首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Newly synthesized organoboron compounds – 4-octyloxyphenylboronic acid (OPBA) and pinacol ester of 2,4,6-trifluorophenylboronic acid (PE-PBA) – were applied as Lewis acid receptors of fluoride anions. Despite enhanced selectivity, the polymer membrane electrodes containing the lipophilic receptor OPBA exhibited non-Nernstian slopes of the responses toward fluoride ions in acidic conditions. Such behavior was explained by the lability of the B–O bond in the boronic acids, and the OH/F exchange at higher fluoride content in the sample solution. In consequence, the stoichiometry of the OPBA–fluoride complexes in the membrane could vary during the calibration, changing the equilibrium concentration of the primary anion in membrane and providing super-Nernstian responses. The proposed mechanism was supported by 19F NMR studies, which indicated that the fluoride complexation proceeds more effectively in acidic solution leading mainly to PhBF3 species. Finally, the performances of the membranes based on the phenylboronic acid pinacol ester, with a more stable B–O bond, were tested. As it was expected, Nernstian fluoride responses were recorded for such membranes with worsened fluoride selectivity.  相似文献   

2.
Basic observations leading to the successful application of magnesium ion-selective electrodes for the automated determination of ionized magnesium in undiluted serum are discussed. The principles of the method are described and the first numerical results are reported.  相似文献   

3.
A new solid state fluoride ion selective electrode composed of 70% Ag2S, 10% Cu2S and 20% CaF2 has been developed. An analytically useful potential change occurred, from 1 × 10−6 to 1 × 10−1 M fluoride ion. The slope of the linear portion (1 × 10−1-1 × 10−5 M) was about 26 ± 2 mV/10-fold concentration changes in fluoride. It was found that pH change between 1 and 8 had no effect on the potential of the electrode. There was no interference of most common cations such as K+, Na+, Ca2+ and Mg2+ and anions such as Cl, NO3, SO42− and PO43−. The lifetime of the electrode was more than 2 years, when used at least 4-5 times a day, and the response time was about 60 s.The measurements were made at constant ionic strength (0.1 M NaNO3) and at room temperature. This electrode has been used for the determination of fluoride ion in Ankara city tap water and in bottled spring water using standard addition method. The validation of the electrode has been made with a commercial fluoride ion selective electrode (Orion) and high consistency was obtained.  相似文献   

4.
Battery-powered complementary metal-oxide semiconductor (CMOS) electronic devices are used to develop computerized instrumentation based on an ion-selective electrode for environmental monitoring in the field. The development of CMOS-based instrumentation for the determination of fluoride in drinking water, river water, lake water and sea water is described. The instrument is portable and completely field-programmable. Under software control, the equilibrium potential and fluoride concentration, based on a double standard-addition method, are calculated. The associated temperature, date and time form part of the data-logging record. Data obtained in the field are shown to compare satisfactorily with those obtained on samples which were stored and returned to the laboratory for examination by conventional mains-powered instrumentation. Accuracy is good and precision is only slightly poorer than that of mains-powered laboratory instrumentation.  相似文献   

5.
Alkali-free lead phosphate glasses containing silver chloride have been developed for anion responsive sensors. From measurements of the final glass compositions by electron probe microanalysis, it became clear that some of chloride ions in the glass bulk were not volatilized during the glass melting process. Compared with phosphate glasses containing silver oxide, the new glass electrodes containing silver chloride could respond more rapidly, although the response behaviour for anionic species were similar. From the electrode potential vs. time curve for the anionic species, the potential rapidly reached equilibrium when these concentrations varied from 10?5 to 10?2 M. The response times, t95, to thiocyanate of the new glass electrode and the phosphate glass electrode containing silver oxide were 30 and 110 s, respectively. Moreover, the response time required for an initial potential change with a concentration jump of thiocyanate with the new glass electrode was found to be independent of the membrane thickness within about 2 mm and of the measuring temperature between 15 and 40°C. It is concluded that the diffusion process of species such as silver ion in the glass bulk does not take part in the initial part of the response behaviour.  相似文献   

6.
The response of ion-selective electrodes with a membrane of polyacrylamide (PAA) coupled to acyclic poly(oxyethylene) neutral carriers to lithium, sodium, potassium, magnesium and barium ions in propylene carbonate (PC) was investigated. Tetraethylene glycol monododecyl ether (POE4) and hexaethylene glycol monododecyl ether (POE6) were used as the acyclic poly(oxyethylene). Both the PAA-POE4 and the PAA-POE6 electrodes showed a more rapid dynamic response in PC than that in acetonitrile. Nernstian responses to lithium, magnesium and barium ions were obtained with the PAA-POE4 electrode. The selectivity coefficients, logkBa2+,Mx+, for lithium, sodium, potassium and magnesium ions vs. barium ion obtained in PC with the PAA-POE4 electrode were 3.6, 0.23, 0.02 and 1.1, respectively. The PAA-POE4 electrode was applied to obtain the successive formation constants of the barium ion in PC with N, N-dimethylacetamide (DMA). From the successive formation constants obtained in PC-rich solutions, the Gibbs free energies of transfer of the barium ion from PC to DMA and to PC-DMA mixtures were calculated. The electrode was also used to obtain directly the Gibbs free energies of transfer of the barium ion from PC to PC-DMA mixtures. The calculated values of the free energies were in good agreement with the values obtained experimentally, suggesting that the electrode responded to variations in solvation energy for the barium ion.  相似文献   

7.
Vascular endothelial growth factor (VEGF) is a cytokine and endothelial cell (EC) mitogen that has been studied for its role in angiogenesis of malignant tumors. Elevated quantities of VEGF in the serum and plasma of patients have been correlated with the presence of cancer and metastasis. Since VEGF induces hyperpermeability of EC monolayers, this protein can be detected in vitro with a whole cell-based biosensor. This biosensor consists of a confluent monolayer of human umbilical vein endothelial cells (HUVECs) attached to a cellulose triacetate (CTA) membrane of an ion-selective electrode (ISE). Previous studies regarding this biosensor have shown that when the biosensor was exposed to a model toxin, such as histamine, the response of the biosensor served as an indirect measurement of the presence of histamine. Similarly, the biosensor responds to the presence of VEGF, but is much more sensitive because VEGF is known to be 50,000-fold more potent than histamine when inducing EC hyperpermeability. The ISE response increased with increasing VEGF concentration. Since lower concentrations required more exposure time, the detection limit was established as a function of exposure time (2–10 h). The practical applicability of the biosensor was also established with cultured human melanoma cells WM793 (nonmetastatic) and 1205LU (metastatic). The resultant change in the potential values revealed significant production of VEGF from the 1205LU cells. A VEGF ELISA was performed to confirm the VEGF concentration in each sample. The biosensor closely predicted the concentrations determined through the ELISA. These results support the use of a cell-based ISE as a quick screening method for the presence of VEGF.  相似文献   

8.
Ion-selective potentiometry enjoys practical utility as a simple analytical technique to measure ionic constituents in complex samples. Advances in the field have improved the selectivity and decreased the detection limit of ion-selective electrodes (ISEs) by orders of magnitude such that trace analysis in micro and nanomolar concentrations is now possible with potentiometric sensors. This tutorial reviews the fundamental principles of ion-selective potentiometry, describes the practical considerations involved in the use of these sensors to measure real samples, and discusses the statistical evaluation of experimental results compared with alternative analytical techniques.  相似文献   

9.
Ion-selective PVC membrane electrodes for the peripherial muscle relaxants pancuronium (PAN), tubocurarine (TUB), gallamine (GAL) and succinylcholine (SUC) are presented. The preparation of the electrode membranes contaimng ion pairs of the muscle relaxants with two different anionic counter ions, dipicrylaminate (DPA) and tetraphenylborate (TPB), are reported. The detection limits for all electrodes were ca. 10?6 mol 1?1 at physiological pH values and the measured slopes were dose to the values theoretically expected. Changes in the detection limits and the slopes of the electrodes in the pH range 2.5–11.0 were found to be due to reversible changes in the protonation state of the amine groups of the muscle relaxant (TUB) or the counter ion (DPA). The PAN-TPB and PAN-DPA ion-pair complexes were observed to have a bettet stability than those formed with TUB, GAL and SUC. The observed selectivity coefficients of the PAN-TPB electrodes were 10?0.3 towards TUB and 10?1.8 towards GAL.  相似文献   

10.
The use of solid contact flow-through calcium-selective electrodes as potentiometric detectors in flow-injection analysis and non-suppressed ion chromatography is discussed. Owing to the high selectivity of the membrane electrode based on tetratolyl-m-xylylenediphosphine dioxide, it can be used to monitor trace amounts of calcium ions in the presence of a 100-fold excess of alkali metal, ammonium and magnesium ions. The detection limit is about 1 × 10?6 M. The composition and thickncss of the calcium selective membrane influence both the detection limit and selectivity of the electrode. The sensitivity of this potentiometric detector in ion chromatography relative to alkaline earth and heavy metals is significantly higher than that of a commercial conductivity detector.  相似文献   

11.
This study was carried out to determine fluoride in drinking water and in urine of adolescents, ages 15-20 years, living in Northern Chihuahua Mexico. Participants are from a cross-sectional study on health effects of chronic fluoride exposure from drinking water. A total of 201 participants (106 female and 95 male) in the study were recruited from three counties. Samples of drinking water of each county were collected and analyzed using the U.S. EPA Fluoride Ion-Selective Method. Statistically significant difference of fluoride content in water was found among the three counties of recruitment (Cd. Juarez; 0.3 mg/L, Samalayuca, 1.0 mg/L, and Villa Ahumada, 5.3 mg/L). Fluoride content in wells and tap water samples of Villa Ahumada ranged from 5.0 to 5.7 mg/L. Fluoride content of these samples was above the level permitted by Mexican regulations. The fluoride content in bottled water obtained from local stores in Villa Ahumada ranged from 0.3 to 3.7 mg/l.Fluoride in urine samples of each participant was also analyzed using the U.S. EPA Ion-Selective Method. The mean fluoride urine concentration (reported in mg/g creatinine) in adolescents living in these counties was 0.792±0.39, 1.33±0.67 and 2.22±1.16 (Cd. Juarez, Samalayuca and Villa Ahumada), respectively. The high fluoride urinary levels found in participants from Villa Ahumada may be associated to the high fluoride level (5.3 mg/L) in dinking water.The accuracy of measurements was assessed with reference materials in water and in urine. Mean fluoride recovery was 99.0% and 99.6% in water and in urine, respectively. The levels obtained were within the assayed 5% confidence levels.  相似文献   

12.
The manufacture and evaluation of a novel sensor built with a composite material, highly selective to nitrate ions using doped polypyrrole as a recognition agent, are presented. When the ratio of recognition agent to graphite was optimized at 1:1, and the sensitivities found closely approached nernstian behavior. The stability times attained were less than 14 min with response times also below 20 s. Batch characterization of the sensor displayed a sensitivity of 57.1 mV/decade of nitrate ion activity () and a detection limit of 5.37 × 10−5 M, which are comparable to those reported for commercial sensors. Evaluation of the selectivity coefficients showed high affinity to nitrate ion, superior to that of commercial sensors and others reported in the literature. The composite material gives the sensor a prolonged service life with the added capability of allowing the regeneration of its active surface. Coupling the sensor and a solid state, composite-type, reference electrode to a flow injection analysis system (FIA) permitted to achieve an effective overall assessment of the system. A nitrate determination test was conducted on real samples. A comparison of the results obtained, either with stationary measurements or with FIA, indicated that there were no significant differences from the values from manufacturer’s specifications.  相似文献   

13.
A procedure to estimate the uncertainty of measurement applied to the fluoride determination of waters and wastewaters matrices by selective electrode potentiometry was implemented based on Eurachem Guide. The major sources of uncertainty were identified as the calibration standard solutions, fluoride concentration obtained by potential interpolation of the regression line and the precision. However the relative uncertainties depend on the anion concentration levels. The methodology proposed was presented to two fluoride concentration levels that are in the range of surface water samples (C sample=1.12 mgF l−1) and of wastewater matrices (C sample=101.4 mgF l−1). The expanded uncertainties calculated were 0.40 and 9.1 mg l−1 for low and high concentration levels, respectively, using the reproducibility uncertainty as precision evaluation. The relative expanded uncertainty was around ±10% for the highest concentration, which can be considered acceptable for the ion selective electrode potenciometric methods and ±36% for the lowest concentrations. In this case the sample fluoride content is very close to the limit of quantification which has a relative uncertainty of about ±30%. If the repeatability was used in spite of duplicate analysis the same conclusions were obtained (C sample=1.12 ± 0.39 mgF l−1 and C sample=101.4 ± 7.0 mgF l−1). Although the calculated expanded uncertainties and consequently the combined uncertainty, do not vary significantly in the cases where it was used the repeatability or reproducibility for evaluating the precision, each relative variances uncertainty contributions do. When the repeatability is used to determine the combined uncertainty, the CSS and uncertainties contributions are the most dominant ones. However, if reproducibility is used, relative uncertainty variance contributions are distributed among CSS, C F, and precision. In both cases, the contribution increases and r CSS contribution decreases with the increasing of the concentration level. The precision variance contribution is only significant in the case where the reproducibility is used, and increases with the increasing of the concentration level. The uncertainty in the result calculated using the proposed methodology (C sample ± U sample = 2.17 ± 0.42 mgF l−1) is in satisfactory agreement with the estimated expanded uncertainty obtained using the relative reproducibility standard deviation obtained in interlaboratory studies ().  相似文献   

14.
Al(III)- and Zr(IV)-salophens of novel structures were tested as anion-selective ionophores. It was shown that these compounds are highly selective to fluoride and give selectivity greatly deviating from classical Hofmeister pattern, when doped into the polymeric membrane of ion-selective electrode (ISE). The following selectivity sequence has been recorded for both ionophores: F > ClO4 > SCN > NO3 ≈ Br ≈ Cl. The results of potentiometric and spectrophotometric measurements allow to conclude that the nature and structure of salophen ligands influence stability of ISE working parameters. An increase in salophen ligands lipophilicity results in prolongation of the ISE lifetime, most likely due to slower ionophore decomposition caused by the hydrolysis of imine bonds in salophen structure. Ion-selective electrodes (ISEs) with the most successful Al(III)-salophen exhibited a stable, fast and near-Nernstian fluoride response and a functional lifetime near 3 weeks and selectivity coefficients with as follows: −2.8 (Y = Br), −2.7 (Cl), −2.8 (NO3), −1.5 (SCN), −1.3 (ClO4), which is better than for other ones based on Zr(IV)- and Al(III)-salophens and salens described to date.  相似文献   

15.
Formation constants of acetate, hydrogencarbonate, malonate, citrate and 1,2,3-propanetricarboxylate complexes with Na+, K+ and Ca2+ were determined potentiometrically using sodium, potassium and calcium selective electrodes, at 25 °C and at different ionic strengths, in the range 0 < I ≤ 1 M. Formation constants obtained by ion-selective electrode (ISE) measurements were compared with those obtained by different techniques. It has been found that the use of ISEs gives reliable results in the study of weak complexes, also under non-constant ionic strength conditions.  相似文献   

16.
A new highly selective terbium(III) electrode was prepared with a polymeric film doped using S-2-benzothiazolyl-2-amino-α-(methoxyimino)-4-thiazolethiol acetate as an electroactive material, benzyl acetate (BA) as a plasticizer, and potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic site in the percentage ratio 3.17:1.58:63.4:31.7 (ionophore-KTpClPB-BA-PVC, w/w). The electrode exhibited a linear response with a near Nernstian slope of 19.5 mV/decade within the concentration range 1.5 × 10−7−1.0 × 10−2 M terbium ions, with a working pH range from 2.0 to 8.0, and a fast response time of 10 s and presented satisfactory reproducibility. The limit of detection was 9.3 × 10−8 M. The results show that this electrode can be used in ethanol media up to 30% (v/v) concentration without interference. It can be used for 3 months without any considerable divergence in the potentials. Selectivity coefficients for terbium(III) with respect to many cations were investigated. The electrode is highly selective for terbium(III) ions over a large number of monovalent, bivalent, and trivalent cations. This shows the valuable property of the proposed electrode. The stability constant of the ionophore towards Tb3+ ions was determined with the sandwich membrane method. It was successfully used as an indicator electrode in potentiometric determination of terbium(III) ions with EDTA and in direct determination in tap water and binary mixtures with quantitative results. The utility of the proposed electrode was also determined in the presence of ionic and nonionic surfactants and in the presence of fluoride ions in four pharmaceutical (mouthwash) preparations. Figure Structure of S-2-Benzothiazolyl-2-amino-α-(methoxyimino)-4-thiazolethiol acetate  相似文献   

17.
Monitoring of cell cultures in microbioreactors is a crucial task in cell bioassays and toxicological tests. In this work a novel tool based on a miniaturized sensor array fabricated using low-temperature cofired ceramics (LTCC) technology is presented. The developed device is applied to the monitoring of cell-culture media change, detection of the growth of various species, and in toxicological studies performed with the use of cells. Noninvasive monitoring performed with the LTCC microelectrode array can be applied for future cell-engineering purposes. Figure Microelectrode array for monitoring of cell cultures  相似文献   

18.
Cyanide-responsive ion-selective electrodes have been developed based on thin tellurium-doped silver selenide membranes electrodeposited on platinum substrates. The chemical composition of the electroplated film membranes could be expressed by the general formula Ag2+δSe1?xTex (where 0.2 < δ < 0.8 and 0.2 ? × ? 0.1). These electrodes exhibit a linear response in cyanide solutions with concentrations ranging from 10?2 to 10?6 M, with a slope of the electrode function of about 90 mV (pCN)?1 (i.e., lower than the theoretically predicted double-Nernstian slope). These electrodes showed very stable behaviour during long-term investigation (several months). The conditions for the electrochemical preparation of cyanide-responsive silver chalcogenide membranes are discussed both from theoretical and practical points of view. X-ray diffraction, energy-dispersive x-ray fluorescence microanalysis (EDAX) and scanning electron microscopy (SEM) were used to examine the membrane composition, structure and surface morphology.  相似文献   

19.
Two effective types of superparamagnetic nano-scale adsorbents of bayerite/SiO2/Fe3O4 have been synthesized via three sequential steps: chemical precipitation of Fe3O4, coating of SiO2 on Fe3O4 using acidifying method, and further coating of bayerite (Al(OH)3) on SiO2/Fe3O4 adopting sol–gel (MASG) or homogeneous precipitation (MAHP) methods. The characteristics of MASG and MAHP were identified using the transmission electron microscopy (TEM) micrograph, scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM/EDX), X-ray powder diffractometer (XRD), and superconducing quantum interference device (SQUID). Removal of fluoride from aqueous solution was examined to evaluate the adsorptive capacity of MASG, MAHP, and commercial activated alumina (CA), and the effects of enclosure of Fe3O4 with SiO2 for SiO2/Fe3O4, MASG, and MAHP particles. Among the adsorbents tested under the same experimental condition, MASG is the most effective adsorbent, of which the adsorption capacities are 38 g/kg (based on adsorbent mass of adsorption in terms of equilibrium constant qL of Langmuir isotherm), and can compete with CA even at a high pH value. The innovative superparamagnetic adsorbents synthesized in this study possess physicochemical stability at pH range of 6–8 and great potential in the adsorption processes due to not only their high adsorption capacity but also the conveniently magnetic separation which can overcome the difficulty in solid–liquid separation for nano-particles in solutions.  相似文献   

20.
In the photovoltaic industry the etching of silicon in HF/HNO3 solutions is a decisive process for cleaning wafer surfaces or to produce certain surface morphologies like polishing or texturization. With regard to cost efficiency, a maximal utilisation of etch baths in combination with highest quality and accuracy is strived. To provide an etch bath control realised by a replenishment with concentrated acids the main constituents of these HF/HNO3 etch solutions including the reaction product H2SiF6 have to be analysed. Two new methods for the determination of the total fluoride content in an acidic etch solution based on the precipitation titration with La(NO3)3 are presented within this paper. The first method bases on the proper choice of the reaction conditions, since free fluoride ions have to be liberated from HF and H2SiF6 at the same time to be detected by a fluoride ion-selective electrode (F-ISE). Therefore, the sample is adjusted to a pH of 8 for total cleavage of the SiF62− anion and titrated in absence of buffers. In a second method, the titration with La(NO3)3 is followed by a change of the pH-value using a HF resistant glass-electrode. Both methods provide consistent values, whereas the analysis is fast and accurate, and thus, applicable for industrial process control.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号