首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Forced convective heat transfer on the impinged plate associated with swirling impinging jets (SIJ) issuing from nozzles inserted by twisted tapes has been investigated. Swirling impingement jets with several swirl rates were generated by twisted tapes at different twist ratios (y/W = 3, 4, 5, and 6). The experiments were performed by locating nozzle at 4 different jet-to-plate spacings of L/D = 2, 4, 6 and 8. A jet Reynolds number varied between 4000 and 16000. Attributing to a high momentum transfer rate, an efficient heat transfer was obtained by using the jet with a small jet-to-plate spacing and the twist tape with a large twist ratio at high Reynolds number. At small jet-to-plate spacings (L/D = 2 and 4), swirling impinging jets gave higher heat transfer rate than conventional impinging jets while at large jet-to-plate spacings (L/D = 6 and 8), the opposed result was obtained. Over the range examined, only SIJ induced by the twisted tape at a twist ratio of 6 consistently provided higher average Nusselt numbers than CIJ.  相似文献   

2.
The flow and heat transfer characteristics of multiple swirling impinging jets (M-SIJs) with 3 × 3 in-line arrangement, on impinged surfaces are reported. The experiments were conducted with four different jet-to-jet distances (S/D = 2, 4, 6 and 8) at the constant nozzle-to-plate distance of L/D = 4. The swirling jets with the swirl numbers of 0.4 were associated with twisted tapes. The multiple conventional impinging jets (M-CIJs) were also tested, for comparison. The flow patterns on an impinged surface were visualized using oil film technique while the distributions of temperature field and Nusselt number on impinged surface were evaluated via a thermochromic liquid crystal (TLC) sheet coupled with image processing technique. The experimental results showed that the M-SIJs offered higher heat transfer rate on impinged surfaces than the M-CIJs of all jet-to-jet distances (S/D).  相似文献   

3.
An experimental study on heat transfer and fluid flow has been carried out for a swirling round impinging jet. A thermosensitive liquid crystal sheet was used for the heat transfer measurements and the three velocity components were measured with LDV in the stagnation region for cases where the Swirl number Sw = 0.0, 0.22, and 0.45 at the Reynolds number Re = 8100. The formation of recirculation flow due to a swirl near the impinging wall was found to deteriorate the heat transfer coefficient in the stagnation region and results in a more uniform distribution of the Nusselt number with an increasing Swirl number. The heat transfer mechanism of the swirling impinging jet is discussed based on the flow characteristics of the mean velocities and turbulence quantities. © 2005 Wiley Periodicals, Inc. Heat Trans Asian Res, 34(5): 324–335, 2005; Published online in Wiley InterScience ( www.interscience. wiley.com ). DOI 10.1002/htj.20068  相似文献   

4.
Heat transfer and flow visualization experiments were conducted to investigate the performance of swirling and multi‐channel impinging jets and compare the results with those of a multi‐channel impinging jet (MCIJ) and conventional impinging jet (CIJ) for the present work at the same conditions. Swirling impinging jets (SIJs) employed the fixed blade lengths of 12.3 mm with four blades at the exit of the housing tube to divert the air flow through four narrow channels with a desired swirl angle (θ of 22.5, 41 and 50°). The MCIJ jet had the same dimensions as the SIJs, except that the narrow channels in the solid insert were vertical (θ=0°). The local and surface average Nusselt numbers of MCIJ were generally higher than those of the CIJ and SIJs. The SIJs, however, demonstrated significant improvement in radial uniformity of heat transfer compared to the MCIJ and CIJ. In the region of 2.7?X/D?0 for H/D=8 and Re=20 000, the average Nusselt number for the MCIJ was 11, 33, 72 and 98 per cent higher than that of the CIJ, θ=22.5, θ=41 and θ=50°, respectively. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

5.
The aim of this research is to enhance the heat transfer on an impinged surface under an impinging jet array by minimizing a cross-flow effect. Conventional round orifices (aspect ratio, AR = 1) are substituted by the elongated orifices with aspect ratio AR = 4 and 8 with the same jet exit area. Two types of orifice arrangements; in-line and staggered arrays are compared. The experimental investigation was carried out at constant distance from orifice plate to impinged surface H = 2DE (DE is equivalent diameter of orifice). The heat transfer characteristic was visualized using thermochromic liquid crystal sheet (TLCs) and the Nusselt number distribution was evaluated by an image processing technique. The flow characteristic on the impinged surface was also visualized by oil film technique. The results show that the cross-flow in a case of the jets issued from the orifices with AR = 4 is considerably less significant than that in cases of the ones delivered from the orifices with AR = 1 and 8. At Reynolds number of 13,400, the Nusselt numbers for the jet arrays issued from the elongated orifices with AR = 4 with in-line and staggered arrangements are respectively 6.04% and 12.52% higher than those for the case of AR = 1.  相似文献   

6.
The thermohydraulic characteristics of the circular tubes equipped with alternate clockwise and counter-clockwise twisted-tapes (TA) for the Reynolds number ranging from 830 to 1990, are reported. In the experiments, the twisted tapes with three different twist ratios (y/W = 3, 4 and 5) were inserted individually into the uniform wall heat flux tubes where water was utilized as the working fluid. The plain tube and the tube inserted with twisted tape (TT) were also tested, for comparison. The obtained results reveal that, Nusselt number, friction factor and thermal performance factor associated by TA are higher than those associated by TT. Among the tapes examined, the one with the smallest twist ratio of y/W = 3 is found to be the most efficient for heat transfer enhancement. For the range studied, the applications of both TT and TA for heat transfer enhancement are found to be promising since the thermal performance factors determined under the same pumping power are all above unity. In addition, the empirical correlations for Nusselt number, friction factor and thermal performance factor have also been developed. The consequential results obtained from the correlations are found to be in good agreement with the experimental results within ± 8% variation for Nusselt number (Nu), ± 8% for thermal performance factor (η) and ± 5% for friction factor (f).  相似文献   

7.
圆形冲击射流传热性能的实验研究   总被引:5,自引:1,他引:5  
应用萘升华传质/传热比拟技术,对单个圆形射流在不同喷嘴到被冲击表面距离(1≤H/D≤12),在7×103≤R e≤1.9×104时,进行了局部传质/传热实验;研究了不同喷嘴到被冲击表面距离和不同R e对单个圆形射流局部换热特性的影响。单个圆形射流局部传热系数随着R e的增加而大幅度增加,R e是影响局部换热系数的主要因素。在同一R e下局部换热系数沿轴向非单调变化,在驻点处当H/D≌6时换热系数达到峰值;H/D<6时,局部换热系数沿径向有两个峰值;随H/D的增加,中心区局部N u减小,但影响范围变大。  相似文献   

8.
This experimental study performs the detailed heat transfer measurements of an impinging air-liquid nitrogen mist jet onto a superheated flat surface at atmospheric pressure with reference to the design of an instant freezing facility. A selection of experimental results illustrates the interacting effects of jet Reynolds number, mass flow ratio of air to liquid nitrogen flows and separation distance on the spatial distributions of heat transfer over the impinging surface. Mechanism associated with phase change of impacting droplets generates an enhanced and uniformly distributed heat transfer region centered on the stagnation point. A narrow oval-ring region encapsulating the enhanced core transits heat transfer from the wetting regime of complete evaporation to the non-wetting rebound regime. Stagnation heat transfer augmentation factor in the range of 1.2-2.8 times of the air-jet level is achieved. An empirical correlation based on the experimental data, which is physically consistent, has been developed to permit the evaluation of stagnation heat transfer.  相似文献   

9.
The article presents the application of a mathematical model for simulation of the swirling flow in a tube induced by loose-fit twisted tape insertion. Effects of the clearance ratio defined as ratio of clearance between the edge of tape and tube wall to tube diameter (CR = c/D = 0.0 (tight-fit), 0.1, 0.2 and 0.3) on heat transfer enhancement (Nu), friction factor (f) and thermal performance factor (η) are numerically investigated for twisted tapes at two different twist ratios (y/w = 2.5 and 5.0). The simulation is conducted in order to gain an understanding of physical behavior of the thermal and fluid flow in the tube fitted with loose-fit twisted tape under constant wall temperature conditions in the turbulent flow regime for the Reynolds number ranging from 3000 to 10,000. The Navier–Stokes equation in common with a energy equation is solved using the SIMPLE technique with the standard kε turbulence model, the Renormalized Group (RNG) kε turbulence model, the standard kω turbulence model, and Shear Stress Transport (SST) kω turbulence model. The numerical results show that the predictions of heat transfer (Nu) and friction factor (f) based on the SST kω turbulence models are in better agreement with Manglik and Bergles [R.M. Manglik, A.E. Bergles, Heat transfer and pressure drop correlations for twisted-tape inserts in isothermal tubes, part II: Transition and turbulent flows, Transaction ASME, Journal of Heat Transfer, 115 (1993) 890–896.] than other turbulence models. The mean flow patterns in a tube with loose-fit twisted tapes in terms of contour plots of velocity, pathline, pressure, temperature and turbulent kinetics energy (TKE) are presented and compared with those in a tube fitted with tight-fit twisted tapes. It is visible that the twisted tape inserts for y/w = 2.5 with CR = 0.0 (tight-fit), 0.1, 0.2 and 0.3 can enhance heat transfer rates up to 73.6%, 46.6%, 17.5% and 20%, respectively and increase friction factors up to 330%, 262%, 189%, and 160%, respectively, in comparison with those of the plain tube. The tube with loose-fit twisted tape inserts with CR = 0.1, 0.2 and 0.3 provide heat transfer enhancement around 15.6%, 33.3% and 31.6% lower than those with CR = 0.0 (the tight-fit twisted tape). The heat transfer augmentation is expected to involve the swirl flow formation between the tape and a tube wall. In addition, the simulation for thermal performance factor (η) of a tube with the loose-fit twisted tape and the tight-fit twisted tape under the same pumping power is also conducted, for comparison.  相似文献   

10.
An experimental study was performed to determine the effects of inclination of an impinging two dimensional slot jet on the heat transfer from a flat plate. Local Nusselt numbers and surface pressure distributions were determined depending on inclination angle, jet-to-plate spacing and Reynolds number. The results showed that the location of maximum heat transfer was mainly due to the angle of inclination. As the inclination angle increases, the location of the maximum heat transfer shifts towards the uphill side of the plate and the value of the maximum Nusselt number gradually increases at lower jet-to-plate spacings.  相似文献   

11.
This paper reports our works in the design and testing of a closed-loop electronics cooling system that adopts bi-technologies: single phase impinging jet and mini channels heat exchanger. The system has the cooling capacity of 200 W over a single chip with a hydraulic diameter of 12 mm. The equivalent heat flux is 177 W/cm2. The cooling system maintains the chip’s surface temperature below 95 °C maximum when the ambient temperature is 30 °C. De-ionized water is the working fluid of the system. For the impinging jet, two different nozzles are designed and tested. The hydraulic diameters (dN) are 0.5 mm and 0.8 mm. The corresponding volume flow rates are 280 mL/min and 348 mL/min. Mini channels heat exchanger has 6 (six) copper tubes with the inner diameter of 1.27 mm and the total length of about 1 m. The cooling system has a mini diaphragm pump and a DC electric fan with the maximum power consumptions of 8.4 W and 0.96 W respectively. The coefficient of performance of the system is 21.4.  相似文献   

12.
This paper is the second part of the experimental study on exploring the feasibility of inverse diffusion flame (IDF) for impingement heating. The structures and heat transfer characteristics of an impinging IDF jet have been studied. Four types of impinging flame structure have been identified and reported. The distributions of the wall static pressure are measured and presented. The influences of the global equivalence ratio (), the Reynolds number of the air jet (Reair), and the non-dimensional burner-to-plate distance (H/dair), on the flame structure, and the local and averaged heat transfer characteristics, are reported and discussed. The highest heat transfer occurs when the tip of the flame inner reaction zone impinges on the plate. The heat transfer rate from the impinging IDF is found to be higher than that in the premixed flame jet due to the augmented turbulence level originated from the flame neck. This high heat transfer rate, together with its in-born advantage of no danger of flashback and low level of nitrogen oxides emission, demonstrates the blue, dual-structured, triple-layered IDF is a desirable alternative for impingement heating.  相似文献   

13.
Impinging jets may be used to achieve enhanced local heat transfer for convective heating, cooling, or drying. The issuing jet may contact the surface normally or obliquely. Factors such as jet attachment, surface angle, jet angle and size, separation distance between jet orifice and surface of impingement, and trajectory influence heat transfer dramatically. This study addresses the thermal problem of jet impingement on an inclined surface and is motivated by the practical application of air jets issuing out of a defroster’s nozzles and impinging on the inclined windshield surface of a vehicle. The effects of incoming fluid velocity, openings’ geometry (circular vs. rectangular), number of openings, angle that the inclined surface makes with the horizontal plane and angle of impinging jet on heat transfer are examined. Fluid mechanics and heat transfer characteristics are exhibited in details for a configuration with three rectangular openings. A comparative study for other configurations is also featured. The results are correlated in terms of governing dimensionless parameters through numerically-based correlations that are useful for predicting heat transfer on an inclined surface subject to impinging airflow.  相似文献   

14.
Heat transfer, friction and thermal performance characteristics of CuO/water nanofluid have been experimentally investigated. The nanofluid was employed in a circular tube equipped with modified twisted tape with alternate axis (TA). The concentration of nanofluid was varied from 0.3 to 0.7% by volume while the twisted ratio (y/W) of TA was kept constant at 3. The experiments were performed in laminar regime (Reynolds number spanned 830 ≤ Re ≤ 1990). The uses of nanofluid together with typical twisted tape (TT), TA alone and TT alone were also examined. To evaluate heat transfer enhancement and the increase of friction factor, the Nusselt number and friction factor of the base fluid in the plain tube were employed as reference data. The obtained results reveal that Nusselt number increases with increasing Reynolds number and nanofluid concentration. By the individual uses of TA and TT, Nusselt numbers increase up to 12.8 and 7.2 times of the plain tube, respectively. The simultaneous use of nanofluid and TA improves Nusselt number up to 13.8 times of the plain tube. Over the range investigated, the maximum thermal performance factor of 5.53 is found with the simultaneous employment of the CuO/water nanofluid at 0.7% volume and the TA at Reynolds number of 1990. In addition, the empirical correlations for heat transfer coefficient, friction factor and thermal performance factor are also developed and reported.  相似文献   

15.
S. Jaisankar  K.N. Sheeba 《Solar Energy》2009,83(11):1943-1952
Experimental investigation of heat transfer, friction factor and thermal performance of twisted tape solar water heater with various twist ratios has been conducted and the results are compared with plain tube collector for the same operating conditions with Reynolds number varied from 3000 to 23,000. Experimental data from plain tube collector is validated with the fundamental equations and found that the discrepancy is less than ±5.35% and ±8.80% for Nusselt number and friction factor, respectively. Correlations have been developed for Nusselt number and friction factor with various twist ratios (Y = 3, 4, 5, 6) and are compared with the experimental values. Results conclude that, heat transfer and pressure drop are higher in twisted tape collector compared to the plain one. Among the various twist ratios, the minimum twist ratio 3 is found to enhance the heat transfer and pressure drop due to swirl generation. As the twist ratio increases, the swirl generation decreases and minimizes the heat transfer and friction factor.  相似文献   

16.
This work presents the design of an experimental set-up for swirling decaying flow investigations, alongside validation experiments and preliminary experimental work. The combinations of possible investigations using such an apparatus are limitless. As a means of validation, a series of flow visualisation images for pipe flow are presented. In addition to that, the design of the axial swirl vanes used in the study was also disclosed, alongside flow visualisation images and steady and unsteady heat transfer results. Experimental validation was conducted using the dye seeding method. Results show that the fully laminar and turbulent regime is similar to published results. Streak-lines produced for swirling decaying flow are clear and easily captured using normal digital cameras.  相似文献   

17.
Experimental and numerical investigation of heat transfer and fluid flow were conducted for classic heat exchanger elements (flat plate with fin-tubes in-line, staggered and with vortex generators) and corrugated-undulated ducts under transitional and weakly turbulent conditions.The dependence of average heat transfer and pressure drop on Reynolds number and geometrical parameters was investigated. Distributions of local heat transfer coefficient were obtained by using liquid crystal thermography and surface-averaged values were computed. Three-dimensional numerical simulations were conducted by a finite-volume method using a low-Reynolds number k-e model under the assumption of fully developed flow. Computed flow fields provided otherwise inaccessible information on the flow patterns and the mechanisms of heat transfer enhancement.  相似文献   

18.
This paper presents the mass transfer results from an impinging liquid jet to a rotating disk. The mass transfer coefficients were measured using the electrochemical limiting diffusion current technique (ELDCT). Rotational Reynolds number (Rer) in the range of 3.4 × 104–1.2 × 105, jet Reynolds number (Rej) 1.7 × 104–5.3 × 104 and non-dimensional jet-to-disk spacing (H/d) 2–8 were taken into consideration as parameters. It was found that the jet impingement resulted in a substantial enhancement in the mass transfer compared to the case of the rotating disk without jet.  相似文献   

19.
This paper will present the characteristics of flow behavior and thermal field of both free and
impingement jet issued from a circular orifice nozzle at Re=8900.The flow behavior of a single round
jet and impingement jet was observed by smoke flow visualization recorded by a high speed camera
using 5000 frame per second.Heat transfer coefficient on the impingement surface was measured by
means of infrared camera (TVS-8500,Avio) with a two-dimensional array of Indeum-Antimony (In Sb)
sensors varying in the separation distance between the nozzle and the target plate.The heat transfer
coefficient changes in time and spatial.Therefore,the root mean square distribution of the heat
transfer was obtained from the data.As a result,it was confirmed that the longitudinal vortex was
observed outside of the ring vortex,and then the longitudinal vortex was penetrated in the jet
flow.Moreover,the high value of root mean square of the heat transfer coefficient has spread radially
in stripy manner,which is caused as the results of the longitudinal vortexes flowing in the radial
direction on the impingement plate.  相似文献   

20.
对旋进射流冲击平板时的传热进行了实验研究。通过在圆筒套管内设置一块孔板构成旋进射流喷嘴,得到了持续稳定的旋进射流。对旋进射流的流动特性作了研究,给出了旋进射流的频率与尺寸、Re的关系。用两种不同孔径的旋进射流冲击一块加热平板,并与普通的射流冲击传热作对比。结果表明,由于旋进射流与流体混合作用加剧而大大地降低了流速,使得强化传热的效果减弱,这种趋势在驻点附近尤为明显。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号