首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
王珏  杨宁 《化工学报》2017,68(7):2667-2677
能量最小多尺度(energy-minimization multi-scale,EMMS)方法已经被应用于气液体系中群平衡(population balance model,PBM)模型的改进。EMMS模型可计算气泡破碎聚并过程的能量,进而获得聚并速率的修正因子。应用这一模型对高气速鼓泡塔进行了模拟计算,并进一步对比了均一尺径模型、CFD-PBM模型以及CFD-PBM-EMMS模型的模拟结果与实验数据。结果表明,在高表观气速条件下,基于EMMS方法的群平衡模型可以更加准确地预测鼓泡塔中不同高度的气泡尺径分布和轴向液速,同时提高了对整体气含率和局部气含率的模拟准确性。在表观气速为0.16 m·s-1和0.25 m·s-1时,CFD-PBM-EMMS模型对气泡尺径分布的预测精度更高,同时整体气含率模拟的相对误差下降为5%和15%,局部气含率模拟平均相对误差下降为8%和17%。  相似文献   

2.
In this work, the influence of structured packing on gas holdup in gas-liquid-solid dispersions has been studied. The experiments were carried out in an empty column and in column containing structured packing operating under identical conditions. Glass beads and silicon carbide particles were used as the solid material and the volumetric fraction of solids was varied from 0% to around 10%. The liquid viscosity was strongly modified using water, CMC solution and glycerol. The experimental results obtained with both columns were compared with previous results obtained in two-phase bubble columns. The influence of structured packing on the total gas holdup for different superficial gas velocities was found to be similar with and without suspended solids. Therefore, the results obtained in this work were analysed on the basis of correlations derived earlier for gas-liquid dispersions. Excepting the results obtained with glycerol, these correlations can predict the gas holdup of three-phase bubble columns with reasonable accuracy.  相似文献   

3.
Unsteady gas-liquid flows in bubble columns are comprised of various flow processes occurring with varying length and time scales and govern mixing and transport processes. In the present work, we have characterized dynamic and time-averaged properties of gas-liquid flows in rectangular bubble columns using conductivity probes. The development of a single-tip conductivity probe, data processing methodology, and photographic validation procedure is discussed in detail. The effect of superficial gas velocity and aerated liquid height-to-width (H/W) ratio on voidage fluctuations and time-averaged gas holdup was investigated. The experimental data presented here can help in understanding the dynamics of various flow processes and validating computational fluid dynamics based models.  相似文献   

4.
Gas holdup and pressure loss were measured for various gas-liquid systems in a batch, multistage bubble column. Experimental results show that the use of screen plates (α = 0.64) considerably increases the gas holdup but introduces a significant pressure loss for the two-phase mixture. The pressure loss was found to be independent of physical properties of the mixture, and predictable either from the modified separated flow model (Chen et al., 1986) or from the kinetic energy loss based on the liquid circulation velocity.  相似文献   

5.
刘鑫  张煜  张丽  靳海波 《化工学报》2017,68(1):87-96
目前,多数文献报道了冷态加压湍动鼓泡塔内流动特征,并且通过实验数据回归相关经验关联式。然而,此类关联式适用范围有限,难以直接外推到工业鼓泡塔反应器条件。因此,在FLUENT平台上建立了基于气泡群相间作用力的、动态二维加压鼓泡塔计算流体力学模型。通过数值模拟考察了操作压力为0.5~2.0 MPa,表观气速为0.20~0.31 m·s-1,内径0.3 m鼓泡塔内流场特性参数分布,并且与冷态实验数据进行比较。结果表明,采用修正后的气泡群曳力模型、径向力平衡模型以及壁面润滑力模型描述气泡群相间作用力,能够较为准确地反映平均气含率和气含率径向分布随操作压力和表观气速变化的规律。  相似文献   

6.
Mean gas holdup, lateral distribution of gas holdup and axial mixing of gas and liquid were measured in bubble columns of 12 and 19cm i.d. The lateral distribution of gas holdup was strongly dependent on the flow regimes in the column. The axial mixing of liquid in the homogeneous bubble flow regime was much smaller than that in the heterogeneous bubble flow regime, and was not expressed by existing correlations. The axial mixing of liquid in the homogeneous bubble flow and the intermediate flow regime was simulated with a flow model based on the lateral distribution of buoyancy force and the effective viscosity. The axial mixing of gas was larger than that of liquid.  相似文献   

7.
采用改进的Pavlov管测定鼓泡塔中的液相局部流速,采用电导探针方法测定气含率分布,测定了3种塔径(D200mm,D500mm,D800mm)、不同空塔气速下的流速三维分布和气含率分布。  相似文献   

8.
Fibre type and mass fraction have significant effects on gas holdup in gas‐liquid‐fibre bubble columns. An experimental study is introduced to identify a parameter that simultaneously characterizes the fibre type and mass fraction effects on gas holdup in gas‐liquid‐fibre bubble columns. This parameter satisfies the following condition: when this parameter is constant, the gas holdup trend in different fibre suspensions is generally similar at most operating conditions. A method is proposed to identify a characterization parameter by combining the crowding factor and fibre number density. The identified parameter is Ic=1n(Nc0.8Nf0.2). This parameter can be used to model gas holdup in gas‐liquid‐fibre bubble columns and quantitatively compare the fibre effects in different fibre suspensions.  相似文献   

9.
Including internals in bubble columns is known to enhance the gas holdup. In this paper, a method to achieve this objective substantially has been proposed via the use of vibrating helical spring internals. Experimental observations on effect of vibrating internals such as vibrating helical springs on gas holdup in bubble columns are presented. Effects of superficial gas velocity, H/D ratio (height of the static liquid to column diameter ratio), volume fraction of helical springs, and thickness of the helical spring wires on hydrodynamics parameters are studied. Increase in gas holdup up to 135% is observed by using vibrating helical spring internals in bubble columns compared to bubble columns without internals. This method offers a simple, cost‐effective, and easy way to enhance gas holdup even at high gas fluxes. It has been reported that this enhancement stems from the fact that the vibrating springs breakup the gas into fine bubbles, which effectively reduces their rise velocity and enhances their average residence time in the liquid column.  相似文献   

10.
11.
本文比较了目前常用的几种分布器,通过照像法观察了三种分布器(单孔板、多孔板和烧结金属板)上的气泡形成过程,然后测定了这三种分布器的于板压降和湿板压降,并就它们对水力学条件的影响进行了考察。其结果对鼓泡床内分布器的设计具有一定的参考价值。  相似文献   

12.
The hydrodynamic behavior of a single‐stage tapered bubble column using an air‐water two‐phase system has been studied. The experimental results indicate that the holdup increases with increasing superficial gas velocity and bubble slip velocity, while it remains constant with increasing superficial liquid velocity. The gas flow rate has a subtle effect on pressure drop owing to the dynamic pressure recovery stemming from the increase in flow area in the axial direction. The results further suggest that the tapered bubble column shows higher holdup with lower energy dissipation than the conventional bubble columns under similar hydrodynamic conditions. The experimental values of the holdup are in excellent agreement with the well‐known Akita and Yoshida correlation available in the existing literature. Also, the performance of the tapered system has been shown to be much better than that of conventional columns under similar conditions in water/alkaline scrubbing of fly ash and SO2 either alone or in combination.  相似文献   

13.
Experimental measurements for the axial and radial variations in gas holdup, axial and radial dispersion coefficients, volumetric gas-liquid mass transfer coefficient and liquid phase circulation velocity in a cone of a large diameter (122 cm) jet bubble column are presented. Two diameters of the inlet nozzle, namely 10.16 cm and 15.24 cm, three superficial gas velocities (based on cylinder diameter), 3 cm/sec, 6 cm/sec and 8 cm/sec and two superficial liquid velocities, 0.3 cm/sec and 0.6 cm/sec, are examined. The experimental data are obtained for two different bed heights.

The experimental data showed significant axial and radial variations in the gas holdup. The volumetric average gas holdup was higher at higher gas velocity and larger nozzle diameter and somewhat higher at lower liquid velocity. The axial dispersion was high while the radial dispersion was low. The volumetric gas-liquid mass transfer coefficient was larger at higher gas velocity and larger nozzle diameter. The liquid recirculation begins only at the upper end of the cone. In general, experimental data indicate that a jet bubble column provides a high degree of mixing and transport rates.  相似文献   

14.
采用电导探针测定了冷态鼓泡塔中不同气速下的气泡直径及气含率的轴向分布,考察了分布板对鼓泡塔操作性能的影响.结果表明:随着开孔率的减小,从均匀鼓泡区到过渡区的转变提前;在均匀鼓泡区,开孔率对气泡直径影响较小;在过渡区,开孔率大的分布器形成的稳定气泡直径较小、气含率较大;分布板开孔直径越大,形成的初始气泡直径越大,但对轴向气泡直径分布的影响仅限于分布器区.包含分布器影响的气泡直径经验关联式为d/D=140.2Bo-0.5Ga-0.12Fr0.099(h/D)-0.15T-0.34(0.5 cm/s<ug<7 cm/s).  相似文献   

15.
In many gasliquid processes, the initial bubble size is determined by a series of operation parameters along with the sparger design and gasliquid flow pattern. Bubble formation models for variant gasliquid flow pat terns have been developed based on force balance. The effects of the orientation of gasliquid flow, gas velocity, liquid velocity and orifice diameter on the initial bubble size have been clarified. In ambient airwater system, thesultable gasllquid flow pattern is important to obtain smaller bubbles under the low velocity liquid crossflow con ditions with stainless steel spargers. Among the four types of gasliquid flow patterns discussed, the horizontal orifice in a vertically upward liquid flow produces the smallest initial bubbles. However the orientation effects of gas and liquid flow are found tobe insgnifican whenliq.uid velocity is.higher than. 3.2 m;sa or theorifice diameter is small enough.  相似文献   

16.
在内径为0.38 m的鼓泡塔中采用双电导探针法对不同通气速率下的气泡尺寸分布和局部气含率进行了实验研究,分析了气泡尺寸的概率密度分布。结果表明:气泡尺寸随轴向高度的增加而增大,随径向距离增加而减小;鼓泡塔中气液流动可分为过渡流域和充分发展流域,在过渡流域气含率随轴向高度增加而增大,在充分发展流域气含率趋于均值,径向局部气含率分布呈抛物线型下降。高气速下气泡尺寸概率密度分布比低气速下宽,且随轴向高度的增加分布变宽。  相似文献   

17.
液体循环流动是多级鼓泡塔重要流体力学特征之一,文中在内径为282 mm,高2000 mm的鼓泡塔内,采用不同类型的筛板将普通鼓泡塔分割成双级气液鼓泡塔.采用Pavlov管测液速的方法考察了不同筛板、不同表观气速下该鼓泡塔中上下二侧的液体速度分布.根据实验结果得出了液体速度在塔中心处最大,且与表观气速有关,随着表观气速的...  相似文献   

18.
基于径向力平衡的鼓泡塔二维流体力学模型   总被引:1,自引:2,他引:1       下载免费PDF全文
李兆奇  王丽军  管小平  成有为  李希 《化工学报》2014,65(11):4222-4230
提出了一种鼓泡塔二维轴对称流体力学模型,模型中将气泡所受的升力以及湍动扩散力作为形成塔内气含率稳定分布的主要机制.采用Fluent 6.3流体力学软件求解模型,能得到稳定的二维流场,气含率与液速分布与实验值吻合良好,模型能准确反映表观气速(0.12~0.62 m·s-1)以及塔径(ø200 mm、ø500 mm、ø800 mm)对流型的影响.利用该模型对更大直径鼓泡塔的流动参数进行了预测,结果与文献给出的经验关联式相符.  相似文献   

19.
Experimental measurement of gas holdup was carried out in a medium-size gas-liquid-liquid bubble column with a multiple nozzle sparger plate using air, water and organic liquids. It was found that the fractional holdup depends on gas velocity, liquid properties, phase inversion in the liquid mixture as well as spreading coefficient of the organic liquid. In the presence of a liquid with a negative spreading coefficient the holdup is a minimum at the phase inversion point. but the reverse is true for a liquid with a positive coefficient of spreading. Observed bubble characteristics have been discussed. Correlations for gas holdup have been developed for different ranges of liquid composition.  相似文献   

20.
Local bubble behaviours were investigated in three bubble columns with different diameters of 200, 400 and 800 mm. By means of a novel single‐tip optical fibre probe employing laser Doppler technique, the local gas holdup, bubble frequency, bubble size and velocity were measured simultaneously at different locations of the columns. Measurements were performed in air‐water system at superficial gas velocities up to 90 mm/s. The averaged profiles and instantaneous measurements were analyzed and compared for different columns. The presence of a coherent gross circulation structure spanning the entire column diameter in the larger column rather than a pair of symmetrical circulation cells observed in the smaller columns has been confirmed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号