1.
目的:观察双眼存在不同程度角膜散光的白内障患者分别植入多焦点人工晶状体、散光人工晶状体的临床效果。

方法:观察组为年龄相关性白内障患者20例40眼,术前角膜规则散光一眼1.50~2.50(平均2.15±0.87)D,植入散光晶状体,另一眼角膜散光<1.50D,平均0.78±0.26D,植入多焦点人工晶状体(MIOL)。对照组为同期双眼均植入MIOL的20例40眼年龄相关性白内障患者,规则角膜散光≤1.00D,平均0.62±0.34D。比较术后3mo观察组的散光晶状体眼与MIOL眼的远近裸眼视力及对照组与观察组患者双眼合视的远近裸眼视力。

结果:观察组患者Toric人工晶状体眼的裸眼远、近视力分别为0.81±0.32和0.58±0.27,MIOL眼远、近视力分别为0.76±0.28和0.67±0.24,两眼间差异无统计学意义(t=0.797,P>0.05; t=1.243,P>0.05); 观察组双眼合视的远近视力分别为0.90±0.33和0.79±0.22,对照组双眼合视的远近视力分别为0.92±0.25和0.85±0.28,两者比较差异无统计学意义(t=0.601,P>0.05; t=0.875,P>0.05)。

结论:双眼存在程度不同角膜散光的白内障患者,一眼植入多焦点人工晶状体、另眼植入散光人工晶状体同样可以提高患者术后的脱镜率。  相似文献   


2.

目的:比较主视眼植入单焦点人工晶状体(SIOL)、对侧非主视眼植入多焦点人工晶状体(MIOL)和双眼均植入SIOL的临床疗效。

方法:选取2019-01/2021-01于成都爱尔眼科医院行白内障超声乳化联合IOL植入术的年龄相关性白内障患者60例120眼,主视眼均已植入SIOL,根据对侧非主视眼植入IOL的类型分为三组,其中A组患者18例36眼非主视眼植入MIOL(SBL-3); B组患者19例38眼非主视眼植入MIOL(SN6AD1); 对照组23例46眼双眼均植入SIOL。术后3mo,评估并比较三组患者双眼视力及视觉质量。

结果:术后3mo,三组患者双眼裸眼和矫正远视力、裸眼中视力及矫正近视力均无差异(P>0.05),A组和B组患者双眼裸眼近视力和矫正中视力均显著优于对照组(P<0.05)。Catquest 9SF-CN量表评分显示,A组和B组患者(11.11±1.323、11.89±1.883分)视觉质量均优于对照组(14.65±1.722分,均P<0.05)。A组、B组和对照组患者脱镜率分别为88.9%、84.2%、39.1%,A组患者脱镜率显著高于对照组(P<0.0167)。

结论:白内障患者主视眼植入SIOL、对侧非主视眼植入MIOL(SBL-3/SN6AD1)可获得较双眼均植入SIOL更优的全程视力,术后不良视觉症状少,脱镜率及满意度高。  相似文献   


3.

目的:分析白内障超声乳化吸出并散光矫正型多焦点人工晶状体(IOL)植入术对白内障患者角膜散光及视觉质量的影响。

方法:将2016-12/2018-02因白内障于我院进行眼科手术治疗的95例95眼患者作为研究对象。对所有对象进行随机分组对比研究,两组均行白内障超声乳化吸出术治疗,对照组联合散光矫正型单焦点人工晶状体植入术治疗; 观察组联合散光矫正型多焦点人工晶状体植入术治疗。对比两组角膜散光、视觉质量及视力改善程度的差异。

结果:随访3mo,两组治疗后非矫正远视力、最佳矫正远视力、非矫正近视力及最佳矫正近视力均显著改善,观察组改善程度显著高于对照组(P<0.05); 治疗后两组角膜散光情况显著改善(P<0.05),组间改善程度无显著差异(P>0.05); 治疗后两组视觉对比敏感度均显著升高(P<0.05),观察组18c/d空间频率下视觉对比度显著低于对照组(P<0.01)。术后1d,观察组患者仅2眼出现角膜内皮水肿,对照组患者仅1眼出现角膜内皮水肿,观察组与对照组并发症发生率无显著差异(P>0.05)。

结论:超声乳化吸出并散光矫正型多焦点IOL植入术治疗白内障,可有效矫正视力,降低角膜散光,提高其视觉对比度,整个手术治疗过程安全性较高,术后并发症少。  相似文献   


4.
邓国华  周栋  徐淑贤 《国际眼科杂志》2015,15(11):1920-1922
目的:探讨Toric人工晶状体植入治疗白内障合并角膜散光的临床疗效。

方法:选择2013-06/2014-07在我院进行超声乳化白内障吸出及人工晶状体植入术合并角膜散光的白内障患者38例46眼作为研究对象,其中20例24眼患者植入Toric人工晶状体,18例22眼患者植入Acrysof IQ人工晶状体,对两组患者的临床疗效进行分析。

结果:两组患者术后裸眼视力进行比较,差异有统计学意义(F=5.783,P<0.05); 观察组患者术后1wk,1、3mo裸眼视力明显高于术前,其差异均有统计学意义(P<0.05); 观察组患者术后裸眼视力明显高于对照组,其差异有统计学意义(t=5.248,2.573,2.782; P均<0.05)。两组患者术后散光情况进行比较,差异有统计学意义(F=5.482,P<0.05); 观察组患者术后1wk,1、3mo的散光改善情况明显优于手术前,其差异有统计学意义(P<0.05); 观察组患者术后散光改善情况明显优于对照组,其差异有统计学意义(t=6.591、3.287、2.167,P均<0.05)。远视力研究中植入Toric人工晶状体有75%的患者不需要配戴眼镜。

结论:Toric人工晶状体植入治疗白内障合并角膜散光具有良好的矫正作用,且能明显提高患者术后视觉治疗,有良好的预测性,因此值得在临床推广应用。  相似文献   


5.
目的:评价Acrysof IQReSTORE+3D非球面衍射型多焦点人工晶状体植入术后临床效果。

方法:选择老年性白内障患者44例55眼,行白内障超声乳化手术并按患者意愿植入传统单焦点人工晶状体或多焦点人工晶状体。多焦点人工晶状体组(multifocal intraocular lens, MIOL):植入Acrysof IQReSTORE+3D,21例27眼; 传统单焦点人工晶状体组(monofocal intraocular lens, MoIOL):植入Abbott Sensar,23例28眼,所有患者均无影响术后视力的其他眼部疾病。观察两组患者术后3mo裸眼远视力、裸眼近视力、最佳矫正远视力、最佳矫正近视力、眼压、脱镜率、视觉症状、患者自觉舒适满意评价。

结果:MIOL裸眼近视力、脱镜率、视觉症状、患者自觉舒适满意评价均优于MoIOL(P<0.05),眼压变化两组比较无明显差异(P<0.05)。

结论:白内障超声乳化手术并植入多焦点人工晶状体后,与传统单焦点人工晶状体相比,前者能提供令人满意地远、中、近视力,患者能获得较高的视觉质量,满意程度高,双眼植入者效果更理想。  相似文献   


6.
王骞  朱俊英  肖燕  陈鹏 《国际眼科杂志》2014,14(9):1618-1619
目的:评价白内障手术中植入AcrySof IQ Toric散光型人工晶状体矫正角膜散光的效果及人工晶状体在囊袋内的稳定性。

方法:对21例26眼伴有角膜规则散光的白内障患者,植入AcrySof IQ Toric散光型人工晶状体,观察术前及术后裸眼视力、最佳矫正视力; 术前角膜散光、预计散光、总散光,术后角膜散光及残余散光; 以及术后人工晶状体旋转度。

结果:术后所有患者裸眼视力及最佳矫正视力均明显提高; 术后残留散光0.55±0.33D,与术前总散光2.05±0.57D相比明显下降(t=13.574,P<0.05); 与术前预留散光0.47±0.19D比较无统计学意义(t=1.149,P>0.05)。术后3mo角膜散光-1.89±0.53D,与术前角膜散光2.01±0.58D相比无差异(t=1.908,P>0.05); 所有26眼的人工晶状体旋转度均<20°,平均旋转为(3.65±2.86)度。

结论:白内障超声乳化吸除联合AcrySof IQ Toric IOL植入矫正散光手术,能够有效的减少患者的散光,术后IOL旋转稳定性良好,是治疗白内障合并散光患者的有效的手术方法。  相似文献   


7.

目的:旨在证实双陡峭轴透明角膜切口能有效降低白内障合并中低度数角膜散光患者的角膜散光和高阶像差,提高术后视觉质量。

方法:收集2020-10/2021-07在我院确诊为中低度数角膜散光的白内障患者共60例,随机分成A组(常规135°切口组,30例)和B组(双陡峭轴透明角膜切口组,30例),对比术前,术后1、3mo的裸眼视力、散光、散光矢量分解、极向散光值以及角膜中央3mm以内的二阶散光、球差、彗差、三叶草等指标。

结果:A组和B组术后1、3mo的裸眼视力(UCVA)均较术前明显提高(P<0.05); B组术后1、3mo的UCVA均优于A组,但无差异(P>0.05)。A组术后1、3mo的角膜散光较术前无明显变化(P>0.05),B组术后1、3mo的平均角膜散光分别为0.66±0.13、0.61±0.12D,较术前1.38±0.24D明显降低(P<0.05)。B组术后1、3mo CJ0/CJ45与术前均无明显变化(P>0.05); A组术后1、3mo CJ0/CJ45与术前均有明显变化(P<0.05)。B组术后1、3mo的极向散光值均较术前低(P<0.05),A组术后1、3mo的极向散光值均较术前升高(P<0.05)。A组和B组术后3mo的HOA均较术前HOA降低(P<0.05),B组术后3mo 平均HOA虽较A组的低,但无差异(P>0.05)。B组术后3mo的彗差较术前和A组低(均P<0.05)。

结论:白内障合并中低度数角膜散光患者中,双陡峭轴透明角膜切口与常规切口的术后裸眼视力和HOA无明显差异,然而双陡峭轴透明角膜切口能通过有效降低角膜散光和彗差,提高患者的术后视觉质量。  相似文献   


8.
刘云芳  杨卫华 《国际眼科杂志》2015,15(10):1811-1813
目的:探讨老年性白内障合并角膜散光行超声乳化摘除联合Toric人工晶状体植入的临床效果,比较Acrysof Toric人工晶状体植入前后的视觉质量。

方法:选择老年性白内障合并角膜散光的患者34例为研究对象,进行白内障超声乳化摘除联合Toric人工晶状体植入,观察术前和术后3mo的临床效果,包括裸眼视力(UCVA),最佳矫正视力(BCVA),全眼残余散光,人工晶状体转动度数,视远脱镜情况。

结果:所有患者Toric人工晶状体均成功植入。术前UCVA 0.15±0.06,术后UCVA上升至0.65±0.15(P<0.01); 术前BCVA 0.37±0.13,术后BCVA上升至0.85±0.19(P<0.01); 全眼散光由术前2.14±0.69D降低至0.73±0.36D(P<0.01),97%的患者人工晶状体转位<5°,平均旋转2.6°±1.3°,术后3mo视远脱镜率达95%。

结论:Toric人工晶状体能够有效矫正白内障合并的角膜散光,晶状体在囊袋内具有良好的稳定性,提高了患者的术后视觉质量。  相似文献   


9.
目的:对老年性白内障合并角膜散光患者采用超声乳化白内障摘除术联合散光型人工晶状体(intraocular lens,IOL)植入的临床疗效进行评估。

方法:采用随机数字表法将本院眼科中心收治的64例84眼老年性白内障合并散光患者分为散光型IOL组33例42眼和球面IOL组31例42眼,散光IOL组采用超声乳化白内障摘除术联合散光型人工晶状体植入术治疗,球面IOL组采用常规颞侧透明角膜切口超声乳化白内障摘除球面人工晶状体植入联合陡峭轴位上一对角膜缘松解切口治疗。观察两组手术前、术后3mo的视力分布、角膜散光度、球镜及柱镜指标(曲率、轴向、小瞳验光球镜、小瞳验光柱镜、散光轴向)的变化情况。

结果:散光型IOL组和球面IOL组在术后第3mo复查裸眼视力,与同组术前比较视力均提高(P<0.05),术后散光型IOL组和球面IOL组裸眼视力比较,散光型IOL组裸眼视力分布优于球面IOL组(Z=-2.172,P=0.030<0.05)。术后3mo散光型IOL组、球面IOL组患者的角膜散光度与同组患者术前比较减小,差异具有统计学意义(P<0.05)。散光型IOL组和球面IOL组的小瞳验光球镜、小瞳验光柱镜较术前均减小(P<0.05),散光轴向较术前变化无统计学差异(P>0.05); 术后3mo散光型IOL组的小瞳验光球镜、小瞳验光柱镜值显著低于球面IOL组(P<0.05)。

结论:老年性白内障合并散光患者采用超声乳化白内障摘除术联合散光型人工晶状体植入具有较好的临床效果。  相似文献   


10.

目的:观察并比较AT LISA tri 839MP三焦点人工晶状体及CT SPHERIS 209M单焦点人工晶状体植入术后白内障患者的视力、对比敏感度和视觉质量。

方法:行白内障超声乳化摘除联合人工晶状体植入术的患者52例52眼,其中三焦点组26例26眼,术中植入AT LISA tri 839MP三焦点人工晶状体; 单焦点组26例26眼,术中植入CT SPHERIS 209M单焦点人工晶状体。术后3mo检查患者的裸眼远距离视力(UCDVA)、裸眼中距离视力(UCIVA)、裸眼近距离视力(UCNVA)、最佳矫正远视力(BCDVA)、远视力矫正下的中距离视力(DCIVA)、远视力矫正下的近距离视力(DCNVA),明、暗环境中不同空间频率(3、6、12、18c/d)下的对比敏感度,并进行脱镜率、不良视觉症状和满意度等问卷调查。

结果:术后3mo三焦点组UCIVA、UCNVA、DCIVA和DCNVA、脱镜率及满意度均优于单焦点组(P<0.05)。在暗环境中的18c/d空间频率,单焦点组的对比敏感度优于三焦点组(P=0.041)。两组均有轻度眩光和光晕不适主诉(P=0.668)。

结论:AT LISA tri 839MP三焦点人工晶状体较CT SPHERIS 209M单焦点人工晶状体为患者提供了更好的中、近视力,脱镜率和满意度均高于单焦点人工晶状体。  相似文献   


11.
目的:对三焦点、双焦点及连续视程人工晶状体植入术后的单眼视力和动态视力(DVA)进行评估及比较。方法:前瞻性临床研究。选取2020年1月至2021年1月于重庆医科大学附属第一医院眼科行白内障超声乳化摘除联合人工晶状体植入且资料完整的白内障患者65例(81眼)。根据所选择的IOL 类型分为3组:双焦点组33眼,植入Tecnis ZMB00 IOL;三焦点组20眼,植入AT Lisatri.839MP IOL;EDOF组28眼,植入Tecnis ZXR00 IOL。术后3个月分别检测每眼的裸眼静态视力(SVA):包括裸眼远视力(UDVA)、裸眼中视力(UIVA)、裸眼近视力(UNVA)(LogMAR视力)。采用运动视标法检测裸眼DVA(检测速度分别为4、8、12、24fps):包括裸眼动态远视力(UDDVA)、裸眼动态中视力(UIDVA)、裸眼动态近视力(UNVA)(LogMAR视力),并进行评估比较。通过“手抓尺子试验”检测患者反应速度。数据采用卡方检验、方差分析、Kruskal-WallisH检验进行统计分析。结果:3组的总体UDVA、UNVA差异均无统计学意义;3组的总体UIVA差异有统计学意义(H=23.13,P<0.001),进一步两两比较发现EDOF组优于双焦点组(P<0.001);三焦点组优于双焦点组(P=0.016);EDOF 组与三焦点组差异无统计学意义。3组的总体UDDVA在4、8fps时差异均无统计学意义;而在12、24fps时总体差异均有统计学意义(H=10.96,P=0.004;H=11.52,P=0.003),进一步比较发现双焦点组优于三焦点组(H=-16.21,P=0.003;H=-17.98,P=0.004),EDOF组优于三焦点组(H=-12.67,P=0.030;H=-16.48,P=0.009),双焦点组与EDOF组差异无统计学意义。3组的总体UIDVA在8fps 时差异无统计学意义,而在4、12、24fps时差异均有统计学意义(H=8.17~11.36,P<0.05):4、12fps 时,EDOF组优于双焦点组(H=14.61,P=0.013;H=14.52,P=0.009),与三焦点组差异无统计学意义;24fps时,EDOF组优于双焦点组、三焦点组(H=15.31,P=0.008;H=-16.60,P=0.027)。3组的总体UNDVA在4、8、12、24fps时差异均有统计学意义(H=11.25~17.61,P<0.05),且EDOF组均分别优于双焦点组(H=12.71~17.87,P<0.05)和三焦点组(H=-23.04~-15.87,P<0.05),双焦点组与三焦点组差异均无统计学意义(均P>0.05)。结论:在SVA方面,三焦点IOL及EDOFIOL均可获得较好的UDVA、UIVA、UNVA,而双焦点IOL的UIVA较弱。在DVA方面,远距离、低速度时,3种IOL结果相当;但是近距离、高速度时,EDOFIOL的DVA较其余二者更佳。  相似文献   

12.
目的:比较双焦点人工晶状体(AtLisa tri 809MP)与三焦点人工晶状体(AtLisa tri 839MP)植入术后矫正老视疗效的差异。方法:纳入于我院行白内障超声乳化吸除联合人工晶状体植入术的患者共40例51眼进行分析,其中A组20例25眼植入809MP双焦点人工晶状体,B组20例26眼植入839MP三焦点人工晶状体。收集两组患者术后3mo时远中近视力数值、离焦曲线分析,并通过满意度调查问卷进行统计分析。结果:术后3mo两组裸眼远视力与最佳矫正视力均无差异(P>0.05);中距离视力(80cm)B组显著优于A组(P<0.01);近距离视力改善程度A组、B组无差异(P>0.05)。术后3mo离焦曲线结果A组在0、-3D处形成2个波峰;B组在0、-2.5D处形成2个波峰;两组患者术后均有不同程度的眩光、光晕等表现,但总体满意度较高,视近满意度较高。结论:两种类型人工晶状体均可以为患者提供兼顾远、近的全程视力,术后近距离视物脱镜率高,均可提高良好的近距离视力,三焦点人工晶状体中距离视力更好。  相似文献   

13.
目的:评价白内障超声乳化吸除联合双焦点Toric人工晶状体(IOL)植入术的散光矫正临床效果。

方法:回顾性分析。纳入2020-08/2021-09间我院白内障超声乳化吸除联合双焦点Toric IOL治疗白内障合并角膜规则散光患者46例46眼的临床资料。术后随访3mo,评价术前及术后1、3mo裸眼远视力(UDVA)、裸眼近视力(UNVA)、矫正远视力(BCDVA)、矫正近视力(BCNVA)及散光的变化。测量并计算IOL轴位旋转度,行问卷调查在不同距离使用眼镜的必要性以及总体满意度。

结果:术后1、3mo UDVA、BCDVA、UNVA、BCNVA与术前比较均有差异(均P<0.001),而术后1mo UDVA、BCDVA、UNVA、BCNVA与术后3mo比较均无差异(均P>0.0167)。术后3mo UDVA达到0.20(LogMAR)者46眼(100%),UNVA达到0.20(LogMAR)者40眼(87%)。散光矢量分析显示,术前角膜散光均值为1.88±0.70D,质心值为0.61D@177°±1.93D,术后3mo残余散光均值为0.33±0.30D,质心值为0.03D@ 34°±0.45D。术后3mo IOL轴位旋转度为3°(0°,5°)。只有5例(11%)患者要求对近距离或中距离进行一定程度的屈光矫正。83%(38例)对手术结果感到满意或非常满意。

结论:白内障术中植入双焦点Toric IOL能有效矫正术眼的角膜规则散光,提高裸眼远近视力,患者满意度高。  相似文献   


14.
Purpose:The aim of this study was to compare the visual outcomes of two monofocal intraocular lenses (IOLs), with emphasis on the defocus curve.Methods:A total of 116 consecutive eyes with cataract, undergoing phacoemulsification with IOL implantation were included in the observational case series, and divided into two groups. 71 eyes were implanted with Tecnis Eyhance and 45 with Tecnis 1 monofocal IOL. Eyes with ocular comorbidities, previous ocular surgeries and corneal astigmatism >1 Diopters (D) were excluded from the study. Complete ophthalmic evaluation including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), corrected intermediate visual acuity (CIVA), uncorrected visual acuity (UNVA), corrected near visual acuity (CNVA) was noted and defocus levels ranging from - 4.00 D to + 1.00 D were plotted postoperatively in both groups.Results:Uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA) was significantly better in Tecnis Eyhance group compared to Tecnis 1 monofocal. Both the IOLs have similar performance for distance vision but visual acuity at intermediate and near is significantly better with Tecnis Eyhance compared to Tecnis 1 piece IOL.Conclusion:Tecnis Eyhance IOL with its better defocus curve, not only provides good distance, but intermediate vision as well. With significantly better visual acuity across the range of near and intermediate vision, Tecnis Eyhance IOL can prove to be a viable and reasonable option for patients who are more dependent on intermediate vision in daily activities.  相似文献   

15.
Purpose

To compare the visual and refractive outcomes of bifocal toric and trifocal toric intraocular lenses (IOL) in patients with moderate to high myopia at 12 months after implantation.

Method

This is a prospective and comparative study. In 120 eyes with moderate to high myopia and astigmatism, bifocal toric IOLs (n?=?60 eyes) or trifocal toric IOLs (n?=?60 eyes) were implanted. Eyes with axial lengths from 24.0 to 26.5 mm were included. Postoperative examinations measured near, intermediate, and distance visual acuity (VA), along with refractive measurements, binocular defocus curves, and patient satisfaction with the National Eye Institute Visual Function Questionnaire.

Results

For uncorrected- and corrected distance intermediate VA, the trifocal group showed significantly better VA at 1, 3, 6, and 12 months than the bifocal group. Driving subscale scores from the questionnaire were significantly better in the trifocal than the bifocal group. Concerning the binocular defocus curve, uncorrected distance VA was significantly higher in the trifocal than bifocal group at test distances of -1.5 D.

Conclusions

Both trifocal and bifocal toric IOLs effectively corrected the near, intermediate, and distance vision in patients with moderate to high myopia and astigmatism. However, intermediate vision was significantly better in eyes with trifocal than bifocal toric IOLs.

  相似文献   

16.
目的:比较双眼及单眼植入Tecnis Symfony连续视程人工晶状体(IOL)术后患者主观视觉质量、阅读流畅性及术后满意度的差异.方法:对我院48例71眼行白内障超声乳化吸除联合IOL植入术的患者进行回顾性分析,根据植入IOL类型不同分为2组,其中23例46眼双眼植入Symfony IOL为双眼组,25例25眼一眼植...  相似文献   

17.
PurposeTo evaluate visual performance after bilateral implantation of an extended depth of focus (EDOF) intraocular lens (IOL).MethodsThis multicenter, prospective, observational study included 100 patients who underwent bilateral cataract surgery with a toric or non-toric EDOF IOL (Tecnis Symfony), and 96 patients completed the final assessment at 4 to 6 months. Binocular corrected distance visual acuity and uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA), spectacle independence, visual symptoms, and patient satisfaction were evaluated.ResultsMean decimal visual acuity results showed a binocular corrected distance visual acuity of 1.10 ± 0.18, UDVA of 1.04 ± 0.17, UIVA of 0.96 ± 0.16, and UNVA of 0.68 ± 0.18. Binocular UDVA and UIVA were 0.8 (decimal) or better in 98% and 94% of patients, respectively. Binocular UNVA was 0.63 (decimal) or better in 76% of patients. Overall, 76% of the patients achieved spectacle independence across all distances, and more than 85% reported no or mild dysphotoptic phenomena. On a scale of 0 to 10, the median patient satisfaction score was 9 for far, 9.5 for intermediate, and 8 for near vision.ConclusionsThe Symfony EDOF IOL provided excellent distance, intermediate visual outcome, and functional near visual acuity. The visual results were associated with prominent levels of spectacle independence and patient satisfaction.  相似文献   

18.
目的 比较多焦点散光型人工晶状体(IOL)和单焦点散光型IOL植入术后的视觉质量。方法 回顾性非随机对照研究。角膜散光大于1.0 D的白内障患者27例(32眼),其中8例(10眼)植入非球面多焦点散光型IOL(Acrysof IQ Restor toric IOL,SND1T,SND1T组),19例(22眼)植入非球面单焦点散光型IOL(Acrysof IQ toric IOL,SN6AT,SN6AT组)纳入本研究。术后1、3、6个月观察2组远近裸眼视力(UCVA)、最佳矫正视力(BCVA),残余散光,IOL旋转度,对比敏感度,调制传递函数(MTF)以及全眼波前像差等。采用独立样本t检验及重复测量方差分析对数据进行分析。结果 术后各时间点,SND1T组近UCVA均明显优于SN6AT组(t=11.683、8.252、7.384,P<0.01);术后6个月,SND1T组在有眩光低空间频率(3 c/d)的对比敏感度低于SN6AT组(t=2.086,P<0.05),其余空间频率差异无统计学意义;3 mm瞳孔下,SND1T组在低空间频率(5、10 c/d)的MTF值低于SN6AT组(t=2.050、2.078,P<0.05),其余空间频率差异无统计学意义。术后各时间点,2组间远UCVA、远近BCVA差异均无统计学意义;术后6个月,2组间术前术后角膜散光差值、IOL旋转度差异均无统计学意义;2组在无眩光所有空间频率的对比敏感度、5 mm瞳孔下各空间频率的MTF值以及3 mm和5 mm瞳孔下的全眼总像差、总高阶像差、球差、彗差的差异均无统计学意义。结论 与单焦点散光型IOL相比,多焦点散光型IOL可获得良好的全程视力,并能有效矫正散光,同时提供理想的视觉质量。  相似文献   

19.
鲁铭  朱晶  肖泽锋 《国际眼科杂志》2021,21(7):1166-1169

目的:比较Tecnis Symfony连续视程人工晶状体与Zeiss三焦点人工晶状体(At Lisa tri 839MP)植入术后患者视觉质量的差异。

方法:选取2019-01/2020-12于我院行白内障超声乳化吸除联合人工晶状体植入术的患者42例53眼,其中A组22例29眼植入Tecnis Symfony连续视程人工晶状体,B组20例24眼植入Zeiss三焦点人工晶状体。观察两组患者术后3mo时远中近视力,绘制离焦曲线,并评估生活质量,记录并发症发生情况。

结果:术后3mo,两组患者视力均明显改善,两组患者裸眼远(5m)、中(80cm)距离视力及最佳矫正远距离视力(5m)无差异(均P>0.05),但B组患者裸眼中(60cm)、近(40cm)距离视力优于A组(均P<0.05)。术后3mo绘制离焦曲线示A组在+1.0~-2.0D段跨度平稳形成平台期; B组在0、-2.5D处形成两个波峰; 0D处两组远视力无显著差异(P>0.05),-2.5、-3.5D处B组近视力显著优于A组(均P<0.01)。两组患者术后脱镜率均在90%以上,均出现不同程度眩光、光晕等光学现象,但生活质量总体满意度较高,A组阅读速度明显高于B组,且夜间视物满意度较高(均P<0.05)。

结论:两种类型人工晶状体植入术后脱镜率均在90%以上,可为患者提供兼顾远、中、近的全程视力,Symfony连续视程人工晶状体植入术后流畅阅读及夜间视物满意度较高; Zeiss三焦点人工晶状体植入术后近距离视力更好,更适合近距离工作者。  相似文献   


20.
Sun Y  Zheng DY  Ling SQ  Song TT  Liu YZ 《眼科学报》2012,27(1):5-12
 Purpose: To evaluate visual outcomes after implantation of an aspheric multifocal/ intraocular lens (MIOL) or an aspheric monofocal intraocular lens (IOL). Methods: This was a prospective nonrandomized study. During 3-months of post-operative follow-up, the following outcomes for SN6AD1 MIOL (multifocal group) and SN60WF IOL (monofocal group) were compared: uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, Chinese character near visual acuity, uncorrected intermediate visual acuity (UIVA) under high (100% contrast) and low contrast (10% contrast), UIVA for different IOL powers, and a quality-of-life questionnaire. Results: UNVA, DCNVA, and UIVA under high contrast in the multifocal group were significantly better than those in the monofocal group (P<0.05). UDVA, CDVA and UIVA under low contrast did not differ between groups at 63 cm and 100 cm (P>0.05). In most of the cases, Chinese character near visual acuity was significantly better in the multifocal group (P<0.05). UNVA and UIVA at 63cm were improved 3 months post-operatively. Better UIVA was found in emmetropic and mild myopic eyes as compared to hyperopic ones. The patients in the multifocal group had a higher degree of satisfaction and performed better on near and intermediate tasks, although with greater complaints of visual disturbance.    Conclusion: The SN6AD1 MIOL provides significantly better UNVA, DCNVA and UIVA under high contrast conditions, and better Chinese character near visual acuity. Patients receiving the SN6AD1 MIOL reported a better quality of vision in spite of more serious visual disturbances. Better UIVA was observed in emmetropic and mildly myopic eyes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号