首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 469 毫秒
1.
Abstract The amount of volatile organic compounds (VOCs) in indoor air, usually called TVOC (total volatile organic compounds), has been measured using different definitions and techniques which yield different results. This report recommends a definition of TVOC referring to a specified range of VOCs and it proposes a method for the measurement of this TVOC entity. Within the specified range, the measured concentrations of identified VOCs (including 64 target compounds) are summed up, concentrations of non-identified compounds in toluene equivalents are added and, together with the identified VOCs, they give the TVOC value. The report reviews the TVOC concept with respect to its usefulness for exposure assessment and control and for the prediction of health or comfort effects. Although the report concludes that at present it is not possible to use TVOC as an effect predictor, it affirms the usefulness of TVOC for characterizing indoor pollution and for improving source control as required from the points of view of health, comfort, energy efficiency and sustainability.  相似文献   

2.
A review is presented of investigations of volatile organic compound (VOC) concentrations in indoor air of buildings of different classifications (dwellings, offices, schools, hospitals) and categories (established, new and complaint buildings). Measured concentrations obtained from the published literature and from research in progress overseas were pooled so that VOC concentration profiles could be derived for each building classification/category. Mean concentrations of individual compounds in established buildings were found to be generally below 50 μg/m3, with most below 5 μg/m3. Concentrations in new buildings were much greater, often by an order of magnitude or more, and appeared to arise from construction materials and building contents. The nature of these sources and approaches to reduce indoor air concentrations by limiting source VOC emissions is discussed. Total VOC (TVOC) concentrations were substantially higher than concentrations of any individual VOCs in all situations, reflecting the large number of compounds present, but interpretation of such measurements was limited by the lack of a common definition for TVOC relevant to occupant exposure.  相似文献   

3.
Scientific literature on the effects of ventilation on health, comfort, and productivity in non-industrial indoor environments (offices, schools, homes, etc.) has been reviewed by a multidisciplinary group of European scientists, called EUROVEN, with expertise in medicine, epidemiology, toxicology, and engineering. The group reviewed 105 papers published in peer-reviewed scientific journals and judged 30 as conclusive, providing sufficient information on ventilation, health effects, data processing, and reporting, 14 as providing relevant background information on the issue, 43 as relevant but non-informative or inconclusive, and 18 as irrelevant for the issue discussed. Based on the data in papers judged conclusive, the group agreed that ventilation is strongly associated with comfort (perceived air quality) and health [Sick Building Syndrome (SBS) symptoms, inflammation, infections, asthma, allergy, short-term sick leave], and that an association between ventilation and productivity (performance of office work) is indicated. The group also concluded that increasing outdoor air supply rates in non-industrial environments improves perceived air quality; that outdoor air supply rates below 25 l/s per person increase the risk of SBS symptoms, increase short-term sick leave, and decrease productivity among occupants of office buildings; and that ventilation rates above 0.5 air changes per hour (h-1) in homes reduce infestation of house dust mites in Nordic countries. The group concluded additionally that the literature indicates that in buildings with air-conditioning systems there may be an increased risk of SBS symptoms compared with naturally or mechanically ventilated buildings, and that improper maintenance, design, and functioning of air-conditioning systems contributes to increased prevalence of SBS symptoms.  相似文献   

4.
Brown SK 《Indoor air》2002,12(1):55-63
Volatile organic compounds (VOCs) within new and established buildings have been determined and factors significant to their presence have been identified. In established dwellings, total volatile organic compound (TVOC) concentrations were low, but were approximately four times higher than in outdoor air, showing a dominant effect of indoor sources. The presence of attached garages, site contamination and 'faulty' wool carpet were associated with higher indoor pollution. In three dwellings, unidentified sources of benzene were indicated. Much higher VOC concentrations were observed in new or renovated buildings, persisting above "baseline" levels for several weeks, concentration decay rate correlating with VOC molecular volume, indicating emissions were limited by material diffusion processes. VOC and formaldehyde emission decays in a new dwelling occurred by a double-exponential source model. This shows that persistent low levels of volatile organic pollutants in established dwellings can occur due to long-term emissions from building materials.  相似文献   

5.
Current design models for ultraviolet photocatalytic oxidation (UV-PCO) devices often assume that the air contains only one volatile organic compound (VOC) species or all the VOCs in the air can be treated on a non-interacting basis. However, trace-level multiple VOCs co-exist in most indoor environments. This paper assesses the significance of interference effects among different VOCs for indoor applications by full-scale “pull-down” experiments assisted with model simulations. Multiple versus single VOC tests were performed on selected groups of compounds under low concentration levels. Removal efficiency for each compound was calculated. It was found that the interference effect among test VOCs were generally small in the 2-VOC and 3-VOC mixture tests performed on toluene, ethylbenzene, octane, decane and dodecane with initial concentration of approximate 1 mg/m3 for each compound. However, in the 16 VOC mixture test, the interference effect among different VOCs became quite obvious, and compounds with lower removal efficiency in the single compound test appeared to also have relatively lower efficiency and more obvious delay period in the initial reaction. The L–H model appears to be able to account for this effect if reaction rate constants can be accurately estimated. Results, although limited, indicate that interference between multiple VOCs may not be neglected for the PCO reactor for indoor applications where the number of VOCs species is large and the TVOC concentration is high.  相似文献   

6.
论述了室内空气质量的重要性以及室内挥发性有机物(VOC)对健康的危害,介绍了评价VOC污染的量化指标TVOC和减少室内VOC污染的技术和措施。  相似文献   

7.
Hotel housekeepers represent a large, low-income, predominantly minority, and high-risk workforce. Little is known about their exposure to chemicals, including volatile organic compounds (VOCs). This study evaluates VOC exposures of housekeepers, sources and factors affecting VOC levels, and provides preliminary estimates of VOC-related health risks. We utilized indoor and personal sampling at two hotels, assessed ventilation, and characterized the VOC composition of cleaning agents. Personal sampling of hotel staff showed a total target VOC concentration of 57 ± 36 µg/m3 (mean ± SD), about twice that of indoor samples. VOCs of greatest health significance included chloroform and formaldehyde. Several workers had exposure to alkanes that could cause non-cancer effects. VOC levels were negatively correlated with estimated air change rates. The composition and concentrations of the tested products and air samples helped identify possible emission sources, which included building sources (for formaldehyde), disinfection by-products in the laundry room, and cleaning products. VOC levels and the derived health risks in this study were at the lower range found in the US buildings. The excess lifetime cancer risk (average of 4.1 × 10−5) still indicates a need to lower exposure by reducing or removing toxic constituents, especially formaldehyde, or by increasing ventilation rates.  相似文献   

8.
Concentrations of total volatile organic compounds (TVOC) exceeding 1 mg/m3 have been implicated in the Sick Building Syndrome. Very few measurements of TVOC have been made in homes and buildings in the United States. However, stored gas chromatography-mass spectrometry (GC-MS) data on 12-hour average values of individual VOCs from 750 homes and 10 buildings were available from EPA's Total Exposure Assessment Methodology (TEAM) Studies (1981-88). An initial study to determine the feasibility of obtaining a TVOC value from stored GC/MS data showed that TVOC estimates could be obtained with adequate precision. Therefore TVOC values were calculated for about 2700 personal, indoor, and outdoor air samples collected in the TEAM Studies. More than half of the personal and indoor air samples had TVOC levels exceeding 1 mg/m3, compared to only about 10% of the outdoor air samples. However, these calculated values may not be directly comparable with values determined using different sampling and analytical techniques. Nonetheless, since all samples were collected on Tenax cartridges, which (like all sorbents) adsorb only a portion of the organic chemicals in the air, these values are likely to be underestimates of the total volatile organic loading.  相似文献   

9.
Numerous methods attempt to measure the combined concentrations of volatile organic compounds (VOCs) in indoor air as total VOCs (TVOC). This paper reviews TVOC methods recently presented in the literature and at an international conference on indoor air quality, for the purpose of identifying common practices and of assessing the impacts that choices of sample collection media and analytical methods and instrumentation can have on TVOC results. The paper also presents the results of laboratory and field comparisons of three TVOC methods. These are a flame-ionization-detector (FID) method, a gas chromatography/mass spectrometry (GC/MS) method, and a method employing a photoacoustic infrared (IR) gas monitor. The laboratory experiments were conducted with eight different mixtures of VOCs. The FID method demonstrated an average accuracy of 93 ± 18 percent when the measured values were calculated as concentrations of carbon. The FID and GC/MS methods demonstrated average accuracies of 77±37 and 75±22 percent, respectively, when the measured hydrocarbon-equivalent values were compared to the expected mass concentrations of the mixtures. The higher uncertainty for the FID was largely due to the low mass response of 27 percent for chlorinated compounds. The response of the IR gas monitor varied between 6 and 560 percent for different classes of compounds. Air samples from ten buildings were analyzed by both the FID and GC/MS methods. The results were highly correlated and similar, with the GC/MS values approximately 20 percent higher on average.  相似文献   

10.
Volatile organic compounds (VOCs) were sampled in buildings where people with non-specific building-related symptoms perceive health problems and in buildings where they do not. In total, nine persons and 34 buildings were included in the study. The obtained VOC data was evaluated using multivariate methods, to investigate possible systematic differences in air quality of 'problem' and 'non-problem' buildings. All individual compounds were included as variables in a multivariate partial least squares (PLS) data analysis. 'Problem' and 'non-problem' buildings separated into two distinct groups, showing that air samples of the two groups of building were chemically different. PRACTICAL IMPLICATIONS: The study showed that there was an identifiable systematic difference in the collected VOC data between buildings causing and not causing problems for people with non-specific building-related symptoms (also called sick building syndrome, SBS). This is an important indication that even such volatile organic compounds that can be sampled by commonly used adsorbents are of importance for the presence of such symptoms. By coordination of procedures for sampling and analysis of VOCs in buildings between laboratories, to get large datasets and more general models, the method can become a useful diagnostic measure in evaluating indoor air and to identify chemical compounds and sources that contribute to SBS problems.  相似文献   

11.
A review of the emission of VOCs from polymeric materials used in buildings   总被引:6,自引:0,他引:6  
Building and furnishing materials and consumers products are important sources of formaldehyde and other volatile organic compounds (VOCs) in the indoor environment. The emission from materials is usually continuous and may last for many years in a building. The available evidence indicates that VOCs can cause adverse health effects to the building occupants and may contribute to symptoms of ‘Sick Building Syndrome’.

Control of VOC emission should increasingly become an important consideration for the design and manufacture of polymeric materials used in buildings. The EC Construction Products Directive ‘Essential Requirements’ set a framework for limiting the use of materials that could pose a health risk to building occupants. Furthermore, the on-going development of voluntary labelling schemes and data bases of material emissions that could be used by building designers, should further strengthen the demand for ‘low VOC emitting’ products.

This paper reviews available information about the emission of VOCs from polymeric building materials, the level of emissions in the indoor environment and the requirements for testing of the materials.  相似文献   


12.
Exposure to elevated levels of certain volatile organic compounds (VOCs) in households has been linked to deleterious health effects. This study presents the first large-scale investigation of VOC levels in 169 energy-efficient dwellings in Switzerland. Through a combination of physical measurements and questionnaire surveys, we investigated the influence of diverse building characteristics on indoor VOCs. Among 74 detected compounds, carbonyls, alkanes, and alkenes were the most abundant. Median concentration levels of formaldehyde (14 μg/m3), TVOC (212 μg/m3), benzene (<0.1 μg/m3), and toluene (22 μg/m3) were below the upper exposure limits. Nonetheless, 90% and 50% of dwellings exceeded the chronic exposure limits for formaldehyde (9 μg/m3) and TVOC (200 μg/m3), respectively. There was a strong positive correlation among VOCs that likely originated from common sources. Dwellings built between 1950s and 1990s, and especially, those with attached garages had higher TVOC concentrations. Interior thermal retrofit of dwellings and absence of mechanical ventilation system were associated with elevated levels of formaldehyde, aromatics, and alkanes. Overall, energy-renovated homes had higher levels of certain VOCs compared with newly built homes. The results suggest that energy efficiency measures in dwellings should be accompanied by actions to mitigate VOC exposures as to avoid adverse health outcomes.  相似文献   

13.
The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and VOCs in 37 newly built or recently retrofitted office buildings across 8 European countries in summer and winter and (b) the collection of information on building and offices’ characteristics using checklists. Linear mixed models for repeated measurements were applied to identify the main factors affecting the measured concentrations of selected indoor air pollutants (IAPs). Several associations between aldehydes and VOCs concentrations and buildings’ structural characteristic or occupants’ activity patterns were identified. The aldehyde and VOC determinants in office buildings include building and furnishing materials, indoor climate characteristics (room temperature and relative humidity), the use of consumer products (eg, cleaning and personal care products, office equipment), as well as the presence of outdoor sources in the proximity of the buildings (ie, vehicular traffic). Results also showed that determinants of indoor air concentrations varied considerably among different type of pollutants.  相似文献   

14.
Ultraviolet photocatalytic oxidation (UVPCO) systems for removal of volatile organic compounds (VOCs) from air are being considered for use in office buildings. Here, we report an experimental evaluation of a UVPCO device with tungsten oxide modified titanium dioxide (TiO2) as the photocatalyst. The device was challenged with complex VOC mixtures. One mixture contained 27 VOCs characteristic of office buildings and another comprised 10 VOCs emitted by cleaning products, in both cases at realistic concentrations (low ppb range). VOC conversion efficiencies varied widely, usually exceeded 20%, and were as high as approximately 80% at about 0.03 s residence time. Conversion efficiency generally diminished with increased airflow rate, and followed the order: alcohols and glycol ethers > aldehydes, ketones, and terpene hydrocarbons > aromatic and alkane hydrocarbons > halogenated aliphatic hydrocarbons. Conversion efficiencies correlated with the Henry's law constant more closely than with other physicochemical parameters. An empirical model based on the Henry's law constant and the gas-phase reaction rate with hydroxyl radical provided reasonable estimates of pseudo-first order photocatalytic reaction rates. Formaldehyde, acetaldehyde, acetone, formic acid and acetic acid were produced by the device due to incomplete mineralization of common VOCs. Formaldehyde outlet/inlet concentration ratios were in the range 1.9-7.2. PRACTICAL IMPLICATIONS: Implementation of air cleaning technologies for both VOCs and particles in office buildings may improve indoor air quality, or enable indoor air quality levels to be maintained with reduced outdoor air supply and concomitant energy savings. One promising air cleaning technology is ultraviolet photocatalytic oxidation (UVPCO) air cleaning. For the prototype device evaluated here with realistic mixtures of VOCs, conversion efficiencies typically exceeded the minimum required to counteract predicted VOC concentration increases from a 50% reduction in ventilation. However, the device resulted in the net generation of formaldehyde and acetaldehyde from the partial oxidation of ubiquitous VOCs. Further development of the technology is needed to eliminate these hazardous air pollutants before such a UVPCO device can be deployed in buildings.  相似文献   

15.
Abstract Occupants of office buildings are exposed to low concentrations of complex mixtures of volatile organic compounds (VOCs) that encompass a number of chemical classes and a broad range of irritancies. “Sick building syndrome” (SBS) is suspected to be related to these exposures. Using data from 22 office areas in 12 California buildings, seven VOC exposure metrics were developed and their ability to predict self-reported SBS irritant symptoms of office workers was tested. The VOC metrics were each evaluated in a multivariate logistic regression analysis model adjusted for other risk factors or confounders. Total VOCs and most of the other metrics were not statistically significant predictors of symptoms in crude or adjusted analyses. Two metrics were developed using principal components (PC) analysis on subsets of the 39 VOCs. The Irritancy/PC metric was the most statistically significant predictor of adjusted irritant symptoms. The irritant potencies of individual compounds, highly correlated nature of indoor VOC mixtures, and probable presence of potent, but unmeasured, VOCs were variously factored into this metric. These results, which for the first time show a link between low level VOC exposures from specific types of indoor sources to SBS symptoms, require confirmation using data sets from other buildings.  相似文献   

16.
Seasonal cycle of VOCs in apartments   总被引:1,自引:0,他引:1  
To assess the adverse health effects of volatile organic compounds (VOCs), epidemiological studies combine the health outcome of individuals with their concomitant VOC exposure. While the latter is representative of the studied period, health effects might also be the result of long-term exposure or emerge in consequence of a peak pollution throughout the year. To address these problems, additional information about the spatiotemporal distribution of VOCs is necessary. The present paper aims at elucidating the spatial and temporal variation of VOC concentrations in Leipzig, Germany. The analysis is based on 1499 indoor and 222 outdoor measurements taken in the period between 1994 and 2001. All data were collected in the frame of epidemiological studies (Diez et al., 1999; Fritz et al., 1998; Schulz et al., 1999). The analysis comprised concentrations of 30 VOCs belonging to the groups of alkanes, cycloalkanes, aromatics, volatile halogenated hydrocarbons, and terpenes. We found that the VOC load in indoor air is, on average, 10 times higher than outdoors. For the studied period there was a clear downward tendency for all VOCs in apartments in Leipzig, except for terpenes which show an upward trend in the period 1996-99. In indoor air we observe an annual cycle for the total VOC concentration as well as the sum concentrations of the above called groups. Highest concentrations occur during the winter months, approximately three times higher than the summer burden. We summarize this finding in a seasonal model, which is fitted to our measurements. Based on the model we develop a procedure for seasonal adjustment, which enables to roughly estimate the annual peak concentration utilizing one monthly observation.  相似文献   

17.
Lars Mlhave 《Indoor air》1991,1(4):357-376
This publication summarizes field investigations and controlled experiments on the relation between low levels of indoor air pollution with volatile organic compounds (VOC) and human health and comfort. The Henle-Kock criteria from epidemiology are revised for the dose-response relation between VOC's and health as comfort effects and existing evidence for each criterion are discussed. A biological model for human responses is suggested, based on three mechanisms: sensory perception of the environment, weak inflammatory reactions, and environmental stress reactions. Further, the TVOC-indicator concept for exposure is discussed. The conclusion is that no experimental or field data contradict the proposed causality. On the contrary, evidence supports the suggested causality. The biological model, however, is not yet based on acceptable measures of the variables for exposures, co-variables or health effects. A tentative guideline for VOC's in non-industrial indoor environments is suggested. The no-effect level seems to be about 0.2 mg/m3. A multi-factorial exposure range may exist between 0.2 and 3 mg/m3. Above 3 mg/m3 discomfort is expected.  相似文献   

18.
The market for water-based paints (WBP) is growing, and these paints are favoured due to their low emission of volatile organic compounds (VOC). Because of the risk for microbial growth, biocides are usually added to WBP. Our study aimed to measure exposure to VOCs potentially of microbial origin (MVOC), during indoor application of typical Scandinavian WBP. Low concentrations of three MVOCs, 3-methyl-furan, 1-octen-3-ol, and 2-octen-1-ol, were detected during 5 out of 20 painting operations (25%). Mean exposures to MVOC and TVOC were 0.15 and 5000 μg/m3, respectively. No relation between MVOC and TVOC was observed. The highest exposure to MVOC was measured from an ecological paint, claimed to be low in VOCs and chemical additives. The results suggest that microbial growth in WBP may occur, and that measurements of MVOCs could be used as a means of quality control for WBP. The use of biocides in paint should be guided by the principle of a balance between the risk of contact allergies or other possible health hazards from the biocides, and the risk of microbial growth. If microbial growth occurs in paint, it may cause both unpleasant odor and potential health hazards for house painters and dwellers.  相似文献   

19.
Allergic asthma has increased worldwide in the industrialized countries. This review evaluates whether the major groups of indoor chemical exposures possess allergy-promoting (adjuvant) effects; formaldehyde was excluded, because of the size of the literature. Volatile organic compounds (VOCs) are used as an example of gases and vapors. The precipitation of asthmatic symptoms by VOC exposures is probably because of VOC levels considerably above typical indoor levels, or VOCs may be a surrogate for exposure to allergens, combustion products or dampness. Indoor particles possessed adjuvant effects in animal studies and allergy-promoting effects in humans. Quaternary ammonium compounds may possess adjuvant effects in animal studies and promoted sensitization in humans in occupational settings. The use of cleaning agents, anionic and non-ionic surfactants are not considered to possess an important adjuvant effect in the general population. Regarding phthalate exposures, results from animal and epidemiological studies were found to be discordant. There is little evidence that the indoor chemicals evaluated possess important adjuvant effects. If buildings are kept clean, dry and free of combustion products, the important question may be would it be profitable to look for lifestyle factors and non-chemical indoor exposures in order to abate airway allergy? PRACTICAL IMPLICATIONS: Indoor chemicals (pollutants) have been accused to promote development of airway allergy by adjuvant effects. In this review, we evaluated the scientific literature and found little support for the supposition that indoor chemicals possess important adjuvant effects. This rises the question: would it be profitable for abatement of airway allergy to look for non-chemical indoor exposures, including lifestyle factors, and exposures to allergens, microorganisms, including vira, and their interactions?  相似文献   

20.
Kim S  Kim JA  An JY  Kim HJ  Kim SD  Park JC 《Indoor air》2007,17(5):404-415
Polyvinyl acetate (PVAc) was added as a replacement for melamine-formaldehyde (MF) resin in the formaldehyde-based resin system to reduce formaldehyde and volatile organic compound (VOC) emissions from the adhesives used between plywoods and fancy veneers. A variety of techniques, including 20-l chamber, field and laboratory emission cell (FLEC), VOC analyzer and standard formaldehyde emission test (desiccator method), were used to determine the formaldehyde and VOC emissions from engineered flooring bonded with five different MF resin and PVAc blends at MF/PVAc ratios of 100:0, 70:30, 50:50, 30:70 and 0:100. Although urea-formaldehyde (UF) resin had the highest formaldehyde emission, the emission as determined by desiccator method was reduced by exchanging with MF resin. Furthermore, the formaldehyde emission level was decreased with increasing addition of PVAc as the replacement for MF resin. UF resin in the case of beech was over 5.0 mg/l, which exceeded E2 (1.5-5.0 mg/l) grade. However, MF30:PVAc70 was 相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号