 共查询到20条相似文献,搜索用时 276 毫秒
1.
Solar XXI building is a low energy office building where passive and active solar strategies have been applied to reduce the use of energy for heating, cooling and lighting, combining also an extensive photovoltaic façade for electricity production. Solar XXI opened in 2006 and is considered a high efficient building, close to a net zero energy building (NZEB), where the difference between the energy consumed and that produced is 1/10th of the energy consumed by a Portuguese standard new office building. Its design includes many energy efficiency concepts, such as a high insulated envelope, south sun exposure, windows external shading, photovoltaic panels heat recovery, ground-cooling system, daylighting, stack effect and cross ventilation. The solar gains of the windows and the effectiveness of shading devices were evaluated in order to correlate solar radiation, external and indoor air temperatures. It was also verified that amplitude-dampening of ground-cooled air ranged between 5 and 8 °C, following the trend of the analytical solution for heat diffusion of a cylindrical air/soil heat-exchanger.  相似文献   

2.
This paper presents a comprehensive analysis to study the balance between daylighting benefits and energy requirements (control of solar gains) in perimeter private office spaces with interior roller shades taking into account glazing properties, shading properties and control together with window size, climate and orientation in an integrated daylighting and thermal manner. Daylight autonomy and useful daylight illuminances were computed as a function of façade design parameters. A thermal simulation module using the explicit finite difference thermal network approach runs at the same time step and calculates heating, cooling and lighting source energy consumption as well as surface temperatures and operative temperature. Based on the daylighting results, lighting internal gains (continuous dimming control) are simultaneously input to the thermal module. The model also considers the air in the gap between shade and interior glass as a separate thermal node.Detailed results for Chicago and Los Angeles showed that windows with visible transmittance higher than 50% have the ability to allow enough daylight into the space for all locations and orientations for window-to-wall ratios higher than 50%. Useful daylight illuminances between 500 and 1000 lux were considered in detail – it was found that this index can be maximized for specific window-to-wall ratios and that depends on the glazing properties and fabric properties for each orientation. Moreover, the complex interactions of the studied parameters and their impact on the heating, cooling and lighting energy performance revealed an interesting result: windows occupying 30–50% of the façade can actually result in lower total energy consumption for most cases with automated shading. This illustration of daylighting benefits can be realized only if the integration of daylighting and thermal climate-based analysis is modeled efficiently and depends on glazing and shading properties and control. Finally, best designs for each orientation and location were pointed out based on both daylighting and thermal results.  相似文献   

3.
Old buildings refurbishment is essential for the global improvement of building energy indicators. Within this context, the paper focuses on the energy savings that may occur when using electrochromic (EC) windows, an interesting emerging technology alternative to shading devices to control solar gain in buildings located in Mediterranean climates. The EC windows technology is briefly presented and the optical properties adjustments of the glasses are discussed according to the operated range. The EC window dynamic behavior and the different control strategies are modeled and implemented in the ESP-r building simulation program. The EC window impact in the energy needs for heating and cooling is studied, considering different ambient parameters (exterior dry bulb temperature, interior dry bulb temperature and incident radiation) and set points for the EC control. A comparison of several windows solutions (single, double-glazing and EC windows), the type of building, internal gains from occupancy, lighting and equipment and the orientation of windows are considered for discussion through the analysis of the energy needs for heating and cooling. It is concluded that for this climate the best positive results are obtained when the EC are used in the west façade. For the south façade the results show no significant advantages in using EC windows.  相似文献   

4.
The micro-light guiding shade is a device that acts to both shade the façade from direct sunlight and distribute daylight deep into sub-tropical buildings. The device was created in response to the need for daylighting technologies that can utilise direct sunlight while maintaining visual and thermal comfort in sub-tropical buildings. The created device has the form of a fixed panel with similar thickness and outward appearance as existing shades, yet performs the dual purposes of shading and light redirection.Experiments and computer lighting simulations were performed to assess the device’s performance in terms of effectiveness, efficiency, implementation, cost and construction issues. Experimental results show that the device provides favourable illumination deep within a room, while reducing glare for room occupants. Computer simulations compare favourably with experimental measurements, and have been used to find the optimal configuration of the panels in various situations. Installation of the device on high rise commercial buildings will reduce reliance on artificial lighting while improving the visual performance of office workers.  相似文献   

5.
The façade design is and should be considered a central issue in the design of energy-efficient buildings. That is why dynamic façade components are increasingly used to adapt to both internal and external impacts, and to cope with a reduction in energy consumption and an increase in occupant comfort. To gain a complete picture of any façade’s performance and subsequently carry out a reasonable benchmarking of various façade alternatives, the total energy consumption and indoor environment need to be considered simultaneously. We quantified the potential of dynamic solar shading façade components by using integrated simulations that took energy demand, the indoor air quality, the amount of daylight available, and visual comfort into consideration. Three types of façades were investigated (without solar shading, with fixed solar shading, and with dynamic solar shading), and we simulated them with various window heights and orientations. Their performance was evaluated on the basis of the building’s total energy demand, its energy demand for heating, cooling and lighting, and also its daylight factors. Simulation results comparing the three façade alternatives show potential for significant energy reduction, but greater differences and conflicting tendencies were revealed when the energy needed for heating, cooling and artificial lighting were considered separately. Moreover, the use of dynamic solar shading dramatically improved the amount of daylight available compared to fixed solar shading, which emphasises the need for dynamic and integrated simulations early in the design process to facilitate informed design decisions about the façade.  相似文献   

6.
The current research study presents the development of the upgrade module consisting of a timber frame structure with the optimal glazing size in the east-, south- and west-oriented façades for the purpose of energy-efficient refurbishment of the existing energy-inefficient buildings. Such construction module could open the way to simple installation onto the existing residential, public or office buildings of various shapes and ensure better energy performance of the refurbished buildings. The optimal glazing size of the east-, south- and west-oriented façades of the module with the optimal shape is determined by the glazing-to-wall area ratio where the sum total of the annual energy need for heating and cooling of the module is minimal. The sum of the annual energy is defined through an extensive parametric numerical analysis including variations regarding the module’s aspect ratio, the thermal transmittance of its envelope and the glazing size in its east-, south- and west-oriented façades. A parametric analysis carried out in the previously described manner leads to analytic functional dependence between the energy consumption and the module’s design parameters. It is therefore possible to make a fairly simple preliminary estimate of the annual energy need, in addition to defining the optimal floor plan shape of the module along with the optimal proportion of glazing in its east-, south- and west-oriented façades. The optimal proportion of glazing varies from 24 to 91% in the south-oriented façade, from 7 to 43% in the east and from 9 to 55% in the west façade, at the thermal transmittance of the thermal envelope 0.100 W/(m2 K). The variation in the optimal glazing proportion of the module with the thermal transmittance of the thermal envelope 0.165 W/(m2 K) ranges from 14 to 85% in the east, from 28 to 97% in the south and from 16 to 68% in the west-oriented façade. The presented research study permits a choice of the optimal module design with respect to baseline characteristics of the existing building and allows for a more systematic as well as energy-efficient refurbishment process.  相似文献   

7.
This paper develops an overall methodology for investigating the thermal and power behaviors of semi-transparent single-glazed photovoltaic window for office buildings in Hong Kong. In order to estimate its overall energy performance, this study is conducted in terms of total heat gain, output power and daylight illuminance. Three simulation models are established, including one-dimensional transient heat transfer model, power generation model and indoor daylight illuminance model. A typical office room reference is chosen as case study, and the weather data from 2003 to 2007 from the Hong Kong Observatory are used as the simulation inputs. By incorporating the simulation results, the overall energy performance can be evaluated in terms of electricity benefits corresponding to five orientations of the studied typical office. The priority of office orientation considering overall energy performance is: south-east, south, east, south-west and west. The findings show that thermal performance is the primary consideration of energy saving in the entire system whereas electricity consumption of artificial lighting is the secondary one. The overall annual electricity benefits are about 900 kWh and 1300 kWh for water-cooled and air-cooled air-conditioning systems respectively. The application of semi-transparent PV glazed window can not only produce clean energy, but also reduce building energy use by reducing the cooling load and electrical lighting requirements, which definitely benefits our environmental and economic aspects.  相似文献   

8.
Natural daylight is an inexpensive and very efficient light source provided that the amount of daylight entering a building is controlled according to demand. In commercial buildings electricity for lighting can be cut by 50-75% using daylighting design techniques in combination with efficient artificial lighting. New lighting control technologies and advanced computer simulation tools lo optimize large buildings makes it possible to exploit these energy savings.

Daylight is a very efficient light source, providing more light for less input of thermal energy than any other artificial light source. Efficient shading systems are now emerging systems that can control the admission of daylight to the room according to requirement, and avoid overheating. Some of these systems, such as reflective light shelves, will also contribute to a better distribution of the daylight available by redistributing some daylight to the back of the room. However, more work is needed to develop and test such combined daylight and shading systems.

The use of daylight to reduce electric lighting must be seen as an integrated part of the overall energy optimization of the building. An efficient control of the use of daylight and artificial lighting will not only reduce electricity use for lighting. Additionally, the use of electricity for ventilation and cooling can be reduced also, because the internal heat gains provocating these electricity uses are reduced. This calls for an integrated design approach to the overall energy design of the building, involving the architect and the engineer from the very beginning of the design phase.

Visual comfort of office buildings receives increasing attention, partially because of the VDU's (Visual Display Units) of the computers, that are now almost standard equipment of every work place. The performance requirements for both daylighting systems and artificial lighting systems have been sharpened, and the attention to this fact is crucial in future development of lighting systems.  相似文献   

9.
Multifunctional façade components have nowadays become a significant research topic as a step towards developing energy-efficient buildings. This paper presents the performance evaluation of an experimental setup of a real fully decentralized façade-integrated photovoltaic (PV) system installed in a prototype façade, for direct DC power use. The goal of this evaluation was to test the system's ability to fulfill a pre-designed daily electrical load of 925Wh corresponding to a three-people office space under 100% decentralization. This was achieved by studying the operation under different weather conditions and the impact of the system design and components on its overall output. The evaluation of both the actual and theoretical system outputs indicates poor actual system performance in terms of low energy yield and unacceptable load fulfillment factor, which did not exceed 0.95. At the same time it revealed underutilized system potential which could be exploited theoretically with a proper system configuration. The results in this paper conclude that decentralized façade integrated PV systems can completely satisfy their designated applications if properly-designed and implemented, and provides a methodology which could be used in designing similar systems. Satisfactory fulfillment is shown to be achieved by having 30% additional PV and 9 times bigger storage capacities in this system.  相似文献   

10.
In the design of very well-insulated homes, there is a need for a more nuanced design that takes into account winter and summer conditions. In this paper, we compare a traditional design for a typical Danish single-family house with large glazing areas oriented towards the south and smaller glazing areas towards the north, and a design with an even window distribution where the glazing-to-floor ratio is the same for each room. We found that the use of solar gains through south-oriented windows is not as important as is traditionally believed because, in well-insulated homes, space heating demand is not reduced much by having larger south-facing windows. Furthermore, we found that there is a g-value above which the additional solar gains through south-oriented windows do not help reduce space heating demand, and it becomes important to use solar shading or glazing with solar-control coating as a cheaper alternative to reduce overheating. Maximum window sizes from an overheating perspective were identified that are larger than the optimal window sizes for space heating demand. However, we show that the difference in space heating demand with optimal window size and with larger window sizes is small, so it is up to the building owner to decide whether or not he wants larger glazing areas to allow for more daylight. And windows can be positioned in the façade with considerable architectural freedom. However, we do recommend an even distribution of the glazing-to-floor ratio, because this generally provides an improved thermal indoor environment in south-oriented rooms and will ensure a better daylight level especially in north-oriented rooms. We also show that the optimal window size is influenced by thermal zone configuration and that there is a need for models in which a difference is made between zones with direct and with non-direct solar gains.  相似文献   

11.
Air conditioning systems in commercial buildings in Brazil are responsible for about 70% share of their energy consumption. According to BEN 2009 (The Brazilian Energy Balance), energy consumption in the residential, commercial and public sectors, where most buildings are found, represents 9.3% of the final energy consumption in Brazil. This paper aims to examine design factors that could contribute to greater reductions of electric energy consumption in commercial buildings, with emphasis on air conditioning. Simulations were carried out using shades and different types of glass, walls, flooring and roofing. The VisualDOE 2.61 was used as a simulation tool for calculating energy consumption of the analyzed building. This paper shows that the energy performance of the building is considerably influenced by the façade protection and shows, through tables, the impact that decisions related to the top-level and façades have on the energy consumption of the building. The authors concluded that the results confirm the importance of taking energy use into account in the very first design stages of the project, since appropriate choices of types of glass, external shading and envelope materials have a significant impact on energy consumption.  相似文献   

12.
The current study investigates a holistically developed solar energy system combined with a ground-sourced heat pump system for stand-alone usage to produce power, heat, and cooling along with domestic hot water for residential buildings. An integrated system is proposed where three types of building-integrated photovoltaic plant orientation are considered and integrated with a vertical-oriented ground-sourced heat pump system as well as an anion exchange membrane electrolyser for hydrogen-based energy storage along with proton exchange membrane fuel cells. The ground-sourced heat pump system covers the heating requirements and exploits the available thermal energy under the ground. Hydrogen subsystem enables the integrated system to be used anytime by compensating the peak periods with stored hydrogen via fuel cell and exploiting the excess energy to produce hydrogen via electrolyser. The photovoltaic plant orientations are extensively designed by considering geometries of three different applications, namely, rooftop photovoltaic, building-integrated photovoltaic façade and photovoltaic canopy. The shading and geometrical losses of photovoltaic applications are extensively identified and considered. In addition, the openly available high-rise building load profiles are obtained from the OpenEI network and are modified accordingly to utilize in the current study. The building requirements are considered for 8760 h annually with meteorological data and energy usage characteristics of the selected regions. The integrated system is assessed via thermodynamic-based approach from energy and exergy points of views. In order to increase generality, the proposed building energy system is analyzed for five different cities around the globe. The obtained results show that a 20-floor building with approximately 62,680 m2 residential area needs between 550 kWp and 1550 kWp of a photovoltaic plant in five different cities. For Ottawa, Canada, the overall energy and exergy efficiencies are found as 18.76% and 10.49%, respectively, in a typical meteorological year. For the city of Istanbul in Turkey, a 20-floor building is found to be self-sufficient by only using the building's surface area with a 495 kWp BIPV façade and a 90 kWp rooftop PV.  相似文献   

13.
Energy efficient buildings need to take advantage of any renewable energy available. An opaque ventilated façade (OVF) is a kind of façade that absorbs solar energy and transfers it to the ventilation system. This way, the sensible ventilation load of the heating system can be reduced in the winter season. The energy saving of this system depends strongly on the weather variables, mainly solar radiation on the façade, ambient temperature and wind speed. In order to find the most convenient locations where the best OVF efficiency can be obtained, its performance has to be studied along a complete season. For this purpose in this study a sensitivity analysis with the most important weather variables was carried out and the energy saving values in 12 locations in Spain in the winter were evaluated using a numerical model previously validated with experimental data. The results showed that although the most influential weather variable was solar radiation, a combination of high temperatures and low wind speeds can also lead to important energy saving values. It was found that the most convenient locations for installing an OVF were those with low and medium winter severity climates, namely, in the southern and coastal regions of Spain (zones A3, B3, B4, C3 and C4).  相似文献   

14.
A Trombe wall that uses a phase change material (PCM) as the heat storage medium is usually called a PCM Trombe wall or PCM wall. A research project was conducted to investigate the performance of coupled novel triple glass (NTG) and PCM wall, which is simply called PCM wall in this paper, as a solar space heater. The south façade of a test room was constructed using PCM walls. Rubitherm® GR35 and GR41 were incorporated into the plaster of the walls as PCM. The ratio of the solar energy gain provided by the PCM walls to the heat load of the test room per month varied from 4% to 70%; daily overall efficiency of the PCM walls varied from 20% to 36%; and solar transmittance of the NTG varied from 0.45 to 0.55 during the heating period. The overall efficiency of the PCM wall including GR35 was higher than that of the PCM wall including GR41.  相似文献   

15.
In this study, a theoretical ventilated photovoltaic (PV) façade, which functions as a pre-heating device in winter and a natural ventilation system in summer and reduces PV module temperatures, was analysed. The interrelationship between an optimum proportion of transparent window (and an opaque PV module) to the total façade area, and the variables relevant to the energy performance was assessed. The design parameters under consideration have been categorised according to climate, building characteristics, façade configurations and PV system elements. One outcome of this investigation is a new index, effectiveness of a PV Façade (PVEF), that has been developed to evaluate the overall energy performance of a PV façade with regard to the proportion of useful daylight that may displace the use of electric lighting, and the electricity generated by the PV modules to the heating and cooling energy consumption within a building. In conclusion, the electricity generation and the factors, affecting the ventilation performance of a ventilated PV façade, have been presented.  相似文献   

16.
17.
Buildings in most countries around the world require large amounts of energy both for cooling and heating. In fact cooling loads due to solar gains represent about half of global cooling loads for residential as well as non-residential buildings. While solar gains through windows contribute largely to these loads, any method of decreasing these gains through shading should be applied with caution, since a balance is required; decreasing cooling loads by shading may increase heating loads drastically and vice versa. So the overall energy requirements both for heating and cooling should be considered. With this in mind a study was done on the thermal performance of a building by TRNSYS simulation, and a shading model for windows was incorporated in it. The shading devices adopted were external fixed horizontal louvers with different slat lengths and tilts. The study was conducted for four different cities in Italy. The optimization of the shading devices was done with respect to primary energy loads for the whole year, and the optimum design was found to depend on location and weather conditions. It was also found that shading factor varies with time of day and is different for summer and winter. For example, for Milan it was found that 70% of gain is cut off in summer, while only 40% is cut off in winter by using optimum shading, which is desirable.  相似文献   

18.
This paper presents an experimental and simulation study for quantifying the daylighting performance of bottom-up roller shades installed in office spaces. The bottom-up shade is a motorized roller shade that opens from top to bottom operating in the opposite direction of a conventional roller shade, so as to cover the bottom part of the window, while allowing daylight to enter from the top part of the window, reaching deeper into the room. A daylighting simulation model, validated with full-scale experiments, was developed in order to establish correlations between the shade position, outdoor illuminance and work plane illuminance for different outdoor conditions. Then, a shading control algorithm was developed for application in any location and orientation. The validated model was employed for a sensitivity analysis of the impact of shade optical properties and control on the potential energy savings due to the use of daylighting. The results showed that Daylight Autonomy for the bottom-up shade is 8–58% higher compared to a conventional roller shade, with a difference of 46% further away from the façade, where the use of electric lighting is needed most of the time. The potential reduction in energy consumption for lighting is 21–41%.  相似文献   

19.
In subtropical Hong Kong, solar heat gain via glazing contributes to a significant proportion of the building envelope cooling load. The principal fenestration design includes eliminating direct sunlight and reducing cooling requirements. Daylighting is an effective approach to allow a flexible building façade design strategy, and to enhance an energy-efficient and green building development. This paper studies the lighting and cooling energy performances for a fully air-conditioned open-plan office when solar control films together with daylight-linked lighting controls are being used. Measurements were undertaken at two stages including the electricity expenditures for the office using photoelectric dimming controls only (first stage) and together with the solar control film coatings on the windows (second stage). Electric lighting and cooling energy consumption, transmitted daylight illuminance and solar radiation were systematically recorded and analysed. The measured data were also used for conducting and validating the building energy simulations. The findings showed that the solar film coatings coupled with lighting dimming controls cut down 21.2% electric lighting and 6.9% cooling energy consumption for the open-plan office.  相似文献   

20.
Solar energy conversion systems and daylighting schemes are important building energy strategies to produce clean energy, reduce the peak electrical and cooling demands and save the building electricity expenditures. A semi-transparent photovoltaic (PV) is a building component generating electricity via PV modules and allowing daylight entering into the interior spaces to facilitate daylighting designs. This paper studies the thermal and visual properties, energy performance and financial issue of such solar facades. Data measurements including solar irradiance, daylight illuminance and output power for a semi-transparent PV panel were undertaken. Using the recorded results, essential parameters pertaining to the power generation, thermal and optical characteristics of the PV system were determined. Case studies based on a generic reference office building were conducted to elaborate the energy and cooling requirements, and the cost implications when the PV facades together with the daylight-linked lighting controls were being used. The findings showed that such an integrated system could produce electricity and cut down electric lighting and cooling energy requirements to benefit the environmental, energy and economic aspects.  相似文献   