首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The present work investigates the contact forces between sitters and seat as well as their correlations with perceived discomfort. Twelve different economy class aeroplane seat configurations were simulated using a multi-adjustable experimental seat by varying seat pan and backrest angles, as well as seat pan compressed surface. Eighteen males and 18 females, selected by their body mass index and stature, tested these configurations for two sitting postures. Perceived discomfort was significantly affected by seat parameters and posture and correlated both with normal force distribution on the seat-pan surface and with normal forces at the lumbar and head supports. Lower discomfort ratings were obtained for more evenly distributed normal forces on the seat pan. Shear force at the seat pan surface was at its lowest when sitters were allowed to self-select their seat-pan angle, supporting that a shear force should be reduced but not zeroed to improve seating comfort.

Practitioner Summary: The effects of seat-pan and backrest angle, anthropometric dimensions and sitting posture on contact forces and perceived discomfort were investigated using a multi-adjustable experimental seat. In addition to preferred seat profile parameters, the present work provides quantitative guidelines on contact force requirement for improving seating comfort.  相似文献   


2.
《Ergonomics》2012,55(7):889-911
Abstract

This literature review focused on passenger seat comfort and discomfort in a human–product–context interaction. The relationships between anthropometric variables (human level), activities (context level), seat characteristics (product level) and the perception of comfort and discomfort were studied through mediating variables, such as body posture, movement and interface pressure. It is concluded that there are correlations between anthropometric variables and interface pressure variables, and that this relationship is affected by body posture. The results of studies on the correlation between pressure variables and passenger comfort and discomfort are not in line with each other. Only associations were found between the other variables (e.g. activities and seat characteristics). A conceptual model illustrates the results of the review, but relationships could not be quantified due to a lack of statistical evidence and large differences in research set-ups between the reviewed papers.

Practitioner Summary: This literature review set out to quantify the relationships between human, context and seat characteristics, and comfort and discomfort experience of passenger seats, in order to build a predictive model that can support seat designers and purchasers to make informed decisions. However, statistical evidence is lacking from existing literature.  相似文献   

3.
As the population of elderly people in society rises, the importance of technology to assist health management is growing with the demographic shift. Wearable personal computing has been the common solution proposed by related projects to fulfil the needs of elderly people. These add-on devices are attached to the users, and result in uneasiness or discomfort while wearing them in public areas. In this study, three common wearing positions – wrist, upper arm, and neck – were investigated in terms of psychological perception and perceived readability. Twenty-four Taiwanese participants in Miaoli area were asked to wear the designed prototypes for a certain time. The participants completed questionnaires and participated in an open-ended interview. Data of psychological perceptions, visibility, and readability about wearable devices were collected. The results evidenced that the personal attributes of gender, smart device user, and requirement for medical care affect the psychological perception and user attitudes. The statistical results indicated significant differences in elderly people's attitudes towards wearable devices attached to different parts of the body. The wrist was the most favourable location to attach a wearable device.  相似文献   

4.
《Ergonomics》2012,55(7):1147-1158
In order to examine the effects of work surface height (WSH) on muscle activity, posture and discomfort during simulated pipetting, an experimental study was conducted using electromyography, electrogoniometry, video techniques and also qualitative data. The experimental design consisted of one independent variable (WSH with six heights) and 13 dependent variables. The levels of muscle strain and discomfort were significantly lower at the shoulder when the WSHs were low but thumb muscle activities and neck flexion levels were markedly higher at these WSHs compared to higher WSHs. To reduce shoulder strain, without raising thumb and neck strain beyond acceptable limits, the findings suggest that the height of a laboratory workbench should be at the level of the pipette tip when held in a standing position with the hand at elbow height. It was also found that pipetting should not be done in a seated posture.

Practitioner Summary: An experimental study was conducted to examine the effects of work surface height on upper extremity muscle activity, posture and discomfort during simulated pipetting. The findings suggest that the laboratory workbench height should be at the pipette-tip level when held in a standing position with the hand at elbow height.  相似文献   

5.
Abstract

Situated in the domain of research into mobile, wireless, networked and wearable computing, this exploratory paperintroduces the embodied imagination method and explains how it can contribute to the design process by creating an elastic space of performance that incorporates daily life and personal imagination into the design process. It is based on a study called Placebo Sleeves which was an experiential design phase of a larger project in wearable computing called whisper[s]. The innovation offered by this research is twofold: an integration of previously distinct methodologies, and an interdisciplinary theoretical framework relevant to the design of devices for affective, networked communication. The methodologies are shaped both by user experience models and by performance practices. We also articulate a domain of public dreaming, located at the conjunction of the private, public and secret within human existence, and suggest that shared use of mobile technologies has the potential to be situated there.  相似文献   

6.
Knight JF  Baber C 《Human factors》2007,49(5):797-807
OBJECTIVE: The aim of the present study was to determine if a wearable system based on a head-mounted display (HMD) causes users to alter their head position and adopt postures that place greater stress on the musculoskeletal system. BACKGROUND: HMDs are common output devices used with wearable computers. HMDs provide the wearer with visual information by projecting computer-generated virtual images in front of the eyes. Deviations of neck posture from a neutral upright position increase the stresses on the musculoskeletal system of the head and neck. METHOD: Seven paramedics simulated the treatment of a patient under a normal condition and when using an HMD wearable computer system. During the simulations a posture analysis was performed using the Rapid Upper Limb Assessment method. RESULTS: The postures adopted when wearing an HMD, as compared with a normal condition, scored significantly higher for the neck (z = 2.463, p < .05) and for overall body posture (left side of the body: z = 2.447, p < .05; right side of the body: z = 2.895, p < .05). CONCLUSION: Wearing an HMD can force the wearers to modify their neck posture. As such, the musculoskeletal system of the head and neck may be placed under increased levels of stress. APPLICATION: Potential users should be made aware that HMDs could dictate modifications in neck posture, which may have detrimental effects and may compound the weight effect of the HMD.  相似文献   

7.
Wearable computers: no longer science fiction   总被引:2,自引:0,他引:2  
By using devices carried on the body, wearable computers allow the exploration of the principles of pervasive computing immediately instead of waiting for the deployment of the ubiquitous infrastructure often associated with the field. However, wearable computers are often misunderstood, both in their research and application. I've been wearing a computer as part of my daily life since 1993, and in this article, I explore the attributes that make wearable computers a unique approach to ubiquitous computing and discuss current topics in the wearable computing field.  相似文献   

8.
A postural evaluation during a prolonged driving task was conducted to determine the ergonomic validity of a new freely adjustable truck seat prototype. Twenty participants were recruited to perform two 2-h simulated driving sessions. Postures were assessed using motion capture, accelerometers and pressure pads. Subjective discomfort was also monitored in 15-min increments using ratings of perceived discomfort (RPD) and the Automotive Seating Discomfort Questionnaire. Participants had a more neutral spine posture during the first hour of the drive and reported lower RPDs while sitting in the prototype. Pairing the gluteal backrest panel with the adjustable seat pan helped reduce the average sitting pressure. The industry-standard truck seat may lead to the development of poor whole body posture, and the proposed ergonomic redesign of a new truck seat helped improve sitting posture and reduce perceived discomfort.

Practitioner Summary: A new freely adjustable truck seat prototype was compared to an Industry standard seat to assess hypothesised improvements to sitting posture and discomfort for long haul driving. It was found that the adjustable panels in the prototype helped promote spine posture, reduce sitting pressure and improved discomfort ratings.  相似文献   


9.

Recently, there is a tremendous rise and adoption of smart wearable devices in smart healthcare applications. Moreover, the advancement in sensors and communication technology empowers to detect and analyse physiological data of an individual from the wearable device. At present, the smart wearable device based on internet of things is assisting the pregnancy woman to continuously monitor their health status for avoiding the severity. The physiological data analysis of wearable device is processed with the assistance of fog computing due to limited computational and energy capability in the wearable device. Additionally, fog computing overcomes the excess latency that is created by cloud computing during physiological data analysis. In this article, a smart health monitoring IoT and fog-assisted framework are proposed for obtaining and processing the temperature, blood pressure, ECG, and pulse oximeter parameters of the pregnant woman. Based on real time series data, the rule-based algorithm logged in the wearable device with fog computing to analyse the critical health conditions of pregnant women. The proposed wearable device is validated and tested on 80 pregnant women in real time, and wearable device is delivering the 98.75% accuracy in providing health recommendations.

  相似文献   

10.
《Ergonomics》2012,55(12):1207-1213
Thirteen male children ascending and descending stairs with loads that equalled 0%, 10%, 15% and 20% of their body weight were the subject of our research: the boys were wearing an asymmetrical single-strap athletic bag or a symmetrical double-strap backpack during our experiments with them. The maximum spinal tilt to the loading side and to the support side, and the range of spinal motions, were obtained by using a motion analysis system. Our results showed that symmetry of spinal posture was observed both when they ascended staircase with all loads and descended in a backpack. When carrying an athletic bag with 15% and 20% of their body weight while ascending the staircase, the lateral spinal tilt to the supporting side was significantly increased. We concluded that a symmetrical backpack with a load not exceeding 20% or an asymmetrical single-strap athletic bag with a load not exceeding 10% should be recommended for school children in order to promote safer staircase use.

Statement of Relevance: Children carrying heavy school bags may develop spinal problems. This study suggested that when they are using stairs, a symmetrical backpack with a load within 20% body weight is acceptable for them. When they are carrying an asymmetrical single-strap athletic bag, the bag's weight should not exceed 10% of the body weight in order to avoid excessive spinal tilt.  相似文献   

11.
This study presents usability considerations and solutions for the design of glasses-type wearable computer displays and examines their effectiveness in a case study. Design countermeasures were investigated by a four-step design process: (1) preliminary design analysis; (2) design idea generation; (3) final design selection; and (4) virtual fitting trial. Three design interventions were devised from the design process: (1) weight balance to reduce pressure concentrated on the nose, (2) compliant temples to accommodate diverse head sizes and (3) a hanger mechanism to help spectacle users hang their wearable display on their eye glasses. To investigate their effectiveness, in the case study, the novel 3D glasses adopting the three interventions were compared with two existing 3D glasses in terms of neck muscle fatigue and subjective discomfort rating. While neck muscle fatigue was not significantly different among the three glasses (p = 0.467), the novel glasses had significantly smaller discomfort ratings (p = 0.009).

Relevance to Industry: A four-step design process identified usability considerations and solutions for the design of glasses-type wearable computer displays. A novel 3D glasses was proposed through the process and its effectiveness was validated. The results identify design considerations and opportunities relevant to the emerging wearable display industry.  相似文献   


12.
Jonathan DeShaw 《Ergonomics》2016,59(4):568-581
This work presents a predictive model to evaluate discomfort associated with supine humans during transportation, where whole-body vibration and repeated shock are predominant. The proposed model consists of two parts: (i) static discomfort resulting from body posture, joint limits and ambient discomfort; and (ii) dynamic discomfort resulting from the relative motion between the body segments as a result of transmitted vibration. Twelve supine subjects were exposed to single and 3D random vibrations and 3D shocks mixed with vibrations. The subjects’ reported discomfort and biodynamic response were analysed under different support conditions, including a rigid surface, a stretcher and a stretcher with a spinal backboard. The results demonstrated good correlations between the predictive discomfort and the reported discomfort for the different conditions under consideration, with R2 = 0.69–0.94 for individual subjects and R2 = 0.94 for the group mean. The results also indicated a strong relationship between the head-neck and trunk angular velocities and discomfort during supine transportation.

Practitioner Summary: The quantification of discomfort of supine humans under vibration and shocks by using a predictive model is an important contribution to this field, whereby the efficacy of different transport systems can be compared. The predictive discomfort model can be used as design criteria for ergonomic enhancement in supine transportation of humans.  相似文献   


13.
《Ergonomics》2012,55(8):1123-1136
Abstract

Ergonomic measurement is central to product design and development; especially for body worn products and clothing. However, there is a large variation in measurement definitions, complicated by new body scanning technology that captures measurements in a posture different to traditional manual methods. Investigations of hip measurement definitions in current clothing measurement practices supports analysis of the effect of scan posture and hip measurement definition on the circumferences of the hip. Here, the hip girth is a key clothing measurement that is not defined in current body scanning measurement standards. Sixty-four participants were scanned in the standard scan posture of a [TC]2 body scanner, and also in a natural posture similar to that of traditional manual measurement collection. Results indicate that scan posture affects hip girth circumferences, and that some current clothing measurement practices may not define the largest lower body circumference. Recommendations are made concerning how the hip is defined in measurement practice and within body scanning for clothing product development.

Practitioner Summary: The hip girth is an important measurement in garment design, yet its measurement protocol is not currently defined. We demonstrate that body posture during body scanning affects hip circumferences, and that current clothing measurement practices may not define the largest lower body circumference. This paper also provides future measurement practice recommendations.  相似文献   

14.
《Ergonomics》2012,55(9):839-853
Abstract

A laboratory study was conducted to determine the maximum frequencies acceptable to female workers for one-handed lifts in the horizontal plane. A psychophysical method was used to determine maximum acceptable frequency for an 8-hour workday. Ten female college students were required to lift continuously three different loads to two different reach distances (38 and 63 cm) on a 91 cm high work table. The lifting task was paced by a repeating timer which the subject controlled according to her subjective feelings of fatigue. Heart rate and RPE were measured during the last 5min of the experiment to determine the physiological level of functioning and perceived exertion. Psychophysically determined maximum acceptable frequencies were compared with the standards based on methods-time measurement (MTM) analysis.

Statistical analysis showed that both the weight of the load and reach distance had a significant effect on maximum frequency acceptable to the subjects. No single value for percentage of maximum frequency can be used to establish permissible one-handed lift limits in women; rather, this value depends upon the weight of the object and distance of lift. The average maximum acceptable frequency was 51% of the maximum frequency that the subjects could maintain for a period of 4min. The subjects selected workloads which resulted in a mean heart rate of 101 beats/min. The subjects rated the perceived exertion ranging from ‘fairly light’ to ‘somewhat hard’. Performance based on MTM analysis ranged from 11% below to 32% above the maximum workload acceptable to the subjects. The non-significant heart rate differences found among the six load-distance combinations lend strong support for the use of psychophysical methodology in future studies of fatigue criteria. The study also supports the previous findings that separate physiological fatigue criteria are needed for tasks involving arm work and whole body exertion.  相似文献   

15.
A laboratory study was conducted to determine how users of different handedness interact with desktop touchscreen displays and how the hand usage pattern influences their body discomfort development. Twenty-one participants in three different handedness groups conducted simple web-browsing for 30 minutes using a 23″ touchscreen display while their subjective body discomfort, frequency of use of each hand and touch area preference were periodically quantified. Participants reported a gradual increase in body discomfort during web-browsing, and the increments in body discomfort varied between handedness groups for some body parts. Results also show that right-handed participants had stronger laterality than the left-handed, and ambidextrous participants used both hands more evenly than other participants, suggesting associations between the hand usage pattern and body discomfort development. Findings of the current study suggest that body discomfort of desktop touchscreen display users could be moderated by user-interface improvements and user training.

Practitioner Summary: Body discomfort development of desktop touchscreen users may be influenced by their hand usage pattern. Findings of this laboratory study suggest that user discomfort may be moderated by placing menu items in the lower area within the display or training users to alternate hands when conducting touch gestures.  相似文献   


16.
《Ergonomics》2012,55(7):1167-1179
This study investigated the impact of weight magnitude and distribution of body armour and carrying loads on military personnel's walking patterns and comfort perceptions. Spatio-temporal parameters of walking, plantar pressure and contact area were measured while seven healthy male right-handed military students wore seven different garments of varying weight (0.06, 9, 18 and 27 kg) and load distribution (balanced and unbalanced, on the front and back torso). Higher weight increased the foot contact time with the floor. In particular, weight placement on the non-dominant side of the front torso resulted in the greatest stance phase and double support. Increased plantar pressure and contact area observed during heavier loads entail increased impact forces, which can cause overuse injuries and foot blisters. Participants reported increasingly disagreeable pressure and strain in the shoulder, neck and lower back during heavier weight conditions and unnatural walking while wearing unbalanced weight distributed loads. This study shows the potentially synergistic impact of wearing body armour vest with differential loads on body movement and comfort perception.

Practitioner Summary: This study found that soldiers should balance loads, avoiding load placement on the non-dominant side front torso, thus minimising mobility restriction and potential injury risk. Implications for armour vest design modifications can also be found in the results.  相似文献   

17.
《Ergonomics》2012,55(5-6):677-692
Abstract

In order to evaluate sitting comfort qualitatively, a flexible and very thin sensor was developed to measure the contact shape between a seated man and the seal surface. Each tape has twenty strain guages on it at regular intervals, and the fourteen tape sensors were arranged on the bottom and back surface of the experimental driver's seat. The contact shapes and postures in thirty two male drivers were measured with two types of seal cushion and sitting posture: free and recommended. Sensory evaluation was made for each experimental condition. The results of the interrelation between the characteristics of the surface deformation, the parameters of body build, sitting posture and feeling of comfort shows that the comfort of each morphological fitting does not correspond to one special and single parameter from those physical factors, but is represented by a function with many parameters related to the deformation, posture and body build. By using these relations, a sensory model for the prediction of the sitting comfort was constructed.  相似文献   

18.
《Ergonomics》2012,55(5):853-863
Abstract

We examined the effects of posture, weight and frequency on trunk muscular activity and fatigue during repetitive dynamic lifting. Electromyographic (EMG) signals from eight primary trunk muscles were collected during 120 min for four different task conditions. The patterns of muscle recruitment and the levels of relative activation were analysed using the normalized EMG data. Median power frequency (MPF) shift patterns were analysed to examine muscular fatigue. The muscles in the dorsal part of the trunk were activated at the symmetric posture, while the muscles on the contralateral side to the workload were more strongly activated at the asymmetric posture. Decreasing trends of MPFs were found in some active muscles, and they were more pronounced for the asymmetric posture than for the symmetric posture. It was also seen that the muscles became fatigued faster for the light load-high frequency task than for the heavy load-low frequency task.  相似文献   

19.
The aims of this study were to propose multiply scale factors for evaluation of discomfort of standing persons and to investigate whether there exist differences between multiplying factors used for evaluation of discomfort of standing persons and those of seated persons exposed to WBV. Twelve male subjects were exposed to twenty-seven stimuli that comprise three acceleration magnitudes (0.2, 0.4, and 0.8 m/s2 r.m.s.) along fore-aft (x), lateral (y) or vertical (z) direction. The subjects with seated or standing posture on the platform of the vibration test rig rated the subjective discomfort for each stimulus that has frequency contents ranging from 1.0 Hz to 20 Hz with a constant power spectrum density. The order of presentation of the test stimuli was fully randomized and each stimulus was repeated three times. The subjective scale for discomfort was calculated by using the category judgment method. The best combinations of multiplying factors were determined by calculating correlation coefficients of regression curves in-between subjective ratings and vibration magnitudes. In all the directions, body posture significantly influenced on subjective discomfort scales. Particularly in the fore-aft and lateral direction, the upper limit of all the categories for the standing posture resulted in higher vibration acceleration magnitudes than those for the seated posture. In contrast, in the vertical direction, only the upper limit of category “1: Not uncomfortable” for standing posture was observed to be higher than that for seated posture. The best agreement for ISO-weighted vibration acceleration occurred at x factor of 1.8 and y factor of 1.8 in the standing posture and x factor of 2.8 and y factor of 1.8 in the seated posture. The results suggest that seated people respond more sensitively and severely in perception of discomfort to fore-aft and lateral vibration than standing people do while standing people respond more sensitively and severely to vertical vibration than seated people do. Thus the effects of body postures on multiplying factors should be considered in evaluation of discomfort caused by whole-body vibration.Relevance to industryThis study reports differences in subjective response of standing persons to fore-aft, lateral and vertical whole-body vibration. The results obtained in this study propose the fundamental data on the sensitivity to whole-body vibration exposed with standing posture.  相似文献   

20.
《Ergonomics》2012,55(5):842-855
This study was carried out to investigate the influence of the body posture and of the foot support on the apparent mass distribution at the feet of standing subjects exposed to whole-body vibration. The apparent mass was measured at the driving point through a capacitive pressure sensor matrix, which allowed to separate the contributions of the different foot regions. The overall value was also determined using a conventional measurement system based on piezoelectric load cells. Ten male subjects performed 15 tests with three kinds of feet supports (flat rigid, anatomic rigid and flat soft) in five different postures. Static components of the pressure measurements were exploited to identify which fraction of the weight is supported by the rearfoot, the midfoot and the forefoot in the various test configurations. Factorial design of experiments on different response variables showed that the apparent mass is affected by the posture but not by the type of feet contact surface; conversely, the presence of insoles varies with the apparent mass distribution on the different feet parts.

Practitioner Summary: The response of standing subjects to whole-body vibration has always been considered as a global parameter measured at the driving point, neglecting the local phenomena occurring in different foot parts. We have experimentally identified the apparent mass distribution of subjects in different standing postures and with different foot supports.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号