首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Superficial dose from 6- and 18-MV photon beams has been studied by measuring surface dose and shallow build-up dose using radiographic film EDR2, radiochromic film EBT2 and plane-parallel chamber. Measurements have been made for intensity- and non-intensity-modulated beams.The results show that the surface dose was found to be 19.8% and 10% of maximum dose in unmodulated fields for 6 and 18 MV photon beams, respectively. The study further showed that intensity modulation decreased surface dose by 1.1% and 0.7% for the same field size at 6 and 18 MV, respectively, and surface dose was dropped by magnetically sweeping contaminating electrons. EDR2 and EBT2 films show in good agreement in shallow build-up region.This study demonstrated the capability of EDR2 film, in addition to radiochromic film, to measure surface and build-up dose in case of treatment planning system uncertainties with regard to skin toxicity or shallow target coverage.  相似文献   

2.
In the present work a simple model for calculation of the energy response of radiographic films was introduced. According to the model the energy response of a radiographic film is directly proportional to the optical density on the film and thus to the number of developed grains in the emulsion. The model was simulated by Monte Carlo method using MCNP code and the relative energy response of Kodak type 2 film under a few filters of A.E.R.E./R.P.S. film badge was calculated. The simulated responses were in agreement with the experimental data in the region of 30 keV–1.5 MeV. In the next stage a multi-element filter was simulated to optimize the energy response in the above energies. The energy response varied by 25% between 40 keV and 1.5 MeV. So the dose received by the film is equivalent to the desired true dose and there would be no need to the correction factors.  相似文献   

3.
At present, high energy electron linear accelerators (LINACs) producing photons with energies higher than 10 MeV have a wide use in radiotherapy (RT). However, in these beams fast neutrons could be generated, which results in undesired contamination of the therapeutic beams. These neutrons affect the shielding requirements in RT rooms and also increase the out-of-field radiation dose to patients. The neutron flux becomes even more important when high numbers of monitor units are used, as in the intensity modulated radiotherapy. Herein, to evaluate the exposure of patients and medical personnel, it is important to determine the full radiation field correctly. A model of the dual photon beam medical LINAC, Siemens ONCOR, used at the University Hospital Centre of Osijek was built using the MCNP611 code. We tuned the model according to measured photon percentage depth dose curves and profiles. Only 18 MV photon beams were modeled. The dependence of neutron dose equivalent and energy spectrum on field size and off-axis distance in the patient plane was analyzed. The neutron source strength (Q) defined as a number of neutrons coming from the head of the treatment unit per x-ray dose (Gy) delivered at the isocenter was calculated and found to be 1.12 × 1012 neutrons per photon Gy at isocenter. The simulation showed that the neutron flux increases with increasing field size but field size has almost no effect on the shape of neutron dose profiles. The calculated neutron dose equivalent of different field sizes was between 1 and 3 mSv per photon Gy at isocenter. The mean energy changed from 0.21 MeV to 0.63 MeV with collimator opening from 0 × 0 cm2 to 40 × 40 cm2. At the 50 cm off-axis the change was less pronounced. According to the results, it is reasonable to conclude that the neutron dose equivalent to the patient is proportional to the photon beam-on time as suggested before. Since the beam-on time is much higher when advanced radiotherapy techniques are used to fulfill high conformity demands, this makes the neutron flux determination even more important. We also showed that the neutron energy in the patient plane significantly changes with field size. This can introduce significant uncertainty in dosimetry of neutrons due to strong dependence of the neutron detector response on the neutron energy in the interval 0.1–5 MeV.  相似文献   

4.
《Radiation measurements》2007,42(8):1355-1360
The bremsstrahlung energy spectrum generated by the 450 MeV electron linac driving the vacuum ultra violet free electron laser FLASH (free electron laser in Hamburg) operated by DESY was measured with TLD-700 detectors and unfolded using a technique based on a genetic algorithm. The half (1/2), one-fourth (1/4) and tenth (1/10) value layer thickness of lead were estimated to be 1.0, 4.0 and 20 mm, respectively. The peak and average photon energy were calculated from the unfolded bremsstrahlung spectrum and found to be 0.5 and 0.8 MeV, respectively.  相似文献   

5.
Image quality of MeV transmission electrons is an important factor for both observation and electron tomography of microns-thick specimens with the high voltage electron microscope (HVEM) and the ultra-HVEM. In this work, we have investigated image quality of a tilted thick specimen by experiment and analysis. In a 3 MV ultra-HVEM, we obtained transmission electron images in amplitude contrast of 100 nm gold particles on the top surface of a tilted 5 μm thick amorphous epoxy-resin film. From line profiles of the images, we then measured and evaluated image blurring, contrast, and the signal-to-noise ratio (SNR) under different effective thicknesses of the tilted specimen and accelerating voltages of electrons. The variation of imaging blurring was consistent with the analysis based on multiple elastic scattering. When the effective thickness almost tripled, image blurring increased from ~3 to ~20 nm at the accelerating voltage of 3 MV. For the increase of accelerating voltage from 1 to 3 MV in the condition of the 14.6 μm effective thickness, due to the reduction of multiple scattering effects, image blurring decreased from ~54 to ~20 nm, and image contrast and SNR were both obviously enhanced by a factor of ~3 to preferable values. The specimen thickness was shown to influence image quality more than the accelerating voltage. Moreover, improvement on image quality of thick specimens due to increasing the accelerating voltage would become less when it was further increased from 2 to 3 MV in this work.  相似文献   

6.
Continuous-time photoelectron spectroscopy (PES) and continuous-time core-level photon-stimulated desorption (PSD) spectroscopy were used to study the monochromatic soft X-ray-induced reactions of CCl2F2 molecules adsorbed on Si(111)-7 × 7 at 30 K (CCl2F2 dose = 2.0 × 1014 molecules/cm2, ~ 0.75 monolayer) near the Si(2p) core level. Evolution of adsorbed CCl2F2 molecules was monitored by using continuous-time photoelectron spectroscopy at two photon energies of 98 and 120 eV to deduce the photolysis cross section as a function of energy. It was found that the photolysis cross sections for 98 and 120 eV photons are ~1.4 × 10? 18 and ~ 8.0 × 10? 18 cm2, respectively. Sequential F+ PSD spectra obtained by using continuous-time core-level photon-stimulated desorption spectroscopy in the photon energy range of 98–110 eV show the variation of their shapes with photon exposure and depict the formation of surface SiF species. The dissociation of CCl2F2 molecules adsorbed on Si(111)-7 × 7, irradiated by monochromatic soft X-ray in the photon energy range of 98–110 eV, is mainly due to dissociative electron attachment and indirect dipolar dissociation induced by photoelectrons emitted from the silicon surface.  相似文献   

7.
This paper presents the design of a wide-range Parallel Radial Mirror Analyzer (RMA) for use as an attachment inside the specimen chambers of scanning electron/ion microscopes. The range of energies for the PRMA typically varies by a factor of 50, and it is predicted to have second-order focusing properties for all electrons/ions that are detected. For a polar angular spread of ±3°, the simulated energy resolution at an energy of 100 eV is around 0.65%, and it drops to less than 0.2% for energies between 300 eV and 5000 eV. The PRMA is predicted to have a transmittance of over an order magnitude better than previous wide-range parallel energy analyzer designs.  相似文献   

8.
The normoxic polymer gel dosimeter evaluated with X-Ray computed tomography has emerged as a promising tool for measuring the dose delivered during radiotherapy in three dimensions. This study presents the dependence of PAGAT normoxic polymer gel sensitivity to different photon and electron energies. PAGAT polymer gel was prepared under normal atmospheric condition and irradiated with different photon energies of 1.25 MeV from Co-60 and 6 MV and 15 MV from linear accelerator and electron energies of 6, 9, 12, 15, 18 and 21 MeV from linear accelerator. Evaluation of dosimeter was performed with an X-Ray CT scanner. Images were acquired with optimum scanning protocols to reduce the signal-to-noise ratio. The averaged image was subtracted from the unirradiated polymer gel image for background. Central axis depth dose (PDD) curves obtained for each energy and polymer gel dosimeter measurements were in good agreement with diode and film measurements. Hounsfield (HU) – dose response curve for each photon and electron energy were derived from the PDD curve obtained from the gel dosimeter measurements. From the study it was clear that the HU-dose response curve was linear in the region 1–10 Gy. The dosimeter sensitivity was defined as a slope of these linear HU-dose response curves and found that the sensitivity of polymer gel decreases with increase in both photon and electron energies. This trend in dependence of PAGAT gel dosimeter sensitivity to different photon and electron energies was not dosimetrically significant. However, to evaluate the test phantom exposed with one energy using the calibration curve derived at another energy can produce clinically significant error.  相似文献   

9.
Topaz shows thermoluminescence (TL) on heating after exposure to ionising radiation. A study was carried out to explore the possibility to design and develop a TLD (thermoluminescence dosimeter) from locally occurring topaz. Topaz was collected from a mine in Yono Shigar valley in northern Pakistan. The samples were identified as topaz by neutron irradiation, X-ray diffraction and X-ray fluorescence. The crystals of topaz were cut into chips of dimensions compatible to the commercial TLD readers. The chips were exposed to 60Co and/or 137Cs gamma irradiators. The investigation features included glow curve, dose and energy responses, sensitivity, fading, reproducibility and mechanical stability. The TL glow curves revealed a stable peak at about 250 °C, whose height rose linearly with increase of irradiation dose. The TL response versus dose (calibration curve) showed the linear behaviour between 10?2 and 102 Gy. The dose response was independent of gamma energies of 60Co and 137Cs. The response of topaz chips remained constant within 10% deviation from the initial value after 30 cycles of reuse. The rate of fading of topaz was very fast just after irradiation and slowed after a few days. Mechanical stability of the chips remained constant during handling in all investigation experiments. The topaz from Yono Shigar mine may be recommended as a TLD for gamma dose within 10?2–102 Gy.  相似文献   

10.
This study investigated photoluminescent properties of Sr2CaWO6:Yb3+, Na+ phosphor. The samples were successfully synthesized via a solid-state reaction method with various doping concentrations. The phosphor can efficiently absorb ultraviolet photons of 250–350 nm and transfer its absorbed photon energy to Yb3+ ions. Then subsequent quantum cutting between WO6 groups and Yb3+ ions takes place, down-converting an absorbed ultraviolet photon into two photons of 1007 nm radiations. Analyses of decay curves of different samples reveal an efficient energy transfer from WO6 groups to Yb3+ ions. Cooperative energy transfer from host to Yb3+ ions is responsible for downconversion via lifetime analysis. Quantum efficiencies were calculated, and estimated maximum efficiency reached 190%. These phosphors combine wide wavelength absorption in the ultraviolet range with high quantum efficiency, enabling potential application of efficiency enhancement of Si solar cell.  相似文献   

11.
We examine the 12C + 12C elastic scattering over a wide energy range from 32.0 to 70.7 MeV in the laboratory system within the framework of the optical model and the coupled-channels formalism. The 12C + 12C system has been extensively studied within and over this energy range in the past. These efforts have been futile in determining the shape of the nuclear potential in the low energy region and in describing the individual angular distributions, single-angle 50° to 90° excitation functions and reaction cross-section data simultaneously. In order to address these problems systematically, we propose a potential that belongs to a family other than the one used to describe higher energy experimental data and show that it is possible to use it over this wide energy range. This potential also predicts the resonances at correct energies with reasonable widths.  相似文献   

12.
A. Jablonski  C.J. Powell 《Surface science》2010,604(21-22):1928-1939
We present an analysis of the dependence of the backscattering correction factor (BCF) in Auger-electron spectroscopy (AES) on the analyzer acceptance angle. Illustrative BCF calculations are presented for Pd M5N45N45 Auger electrons as a function of primary-electron energy for primary-electron angles of incidence, θ0, of 0° and 80° and for various values of the analyzer acceptance angle. It was necessary to generalize the BCF definition for the case of an analyzer with an arbitrarily large acceptance angle; this was done with a new function, the integral emission depth distribution function. BCFs calculated from an advanced model of electron transport in the surface region of the Pd sample varied weakly with analyzer half-cone angle for θ0 = 0° but more strongly for θ0 = 80° where there were BCF differences varying between 19% at a primary energy of 1 keV and 6% at a primary energy of 5 keV. These BCF differences are due in part to variations of the BCF with emission angle and in part to variations of the density of inner-shell ionizations within the information depth for the detected Auger electrons. The latter variations are responsible for differences larger than 10% between BCFs from the widely used simplified BCF model and those from the more accurate advanced model for primary energies less than about 5 keV for θ0 = 80°. For normal incidence of the primary beam, differences greater than 10% between BCFs from the simplified and advanced models were found for primary energies between 1 keV and 4 keV. These BCF differences indicate that the simplified model can provide only approximate BCF values. In addition, the simplified model does not provide any BCF dependence on Auger-electron emission angle or analyzer acceptance angle.  相似文献   

13.
This study presents the first dosimetric evaluation of the alanine-in-glass dosimeter in radiation therapy. The dosimeter is composed of a Pyrex glass tube filled with pure polycrystalline alanine. 6 MV X-ray beams from a linear accelerator were used to irradiate the dosimeter in a solid water phantom to therapy-level doses ranging from 0 to 30 Gy. An X-band electron paramagnetic resonance (EPR) spectrometer was utilized to measure the absorbed dose of the dosimeter. The doses measured by the dosimeter were compared to those from ion chamber dosimetry. It was found that the dosimeter exhibited a linear response in the dose range from 0.1 to 30 Gy. The deviation between measured and delivered doses was 0.11% over the 0.5–30 Gy range, whereas the deviation increased to about 25% at 0.1 Gy. The lowest detectable dose with an acceptable deviation limit of 5% or less was found to be 0.3 Gy. The inaccuracy in measurements at low doses can be attributed to background signals and instrument noise. The accuracy can be improved by proper selection of measurement conditions and better optimization of equipment. The findings of this study show that the alanine-in-glass dosimeter is suitable for dose measurements with acceptable accuracy down to 0.3 Gy. The dosimeter is therefore has the potential to be employed in radiotherapy applications and quality control procedures.  相似文献   

14.
N. Pauly  S. Tougaard 《Surface science》2010,604(13-14):1193-1196
In XPS analysis, two effects, which significantly reduce the measured peak intensity, are usually neglected: the core hole left behind in an XPS process which causes “intrinsic” excitations and excitations as the photoelectron pass through the surface region. We have calculated these effects quantitatively for various energies, geometries, and materials. Instead of considering the two effects separately, we introduce a new parameter, namely the correction parameter for XPS or CPXPS, which takes into account both effects. We define this CPXPS as the change in probability for emission of a photoelectron caused by the presence of the surface and the core hole in comparison with the situation where the core hole is neglected and the electron travels the same distance in an infinite medium. The calculations are performed within the dielectric response theory by means of the QUEELS–XPS software determining the energy-differential inelastic electron scattering cross-sections for X-ray photoelectron spectroscopy (XPS) including surface and core hole effects. This study has been carried out for electron energies between 300 eV and 3400 eV, for angles to the surface normal between 0° and 60° and for various materials. We find that the absolute effect is a reduction by 35–45% in peak intensities but that the variation in CPXPS with material, angle and energy are < ± 10% for emission angle ≤ 60° and photoelectron energy ≤ 1500 eV. This implies that when XPS analysis is done using relative intensities, the combined effect of the surface and of the core hole is typically less than ≈ ± 10% for geometries and energies normally used in XPS. In practice, it is however difficult to determine the bare peak intensity without the intrinsic electrons because the two overlap in energy.  相似文献   

15.
The aim of this paper is to evaluate the thermoluminescent (TL) response of a larimar, a variety of pectolite (NaCa2Si3O8[OH]). It is a blue pectolite only found on the terrestrial crust of the province of Barahona, in the south-western region of the Dominican Republic. The larimar rock used in this study, presented a light-blue color with brown areas. X-ray powder diffractometry (XRD), showed that the light-blue portion of the rock is composed essentially by pectolite and the brown portion is composed by a mixture of minerals. Aliquots of 5 mg of light-blue portions were irradiated with gamma rays with doses from 10 to 104 Gy and the TL glow curves were obtained from 50 to 400 °C. The glow curve showed a broad peak around 150 °C and a peak near 280 °C. Different pre-heat condition were used to remove the broad peak. The TL emission of the main peak appeared in the region of 580 nm. The TL response of the main peak showed a linear behavior up to 2500 Gy and a sub-linear behavior above this dose value. Studies of the 30 day fading effects in TL signal using a pre-heating temperature around 180 °C during 15 min were carried out and fading near 25% was observed.  相似文献   

16.
This paper reports on the thermo (TL), iono (IL) and photoluminescence (PL) properties of nanocrystalline CaSiO3:Eu3+ (1–5 mol %) bombarded with 100 MeV Si7+ ions for the first time. The effect of different dopant concentrations and influence of ion fluence has been discussed. The characteristic emission peaks 5D07FJ (J=0, 1, 2, 3, 4) of Eu3+ ions was recorded in both PL (1×1011–1×1013 ions cm?2) and IL (4.16×1012–6.77×1012 ions cm?2) spectra. It is observed that PL intensity increases with ion fluence, whereas in IL the peaks intensity increases up to fluence 5.20×1012 ions cm?2, then it decreases. A well resolved TL glow peak at ~304 °C was recorded in all the ion bombarded samples at a warming rate of 5 °C s?1. The TL intensity is found to be maximum at 5 mol% Eu3+ concentration. Further, TL intensity increases sub linearly with shifting of glow peak towards lower temperature with ion fluence.  相似文献   

17.
Thermoluminescence (TL) measurements were carried out on undoped and Mn2+ doped (0.1 mol%) yttrium aluminate (YAlO3) nanopowders using gamma irradiation in the dose range 1–5 kGy. These phosphors have been prepared at furnace temperatures as low as 400 °C by using the combustion route. Powder X-ray diffraction confirms the orthorhombic phase. SEM micrographs show that the powders are spherical in shape, porous with fused state and the size of the particles appeared to be in the range 50–150 nm. Electron Paramagnetic Resonance (EPR) studies reveal that Mn ions occupy the yttrium site and the valency of manganese remains as Mn2+. The photoluminescence spectrum shows a typical orange-to-red emission at 595 nm and suggests that Mn2+ ions are in strong crystalline environment. It is observed that TL intensity increases with gamma dose in both undoped and Mn doped samples. Four shouldered TL peaks at 126, 240, 288 and 350 °C along with relatively resolved glow peak at 180 °C were observed in undoped sample. However, the Mn doped samples show a shouldered peak at 115 °C along with two well defined peaks at ~215 and 275 °C. It is observed that TL glow peaks were shifted in Mn doped samples. The kinetic parameters namely activation energy (E), order of kinetics (b), frequency factor (s) of undoped, and Mn doped samples were determined at different gamma doses using the Chens glow peak shape method and the results are discussed in detail.  相似文献   

18.
We present joint experimental and theoretical results on the elastic scattering of spin-polarized electrons from an epitaxial Au film on a W(110) substrate in the energy range from 8 eV to 27 eV. A time-of-flight technique with a position-sensitive detector is applied to measure secondary emission spectra for spin-up and spin-down primary electrons in a specular geometry. The spin-asymmetry of coherently scattered electrons is obtained by selecting the diffraction spot on the detector. Regions of large asymmetries – with a maximum of about ?60 % – are identified for electron energies of about 14 eV. Relativistic multiple-scattering calculations produce spin-orbit-induced asymmetries which are in agreement with their experimental counterparts. They further reveal that large asymmetries are associated with high intensities. This offers the possibility of an efficient new spin polarimeter with a figure of merit of about 1.5 · 10?2.  相似文献   

19.
We have experimentally evaluated attenuation lengths (AL) of photoelectrons traveling in compact and micro and mesoporous (~ 45% voids) SiO2 thin films with high (8.2–13.2 keV) kinetic energies. The films were grown on polished Si(100) wafers. ALs were deduced from the intensity ratio of the Si 1s signal from the SiO2 film and Si substrate using the two-peaks overlayer method. We obtain ALs of 15–22 nm and 23–32 nm for the compact and porous SiO2 films for the range of kinetic energies considered. The observed AL values follow a power law dependence on the kinetic energy of the electrons where the exponent takes the values 0.81 ± 0.13 and 0.72 ± 0.12 for compact and porous materials, respectively.  相似文献   

20.
Continuous-time photoelectron spectroscopy (PES) and photon-exposure-dependent photon-stimulated desorption (PSD) were employed to investigate the monochromatic soft X-ray-induced dissociation of SF6 molecules adsorbed on Si(111)-7 × 7 at 30 K (SF6 dose = 3.4 × 1013 molecules/cm2, ~ 0.5 monolayer). The photon-induced evolution of adsorbed SF6 was monitored at photon energies of 98 and 120 eV [near the Si(2p) edge], and sequential valence-level PES spectra made it possible to deduce the photolysis cross section as a function of energy. It was found that the photolysis cross sections for 98 and 120 eV photons are ~ 2.7 × 10? 17 and ~ 3.7 × 10?17 cm2, respectively. The changes in the F? and F+ PSD ion yields were also measured during irradiation of 120 eV photons. The photon-exposure dependencies of the F? and F+ ion yields show the characteristics: (a) the dissociation of adsorbed SF6 molecules is ascribable to the substrate-mediated dissociations [dissociative attachment (DA) and dipolar dissociation (DD) induced by the photoelectrons emitting from the silicon substrate]; (b) at early stages of photolysis, the F? yield is mainly due to DA and DD of the adsorbed SF6 molecules, while at high photon exposure the F? formation by electron capture of the F+ ion is likely to be the dominant mechanism; (c) the F+ ion desorption is associated with the bond breaking of the surface SiF species; (d) the surface SiF is formed by reaction of the surface Si atom with the fluorine atom or F? ion produced by scission of S–F bond of SFn (n = 1–6) species.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号