M.Koch  M.Krtiger 《高电压技术》2009,35(8):1933-1939
This paper discusses approaches to measure moisture in power transformers by analyzing the dielectric response of the main insulation. Dielectric diagnostic methods deduce moisture in the solid insulation from dielectric properties like polarisation depolarisation currents and dissipation factor vs. frequency. A new instrument "Dirana" combines time domain (PDC) and frequency domain (FDS) measurements and thus substantially shortens the measurement duration. New software was developed which bases on a new data pool,measured at new and aged pressboard samples with various moisture contents and oil impregnation. Its analysis algorithm compares measurements from a transformer to modelled dielectric responses,obtained from the so-called XY-model. To avoid overestimation of moisture for aged transformers,the analysis algorithm compensates for the influence of conductive aging by-products. Moisture especially increases the losses in the low frequency range of the dielectric response of pressboard. Thus,data on the left-hand side of the area dominated by interfacial polarization (insulation geometry) are required for reliable moisture determination. Case studies illustrate the application of moisture determination by dielectric response methods.  相似文献   

2.
介绍了动态对角递归网络,并针对BP算法收敛慢的缺点,提出了递推预报误差学习算法.利用该算法对神经网络的权值和域值进行训练,有效地提高神经网络的收敛性及增量学习能力.将动态对角递归网络应用到变压器的故障诊断中,利用改良三比值方法来实现诊断,建立了诊断的模型.利用部分数据进行了训练及故障诊断的仿真,结果表明了利用该方法进行变压器故障诊断的有效性.  相似文献   

3.
以油浸式电力变压器为研究对象,提出基于物元-时域分析的电力变压器状态评估方法,构造各评估指标的关联函数,函数值在正常运行量值范围内为正,在由量变发展到质变时函数值取负,并且根据评估值在时域上累计描绘出变压器状态评估时域曲线,且可以根据一定要求剔除因监测系统问题出现的离散数据,使得收集的评估数据更准确。  相似文献   

4.
介绍油浸式电力变压器油纸绝缘系统的介电响应模型,分析回复电压法、极化/去极化电流法、频域谱测量法3种非破坏性变压器老化状态的评估方法,为油浸式电力变压器老化状态评估工作提供参考.  相似文献   

5.
频域谱技术用于油浸式电力变压器绝缘状态现场诊断   总被引:2,自引:4,他引:2  
张致  董明  杨双锁  姜惟  张冠军  严璋 《高电压技术》2009,35(7):1648-1653
为了提高大型油浸式电力变压器的运行可靠性,提出了基于频域谱技术进行油浸式变压器绝缘状态及老化诊断的方法,利用该方法对国内某220kV变压器进行了测量,得到了其检修前后绝缘系统的介损频率特性曲线,并将频域谱测量方法与预防性试验数据进行了对比,验证了二者在变压器电容测量上的一致性。试验表明,频域谱方法可以反映变压器内部绝缘状态,估计固体绝缘中的含水量,为绝缘诊断提供参考信息;频域谱技术是一种无损试验方法,可作为现有绝缘诊断方法的重要补充,具有良好的应用前景。  相似文献   

6.
油浸式电力变压器中的油纸绝缘系统受潮会加速固体绝缘材料老化,严重影响其运行寿命,因此评估变压器绝缘纸板中的水份含量对确保变压器安全可靠运行具有重要意义.基于回复电压的极化谱方法是一种无损的绝缘诊断方法,已经被用来评估变压器的绝缘状态.笔者研究了不同充电时间下水份含量变化对回复电压参数的影响规律.结果表明,回复电压最大值...  相似文献   

7.
Abstract—Insulating oil replacement is one of the most commonly used measures to solve oil deterioration in field transformers. However, the effects of oil replacement upon transformer condition assessment are still unknown. This article presents a simulated oil replacement in the process of an accelerated thermal aging test. The accelerated thermal aging experiment was conducted at 130°C for 80 days; insulating oil was replaced on the 25th day of aging. Several common condition assessment methods, including degree of polymerization of the paper, oil acidity, dielectric strength of the oil–paper insulation, moisture estimation, and furfural analysis, were compared before and after oil replacement. Results showed that oil replacement is effective in solving the degradation of insulating oil but not in restraining the aging of paper. The variation of dielectric strength of insulation paper caused by oil replacement could be neglected. Moisture estimation of insulation paper was closely related to the aging degree of oil–paper insulation but not obviously influenced by oil replacement. Furfural analysis would be seriously affected by oil replacement because furfural in oil was eliminated during the oil-drainage process, so the effect of oil replacement should be corrected when estimating transformer aging condition with furfural analysis method.  相似文献   

8.
由于固体绝缘具有不可恢复的老化特性,其性能状态对变压器的运行寿命及维护策略有着重要的影响。本文分析了影响固体绝缘老化的各种因素以及目前诊断方法的优缺点,重点阐述了极化去极化电流法和恢复电压法,二者从变压器绝缘系统的电路模型入手,以介质响应理论为基础,通过极化特性曲线和相关参数的分析得到变压器固体绝缘状态的可靠信息。现场试验数据表明了测量结果与聚合度、糠醛分析法的一致性,因此介质响应分析法可以作为一条简单有效的途径实现变压器固体绝缘性能的无损检测,建议在电力设备运行维护单位广泛开展。  相似文献   

9.
张斌  张涛  于洁  张晓林 《江苏电器》2016,(10):39-42
回复电压法(RVM)是一种无损的评估变压器油纸绝缘状态的方法。基于回复电压测量原理,利用可编程控制的6517B静电仪,在VB软件开发平台下,研制了一套回复电压采集系统。该系统能够自动地测量不同充电时间的回复电压,绘制出回复电压极化谱并对其特征量进行提取。对该系统的性能进行实验测试并分析了不同实验因素对极化谱的影响,结果表明,该系统准确测量出回复电压,并获得了残余电荷最佳消除时间K30放电裕度。  相似文献   

10.
采用回复电压法分析油纸绝缘老化特征量   总被引:4,自引:3,他引:1  
为将回复电压法用于电力变压器绝缘老化状态的无损诊断,通过实验室加速热老化实验,研究了不同老化程度下油纸绝缘回复电压各参数(回复电压最大值、初始斜率、中心时间常数)的变化规律;考虑到水分对回复电压参数的影响,亦对比分析了老化油纸绝缘试品干燥处理前后回复电压参数的变化.在原有回复电压参数的基础上,提出了一种新的可用于评估油...  相似文献   

11.
针对供电型电压互感器供电电压随负荷而变化的实际情况,介绍了一种基于辅助互感器串联补偿技术的供电电压补偿方法。以一台额定一次电压为110√3 kV,额定容量为60 kV·A的单相供电型电压互感器为例,计算了其供电电压及供电容量随负荷容量及功率因数的变化率。依据变化率,设计了基于辅助互感器的供电电压自动补偿回路,可实现对供电电压±4.4 V、±8.8 V、±13.2 V、±17.6 V、±22.0 V、±26.4及±30.8 V的补偿量。分别对功率因数cos φ=1和cos φ=0.89(感性)2种情况的不同负荷容量下供电电压补偿效果进行验证,试验结果表明:增加了辅助互感器自动串联补偿回路后,供电型电压互感器的供电电压变化率由–1.80%~11.36%提高到了–3.000%~0.045%,完全满足标准对单相220 V供电电压质量的要求。采用辅助互感器的自动串联补偿技术,可以实现对供电型电压互感器供电电压的补偿,解决了由于农村负荷功率因数低,高峰负荷期供电电压偏低的问题,对提高用户电压质量提供了保障。  相似文献   

12.
文章介绍了3种介质诊断方法,即回复电压法(RVM)、极化去极化电流法(PDC)和频域谱法(FDS),以及3种方法测量结果的比对,并介绍了这些方法的优缺点和改进措施。  相似文献   

13.
变压器状态检修技术及其应用   总被引:1,自引:0,他引:1  
通过对近几年来变压器的可用系数情况开始,分析了采取变压器状态检修的重大意义,目前国内外进行状态检修的主要方法以及状态检修的流程。通过列举故障实例阐述了状态检修对比于故障检修和定期检修的优势和现实意义。  相似文献   