首页 | 官方网站   微博 | 高级检索  
     


Regional cerebral blood flow,blood volume,oxygen extraction fraction,and oxygen utilization rate in normal volunteers measured by the autoradiographic technique and the single breath inhalation method
Authors:Jun Hatazawa  Hideaki Fujita  Iwao Kanno  Takao Satoh  Hidehiro Iida  Shuhichi Miura  Matsutaroh Murakami  Toshio Okudera  Atsushi Inugami  Toshihide Ogawa  Eku Shimosegawa  Kyo Noguchi  Yasuaki Shohji  Kazuo Uemura
Affiliation:1. Department of Radiology and Nuclear Medicine, Akita Research Institute of Brain and Blood Vessels, 6-10 Senshu-Kubota Machi, 010, Akita, Japan
Abstract:By means of a high resolution PET scanner, the regional cerebral blood flow (rCBF), cerebral blood volume (rCBV), oxygen extraction fraction (rOEF), and metabolic rate of oxygen (rCMRO2) for major cerebral gyri and deep brain structures were studied in eleven normal volunteers during an eye-covered and ear-unplugged resting condition. Regional CBF was measured by the auto-radiographic method after intravenous administration of H2 15O. Regional OEF and rCMRO2 were measured by the single inhalation of15O2. With MR T1-weighted images as an anatomical reference, thirteen major cerebral gyri, caudate nucleus, lentiform nucleus, thalamus, midbrain, pons, cerebellum and vermis were defined on the CMRO2 images. Values were read by using circular regions of interest 16 mm in diameter. The posterior part of the cingulate gyri had the highest rCBF and rCMRO2 values among brain structures, followed by the lentiform nucleus, the cerebellum, the caudate nucleus, and the thalamus. Parahippocampal gyri had the lowest rCBF and rCMRO2 values amongthe cortical gyri.RegionalOEFforthepontinenuclei (0.34 ± 0.04), the midbrain (0.35 ± 0.05), the parahippocampal gyri (0.35 ± 0.04 for the right and 0.37 ± 0.05 for the left), and the thalami (0.37 ± 0.05 for the right and 0.36 ± 0.04 for the left) were significantly lower than the mean OEF for the cerebral cortices (0.42 ± 0.04) (p < 0.05 or less). The global CBF and CMRO2 were consistent with those obtained by the Kety-Schmidt method. Although several limitations to the quantification derived from an inadequate spacial resolution remain unsolved, the performance of the present PET scanner and the method for the quantification employed provide regional estimates of brain circulation and oxygen metabolism more acurately than the PET system and the steady state method previously used.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号