 共查询到20条相似文献,搜索用时 62 毫秒
1.
A ruthenium(II) complex [Ru(PPh3)2(pytsc)2] {Hpytsc = pyridine‐2‐carbaldehydethiosemicarbazone, (C5H5N)C2(H)=N3‐N2(H)‐C1(=S)N1H} has been used as an ion carrier for the selective determination of silver(I) ions in solution. Silver(I) ion‐selective coated graphite based (CGE) and PVC polymeric membrane based (PME) electrodes exhibit Nernstian slope for silver(I) ions over a wide concentration range from 1.0 × 10−1 M to 5.0 × 10−6 M (with CGE) and 1.0 × 10−1 M to 2.0 × 10−5 M (with PME). The working pH range of these electrodes has been found to be from 1.2 to 7.2 for CGE and 2.2 to 6.5 for PME. The proposed CGE sensor exhibits better analytical features like sensitivity and selectivity towards different secondary ions in comparison to the corresponding PME with no interference from mercury(II) ions . These electrodes also act as indicator electrodes in potentiometric titration and have been successfully used for the determination of silver content in solution of real samples (1 gm dissolved in 100 mL of dilute nitric acid) such as silver ornaments and thin silver foils. Silver content determined by the use of ion selective electrode was found to vary in the concentration range from 1.20 x 10−2 M to 7.45 x 10−2 M and results were found to be comparable with those obtained from the traditional volumetric method of analysis. It is the first report of a metal‐ligand complex used as an ion carrier in ion selective electrode, which is selective for a metal ion other than the one used in the complex.  相似文献   

2.
《Electroanalysis》2017,29(2):566-577
Two novel carbon paste electrodes based on gentamicin‐reineckate (GNS‐RN)/multiwall carbon nanotubes (MWCNTs)/sodium tetraphenyl borate (NaTPB) or potassium tetraphenylborate (KTPB) for potentiometric determination of gentamicin sulfate were constructed. Our endeavors of lowering the detection limit for gentamicin ion‐selective electrodes were described. The paper focused on gentamicin carbon paste electrodes based on GNS‐RN as electroactive material, o ‐nitrophenyloctyl ether (o ‐NPOE) as plasticizer and incorporation of MWCNTs and lipophilic anionic additives (NaTPB and KTPB) which lower the detection limit of the electrodes showing best results for determination of gentamicin ion. The characteristics of the electrodes, GNS‐RN+NaTPB+MWCNTs (sensor 1) and GNS‐RN+KTPB+ MWCNTs (sensor 2), were measured, showing favorable features as they provided measurements of the potential with near‐Nernstian slopes of 29.6±0.3 and 29.1±0.3 mV/decade over the concentration range of 1.0×10−6–1.0×10−2 mol L−1 and pH ranges 3.0–8.2 and 3.0–8.0 in short response times (6.5 sec). Importantly, the electrodes had low detection limits of 3.0×10−7and 3.4×10−7 mol L−1 for the two sensors, respectively. The sensors showed high selectivity for gentamicin ion with respect to a large number of interfering species. The electrodes were successfully applied for the potentiometric determination of GNS ions in pure state, pharmaceutical preparations and human urine with high accuracy and precision. The results of this study were compared with some previously published data using other analytical methods.  相似文献   

3.
Novel PVC membrane (PME) and coated graphite (CGE) Cu2+‐selective electrodes based on 5,6,7,8,9,10‐hexahydro‐2H‐1,13,4,7,10‐benzodioxatriazacyclopentadecine‐3,11(4H,12H)‐dione are prepared. The electrodes reveal a Nernstian behavior over wide Cu2+ ion concentration ranges (1.0×10?7–1.0×10?1 M for PME and 1.0×10?8–1.0×10?1 M for CGE) with very low limits of detection (7.8×10?8 M for PME and 9.1×10?9 M for CGE). The potentiometric responses are independent of the pH of the test solutions in the pH range 2.7–6.2. The proposed electrodes possess very good selectivities for Cu2+ over a wide variety of the cations including alkali, alkaline earth, transitions and heavy metal ions. The practical utility of the proposed electrodes have been demonstrated by their use in the study of interactions between copper ions and human growth hormone (hGH) in biological systems, potentiometric titration of copper with EDTA and determination of copper content of a sheep blood serum sample and some other real samples.  相似文献   

4.
《Electroanalysis》2005,17(9):776-782
Three recently synthesized Schiff's bases were studied to characterize their ability as Cr3+ ion carrier in PVC‐membrane electrodes. The polymeric membrane (PME) and coated glassy carbon (CGCE) electrodes based on 2‐hydroxybenzaldehyde‐O,O′‐(1,2‐dioxetane‐1,2‐diyl) oxime (L1) exhibited Nernstian responses for Cr3+ ion over wide concentration ranges (1.5×10?6–8.0×10?3 M for PME and 4.0×10?7–3.0×10?3 M for CGCE) and very low limits of detection (1.0×10?6 M for PME and 2.0×10?7 M for CGCE). The proposed potentiometric sensors manifest advantages of relatively fast response and, most importantly, good selectivities relative to a wide variety of other cations. The selectivity behavior of the proposed Cr3+ ion‐selective electrodes revealed a considerable improvement compared to the best previously PVC‐membrane electrodes for chromium(III) ion. The potentiometric responses of the electrodes are independent of pH of the test solution in the pH range 3.0–6.0. The electrodes were successfully applied to determine chromium(III) in water samples.  相似文献   

5.
《Electroanalysis》2005,17(24):2260-2265
A new Cu(II) ion‐selective PVC membrane sensor based on 6‐methyl‐4‐(1‐phenylmethylidene)amino‐3‐thioxo‐1,2,4‐triazin‐5‐one (MATTO) as an excellent sensing material was developed. The electrode exhibits a Nernstian slope of 29.2±0.4 mV per decade over a very wide concentration range between 1.0×10?1 and 1.0×10?6 M, with a detection limit of 4.8×10?7 M (30.5 ng/mL). The sensor possesses the advantages of short conditioning time, fast response time (<10 s), and especially, very good selectivity towards transition and heavy metal, and some mono, di and trivalent cations. The proposed electrode was successfully applied to the determination of copper in wastewater of copper electroplating samples and as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA.  相似文献   

6.
Since to the best of our knowledge, there is no potentiometric sensors based on carbon paste electrodes were proposed for the potentiometric determination of molybdenum(VI) ion. In this study, 2,2′-(propane-1,3-diylbis(oxy))dibenzoic acid (PBODBA) was synthesized and used as modifier in the fabrication of carbon paste electrode (CPE) for the quantification of molybdenum(VI). The developed electrodes I and II showed hexavalent Nernstian response of 9.80±0.05 and 9.90±0.08 mV decade−1 over the concentration ranges of 1.0×10−7–1.0×10−3 and 1.0×10−8–1.0×10−3 mol L−1, respectively. The electrodes showed good selectivity for Mo(VI). The modified electrodes were applied for the determination of Mo(VI) concentration in masscuaje agricultural fertilizer and spiked juice extractions containing several metals.  相似文献   

7.
《Analytical letters》2012,45(4):683-695
Abstract

A highly selective and sensitive triiodide sensor based on a 2‐(((2‐(((E)‐1‐(2‐hydroxy phenyl) methylidine) amino) phenyl) imino) methyl) phenol with iodine (CTC) as membrane carrier was developed. The electrode revealed a Nernstian behavior over a very wide triiodide‐ion concentration range (5.0×10?8–1.0×10?2 M), and relatively low detection limit (3.0×10?8 M). The potentiometric response is independent of the pH of solution in the pH range of 3.0–10.0. The electrodes manifest advantages of low resistance, very fast response (<12 s), and most importantly, good selectivities relative to a wide variety of inorganic and organic anions, including iodide, bromide, chloride, fluoride, sulfite, sulfate, cyanide, thiocyanate, and acetate. In fact, the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for the triiodide ion. The proposed membrane sensor can be used for at least 6 months without any significant divergences in the potential. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion.  相似文献   

8.
Two new highly selective triiodide electrodes have been prepared using charge‐transfer complex of iodine with cryptand 222 as an electroactive ionophore and nitrophenyl octyl ether as a plasticizing agent. The electrodes showed Nernstian response to triiodide ions over a concentration range from 1.0 × 10?;2 — 7.9 × 10?;7 M and from 1.0 × 10?;2 — 1 × 10?;6 M with detection limits of 6.3 × 10?;7 and 7.9 × 10?;7 M for cryptand and its charge‐transfer complex with iodine, respectively. The response times (t95%) of the sensors were 10 and 5 s. The membrane could be used for more than 1 month without any divergence in potentials. The proposed sensors exhibited very high selectivity for triiodide ion over other anions, and could be used in a wide pH range ?2–10. These electrodes were successfully applied as an indicator electrode in potentiometric titration of copper in ore samples.  相似文献   

9.
《Electroanalysis》2002,14(24):1691-1698
Three different recently synthesized aza‐thioether crowns containing a 1,10‐phenanthroline sub‐unit (L1–L3) and a corresponding acyclic ligand (L4) were studied to characterize their abilities as silver ion ionophores in PVC‐membrane electrodes. Novel conventional silver‐selective electrodes with internal reference solution (CONISE) and coated graphite‐solid contact electrodes (SCISE) were prepared based on one of the 15‐membered crowns containing two donating S atoms and two phenanthroline‐N atoms (L1). The electrodes reveal a Nernstian behavior over wide Ag+ ion concentration ranges (1.0×10?5?1.0×10?1 M for CONISE and 5.0×10?8?4.0×10?2 M for SCISE) and very low limits of detection (8.0×10?6 M for CONISE and 3.0×10?8 M for SCISE). The potentiometric response is independent from pH of the solution in the pH range 3.0–8.0. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations. The electrodes can be used for at least 2 months (for CONISE) and 4 months for (SCISE) without any appreciable divergence in potentials. The electrodes were used as an indicator electrode in the potentiometric titration of Ag+ ion and in the determination of silver in photographic emulsions and in radiographic and photographic films.  相似文献   

10.
《Analytical letters》2012,45(8):1596-1609
Abstract

An original highly selective and sensitive PVC membrane sensor, working as a Fe(III) ion selective electrode and using 4‐amino‐6‐methyl‐3‐methylmercapto‐1,2,4‐triazin‐5‐one (AMMTO) as an ionophore, has been developed. This cetain sensor demonstrated the following performance; a linear dynamic range between 1.0×10?6 and 1.0×10?1 M with a near Nernstian slope of 19.4±0.5 mV per decade; a detection limit of 6.8×10?7 M; characteristically, the best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 65.5% nitrophenyl octyl ether, 2% sodium tetraphenyl borate and 2.5% AMMTO. Furthermore, the potentiometric response of the developed electrode is independent of the solution pH in the range of 2.2–4.8. The sensor possesses the advantages of short conditioning time, fast response time (<15 s) and, especially, great selectivity towards transition and heavy metal ions and some mono, di‐ and trivalent cations. The electrode can be used for at least 9 weeks without any considerable potential divergence. It was effectively used as an indicator electrode in the potentiometric titration of Fe(III) ions with EDTA and the direct determination of Fe3+ in different water samples.  相似文献   

11.

In this work, two newly sensitive and selective Al(III)-modified carbon paste electrodes (MCPEs) were developed based on diphenylcarbazone (DPC) modifier mixed with tricresyl phosphate plasticizer and either graphite powder (electrode I) or graphite powder mixed with graphene (electrode II). The potentiometric performance characteristics of the two electrodes were scrutinized and discussed. The proposed sensors showed a high electrochemical response in the linear concentration range of 1.0 × 10−6 to 1.0 × 10−2 mol L−1 with a good Nernstian slopes of 20.12 ± 0.30 mV decade−1 and 20.63 ± 0.66 mV decade−1 and limits of detection of 9.0 × 10−7 and 8.5 × 10−7 mol L−1 for electrode (I) and electrode (II), respectively. Both electrodes showed a fast response time and reasonable thermal stability. The potentiometric response of the DPC-based electrodes was independent on the pH of the tested solutions in ranges of 2.5–5 and 2.5–5.5 for electrode (I) and electrode (II), respectively. The two electrodes can be also used in partially non-aqueous medium containing up to 20% (v/v) acetone or methanol with no significant changes in the working concentration ranges or the slopes. The proposed electrodes showed fairly good discriminating ability toward Al(III) ions in comparison with many other metal ions. The electrodes were applied successfully for Al(III) ions determination in drainage water, spiked tap water and pharmaceutical preparation samples. Furthermore, the electrode surfaces were characterized using energy-dispersive X-ray (EDX) and scanning electron microscopic (SEM) as surface characterization techniques and Fourier Transform Infrared (FT-IR) technique to confirm the interaction between Al(III) and DPC.

  相似文献   

12.
Molecularly imprinted polymers (MIP) were used as potentiometric sensors for the selective recognition and determination of chlormequat (CMQ). They were produced after radical polymerization of 4‐vinyl pyridine (4‐VP) or methacrylic acid (MAA) monomers in the presence of a cross‐linker. CMQ was used as template. Similar non‐imprinted (NI) polymers (NIP) were produced by removing the template from reaction media. The effect of kind and amount of MIP or NIP sensors on the potentiometric behavior was investigated. Main analytical features were evaluated in steady and flow modes of operation. The sensor MIP/4‐VP exhibited the best performance, presenting fast near‐Nernstian response for CMQ over the concentration range 6.2×10−6–1.0×10−2 mol L−1 with detection limits of 4.1×10−6 mol L−1. The sensor was independent from the pH of test solutions in the range 5–10. Potentiometric selectivity coefficients of the proposed sensors were evaluated over several inorganic and organic cations. Results pointed out a good selectivity to CMQ. The sensor was applied to the potentiometric determination of CMQ in commercial phytopharmaceuticals and spiked water samples. Recoveries ranged 96 to 108.5%.  相似文献   

13.
《Electroanalysis》2005,17(20):1865-1869
A novel anion‐selective PVC membrane electrode based on bis‐[(3‐ferrocenyl)‐(2‐crotonic acid)] copper(II) complex [Cu(II)‐BFCA] as neutral carrier is described, which demonstrates excellent potentiometric response characteristics toward thiocyanate ion and anti‐Hofmeister selectivity sequence in following order: SCN?>I?>ClO >Sal?>Br?>NO >Cl?≈NO >SO >SO . The electrode shows a near‐Nernstian response for thiocyanate ion in a wide range of 9.0×10?7–1.0×10?1 M with a detection limit 6.8×10?7 M and a slope of ?59.1 mV/decade in pH 5.0 of phosphate buffer solution at 20 °C. The influences of lipophilic cationic and anionic additives on the response properties of the electrode were investigated. High sensitivity and wide linear dynamic range were observed for the electrode in the presence of hexadecyltrimethylammoniumborate (HTAB) as a lipophilic cationic additive. The electrode was successfully applied to the determination of thiocyanate ion in waste water and human saliva.  相似文献   

14.
The construction and performance characteristics of pentoxifylline selective electrodes were developed. Two types of electrodes: plastic membrane I and coated wire II were constructed based on the incorporation of pentoxifylline with phosphotungstic acid (PTA). The influence of membrane composition, kind of plasticizer, pH of the test solution, soaking time, and foreign ions on the electrodes was investigated. The electrodes showed a Nernstain response with a mean calibration graph slope of 56.77 ± 0.19 and 55.76 ± 0.71 mV decade‐1 at 25 °C for electrode I and II respectively, over pentoxifylline concentration range from 1.0 × 10‐5‐1.0 × 10‐2 and 9.0 × 10‐6‐1.0 × 10‐2 mol L‐1, with detection limits 4.89 × 10‐6 and 3.90 × 10‐6 mol L‐1 for electrode I and II, respectively. The pH range of the constructed electrodes was 4‐6. Interferences from common cations, alkaloids, sugars, amino acids and drug excipients were reported. The results obtained by the proposed electrodes were also applied successfully to the determination of the drug in its pharmaceutical preparations and biological fluids.  相似文献   

15.
《Electroanalysis》2017,29(3):821-827
An all‐solid‐state polymeric membrane Ca2+‐selective electrode based on hydrophobic octadecylamine‐functionalized graphene oxide has been developed. The hydrophobic composite in the ion‐selective membrane not only acts as a transduction element to improve the potential stability for the all‐solid‐state Ca2+‐selective electrode, but also is used to immobilize Ca2+ ionophore with lipophilic side chains through hydrophobic interactions. The developed all‐solid‐state Ca2+‐selective electrode shows a stable potential response in the linear range of 3.0×10−7–1.0×10−3 M with a slope of 24.7±0.3 mV/dec, and the detection limit is (1.6±0.2 )×10−7 M (n =3). Additionally, due to the hydrophobicity and electrical conductivity of the composite, the proposed all‐solid‐state ion‐selective electrode exhibits an improved stability with the absence of water layer between the ion‐selective membrane and the underlying glassy carbon electrode. This work provides a simple, efficient and low‐cost methodology for developing stable and robust all‐solid‐state ion‐selective electrode with ionophore immobilization.  相似文献   

16.
《Electroanalysis》2004,16(12):1009-1013
A novel ion‐selective polymeric membrane sensor based on pyrylium‐4,4‐(1,4‐phenylen) bis[2,6‐bis(2‐naphthyl)]‐bis[tetrafluoroborate] (PBGNB) as an excellent sensing material is successfully developed. The electrode possesses the advantages of a very low detection limit (5.0×10?8 M), a wide working concentration range (1.0×10?8?1.0×10?1 M) and specially, a high sulfate selectivity over most common organic and inorganic anions. The sensor displays Nernstian behavior (slope of 29.5±0.5 mV per decade) in a wide pH range (3.0–8.5). It shows a short response time in the whole concentration range (ca. 10 s). The electrode was used as an indicator electrode in the potentiometric titration of sulfate ions with barium ions. The proposed sensor was successfully applied to the direct determination of salbutamol sulfate and paromomycin sulfate.  相似文献   

17.
Vitamin B1‐selective electrodes with PVC membrane were developed that contain ion associates of vitamin B1 with an inorganic anion, BiI4?, and an organic anion, brilliant yellow, as electrode‐active substances. The linearity ranges of the electrode function are 1.0×10?5–1.0×10?2 and 1.0×10?4–1.0×10?2 M, the electrode function slopes are 33.0±1.0 and 33.1±1.1 mV decade?1, the detection limits are 5.5×10?6 and 8.3×10?5 M for BiI4? and brilliant yellow respectively. The working range of pH is 5–12. The efficiency of the use of electrodes for the vitamin B1 content control in multivitamin pharmaceutical preparations was shown by direct potentiometry and potentiometric titration methods.  相似文献   

18.
The 3‐amion‐5‐mercapto‐1,2,4‐triazole cobalt(II) [Co(II)AMETR] was used as a new carrier for preparing polymeric membrane selective sensor which exhibited high affinity for iodide ion. The effects of membrane composition, pH, the influence of lipophilic ion additives and plasticizer on the response characteristics of the sensor were investigated. The sensor showed a near Nernstian slope of ?56.6 mV/decade for I? ion over a wide concentration range from 8.5×10?7 to 1.0×10?1 M with a low detection limit of 5.1×10?7 M. The sensor has a fast response time and could be used over a wide pH range of 2–8. The response mechanism is discussed in view of the AC impedance technique. The sensor was successfully applied to direct determination of iodide content in environmental water samples and mouth wash samples.  相似文献   

19.
《Electroanalysis》2005,17(17):1534-1539
The construction, performance, and applications of a novel ytterbium(III) sensor based on N‐(2‐pyridyl)‐N′‐(2‐methoxyphenyl)‐thiourea (PMT), as an excellent carrier, in plasticized poly(vinyl chloride) PVC matrix, is described. The influences of membrane composition and pH on the potentiometric response of the sensor were investigated. The sensor exhibits a nice Nernstian response for Yb(III) ion over a wide concentration range of 4 decades of concentration (1.0×10?6–1.0×10?2 M), and a detection limit of 5.0×10?7 M. The response time of the electrodes is between 8 and 10 s, depending on the concentration of ytterbium(III) ions. The proposed sensor can be used for about 8 weeks without any considerable divergence in potential. The sensor revealed very good selectivity for Yb(III) in the presence of several metal ions. The best performance was observed for the membrane containing; 30% PVC, 59% o‐nitrophenyloctyl ether (NPOE) as solvent mediator, 7% PMT, and 4% sodium tetraphenyl borate (NaTPB). It was successfully applied as indicator electrodes in the potentiometric titration of Yb(III) with EDTA and for the determination of fluoride ion in two mouth wash formulations. The proposed La(III) sensor was found to work well under laboratory conditions. It was also used as an indicator electrode in titration of a 1.0×10?4 M of Yb(III) with a standard EDTA solution (1.0×10?2 M). It was also used for determination of Yb(III) ion in Xenotime .  相似文献   

20.
Two novel potentiometric azide membrane sensors based on the use of manganese(III)porphyrin [Mn(III)P] and cobalt(II)phthalocyanine [Co(II)Pc] ionophores dispersed in plasticized poly(vinyl chloride) PVC matrix membranes are described. Under batch mode of operation, [Mn(III)P] and [Co(II)Pc] based membrane sensors display near‐ and sub‐Nernstian responses of ?56.3 and ?48.5 mV decade?1 over the concentration ranges 1.0×10?2?2.2×10?5 and 1.0×10?2?5.1×10?5 mol L?1 azide and detection limits of 1.5×10?5 and 2.5×10?5 mol L?1, respectively. Incorporation of both membrane sensors in flow‐through tubular cell offers sensitive detectors for flow injection (FIA) determination of azide. The intrinsic characteristics of the [Mn(III)P] and [Co(II)Pc] based detectors in a low dispersion manifold show calibration slopes of ?51.2 and ?33.5 mV decade?1 for the concentration ranges of 1.0×10?5?1.0×10?2 and 1.0×10?4?1.0×10?2 mol L?1 azide and the detection limits are1.0×10?5 and 3.1×10?5 mol L?1, respectively. The detectors are used for determining azide at an input rate of 40–60 samples per hour. The responses of the sensors are stable within ±0.9 mV for at least 8 weeks and are pH independent in the range of 3.9?6.5. No interferences are caused by most common anions normally associated with azide ion.  相似文献   