首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Retrofitting concrete structures with fiber reinforced polymer (FRP) has today grown to be a widely used method throughout most parts of the world. The main reason for this is that it is possible to obtain a good strengthening effect with a relatively small work effort. It is also possible to carry out strengthening work without changing the appearance or dimensions of the structure. Nevertheless, when strengthening a structure with external FRP, it is often not possible to make full use of the FRP. The reason for this depends mainly on the fact that a strain distribution exists over the section due to dead load or other loads that cannot be removed during strengthening. This implies that steel yielding in the reinforcement may already be occurring in the service limit state or that compressive failure in the concrete is occurring. By prestressing, a higher utilization of the FRP material is made possible. It is extremely important to ensure that, if external prestressing is used, the force is properly transferred to the structure. Most of the research conducted with prestressing carbon fiber reinforced polymer (CFRP) for strengthening has been on surface bonded laminates. However, this paper presents research on prestressed CFRP quadratic rods bonded in sawed grooves in the concrete cover. This method has proven to be an advantageous means of bonding CFRP to concrete, and in comparison to surface bonded laminates, the shear and normal stress between the CFRP and the concrete are more efficiently transferred to the structure. In the presented test, no mechanical device has been used to maintain the prestress during testing, which means that the adhesive must transfer all shear stresses to the concrete. Fifteen beams with a length of 4?m have been tested. The tests show that the prestressed beams exhibited a higher first-crack load as well as a higher steel-yielding load as compared to nonprestressed strengthened beams. The ultimate load at failure was also higher, as compared to nonprestressed beams, but in relation not as large as for the cracking and yielding. In addition, the beams strengthened with prestressed FRP had a smaller midpoint deflection. All strengthened beams failed due to fiber rupture of the FRP.  相似文献   

2.
A technique for strengthening damaged concrete beams using prestressed carbon fiber reinforced polymer (CFRP) sheets was developed at Queen’s University and the Royal Military College of Canada. As part of this study, an anchorage system was developed to directly prestress the CFRP sheets by jacking and reacting against the strengthened concrete beam itself. The feasibility and effectiveness of using bonded prestressed CFRP sheets to strengthen precracked concrete beams at both room (+22°C,+72°F) and low (?28°C,?20°F) temperatures have been investigated experimentally. Materials and prestress changes due to temperature variations that would affect and cause changes in flexural behavior were studied. The strengthened beams showed significant increases in flexural stiffness and ultimate capacity as compared to the control-unstrengthened beams. The flexural behavior of the strengthened beams was not adversely affected by short-term exposure to reduced temperature (?28°C,?20°F). In addition to the experimental investigation, analytical models were developed to predict the overall flexural behavior of the strengthened beams during prestressing of the CFRP sheets and under external loading at both room and low temperatures. The model accurately predicted the flexural beam behavior. Improved serviceability behavior and higher strength were predicted for beams strengthened with the bonded prestressed CFRP sheets.  相似文献   

3.
Strengthening concrete girders with fiber-reinforced polymers (FRP) is becoming an increasingly common practice as more research investigations are favorably qualifying the technique. However, important behavioral aspects, such as fatigue in prestressed concrete beams, are yet to be adequately evaluated. An experimental program was conducted to test five pretensioned, prestressed concrete T beams designed for specific prestressing strand stress ranges under live-load conditions. The experimental testing consisted of precracking the beams, strengthening them with carbon FRP, and mechanically loading them to study the effect of increasing the live load on strand fatigue. The beams were either loaded monotonically to ultimate capacity or cyclically fatigued and then loaded monotonically to failure. All the beams were monotonically loaded past their cracking moment at midspan prior to strengthening, to simulate girders in the field. Beam 1 was tested as a control specimen under static loading up to failure. Beams 2 and 3 were strengthened with carbon FRP to have a design stress range of 124 MPa (18 ksi) under service load condition. Beams 4 and 5 were strengthened to have a higher stress range of 248 MPa (36 ksi). For all the strengthened beams, the failure mode observed was FRP rupture. The results favorably qualify the application of FRP strengthening to increase the live load of concrete beams prestressed with straight strands.  相似文献   

4.
One promising means of increasing the capacity of existing shear-deficient beams is to strengthen the structure using external prestressed carbon fiber reinforced polymer (CFRP) straps. In this system, layers of CFRP tape are wrapped around a beam to form a strap that acts like a discrete unbonded vertical prestressing tendon. Experiments were undertaken to investigate the influence of the strap spacing, the strap stiffness, the initial strap prestress level and/or any preexisting damage on the strengthened behavior, and mode of failure. An unstrengthened control beam was tested and failed in shear. In contrast, all of the strengthened beams showed a significant increase in their ultimate load capacity with several of the strengthened beams failing in flexure. A number of different failure modes were noted and initial guidelines on the design parameters that influence the propensity for a particular failure mode were developed.  相似文献   

5.
This research studies the interaction of concrete, steel stirrups, and external fiber reinforced polymer (FRP) sheets in carrying shear loads in reinforced concrete beams. A total of eight tests were conducted on four laboratory-controlled concrete T-beams. The beams were subjected to a four-point loading. Each end of each beam was tested separately. Three types of FRP, uniaxial glass fiber, uniaxial carbon fiber, and triaxial glass fiber, were applied externally to strengthen the web of the T-beams, while some ends were left without FRP. The test results show that FRP reinforcement increases the maximum shear strengths between 15.4 and 42.2% over beams with no FRP. The magnitude of the increased shear capacity is dependent not only on the type of FRP but also on the amount of internal shear reinforcement. The triaxial glass fiber reinforced beam exhibited more ductile failure than the other FRP reinforced beams. This paper also presents a test model that is based on a rational mechanism and can predict the experimental results with excellent accuracy.  相似文献   

6.
The behavior of fiber reinforced polymer (FRP) strengthened reinforced concrete beams subjected to torsional loads has not been well understood compared to other loads. Interaction of different components of concrete, steel, and FRP in addition to the complex compatibility issues associated with torsional deformations have made it difficult to provide an accurate analytical solution. In this paper an analytical method is introduced for evaluation of the torsional capacity of FRP strengthened RC beams. In this method, the interaction of different components is allowed by fulfilling equilibrium and compatibility conditions throughout the loading regime while the ultimate torque of the beam is calculated similarly to the well-known compression field theory. It is shown that the method is capable of predicting the ultimate torque of FRP-strengthened RC beams reasonably accurately.  相似文献   

7.
Many prestressed concrete bridges are in need of upgrades to increase their posted capacities. The use of carbon fiber-reinforced polymer (CFRP) materials is gaining credibility as a strengthening option for reinforced concrete, yet few studies have been undertaken to determine their effectiveness for strengthening prestressed concrete. The effect of the CFRP strengthening on the induced fatigue stress ratio in the prestressing strand during service loading conditions is not well defined. This paper explores the fatigue behavior of prestressed concrete bridge girders strengthened with CFRP through examining the behavior of seven decommissioned 9.14?m (30?ft) girders strengthened with various CFRP systems including near-surface-mounted bars and strips, and externally bonded strips and sheets. Various levels of strengthening, prestressing configurations, and fatigue loading range are examined. The experimental results are used to provide recommendations on the effectiveness of each strengthening configuration. Test results show that CFRP strengthening can reduce crack widths, crack spacing, and the induced stress ratio in the prestressing strands under service loading conditions. It is recommended to keep the prestressing strand stress ratio under the increased service loading below the value of 5% for straight prestressing strands, and 3% for harped prestressing strands. A design example is presented to illustrate the proposed design guidelines in determining the level of CFRP strengthening. The design considers the behavior of the strengthened girder at various service and ultimate limit states.  相似文献   

8.
This paper investigates the flexure of prestressed concrete beams strengthened with prestressed carbon fiber-reinforced polymer (CFRP) sheets, focusing on ductility and cracking behavior. Structural ductility of a beam strengthened with CFRP sheets is critical, considering the abrupt and brittle failure of CFRP sheets themselves. Cracking may also affect serviceability of a strengthened beam, and may be especially important for durability. Midscale prestressed concrete beams (L = 3.6?m) are constructed and a significant loss of prestress is simulated by reducing the reinforcement ratio to observe the strengthening effects. A nonlinear iterative analytical model, including tension of concrete, is developed and a nonlinear finite-element analysis is conducted to predict the flexural behavior of tested beams. The prestressed CFRP sheets result in less localized damage in the strengthened beam and the level of the prestress in the sheets significantly contributes to the ductility and cracking behavior of the strengthened beams. Consequently, the recommended level of prestress to the CFRP sheets is 20% of the ultimate design strain with adequate anchorages.  相似文献   

9.
Bond tests were conducted on concrete beams strengthened with near-surface-mounted (NSM) nonprestressed and prestressed carbon fiber-reinforced polymer (CFRP) rods under static loading. In the NSM technique, the CFRP rods are placed inside precut grooves and bonded to the concrete with epoxy adhesive. Six concrete beams were tested. The test variables included presence of internal tension steel reinforcement (unreinforced and reinforced), use of NSM CFRP strengthening (nonprestressed and prestressed), and type of CFRP rod (spirally wound and sand blasted). The beams were tested statically in four-point bending. Based on the test results, the transfer length for the prestressed CFRP rod in epoxied groove was 150 and 210 mm for the sand blasted and spirally wound rods, respectively. The main failure mode was debonding between the CFRP rod and the epoxy that starts at sections close to the midspan then, as the load increases, it propagates toward the supports. At failure, the beams strengthened with a given rod type showed the same CFRP strain at sections close to the support (29% of ultimate strain for spirally wound bars and 39% of ultimate strain for sand blasted bars). A cracked section analysis was carried out and compared well with the measured results.  相似文献   

10.
The paper is principally aimed at analyzing the role of externally applied fiber reinforced plastic (FRP) sheets in the shear ultimate behavior of reinforced concrete elements. A theoretical model for predicting the shear resisting contribution of FRP sheets is illustrated. The proposal is based on a complete equilibrium/compatibility approach for reinforced concrete beams failing in shear and considers the possible interactions between the composite contribution and the resisting mechanisms of an ordinary reinforced concrete beam. The proposal is discussed and tested by means of an experimental investigation carried out on beams reinforced by glass FRP composite sheets with a shear span to depth ratio equal to 3. Further comparisons are then performed that consider the predictions of other existing approaches reported in the literature.  相似文献   

11.
This paper presents a study on the flexural behavior of two-way reinforced concrete slabs externally strengthened with prestressed or nonprestressed carbon fiber-reinforced polymer (CFRP) sheets. Four large-scale flat plate slabs (3,000?mm×3,000?mm×90?mm) are tested and a nonlinear three-dimensional finite-element analysis is conducted to predict the flexural behaviors of the tested slabs, including the load-deflection response, strain distribution, crack propagation, and crack mouth opening displacement. An increase in the load-carrying capacity of 25 and 72% is achieved for the slabs strengthened with nonprestressed and prestressed CFRP sheets, respectively, in comparison to the unstrengthened slab. A reduction of the deflections up to 32% in service is noted for the strengthened slabs. The unstrengthened slab shows very ductile behavior, whereas, progressive failure is observed for the strengthened slabs, exhibiting pseudoductility in postpeak behavior. Stress redistribution between the internal and external reinforcement is significant in the slab strengthened with prestressed CFRP sheets.  相似文献   

12.
Rehabilitation of existing structures with carbon fiber reinforced polymers (CFRP) has been growing in popularity because they offer resistance to corrosion and a high stiffness-to-weight ratio. This paper presents the flexural strengthening of seven reinforced concrete (RC) beams with two FRP systems. Two beams were maintained as unstrengthened control samples. Three of the RC beams were strengthened with CFRP fabrics, whereas the remaining two were strengthened using FRP precured laminates. Glass fiber anchor spikes were applied in one of the CFRP fabric strengthened beams. One of the FRP precured laminate strengthened beams was bonded with epoxy adhesive and the other one was attached by using mechanical fasteners. Five of the beams were tested under fatigue loading for two million cycles. All of the beams survived fatigue testing. The results showed that use of anchor spikes in fabric strengthening increase ultimate strength, and mechanical fasteners can be an alternative to epoxy bonded precured laminate systems.  相似文献   

13.
This paper presents the flexural behavior of reinforced concrete beams strengthened with prestressed carbon fiber-reinforced polymer (CFRP) sheets using nonmetallic anchor systems. The developed nonmetallic anchor systems replace the permanent steel anchorage. Nine doubly reinforced concrete beams are tested with various types of nonmetallic anchor systems such as nonanchored U-wraps, mechanically anchored U-wraps, and CFRP sheet-anchored U-wraps. The flexural behavior of the tested beams, including detailed failure modes of each nonmetallic anchor system, is investigated. The study shows that the developed nonmetallic anchors are more effective in resisting peeling-off cracks compared to the permanent steel anchors and the beams strengthened with the nonmetallic anchors provide comparable load-carrying capacity with respect to the steel anchored control beam.  相似文献   

14.
The flexural behavior of RC T-beams strengthened with prestressed near-surface-mounted (NSM) carbon fiber-reinforced-polymer (CFRP) reinforcement was investigated. The specific objective was to study the effect of partial unbonding of the CFRP reinforcement on the beam flexural behavior to increase the deformability. A total of eight RC T-beams were tested under four-point monotonic loading. The main variables were the level of prestressing force in the CFRP bars and the unbonded length at the midspan of the beam. The test results showed that all of the prestressed strengthened beams effectively improved the ultimate load-carrying capacity and the serviceability performance compared to the unstrengthened beam. The partially bonded prestressed beams exhibited an enhancement of the deformability compared to the fully bonded beams while minimizing the reduction of the load-carrying capacity. Partial unbonding was more effective to improve the deformability at higher levels of prestressing force. The general behavior of the partially bonded beams was reasonably well predicted by an analytical model developed previously by the writers.  相似文献   

15.
This paper presents the recent progress and achievement in the application of fiber-reinforced polymers (FRP) on strengthening reinforced/prestressed concrete beams subjected to fatigue loading. Although the performance of FRP-strengthened structures under monotonic loading has been intensively investigated, fatigue behavior is relatively less known to date. This paper summarizes most of the currently available literature, including the codes and design manuals, on reinforced/prestressed concrete beams externally strengthened with FRP. The review focuses specifically on the fatigue life as a function of the applied load range, bond behavior of externally bonded FRP, damage accumulation, crack propagation, size effects, residual strength, and failure modes. Research needs including considerations for design guidelines are presented.  相似文献   

16.
The paper aims to contribute to a better understanding and modeling of the shear behavior of reinforced-concrete (RC) beams strengthened with carbon fiber reinforced polymer (FRP) sheets. The study is based on an experimental program carried out on 11 beams with and without transverse steel reinforcement, and with different amounts of FRP shear strengthening. The test results provide some new insights into the complex failure mechanisms that characterize the ultimate shear capacity of RC members with transverse steel reinforcement and FRP sheets. After the discussion of the above topics, a new upper bound of the shear strength is introduced. It should be capable of taking into account how the cracking pattern in the web failing under shear is modified by the presence of FRP sheets, and how such a modified cracking pattern actually modifies the anchorage conditions of the sheets and their effective contribution to the ultimate shear strength of the beams.  相似文献   

17.
This paper explores a new hybrid fiber-reinforced polymer (FRP) sheet/ductile anchor system for rehabilitation of reinforced concrete (RC) beams. The advantages of the proposed strengthening method is that it overcomes the problem of low ductility that is associated with brittle failure mode in conventional methods of strengthening beams using epoxy-bonded FRP sheets. The proposed system leads to a ductile failure mode by triggering yielding to occur in a steel anchor system (steel links) rather than by rupture or debonding of FRP sheets, which is sudden in nature. Four half-scale RC T-beams were tested under four-point bending. Three retrofitted beams were strengthened using one layer of carbon FRP sheet. The results of the two beams that were strengthened with the new hybrid FRP sheet/ductile anchor system were compared with the results from the beam strengthened with conventional FRP bonding method and the control beam. The results show the effectiveness of the proposed strengthening system in increasing flexural capacity and ductility of RC beams.  相似文献   

18.
This paper presents the methods for predicting the short-term and time-dependent deflections of fully or partially prestressed concrete beams with fiber reinforced polymer (FRP) tendons under sustained bending moment and axial force. The age-adjusted effective modulus method is used to model the creep behavior in the concrete and the relaxation in the FRP prestressing tendons. A tension-stiffening model is proposed to evaluate the stiffness of the section after cracking. The analytical values are compared to the test results and it is found that the analytical values are in good agreement with the experimental results.  相似文献   

19.
The principal motivation of this study is to obtain a clear understanding of size effects for fiber-reinforced polymer (FRP) shear-strengthened beams. The experimental program consists of seven beams of various sizes grouped in three test series. One beam of each series is used as a benchmark and its behavior is compared with a beam strengthened with a U-shaped carbon FRP (CFRP) jacket. The third test series includes an additional beam strengthened with completely wrapped external CFRP sheets. The experimental results show that the effective axial strains of the CFRP sheets are higher in the smaller specimens. Moreover, with a larger beam size, one can expect less strain in the FRPs. A nonlinear finite-element numerical analysis is developed to model the behavior of the CFRP shear-strengthened beams. The numerical model is able to simulate the characteristics of the shear-strengthened beams, including the interfacial behavior between the concrete and the CFRP sheets. Three prediction models available in current design guidelines for computing the CFRP effective strain and shear contribution to the shear capacity of the CFRP shear-strengthened beams are compared with the experimental results.  相似文献   

20.
Use of carbon fiber reinforced polymers (CFRP) reinforcement for prestressing concrete structures introduces a promising solution for deterioration of concrete structures due to corrosion of steel reinforcements. Due to the low elastic modulus and limited strain at failure of CFRP reinforcement, partial prestressing could be the most appropriate approach to enhance deformability and reduce the cost in comparison to fully prestressed concrete structures. For members reinforced or prestressed with fiber reinforced polymers reinforcements, serviceability requirements may be the governing criteria for the design; therefore, deflection under service loading conditions should be well defined. This paper introduces simplified methods to calculate the deflection of beams prestressed by CFRP reinforcement under short-term and repeated loading. It also examines the applicability of current approaches available to calculate the deflection. Based on an experimental program undertaken at the University of Manitoba, bond factors are introduced to account for tension stiffening of concrete beams prestressed by CFRP. A procedure to determine the location of the centroidal axis of cracked prestressed sections is also proposed. The proposed methods for deflection calculation are calibrated using the results obtained from different experimental programs. Design guidelines are proposed to predict the deflection of beams partially prestressed by CFRP reinforcement.  相似文献   