1.
This study aims to investigate experimentally the effects of three different heat inputs supplied to generator on the energy performance of the diffusion absorption refrigeration system. To achieve this goal, a conventional diffusion absorption refrigeration system, in which electrical resistance as heat input is employed, is taken a model, which is experimentally scrutinized under different heat inputs, 62, 80 and 115 W, but at the same ambient temperatures and the same filling rate of three-component working fluid. In the analyses, the energy losses rejected to ambient from rectifier, condenser, absorber, solution heat exchanger as well as other components such as solution tank and pipes, the energy gain by evaporator and also energy performance is investigated. While the highest energy performance is calculated for DAR-62 W system as 0.36, the lowest energy performance is calculated for DAR-115 W system as 0.30.  相似文献   

2.
Use of a two-phase flow ejector as an expansion device in vapor compression refrigeration systems is one of the efficient ways to enhance its performance. The present work aims to design a constant-area two phase flow ejector and to evaluate performance characteristics of the ejector expansion refrigeration system working with R134a. In order to achieve these objectives, a simulation program is developed and effects of operating conditions and ejector internal efficiencies on the system performance are investigated using EES software. Comparison between present results and published experimental data revealed that the developed model can predict the system COP with a maximum error of 2.3%. The system COP increased by 87.5% as evaporation temperature changed from −10 °C to 10 °C. Finally, correlations to size ejector main diameters as a function of operating conditions, system cooling capacity and ejector internal efficiencies are reported.  相似文献   

3.
A detailed theoretical analysis is presented for a two-stage LiBr/H2O absorption refrigeration system, which consists of an evaporator, a low-pressure absorber, a low-pressure generator, a high-pressure absorber, a high-pressure generator, a condenser, a low-pressure heat exchanger and a high-pressure heat exchanger, driven by a low-temperature hot source. A comparison of results from the theoretical analysis and preliminary experiment indicates that the theoretical analysis developed can represent a real system with a reasonable accuracy, and is useful for future development.  相似文献   

4.
Chemical dehumidification of air by a liquid desiccant in a packed tower has been investigated both theoretically and experimentally for air conditioning and industrial applications. A computer model of a packed tower, able to determine heat and mass transfer between air and desiccant, has been developed and a parametrical study was carried out considering the solutions H2O/LiBr and H2O/CaCl2 to determine the optimum operative conditions. An experimental apparatus including a packed tower and a desiccant regenerator has been described together with experimental results: a set of 70 experimental runs with H2O/LiBr. Data have been reported and compared against the results of the computer code simulations.  相似文献   

5.
In this context, a two-stage absorption-transcritical hybrid refrigeration system is proposed. R744 is chosen as a refrigerant for the transcritical heat pump subsystem and LiBr-H2O working pair for the two-stage absorption refrigeration subsystem. Based on the mathematical and physical models, theoretical investigation is carried out on its performance. The main effects are discussed on COPnet (the ratio of cooling capacity powered by low-grade heat to the low-grade heat consumption for the hybrid system) and COPmt (the ratio of cooling capacity powered by mechanical work to the mechanical work consumption for the hybrid system). Comparing with the normal two-stage absorption refrigeration system, theoretical results show that COPnet could be improved up to about 55% when the refrigeration temperature is 7 °C. In addition, COPmt are more than 50% higher than that of the conventional transcritical refrigeration system. It is also found that both 45–55 °C low-grade heat and condensing heat could be used as actuating heat of the two-stage absorption refrigeration subsystem.  相似文献   

6.
Solubility of aqueous solutions containing lithium bromide + lithium chloride and lithium bromide + sodium formate were measured (LiBr/NaHCO2 = 2 and LiBr/LiCl = 2 by mass ratio) at different temperatures. Visual polythermal method was used in the temperature range of (283.15–340.15) K and mass fraction range of (0.4–0.8). Also density of mentioned systems was reported in the temperature range of (288.15–333.15) K. Each set of experimental measurements were correlated using least-square regression as a function of temperature. Our results indicate that solubility of LiBr + LiCl is higher than LiBr and its density is lower than density of aqueous solution of LiBr.  相似文献   

7.
The purpose of this study is to optimize the amount of oil charge in the electric driven scroll compressor for eco-friendly vehicles. R134a is used as the refrigerant in the vehicle and Polyolester (POE) oil as the compressor oil. The initial amount of oil was increased at 20 g intervals from 40 g to 120 g, and at each initial amount of oil charge, the back pressure is measured at each step of the complex durability test and under each condition of the performance test. Throughout the test, it is found out that the optimum amount of oil is determined by the back pressure, which is 80 g in this test. The performance of a system is compared with pull-down tests in the actual air conditioning system, and the optimum amount of oil was confirmed. A complex durability test was also evaluated and verified for the durability of the compressor with the confirmed amount of oil.  相似文献   

8.
This paper presents an application of robust control theory to an automotive Air Conditioning (A/C) system. A control-oriented model built using moving-boundary method is validated against experimental data collected on a vehicle chassis dynamometer, at constant engine speeds as well as on driving cycles. Next, an H controller is synthesized by formulating an optimization problem whose solution requires appropriate weighting functions selection. Singular perturbation method is utilized to remove states associated with fast dynamics in both model and controller. Both full-order and reduced-order H controllers are verified by simulation results obtained using the nonlinear A/C system model. It is demonstrated that the designed controller is capable of tracking the reference output trajectories while rejecting disturbances introduced on the boundary conditions of the heat exchangers. Furthermore, a preliminary study is performed to reveal the opportunity of designing a gain-scheduled H controller for global output tracking.  相似文献   

9.
The present work aims to evaluate the performance characteristics of a vapor compression refrigeration system using R-438A as a retrofit refrigerant for R-22. In order to achieve this objective, a test facility is developed and experiments are performed over a wide range of chilled water inlet temperature (11:20 °C), condenser water inlet temperature (25:35 °C) and condenser water mass flow rate (363:543 kg h−1). Results showed that as the chilled water inlet temperature changes from 11.5 to 20.5 °C, system COP increases from 1.78 to 2.07 at constant condenser water inlet temperature of 25.5 °C. Cooling capacity and COP of the system using R-438A are lower than R-22 by 11% and 12.5%, respectively. However, compressor discharge temperature using R-438A is slightly lower than R-22 which confirms that R-438A can be used as a retrofit refrigerant for R-22 to complete the remaining life time of the existing plants.  相似文献   

10.
Heat recovery is an effective way to improve adsorption refrigeration system performance due to its easy realization and obvious improvement. Three kinds of heat recoveries (circular heat recovery is complete type and serial and passive heat recoveries are part type) have been applied in recent adsorption refrigerators. Theoretical analysis of three heat recovery methods has been done and results show that serial and passive heat recoveries (part type) are more optimal than circular heat recovery (complete type) when manufacture and cost are considered. Furthermore, a CFD model of a fin-tube type adsorber has been established and simulations of serial and passive heat recoveries have been done. The simulation results show that recovery time of passive heat recovery has an effective range whose value is approximately double of optimum recovery time. Thus, serial heat recovery is more reliable than passive heat recovery. Besides, Optimum recovery time of both serial and passive heat recoveries is approximately equal to the ratio of tube length to heating/cooling flow rate. Contribution distribution of recovered heat has also been analyzed. And the results show that contributions of fluid and tube regions are respectively 89%∼94% and 5%∼10% while contributions of adsorbent and fin regions are negligible.  相似文献   

11.
This paper studies the influence of working fluids over the performance of heat driven ejector refrigeration systems performance by using a lumped parameter model. The model used has been selected after a comparison of different models with a set of experimental data available in the literature. The effect of generator, evaporator and condenser temperature over the entrainment ratio and the COP has been investigated for different working fluids in the typical operating conditions of low grade energy sources. The results show a growth in performance (the entrainment ratio and the COP) with a rise in the generator and evaporator temperature and a decrease in the condenser temperature. The working fluids have a great impact on the ejector performance and each refrigerant has its own range of operating conditions. R134a is found to be suitable for low generator temperature (70–100 °C), whereas the hydrocarbons R600 is suitable for medium generator temperatures (100–130 °C) and R601 for high generator temperatures (130–180 °C).  相似文献   

12.
A pre-industrial prototype of a new water-cooled ammonia/lithium nitrate absorption chiller was characterised at part-load operation mode. The chiller was built using brazed plate heat exchangers in all its components, including the absorber and the generator.A test campaign was carried out varying the thermal load in the chilled water circuit and keeping the hot and cooling water temperatures constant.Part-load curves of the thermal and electrical coefficients of performance were obtained, plotted and compared with data from the literature on small capacity absorption chillers with conventional working pairs, namely ammonia/water and water/lithium bromide. The experimental results showed that to achieve a higher electrical coefficient of performance at part-load operation, it was much more convenient to use an ON-OFF control than to modify the hot water temperature. Furthermore, using a simple ON-OFF control strategy, the behaviour of the new absorption chiller was more agile and responded more quickly.The part-load curve of the electrical coefficient of performance was obtained by adjusting the experimental data to the shape of the curve proposed in the standard prEN-14825:2011 for air-to-water chillers. The Cc coefficient was 0.7985 matching the value obtained dividing the remaining electrical consumption measured during the OFF half cycles by the total energy consumption generated.  相似文献   

13.
A model predictive controller (MPC) was developed in order to optimise energy management of an ice-cream warehouse refrigeration system coupled to a phase-change material (PCM) tank. The controller's internal model was based on a steady-state refrigeration cycle model and energy balances on the PCM tank and warehouse. Considering crystal growth in ice-cream, the quality evolution was based on Ostwald ripening equation. The product temperature field was determined by a 1-D finite difference equation. An original PCM model was developed for better performance of Levenberg–Marquardt's optimisation algorithm which was modified in order to take into account control variables' bounds. Simulation of the ice-cream storage for a period of 90 days lead to good results on the optimised control sequence with efficient energy management thanks to the PCM tank. Ice crystals size remained below the defined target: 26 μm. This study showed the great potential of MPC to reduce energy consumption and guarantee food quality.  相似文献   

14.
A miniature vapor compression refrigeration system included two heat sinks connected in series (indicated as series system) or in parallel (indicated as parallel system) was built. The performance of the series system was studied and compared with that of the parallel system. The results indicate that the largest cooling capacity of the two systems is about 160 W and the optimal refrigerant charge is about 0.6 Mtotal in the miniature vapor compress refrigeration (VCR) system. There is no relation between the optimal refrigerant charge and the arrangement of the heat sinks. The coefficient of performance (COP) of the series system ranged from 1.81 to 3.22, while the COP of the parallel system was in the range of 1.51–2.92 under the cooling capacity of 100 W. The cooling of the heat sink 2 lag behind that of the heat sink 1 in the serial system, while the refrigerant is difficult to equally distribute in the parallel system.  相似文献   

15.
Effects of fin spacing on the temperature distribution in a finned tube adsorber bed are studied to decrease the temperature gradient inside the adsorber bed and minimize the adsorber bed to adsorbent mass ratio (AAMR) for vehicle air conditioning applications. Finned tube adsorber beds have shown higher specific cooling power and coefficient of performance, and low AAMR among the existing adsorber beds. A single-adsorber bed ACS with interchangeable heat exchangers is built and equipped with hermetic type T thermocouples. Two copper heat exchangers with 6.35 mm (1/4″) and 9.5 mm (3/8″) fin spacing are custom-built and packed with 2–4 mm silica gel beads. The experimental results show that by decreasing the fin spacing from 9.5 mm to 6.35 mm, the temperature difference between the fin and adsorbent reduces by 4.6 °C under the cycle time of 600 s and an adsorption to desorption time ratio (ADTR) of one. A greater reduction in the temperature gradient inside the adsorber bed with smaller fin spacing is observed for short cycle time operation, e.g. 600 s, compared to long cycle time operation, e.g. 1400 s. Finally, simultaneous comparison of the temperature gradient between the fins and AAMR against fin spacing indicates that the optimum fin spacing for a finned tube heat exchanger packed with 2–4 mm silica gel beads is about 6 mm.  相似文献   

16.
The developed desiccant-evaporative air-conditioning system was evaluated using the exergetic method under controlled environmental conditions to determine the performances of the whole system and its components.Percentage contributions of exergy destruction of system components at different regeneration temperatures and reference temperatures were determined. Exergy destruction coefficient of different components at different regeneration and reference temperatures were presented. It was shown that exergetic performances varied with respect to the regeneration and reference temperatures. The exergetic performances based on thermal, electric, total exergy input, first definition and second definition efficiencies were shown.Based on the results, reference and regeneration temperatures affected the determination of the system performances and its components. It was shown that air-heating coil, air fans and desiccant wheel contributed to large percentage of exergy destruction. Hence, the mentioned components should be given attention for further improvement of the system performances.  相似文献   

17.
In this paper, the thermoeconomic theory is applied to the economic optimization of a single effect water/LiBr vapour absorption refrigeration system for air-conditioning application, aimed at minimizing its overall operation and amortization cost. The mathematical and numerical techniques based optimization of thermal system is not always possible due to plant complexities. Therefore, a simplified cost minimization methodology is applied to evaluate the economic costs of all the internal flows and products of the system by formulating exergoeconomic cost equations. Once these costs are determined, the system is thermoeconomically evaluated to identify the effects of design variables on costs and enables to suggest values of design variables that would make the overall system cost effective. Finally, an approximate optimum design configuration is obtained by means of sequential local optimization of the system, carried out unit by unit. The result compares this optimum with the base case and shows percentage variations in the system's operation and amortization cost.  相似文献   

18.
Typically the cooling capacity of absorption chillers is controlled by adjusting the driving hot water temperature according to the load. Meanwhile the cooling water temperature is controlled to a constant set value. In order to increase the solar cooling fraction and/or to decrease the operating costs of solar assisted cooling systems (SAC-systems) a new control strategy has been developed which controls hot and cooling water temperature simultaneously. Hereby the specific cost of cold – generated from solar or conventional heat – can be reduced. The basic concept of the strategy is explained and results are shown for the SAC-system at the Federal Environment Agency in Dessau, Germany. Here a recently developed absorption chiller is now used instead of a former adsorption chiller. With the new absorption chiller and the control strategy the seasonal energy efficiency ratio SEER is above 0.75, electric efficiency is 35% higher and water consumption is reduced by 70%.  相似文献   

19.
Most work in dynamic heat exchanger modeling for control design can be classified as either a finite volume or a moving boundary formulation. These approaches represent fundamentally different discretization approaches and are often characterized as contrasting accuracy with simulation speed. This work challenges that characterization by validating finite volume and moving boundary heat exchanger models with experimental data from a vapor compression system in order to demonstrate that these approaches are capable of achieving similar levels of accuracy. However, there are differences. The moving boundary model is found to have faster simulation speed, while the finite volume model is more flexible for adaptation to heat exchangers of different physical configuration. The formulation of each modeling approach used in this work is described in detail and techniques to increase simulation speed and avoid numerical issues in implementation are discussed.  相似文献   

20.
In the rotary compressor, the rolling piston and the contacted rotor-journal bearing system are main moving components. They suffer very large periodically varying loads introduced by the inertia force, the contact force and the gas force. These loads change rapidly with speed variation of the compressor. They always lead to serious vibration of the system, and then result in abrasion and performance reduction. In this paper, the dynamic behavior of the rotor-journal bearing system were calculated by solving three-dimensional numerical model using finite element method, and the vibration characteristics of the system were investigated according to the calculation results. The natural frequencies and vibration modes were obtained. The stress, displacement and axis orbit of the rotor center were calculated considering the speed variation of the motor. Via the established numerical model, vibration characteristics of a newly designed compressor can be predicted, and optimization can be done to reduce the vibration.  相似文献   