首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
 Total reflection X-ray fluorescence spectrometry was applied for the certification of IAEA lichen-336. The elements Ca, Mn, Fe, Cu, Zn, Rb, Sr and Pb were determined simultaneously. The concentrations range from 1.8 mg/kg for Rb to 2360 mg/kg for Ca. The results were compared with those of other methods and laboratories having participated in this certification for the International Atomic Energy Agency (IAEA): emission spectrometry, mass spectrometry, atomic absorption spectrometry, X-ray spectrometry, neutron activation analysis and voltammetry. The results determined by TXRF are in good agreement with the overall means of accepted values and differ from the means by 1 to 10%. Received: 1 September 1996/Revised: 15 October 1996/Accepted: 22 October 1996  相似文献   

2.
Summary An investigation through interlaboratory comparison using different analytical techniques has been carried out in order to assess the suitability of a plasma protein solution as a source for a trace element reference material in clinical analysis. Reasonable agreement was obtained for a number of elements from the range studied: Al, Ba, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Se, Sr, V and Zn. The techniques used included flame and furnace atomic absorption spectrometry (FAAS and ETA-AAS), furnace atomic emission spectrometry (ETA-AES), inductively coupled plasma atomic emission spectrometry (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS), and simultaneous multi-element atomic absorption spectrometry (SIMAAC). Results indicated that this plasma protein solution may prove useful as a source for a reference material covering trace element levels outwith the range found in normal human plasma.
Humanalbumin als Referenzmaterial für Spurenelemente
  相似文献   

3.
为给芦蒿中微量元素的检测提供科学方法。采用浓硝酸微波消解法处理样品,用火焰原子吸收分光光度法和石墨炉法对芦蒿样品中的金属元素Fe、Cu、Zn、Mn、Ca、Pb的含量进行了测定。结果表明,方法的加样回收率为96.80%~103.04%。该法操作简单、结果准确,是芦蒿中微量元素检测的理想方法。  相似文献   

4.
原子吸收光谱法测定宁夏几种中草药中微量元素含量   总被引:1,自引:0,他引:1  
采用原子光谱法测定了宁夏几种野生中草药苦豆子、败酱草、老瓜头全草及根、茎、叶中Ca、Mg、Fe、Mn、Zn、Cu、Pb、Cd 8种元素的含量。结果表明,几种野生中草药Ca、Mg、Fe、Mn、Zn、Cu含量较为丰富,Pb含量低,Cd未检出,分析结果对几种中草药的辨证使用及其生长环境的研究具有一定的实际意义。  相似文献   

5.
Summary Preparation and development has been completed of ten agricultural/food reference materials (RMs): bovine muscle powder, corn starch, hard red spring wheat flour, soft winter wheat flour, whole milk powder, wheat gluten, corn bran, durum wheat flour, whole egg powder and microcrystalline cellulose. Homogeneity tests for 14 elements, Al, Ca, Cd, Co, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Sr and Zn were performed by the initiating laboratories by application of precise and reliable analytical methods based on flame atomic absorption spectrometry and graphite furnace atomic absorption spectrometry. An extensive set of analytical results obtained from the interlaboratory cooperative characterization campaign was assessed to provide homogeneity estimates for other elements. Estimates of homogeneity from within-laboratory precision indicated that all materials exhibited acceptable homogeneity for virtually all 29 elements (Al, As, B, Ba, Br, Ca, Cd, Cl, Co, Cr, Cu, Fe, Hg, I, K, Mg, Mn, Mo, N, Na, Ni, P, Pb, Rb, S, Se, Sr, V, Zn) for which best estimate concentration values are available. Two thirds of all homogeneity coefficients of variation were below 5%.  相似文献   

6.
三种蜂花粉中微量元素含量的测定分析   总被引:4,自引:0,他引:4  
采用火焰和石墨炉原子吸收光谱法对荞麦蜂花粉、茶花蜂花粉和莲花蜂花粉中的六种金属元素Fe、Cu、Zn、Mn、Ca、Pb的含量进行了测定。方法简单,精密度和灵敏度高,回收率为98.30%~93.51%,结果可靠。  相似文献   

7.
Djingova R  Zlateva B  Kuleff I 《Talanta》2004,63(3):785-789
The possibilities of inductively coupled plasma atomic mass spectrometry for determination of elemental composition of archaeological bones for reconstruction of paleodiet are discussed. The interferences of different polyatomic ions on the determination of Fe, Cu, Mg, Mn, Zn, and Zr are investigated and evaluated. Thus, a method for the determination of Al, As, Ba, Mg, Pb, Sr, V, Zn, and Zr is proposed and is validated by analysis of IAEA-SRM-H-5 (animal bone). The applicability of the proposed procedure is demonstrated analyzing real archaeological bone samples dated to 4th century b.c. and the results are compared with the data obtained by inductively coupled plasma atomic emission spectrometry.  相似文献   

8.
选用了中国宁夏中宁早康枸杞园林场生产的枸杞、山东省沾化金丝枣、山西柳林县红枣,用火焰原子吸收分光光度法[1]和石墨炉法对这三种样品中的金属元素Fe、Cu、Zn、Mn、Ca、Pb的含量进行了测定。测定方法简单,精密度和灵敏度高,回收率为105.1%~93.1%,结果可靠。  相似文献   

9.
Spark ablation has been combined to microwave plasma torch atomic emission spectrometry for the direct analysis of compact metallic samples. The material is ablated by a medium voltage spark (450 V, 370 Hz) in a point-to-plane configuration and swept into a 100-W, 2.45-GHz argon microwave discharge. The microwave plasma is observed end-on and the radiation analysed with a polychromator. The detection limits for Fe, Ni, Pb and Sn in brass, Cr, Cu, Ni, Mn, Mo, Si and V in steel and Cu, Fe, Mg, Mn, Si and Zn in aluminium with the microwave plasma torch in the case of measurements with a polychromator are in the μg/g range and by a factor of up to 20 higher than those obtained with spark ablation coupled to inductively coupled plasma atomic emission spectrometry using a high resolution sequential spectrometer. The stability of the emission signal depends on the element studied and relative standard deviations usually are between 0.5 and 3.5%. In the case of low-alloy steels, the linearity and the precision of the calibration could be improved by internal standardisation. Several elements (Cr, Cu, Ni, Si and V) could be determined in a steel sample (BAS SS 410/1) with high accuracy and precision.  相似文献   

10.
采用微波消解样品,运用电感耦合等离子体原子发射光谱法同时测定山药中K,Na,Ca,Mg,Zn,Fe,Cu,Mn,Se,Pb,Cd和Cr 12种元素。结果表明:方法简便、快速、准确;山药富含对人体有益的K,Ca,Fe,Mg,Zn,Mn,Se等矿物质元素,其肉质中重金属元素Pb,Cd,Cr含量均未超过国家食品卫生标准。  相似文献   

11.
刘晶  郑楚光  贾小红  徐杰英 《分析化学》2003,31(11):1360-1363
应用微波消解和电感耦合等离子体发射光谱法同时测定煤灰中的常量、少量和微量元素Si、Al、Ca、Fe、Mg、Ti、K、Ba、Mn、V、Pb、Cr、Cu和Zn。考察了微波消解体系和消解条件,0.1g煤灰用10mL硝酸和1mL氢氟酸分解,加入10mL4%硼酸溶液分解氟化物沉淀。用本法测定煤飞灰标准参考物质的结果与标准值一致。方法准确,快速,回收率为94.2%~102.3%;RSD均小于5%。  相似文献   

12.
Eight elements in NBS-SRM 1577 bovine liver and other biological standards are determined by flame atomic absorption (Ca, Cu, Fe, Mg, Mn and Zn) and emission (K and Na) spectrometry. Samples (2 mg) weighed into a 3.8-ml teflon vessel are decomposed with 40 μl of (5 ÷ 1) nitric—perchloric acids in a sealed teflon vessel. A 75-μl or 100-μl aliquot of the diluted sample solution is injected into a small teflon funnel coupled directly to the nebulizer needle of the spectrometer. The results obtained agree well with certified values: the standard deviation is about 2%.  相似文献   

13.
14.
建立电感耦合等离子体原子发射光谱(ICP–AES)测定锑铍芯块中铅、铁、锰和镁杂质元素的方法。对溶液酸度的选择、光谱和基体干扰等进行了试验和讨论,在优化仪器工作参数的条件下,通过基体匹配,有效消除了基体干扰的影响。铅、铁、锰、镁的质量浓度在0.05~10.0μg/mL范围内与其光谱强度呈良好的线性关系,线性相关系数大于0.999。铅、铁、锰、镁的检出限在0.5~5.3μg/L之间,测定结果的相对标准偏差为0.9%~2.9%(n=7),加标回收率为92%~106%。电感耦合等离子体原子发射光谱法与原子吸收光谱法对照,测定结果相符合。该方法准确可靠,可用于锑铍芯块中铅、铁、锰和镁杂质元素的测定。  相似文献   

15.
A procedure for the complete chemical analysis of magnesium or sodium diuranate (yellow cake) sample is reported. Uranium is determined gravimetrically after peroxide precipitation. Optimum parameters, such as pH, quantity of hydrogen peroxide, volume of sample, temperature and complexing agent for quantitave precipitation of uranium, and effective separation of other elements were studied. Aluminum, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, and Zn were determined by flame atomic absorption spectrometer and B, Mo, SO4, REEs and Y by inductively coupled plasma atomic emission spectrometer in the filtrates of hydroxide and peroxide precipitation separation. The proposed method is accurate and the precision is characterized by an RSD of ~0.2% for U; 2 to 6% for Mg, Na, K, Ca, Fe, SiO2, Al, Cd, Co, Cr, Fe, Mn, Ni, Pb, and Zn and 3 to7% for REEs, Y, Mo and B  相似文献   

16.
Kubová J  Matús P  Bujdos M  Hagarová I  Medved' J 《Talanta》2008,75(4):1110-1122
The prediction of soil metal phytoavailability using the chemical extractions is a conventional approach routinely used in soil testing. The adequacy of such soil tests for this purpose is commonly assessed through a comparison of extraction results with metal contents in relevant plants. In this work, the fractions of selected risk metals (Al, As, Cd, Cu, Fe, Mn, Ni, Pb, Zn) that can be taken up by various plants were obtained by optimized BCR (Community Bureau of Reference) three-step sequential extraction procedure (SEP) and by single 0.5 mol L(-1) HCl extraction. These procedures were validated using five soil and sediment reference materials (SRM 2710, SRM 2711, CRM 483, CRM 701, SRM RTH 912) and applied to significantly different acidified soils for the fractionation of studied metals. The new indicative values of Al, Cd, Cu, Fe, Mn, P, Pb and Zn fractional concentrations for these reference materials were obtained by the dilute HCl single extraction. The influence of various soil genesis, content of essential elements (Ca, Mg, K, P) and different anthropogenic sources of acidification on extraction yields of individual risk metal fractions was investigated. The concentrations of studied elements were determined by atomic spectrometry methods (flame, graphite furnace and hydride generation atomic absorption spectrometry and inductively coupled plasma optical emission spectrometry). It can be concluded that the data of extraction yields from first BCR SEP acid extractable step and soil-plant transfer coefficients can be applied to the prediction of qualitative mobility of selected risk metals in different soil systems.  相似文献   

17.
Summary Ten agricultural/food reference materials (RM): bovine muscle powder, corn starch, hard red spring wheat flour, soft winter wheat flour, whole milk powder, wheat gluten, corn bran, Durum wheat flour, whole egg powder and microcystalline cellulose, were prepared by milling, irradiation, sieving, blending and packaging procedures. Homogeneity tests for 14 elements in randomly selected units were performed by the initiating laboratories by application of various analytical methods. Al, Ca, Cu, Fe, K, Mg, Mn, Na, Sr and Zn were determined by acid digestion flame atomic absorption spectrometry, and Cd, Co, Ni and Pb using acid digestion graphite furnace atomic absorption spectrometry after separation/preconcentration of the analytes by co-precipitation. In addition, the extensive set of analytical results obtained from the interlaboratory cooperative characterization campaign was assessed to provide homogeneity estimates for other elements. Measures of homogeneity were estimated from the within-laboratory precision from the more precise laboratories. All materials exhibited acceptable homogeneity for virtually all 29 elements (Al, As, B, Ba, Br, Ca, Cd, Cl, Co, Cr, Cu, Fe, Hg, I, K, Mg, Mn, Mo, N, Na, Ni, P, Pb, Rb, S, Se, Sr, V, Zn) for which best estimate concentration values were available, an essential pre-requisite in establishing reference values for these materials. Sixty-two percent of all homogeneity coefficients of variation (CV) were below 5%, with Br, Ca, Cl, Mg, Na, P, Zn and especially K and N exhibiting very high homogeneity CV less than 1% in some cases.Contribution no. 92–148 from Centre for Land and Biological Resources Research  相似文献   

18.
PTS, PM10 and PM2.5 samples have been collected at a rural site of south-east Italy (40 degrees 20' 13" N; 18 degrees 6' 47" E) from June to October, 2004 to investigate natural and anthropogenic contributions on particulate matter and heavy metal mass concentrations. It is shown that sharp-peak particulate-matter concentrations have been recorded during most African dust outbreaks occurred over south-east Italy. In particular, PM10 concentrations exceeding the 24-hour limit value of 50 microg/m3 have been monitored during dust events. Al, Cd, Cr, Cu, Fe, Mn, V, Ni, Pb, and Zn metal concentrations have been evaluated by an inductively coupled plasma atomic emission spectrometer and Al mass concentrations >500 ng/m3 have been observed in PTS and PM10 samples during the advection of African dust particles. Accordingly to geochemical calculations Al, Fe, and Mn, have a significant crustal origin while, Cd, Cu, Pb, and Zn are of anthropogenic origin. Moreover, Fe resulted predominant in the coarse particle fraction, while Ni, Pb, V, and Zn were predominant in the fine particle fraction. It is also shown that Cd, Mn, Ni, Pb, and V concentrations never exceeded guide and/or limit values recommended by the World Health Organization and the European Council Directives.  相似文献   

19.
In this work, tungsten coil (W-Coil) devices are used as atomizers for electrothermal atomization atomic absorption spectrometry (ETAAS), electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS), and electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES). For most cases in ETAAS and ETA-LEAFS, limits of detection (LODs) using the W-Coil are within a factor of ten of those observed with commercial graphite furnace systems. LOD for Cd by W-Coil AAS is 10 pg, while LODs for As, Se, Cr, Sb and Pb by W-Coil LEAFS are 950, 320, 1400, 330, and 160 fg, respectively. The compact W-Coil device makes it an ideal atomizer for portable atomic spectrometry instrumentation, especially when coupled with a miniature charge coupled device spectrometer. Alternatively, the atomizer can be used as an inexpensive, modular add-on to an existing commercial ICP-AES system; and the thermal separation of Pb with interference elements Al, Mn, and Fe is demonstrated.  相似文献   

20.
A certified reference material (CRM) for trace elements in tea leaves has been developed in National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder (<90 μm) after frozen pulverization of washed and dried fresh tea leaves from a tea plant farm in Shizuoka Prefecture, Japan. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), high-resolution (HR-) ICP-MS, isotope-dilution (ID-) ICP-MS, inductively coupled plasma optical emission spectrometry (ICP-OES), graphite-furnace atomic-absorption spectrometry (GF-AAS) and flame atomic-absorption spectrometry (FAAS). Property values were provided for 19 elements (Ca, K, Mg, P, Al, B, Ba, Cd, Cu, Fe, Li, Mn, Na, Ni, Pb, Rb, Sr, Zn and Co) and informative values for 18 elements (Ti, V, Cr, Y, and all of the lanthanides, except for Pm whose isotopes are exclusively radioactive). The concentration ranges of property values and informative values were from 1.59% (mass) of K to 0.0139 mg kg(-1) of Cd and from 0.6 mg kg(-1) of Ti to 0.0014 mg kg(-1) of Lu, respectively. Combined relatively standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, analytical methods, characterization, calibration standard, and dry-mass correction factor. The range of the relative combined standard uncertainties was from 1.5% of Mg and K to 4.1% of Cd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号