1.
采用微波样品处理器及石墨炉原子吸收法对螺旋藻样品中微量铅的直接测定进行了研究,确定了测定螺旋藻中铅的最佳仪器参数。该方法具有灵敏度高,干扰少的特点,是测定螺旋灌中铅含量的一种有效分析手段。方法下限可达0.002μg.mL^-1,样品加标回收率为99.2-100.2%,变异系数(RSD)为0.33%,结果令人满意。 相似文献
2.
3.
4.
血液样品中微量砷的简便石墨炉原子吸收测定法 总被引:1,自引:0,他引:1
在酸浸出法测定镉含量的基础上,用超声处理血液样品,建立了一种简便的石墨炉原子吸收分光光度地法来测定血液样品中的微量砷。通过不同基体改进剂的比较,确定了镍作为测定砷的基体改进剂,1.0mL血液样品用0.1mL 8mol/L HCl浸泡样品,超声处理30分钟后测定,其检出限为3.03ng/mL;线性范围为5.0~50.0ng/mL;精密度为2.5%,回收率在88.0%~98.1%之间,研究表明该法测定血液中的微量砷,具有简单、灵敏、精密、准确等特点,用本法测定了慢性砷中毒小鼠红细胞中的砷含量,结果表明中毒组小鼠红细胞中砷含量显著高于对照组。 相似文献
5.
《仪器科学与技术》2013,41(6):689-694
Abstract Electrothermal atomic absorption spectrometry (ETA‐AAS) was utilised for the estimation of Cu, Fe, Mn, Ni, and Zn, which are additives for desired properties in different lubricating oils, directly and when subjected to 500°C with and without the addition of xylene. The results show that, for the samples subjected to 500°C and treated with xylene before analysis, the coefficient of variation and, hence, precision improved for the elements. The result obtained also shows that there are no significant variations, indicating that, with the ETA‐AAS technique, the samples require no chemical pre‐treatment. This is so because the chemical matrix is removed by ashing prior to atomisation. 相似文献
6.
快速石墨炉原子吸收法测定地面水中痕量镉和铅 总被引:1,自引:0,他引:1
本文探讨了用快速石墨炉原子吸收法测定需水中痕量镉和铅。系统地研究了石墨炉升温程序及基体改进剂对测定的影响。提出了删去灰化步骤,在不需要基体改进剂情况下快速测定环境清洁地面水中镉和铅的方法。镉和铅的方法检出限分别为 0.05ug/1和 1.2ug/1,相对标准偏差(RSD)(Cd:n=9,Pb:n=11)分别为7.2%和4.1%,加标回收率分别在113%-116%和90.0%-92.0%之间。 相似文献
7.
泡沫塑料富集-火焰原子吸收法测定铜精矿中金 总被引:1,自引:0,他引:1
王水分解铜精矿后不经除矿渣,直接放入泡沫塑料吸附Au,并于沸水浴中用20g/L硫脲水溶液解脱被吸附的Au,然后火焰原子吸收法测定。对w(Au)为6×10-6的试样测定7次,RSD为38%。讨论了泡塑吸附Au的机理。 相似文献
8.
Nusrat Jalbani 《仪器科学与技术》2013,41(5):573-587
Single-solidified floating organic drop microextraction was used for the preconcentration and determination of Cd(II) and Pb(II). The procedure employed 1-(2-pyridylazo)-2-naphthol as a chelating agent, 1-undecanol as the extractant solvent, and methanol as the dispersive solvent. Factors influencing the recovery of Cd(II) and Pb(II) such as the pH, volume of extractant, volume of ligand, volume of dispersant, and stirring time were optimized by Plackett Burman design. In order to complete the optimization, a central 23 +star orthogonal composite design was applied. The limits of detection for Cd(II) and Pb(II) were 0.15 and 0.52 μg L?1. The validation of the procedure was evaluated by the analysis of TMDA 70 Fortified Water and NCSDC–73349 Bush Branches certified reference materials. The determined values were in good agreement with the certified values. The single-solidified floating organic drop microextraction method was employed for the determination of cadmium and lead in water, vegetables, and fruit. 相似文献
9.
10.
11.
采用氢化物-原子荧光法测定蔬菜中的铅含量具有操作简单、快速、基体干扰少、灵敏度高、节省试剂等优点。用此法测定蔬菜样品中的铅有很好的适用性,方法的检出限为0.8ng/mL回收率为95.7%~110.4%,线性范围为3~500ng/mL。 相似文献
12.
13.
石墨炉原子吸收光谱分析中化学改进技术的进展 总被引:5,自引:0,他引:5
化学改进技术是一种在线化学处理技术,既利用了常规化学处理消除干扰、提高测定灵敏度的优点。又避免了常规化学处理费时费力、易玷污和损失的缺点,广泛地应用于电热原子吸收光谱分析中。本文回顾了化学改进技术的历史发展,对近十年石墨炉电热原子吸收光谱分析中化学改进技术的进展做了较全面介绍,内容包括:常用化学改进剂中的金属化学改进剂,磷酸盐化学改进剂,有机物化学改进剂和复合化学改进剂,持久化学改进剂,化学改进剂的作用机理。在结语中,对化学改进技术今后的发展提出了作者的看法。引用国内外近年文献110篇。 相似文献
14.
15.
16.
17.
本文提出了一种测定铭铂(抗癌药)中微量钡和银的方法。样品用0.016mol/lHNO_3进行溶解后,按照所选的最佳试验条件应用涂钨热解石墨管——石墨炉原子吸收法测定钡,避免了钡的碳化物形成,提高了方法的灵敏度。分析结果证实,其特征量为4.1pg/1%吸收,检出限22.14pg,加标回收率94.3%~101.5%,相对标准偏差小于14.8%。用普通石墨管测定银,其特征量为7.8pg/1%吸收,检出限1.6pg,加标回收率94.4%~96.7%,相对标准偏差小于6.63%。该法具有良好的精密度和准确度。 相似文献
18.
采用日立-7000型原子吸收分光光度计,以热解涂层石墨管,塞曼效应背景校正技术,结合HNO3浸出离心去蛋白法,检测了百色市区50例正常人血清中Pb的含一,范围在42.65-386.7μg/L。检测158.75μg/LPb水平的血清样,其相对标准偏差为1.6%。 相似文献
19.
本文建立了测定纺织品模拟酸性汗液中可萃取重金属铅的氢化物-原子荧光光谱法。本法灵敏度高、准确性好、可以在高盐的情况下直接测定铅的含量。在选定的实验条件下,铅浓度与荧光强度在0~50μg/L范围内线性关系良好,方法的检出限为0.003mg/kg,定量下限为0.010mg/kg(以4g样品计),加标回收率99.6%-99.8%,相对标准偏差RSD〈2.0%。 相似文献
20.
本文通过建立数学模型,用实验室内精密仪和偏差的数据来对腊肠中钠测量的不确定度进行评估,取得良好的效果。本文采用了火焰原子吸收光谱法测定腊肠中钠含量,对其测定过程进行分析、评定,分析了腊肠中钠含量测定中称量、配制、重复性测定及线性拟合曲线时所带来的不确定度,获得其不确定度结果,其扩展不确定度为U=10.26mg.kg~(-1)(k=2)。通过评定测量过程中存在的不确定度,使其结果更科学可靠。 相似文献