiological features of coronavirus disease-2019 (COVID-19). However, the optimal thromboprophylactic regimens remain unknown across the spectrum of illness severity of COVID-19. A variety of antithrombotic agents, doses, and durations of therapy are being assessed in ongoing randomized controlled trials (RCTs) that focus on outpatients, hospitalized patients in medical wards, and patients critically ill with COVID-19. This paper provides a perspective of the ongoing or completed RCTs related to antithrombotic strategies used in COVID-19, the opportunities and challenges for the clinical trial enterprise, and areas of existing knowledge, as well as data gaps that may motivate the design of future RCTs.  相似文献   

12.
BackgroundDisease progression in patients with mild-to-moderate aortic stenosis is heterogenous and requires periodic echocardiographic examinations to evaluate severity.ObjectivesThis study sought to explore the use of machine learning to optimize aortic stenosis echocardiographic surveillance automatically.MethodsThe study investigators trained, validated, and externally applied a machine learning model to predict whether a patient with mild-to-moderate aortic stenosis will develop severe valvular disease at 1, 2, or 3 years. Demographic and echocardiographic patient data to develop the model were obtained from a tertiary hospital consisting of 4,633 echocardiograms from 1,638 consecutive patients. The external cohort was obtained from an independent tertiary hospital, consisting of 4,531 echocardiograms from 1,533 patients. Echocardiographic surveillance timing results were compared with the European and American guidelines echocardiographic follow-up recommendations.ResultsIn internal validation, the model discriminated severe from nonsevere aortic stenosis development with an area under the receiver-operating characteristic curve (AUC-ROC) of 0.90, 0.92, and 0.92 for the 1-, 2-, or 3-year interval, respectively. In external application, the model showed an AUC-ROC of 0.85, 0.85, and 0.85, for the 1-, 2-, or 3-year interval. A simulated application of the model in the external validation cohort resulted in savings of 49% and 13% of unnecessary echocardiographic examinations per year compared with European and American guideline recommendations, respectively.ConclusionsMachine learning provides real-time, automated, personalized timing of next echocardiographic follow-up examination for patients with mild-to-moderate aortic stenosis. Compared with European and American guidelines, the model reduces the number of patient examinations.  相似文献   

13.
ObjectivesThis study sought to determine the incidence, clinical impact, and changes over time of mitral regurgitation (MR) in patients with low-flow, low-gradient aortic stenosis (LFLG-AS) undergoing transcatheter aortic valve replacement (TAVR).BackgroundFew data exist on the clinical impact and changes in severity over time of MR in patients with LFLG-AS undergoing TAVR.MethodsA total of 308 TAVR candidates with LFLG-AS were included. Patients were categorized according to MR severity at baseline, and presence of MR improvement at 12-month follow-up. Clinical outcomes were assessed at 1 and 12 months (+ echocardiography), and yearly thereafter.ResultsBaseline mild and moderate-to-severe MR were present in 118 (38.3%) and 115 (37.3%) patients, respectively. MR was of functional and mixed etiology in 77.2% and 22.7% of patients, respectively. A total of 131 patients (42.5%) died after a median follow-up of 2 (1 to 3) years. Baseline moderate-or-greater MR had no impact on mortality (hazard ratio [HR]: 1.34; 95% confidence interval [CI]: 0.72 to 2.48) or heart failure hospitalization (HR: 1.02; 95% CI: 0.49 to 2.10). At 1-year follow-up, MR improved in 44.3% of patients and remained unchanged/worsened in 55.7%. The lack of MR improvement was associated with a higher risk of all-cause and cardiac mortality (HR: 2.02; 95% CI: 1.29 to 3.17; HR: 3.03; 95% CI: 1.27 to 7.23, respectively), rehospitalization for cardiac causes (HR: 1.50; 95% CI: 1.04 to 2.15), and an increased overall-mortality/heart failure rehospitalization (HR: 1.94; 95% CI: 1.25 to 3.02). A higher baseline left ventricular end-diastolic diameter and a higher increase in left ventricular ejection fraction were found to be independent predictors of MR improvement at 1-year follow-up (odds ratio: 0.69; 95% CI: 0.51 to 0.94; and odds ratio: 0.81; 95% CI: 0.67 to 0.96, respectively).ConclusionsMost TAVR candidates with LFLG-AS had some degree of MR, of functional origin in most cases. MR improved in about one-half of patients, with larger left ventricular size and a higher increase in left ventricular ejection fraction post-TAVR determining MR improvement over time. The lack of MR improvement at 1 year was associated with poorer outcomes.  相似文献   

14.
BackgroundMyocarditis is a potentially fatal complication of immune checkpoint inhibitor (ICI) therapy. Data on the utility of cardiovascular magnetic resonance (CMR) T1 and T2 mapping in ICI myocarditis are limited.ObjectivesThis study sought to assess the value of CMR T1 and T2 mapping in patients with ICI myocarditis.MethodsIn this retrospective study from an international registry of patients with ICI myocarditis, clinical and CMR findings (including T1 and T2 maps) were collected. Abnormal T1 and T2 were defined as 2 SD above site (vendor/field strength specific) reference values and a z-score was calculated for each patient. Major adverse cardiovascular events (MACE) were a composite of cardiovascular death, cardiogenic shock, cardiac arrest, and complete heart block.ResultsOf 136 patients with ICI myocarditis with a CMR, 86 (63%) had T1 maps and 79 (58%) also had T2 maps. Among the 86 patients (66.3 ± 13.1 years of age), 36 (41.9%) had a left ventricular ejection fraction <55%. Across all patients, mean z-scores for T1 and T2 values were 2.9 ± 1.9 (p < 0.001) and 2.2 ± 2.1 (p < 0.001), respectively. On Siemens 1.5-T scanner (n = 67), native T1 (1,079.0 ± 55.5 ms vs. 1,000.3 ± 22.1 ms; p < 0.001) and T2 (56.2 ± 4.9 ms vs. 49.8 ± 2.2 ms; p < 0.001) values were elevated compared with reference values. Abnormal T1 and T2 values were seen in 78% and 43% of the patients, respectively. Applying the modified Lake Louise Criteria, 95% met the nonischemic myocardial injury criteria and 53% met the myocardial edema criteria. Native T1 values had excellent discriminatory value for subsequent MACE, with an area under the curve of 0.91 (95% confidence interval: 0.84 to 0.98). Native T1 values (for every 1-unit increase in z-score, hazard ratio: 1.44; 95% confidence interval: 1.12 to 1.84; p = 0.004) but not T2 values were independently associated with subsequent MACE.ConclusionsThe use of T1 mapping and application of the modified Lake Louise Criteria provides important diagnostic value, and T1 mapping provides prognostic value in patients with ICI myocarditis.  相似文献   

15.
BackgroundSelf-expanding transcatheter heart valves (THVs) are associated with better echocardiographic hemodynamic performance than balloon-expandable THVs and are considered preferable in patients with small annuli.ObjectivesThis study sought to compare 5-year outcomes between self-expanding vs balloon-expandable THVs in severe aortic stenosis (AS) patients with small annuli.MethodsConsecutive severe AS patients with an aortic valve annulus area <430 mm2 who underwent transcatheter aortic valve replacement (TAVR) with either the CoreValve Evolut (Medtronic) or SAPIEN (Edwards Lifesciences) THV between 2012 and 2021 were enrolled from the Bern TAVI registry. A 1:1 propensity-matched analysis was performed to account for baseline differences between groups.ResultsA total of 723 patients were included, and propensity score matching resulted in 171 pairs. Technical success was achieved in over 85% of both groups with no significant difference. Self-expanding THVs were associated with a lower transvalvular gradient (8.0 ± 4.8 mm Hg vs 12.5 ± 4.5 mm Hg; P < 0.001), a larger effective orifice area (1.81 ± 0.46 cm2 vs 1.49 ± 0.42 cm2; P < 0.001), and a lower incidence of prosthesis-patient mismatch (19.7% vs 51.8%; P < 0.001) than balloon-expandable THVs. At 5 years, there were no significant differences in mortality (50.4% vs 39.6%; P = 0.269) between groups. Disabling stroke occurred more frequently in patients with a self-expanding THV than those with a balloon-expandable THV (6.6% vs 0.6%; P = 0.030). Similar results were obtained using inverse probability of treatment weighting in the Bern TAVI registry and the nationwide Swiss TAVI registry.ConclusionsThe echocardiographic hemodynamic advantage of self-expanding THVs was not associated with better clinical outcomes compared with balloon-expandable THVs up to 5 years in patients with small annuli. (Swiss TAVI Registry; NCT01368250)  相似文献   

16.
BackgroundData on outcomes of transcatheter aortic valve replacement (TAVR) using balloon-expandable valves (BEVs) or self-expandable valves (SEVs) as well as the impact of center valve preference on these outcomes are limited.ObjectivesThe aim of this study was to compare outcomes of TAVR procedures using third-generation BEVs and SEVs stratified by center valve preference.MethodsIn a multicenter registry (n = 17), 13 centers exhibited valve preference (66.6%-90% of volume) and were included. Outcomes were compared between BEVs and SEVs stratified by center valve preference.ResultsIn total, 7,528 TAVR procedures (3,854 with SEVs and 3,674 with BEVs) were included. The mean age was 81 years, and the mean Society of Thoracic Surgeons score was 5.2. Baseline characteristics were similar between BEVs and SEVs. Need for pacemaker implantation was higher with SEVs at BEV- and SEV-dominant centers (17.8% vs 9.3% [P < 0.001] and 12.7% vs 10.0% [P = 0.036], respectively; HR: 1.51; P for interaction = 0.021), risk for cerebrovascular accident was higher with SEVs at BEV-dominant but not SEV-dominant centers (3.6% vs 1.1% [P < 0.001] and 2.2% vs 1.4% [P = 0.162]; HR: 2.08; P for interaction < 0.01). Aortic regurgitation greater than mild was more frequent with SEVs at BEV-dominant centers and similar with BEVs regardless of center dominance (5.2% vs 2.8% [P < 0.001] and 3.4% vs 3.7% [P = 0.504], respectively). Two-year mortality was higher with SEVs at BEV-dominant centers but not at SEV-dominant centers (21.9% vs 16.9% [P = 0.021] and 16.8% vs 16.5% [P = 0.642], respectively; HR: 1.20; P for interaction = 0.032).ConclusionsPeriprocedural outcomes, aortic regurgitation greater than mild, and 2-year mortality are worse when TAVR is performed using SEVs at BEV-dominant centers. Outcomes are similar regardless of valve type at SEV-dominant centers. The present results stress the need to account for this factor when comparing BEV and SEV outcomes. (The Aortic+Mitral Transcatheter [AMTRAC] Valve Registry; NCT04031274)  相似文献   

17.
BackgroundCausal risk factors for aortic valve stenosis are poorly understood, limiting the possibility of preventing the most common heart valve disease.ObjectivesThe hypothesis was tested that genetically based obesity measured by body mass index is causally associated with risk of aortic valve stenosis and replacement.MethodsThe authors included 108,211 individuals from the Copenhagen General Population Study. Participants had measurements of body mass index, waist-hip ratio, and waist circumference, and information on 5 genetic variants associated with obesity. A Mendelian randomization design was used to investigate genetic and observational associations of obesity with incident aortic valve stenosis (n = 1,215) and replacement (n = 467) for a median follow-up time of 8.7 years.ResultsGenetically increased body mass index was causally associated with increased risk of aortic valve stenosis. Compared with an unweighted allele score of 0 to 3, individuals with an allele score 7 to 10 had a mean increase in body mass index of 0.87 kg/m2, and the age and sex–adjusted hazard ratio for aortic valve stenosis was 1.3 (95% confidence interval [CI]: 1.0 to 1.7) for allele score 4, 1.4 (95% CI: 1.1 to 1.8) for allele score 5 to 6, and 1.6 (95% CI: 1.3 to 2.1) for allele score 7 to 10 (p for trend: 9 × 10−5). A 1-kg/m2 increase in body mass index was associated with causal risk ratios for aortic valve stenosis and replacement, respectively, of 1.52 (95% CI: 1.23 to 1.87) and 1.49 (95% CI: 1.07 to 2.08) genetically, and with corresponding hazard ratios of 1.06 (95% CI: 1.05 to 1.08) and 1.06 (95% CI: 1.03 to 1.08) observationally.ConclusionsObesity from human genetics was causally associated with higher risk of aortic valve stenosis and replacement.  相似文献   

18.
ObjectivesThis study sought to investigate the impact of computed tomography (CT)–based area and perimeter oversizing on the incidence of paravalvular regurgitation (PVR) and valve hemodynamics in patients treated with the SAPIEN 3 transcatheter heart valve (THV).BackgroundThe incremental value of considering annular perimeter or left ventricular outflow tract measurements and the impact of THV oversizing on valve hemodynamics are not well defined.MethodsThe PARTNER 3 (Placement of Aortic Transcatheter Valves 3) trial included 495 low-surgical-risk patients with severe aortic stenosis who underwent THV implantation. THV sizing was based on annular area assessed by CT. Area- and perimeter-based oversizing was determined using systolic annular CT dimensions and nominal dimensions of the implanted THV. PVR, effective orifice area, and mean gradient were assessed on 30-day transthoracic echocardiography.ResultsOf 485 patients with available CT and echocardiography data, mean oversizing was 7.9 ± 8.7% for the annulus area and 2.1 ± 4.1% for the perimeter. A very low incidence of ≥moderate PVR (0.6%) was observed, including patients with minimal annular oversizing. Incidence of ≥mild PVR and need for procedural post-dilatation were inversely related to the degree of oversizing. For patients with annular dimensions suitable for 2 THV sizes, the larger THV with both area and perimeter oversizing was associated with the lowest incidence of ≥mild PVR (12.0% vs 43.4%; P < 0.0001). Left ventricular outflow tract area oversizing was not associated with PVR. THV prosthesis size, rather than degree of oversizing, had greatest impact on effective orifice area and mean gradient.ConclusionsIn low-surgical-risk patients, a low incidence of ≥moderate PVR was observed, including patients with minimal THV oversizing. The degree of prosthesis oversizing had the greatest impact on reducing mild PVR and incidence of post-dilatation, without impacting valve hemodynamics. In selected patients with annular dimensions in between 2 valve sizes, the larger THV device oversized to both the annular area and perimeter reduced PVR and optimized THV hemodynamics.  相似文献   

19.
ObjectivesThe aim of this study was to evaluate the feasibility of coronary access and aortic valve reintervention in low-risk patients undergoing transcatheter aortic valve replacement (TAVR) with a balloon-expandable transcatheter heart valve (THV).BackgroundYounger, low-risk TAVR patients are more likely than older, higher risk patients to require coronary angiography, percutaneous coronary intervention, or aortic valve reintervention, but their THVs may impede coronary access and cause coronary obstruction during TAVR-in-TAVR.MethodsThe LRT (Low Risk TAVR) trial (NCT02628899) enrolled 200 subjects with symptomatic severe aortic stenosis to undergo TAVR using commercially available THVs. Subjects who received balloon-expandable THVs and who had 30-day cardiac computed tomographic scans were included in this study. In a subgroup, the feasibility of intentional THV crimping on the delivery catheter to pre-determine commissural alignment was tested.ResultsIn the LRT trial, 168 subjects received balloon-expandable THVs and had 30-day cardiac computed tomographic scans, of which 137 were of adequate image quality for analysis. The most challenging anatomy for coronary access (THV frame above and commissural suture post in front of a coronary ostium) was observed in 9% to 13% of subjects. Intentional THV crimping did not appear to meaningfully affect commissural alignment. The THV frame extended above the sinotubular junction in 21% of subjects, and in 13%, the distance between the THV and the sinotubular junction was <2 mm, signifying that TAVR-in-TAVR may not be feasible without causing coronary obstruction.ConclusionsTAVR may present challenges to future coronary access and aortic valve reintervention in a substantial number of low-risk patients.  相似文献   

20.
ObjectivesThe aim of this study was to compare the incidence and prognostic significance of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) according to racial groups.BackgroundPPM after TAVR may be of more concern in Asian populations considering their relatively small annular and valve sizes compared with Western populations.MethodsTP-TAVR (Transpacific TAVR Registry) was an international multicenter cohort study of patients with severe aortic stenosis who underwent TAVR in the United States and South Korea from January 2015 to November 2019. PPM was defined as moderate (0.65-0.85 cm2/m2) or severe (<0.65 cm2/m2) at the indexed effective orifice area. The primary outcome was a composite of death, stroke, or rehospitalization at 1 year.ResultsAmong 1,101 eligible patients (533 Asian and 569 non-Asian), the incidence of PPM was significantly lower in the Asian population (33.6%; moderate, 26.5%; severe, 7.1%) than in the non-Asian population (54.5%; moderate, 29.8%; severe, 24.7%). The 1-year rate of the primary outcome was similar between the PPM and non-PPM groups (27.5% vs 28.1%; P = 0.69); this pattern was consistent between Asian (25.4% vs 25.2%; P = 0.31) and non-Asian (28.7% vs 32.1%; P = 0.97) patients. After multivariable adjustment, the risk for the primary outcome did not significantly differ between the PPM and non-PPM groups in the overall population (HR: 0.95; 95% CI: 0.74-1.21), in Asian patients (HR: 1.07; 95% CI: 0.74-1.55), and in non-Asian patients (HR: 0.86; 95% CI: 0.63-1.19).ConclusionsIn this study of patients with severe aortic stenosis who underwent TAVR, the incidence of PPM was significantly lower in Asian patients than in non-Asian patients. The 1-year risk for the primary composite outcome was similar between the PPM and non-PPM groups regardless of racial group. (Transpacific TAVR Registry [TP-TAVR]; NCT03826264)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号