首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
通过半导体激光器的注入锁定,产生了频率可在铯原子D2线附近(852。356nm)连续调谐约1GHz以上、压缩度约为0.8dB的振幅压缩光;将其应用在铯饱和蒸气样品的频率调制光谱的演示测量中,信噪比较散粒噪声极限提高了约0.7dB。  相似文献   

2.
温馨  韩亚帅  刘金玉  白乐乐  何军  王军民 《物理学报》2018,67(2):24207-024207
基于PPKTP晶体的阈值以下光学参量振荡(OPO)过程,制备了共振于铷原子D1线795 nm的压缩真空态光场,研究了分析频率处于千赫兹范围的主要噪声来源,特别是795 nm激光及其二次谐波397.5 nm激光在晶体内吸收引起的非线性损耗增加和系统热不稳定的问题(397.5 nm激光处于PPKTP晶体透光范围边缘,具有高于其他波长数倍的吸收系数).以795 nm和1064 nm为例,分析了非线性损耗及晶体内热效应对压缩度的影响.受限于以上因素,795 nm压缩光很难得到1064 nm波段同样的压缩度.探测系统中的噪声耦合则限制了压缩频带.实验上对分析频率为千赫兹的经典噪声进行了有效控制,通过使用真空注入的OPO、垂直偏振及反向传输的腔长锁定光、低噪声的平衡零拍探测器、高稳定度的实验系统及量子噪声锁定等方法,最终在2.6—100 kHz的分析频段得到了约2.8 dB的795 nm压缩真空.该压缩光可用作磁场测量系统的探测光以提高测量灵敏度.  相似文献   

3.
Stable, low noise, infrared squeezed state tight at 1064 nm is generated by utilizing optical parametric down-conversion (OPDC) technique based on periodically poled KTiOPO4 in a optical parametric amplifier (OPA) resonator. A non-classical noise reduction of 2.58 dB below the shot noise is observed through balanced homodyne detection. The squeezed state light is used to set up an imaging system for high-resolution imaging, and it is found that the resolution of image based on the amplitude-squeezed light is 1.26 times larger than that of infrared coherent light under the same intensity. The experimental results indicate that squeezed light is an important non-classical light, which can overcome the coherent laser shot-noise, the classical diffraction limit and limit of quantum noise.  相似文献   

4.
孙志妮  冯晋霞  万振菊  张宽收 《物理学报》2016,65(4):44203-044203
1.5 μm光通信波段非经典光场在光纤中有着极低的传输损耗, 因而是基于光纤的实用化连续变量量子信息研究的重要资源. 本文利用周期极化磷酸氧钛晶体构成的半整块结构简并光学参量放大器, 实验获得了连续变量1.5 μm光通信波段的明亮压缩态光场. 光学参量放大器的阈值功率为230 mW. 当780 nm抽运光场功率为110 mW, 1.5 μm注入信号光场功率为3 mW时, 连续变量1.5 μm明亮正交位相压缩态光场的压缩度达4.7 dB. 进而利用时域零拍探测系统测量压缩态, 采用量子层析技术重构了该明亮正交位相压缩态光场的Wigner准概率分布函数.  相似文献   

5.
Spectroscopic detection of the methane in natural air using an 800 nm diode laser and a diode-pumped 1064 nm Nd:YAG laser to produce tunable light near 3.2 µm is reported. The lasers were pump sources for ring-cavity-enhanced tunable difference-frequency mixing in AgGaS2. IR frequency tuning between 3076 and 3183 cm–1 was performed by crystal rotation and tuning of the extended-cavity diode laser. Feedback stabilization of the IR power reduced intensity noise below the detector noise level. Direct absorption and wavelength-modulation (2f) spectroscopy of the methane in natural air at 10.7 kPa (80 torr) were performed in a 1 m single-pass cell with 1 µW probe power. Methane has also been detected using a 3.2 µm confocal build-up cavity in conjunction with an intracavity absorption cell. The best methane detection limit observed was 12 ppb m (Hz.)–1/2.  相似文献   

6.
Zou H  Zhai S  Guo J  Yang R  Gao J 《Optics letters》2006,31(11):1735-1737
Widely frequency tunable bright sub-Poissonian field preparation has been experimentally achieved with quantum-correlated twin beams in the continuously variable regime. The noise of the sub-Poissonian field is reduced to more than 2 dB below the shot-noise level throughout the entire wavelength-tunable range of 7.4 nm. A maximum noise reduction of 45% (2.6 dB) is observed. The statistical distribution of a sub-Poissonian field is also obtained.  相似文献   

7.
李淑静  张娜娜  闫红梅  徐忠孝  王海 《物理学报》2018,67(9):94204-094204
碱金属原子是光量子存储的良好介质,与碱金属原子共振的非经典光场是量子信息处理的重要资源.本文采用周期极化磷酸氧钛晶体作为非线性介质,利用参量振荡过程产生了795 nm(铷原子D1线)的真空压缩光场.通过对平衡零拍探测系统的时域信号进行采集,得到压缩光场不同相位角下的噪声分布;利用极大似然估计法对压缩光场进行了态重构,得到了密度矩阵及相空间的Wigner函数.理论计算了真空压缩场的光子数分布和Wigner函数,并对理论计算结果和极大似然重构结果进行了分析和比较.  相似文献   

8.
刘增俊  翟泽辉  孙恒信  郜江瑞 《物理学报》2016,65(6):60401-060401
低频压缩态光场可用于提高引力波探测器灵敏度, 近年来受到人们的广泛关注. 相对于高频段而言, 低频压缩态的产生更容易受到外界环境噪声的干扰而不易被观察到. 本文采用全固化单频倍频Nd: YVO4/KTP激光器作为光源, 利用双波长共振的光学参量振荡器实现参量过程, 以1064 nm波长的红外作为基频光, 激光器腔内倍频产生的532 nm绿光作为抽运光, 通过调节周期性极化磷酸氧钛钾晶体温度使光学参量振荡器达到双波长同时共振, 采用真空注入的方式, 利用Pound-Drever-Hall锁腔技术锁定抽运场. 输出压缩光通过平衡零拍探测, 最终在实验上获得了频率低至3 kHz的真空压缩, 所直接观察到的压缩度为2 dB.  相似文献   

9.
Abstract

A polymer/silica hybrid Mach–Zehnder interferometer thermo-optic switch is experimentally demonstrated. The switch exhibits low power consumption of 7.8 mW, high extinction ratio of 32.6 dB, and short rise and fall times of 107 and 71 μs, respectively. The output spectrum is 50 nm (1,520–1,570 nm), with the extinction ratio level of over 18 dB. The driving-noise tolerance of this device was experimentally investigated by imposing a generated tunable noise on the pure driving signal. The device reveals a voltage-noise budget as high as 1.1 Vpp relative to a driving voltage of 3.0 Vpp for obtaining higher than a 10-dB extinction ratio.  相似文献   

10.
成健  冯晋霞  李渊骥  张宽收 《物理学报》2018,67(24):244202-244202
利用低频光通信波段真空压缩态光场可实现基于光纤的量子精密测量.本文利用简并光学参量振荡器实验制备出1550 nm低频真空压缩态光场.在分析频段10—500 kHz范围内压缩态光场的压缩度均达3 dB.用实验制备的1550 nm真空压缩态光场填补光纤马赫-曾德尔干涉仪的真空通道,实现了量子增强型光纤马赫-曾德尔干涉仪,完成了突破标准量子极限的相位调制频率为500 kHz的低频信号测量.与光纤马赫-曾德尔干涉仪相比,测量信噪比提高了2 dB.  相似文献   

11.
A wideband laser phase noise reduction scheme is introduced where the optical field of a laser is single sideband modulated with an electrical signal containing the discriminated phase noise of the laser. The proof-of-concept experiments on a commercially available 1549 nm distributed feedback laser show linewidth reduction from 7.5 MHz to 1.8 kHz without using large optical cavity resonators. This feed-forward scheme performs wideband phase noise cancellation independent of the light source and, as such, it is compatible with the original laser source tunability without requiring tunable optical components. By placing the proposed phase noise reduction system after a commercial tunable laser, a tunable coherent light source with kilohertz linewidth over a tuning range of 1530-1570 nm is demonstrated.  相似文献   

12.
冯晋霞  杜京师  靳晓丽  李渊骥  张宽收 《物理学报》2018,67(17):174203-174203
音频段压缩态光场是进行连续变量量子精密测量重要的量子资源.本文利用自制的低噪声连续单频671 nm/1.34μm双波长激光器作为抽运源,抽运基于周期极化磷酸氧钛钾晶体的简并光学参量振荡器,进行了光通信波段1.34μm连续变量音频段真空压缩态光场的实验制备.当简并光学参量振荡器运转于阈值以下参量反放大状态时,抽运光场功率为95 mW,本地振荡光功率为60μW时,在分析频率8—100 k Hz范围内研制出1.34μm真空压缩态光场.在分析频率36 k Hz处,压缩态光场的最大压缩度达5.0 d B;在音频频率8k Hz处,压缩态光场的压缩度达3.0 d B.音频段1.34μm压缩态光场可用于实现基于光纤的量子精密测量.  相似文献   

13.
低频标准真空涨落的测量   总被引:1,自引:0,他引:1       下载免费PDF全文
薛佳  秦际良  张玉驰  李刚  张鹏飞  张天才  彭堃墀 《物理学报》2016,65(4):44211-044211
采用自平衡零拍方案, 对低频段的标准量子真空涨落进行了测量. 实验确定了该系统的饱和光功率约为3.2 mW. 在10 Hz–400 kHz的频率范围内, 系统的共模抑制比平均为55 dB, 在100 Hz处高达63 dB, 对激光经典技术噪声具有很强的抑制作用. 当入射光功率为400 μ W 时, 真空涨落噪声达到11 dB. 此低频量子真空噪声探测系统可广泛应用于量子计量和量子光学等研究领域.  相似文献   

14.
Squeezed states can be employed for entanglement-based continuous-variable quantum key distribution, where the secure key rate is proportional to the bandwidth of the squeezing. We produced a nonclassical cw laser field at the telecommunication wavelength of 1550 nm, which showed squeezing over a bandwidth of more than 2 GHz. The experimental setup used parametric downconversion via a periodically poled potassium titanyl phosphate crystal. We did not use any resonant enhancement for the fundamental wavelength, which should in principle allow a production of squeezed light over the full phase-matching bandwidth of several nanometers. We measured the squeezing to be up to 0.3 dB below the vacuum noise from 50 MHz to 2 GHz limited by the measuring bandwidth of the homodyne detector. The squeezing strength was possibly limited by thermal lensing inside the nonlinear crystal.  相似文献   

15.
A distributed feedback (DFB) laser diode emitting at 785 nm was tested and applied as a light source for shifted excitation Raman difference spectroscopy (SERDS). Due to the physical properties of the laser diode, it was possible to shift the emission wavelength by 8 cm-1 (0.5 nm) required for our SERDS measurements by simply changing the injection current. The internal grating ensured single mode operation at both wavelength with the frequency stability of ±0.06 cm-1 (0.004 nm) required for high resolution Raman spectroscopic applications. The shifted spectra were used for calculating enhanced Raman spectra being obscured by a strong scattering background. A 16 dB (≈38 fold) improvement of the signal-to-background noise S̄/σB was demonstrated using blackboard chalk as a sample. The tunable DFB laser is a versatile excitation source for SERDS, which could be used in any dispersive Raman system to subtract fluorescence contributions and scattering background. PACS 82.80.Gk; 42.55.-f; 42.64.Fi  相似文献   

16.
Access to quiet areas in cities is important to avoid adverse health effects due to road traffic noise. Most urban areas which are or can become quiet (LA,eq < 45 dB) are shielded from direct road traffic noise. By transfer paths over roof level, many road traffic noise sources contribute to the level in these shielded areas and noise abatement schemes may be necessary to make these areas quiet. Two real life shielded courtyards in Göteborg have been selected as reference cases for a numerical investigation of noise abatement schemes. The selected areas are modelled as canyons with a road traffic noise source modelled outside the canyon by a finite incoherent line source, which is more realistic than both a coherent and an incoherent line source of infinite length. The equivalent sources method has been used for the calculations. For all studied noise abatement schemes in the shielded canyon, the reductions are largest for the lower canyon observer positions. Façade absorption is the most effective when placed in the upper part of the canyon and can typically yield a reduction of 4 dB(A). Constructing 1 m wide walkways with ceiling absorption reduces the level typically by 3 dB(A). These effects are most effective for narrower canyons. For treatments at the canyon roof, reductions are independent of the canyon observer position and amount to 4 dB(A) for a 1 m tall screen and 2 dB(A) for a grass covering of a saddle roof. Downward refracting conditions increase the levels for the lower canyon observer positions and higher frequencies. For sources located in canyons, abatement schemes therein are more effective for noise reduction in the shielded canyon than similar abatement schemes in the shielded canyon itself, given that all contributing source canyons are treated.  相似文献   

17.
Frequency doubling of a Ti:sapphire laser with a KNbO3 crystal has been used to generate wavelength tunable amplitude-squeezed lights in the second harmonic mode. The crystal is placed in an enhancement cavity designed to resonate only the fundamental mode, and the phase matching condition is achieved by changing the crystal temperature. Noise reduction of 1.8–2.0 dB below the shot noise level is observed between 427.28 and 433.76 nm.  相似文献   

18.
We developed a low-noise, single-frequency Tm–Ho:YAG laser tunable in the wavelength interval between 2087 and 2099 nm. To suppress both amplitude and frequency fluctuations the laser has been stabilised by two different control loops. Intensity noise has been effectively reduced using a feedback loop acting on the pump diode current, based on a biquadratic bandpass filter, which provides up to 17 dB suppression at the relaxation oscillation peak. Absolute frequency stabilisation has been achieved by locking the oscillator to the P(12) absorption line of the HBr molecule at 2097.2 nm using the fringe side locking technique, obtaining a long-term frequency stability better than 32 kHz over an observation time of 60 min. This stabilised source is aimed to injection seeding of a coherent lidar system for high precision measurements of wind velocity.  相似文献   

19.
Information from the analysis of gasses dissolved in insulating oils is valuable for early a transformer maintenance. By means of dissolved gas analysis (DGA), it is possible to distinguish faults such as partial discharge (corona), overheating (pyrolysis) and arcing in a great variety of oil-filled equipment. Tunable fiber laser-based second harmonic photoacoustic spectroscopy offers a fast and good-noise-immunity technique for the quantitative analysis of trace gases in transformer oil. In this work, the discharge feature gases, such as C2H2, CH4, CO2 and H2O, were measured with a tunable laser photoacoustic spectrometer at the 1530.3709 nm transition line, as a typical application of precise measurement of multi-gas, a proposed BSS model based on overcomplete ICA basis and five-point-sampling method based on a created weight-truncation-constraint equation was used to remove noise so that several fault gases can be extracted with a higher detection accuracy and a method detection limit. Experiment shows that within 0.15 nm band near 1530.3709 nm, the four-gas contents have been detected and extracted and the detection accuracy has been improved from available scanning spacing of 0.03 nm to available extracting spacing of 0.0011 nm. At room temperature and atmospheric pressure, this can achieve simultaneous detection for multiple feature gases in discharged transformer oil using laser source with a limited waveband.  相似文献   

20.
In this paper we report the characterization of a novel, widely tunable, diode laser source operating over the full telecom L-band (1563–1613 nm), namely the digital supermode distributed Bragg reflector (DS-DBR) laser, and its application to multi-wavelength gas sensing via absorption strategies. The spectroscopic performance of the laser has been assessed by investigating the ro-vibrational spectrum of CO2, and wavelength modulation spectroscopy was accomplished for proof-of-principle sensitive measurements in discrete spectral regions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号