首页 | 官方网站   微博 | 高级检索  
     


Monitoring Hepatocyte Dysfunction and Biliary Complication After Liver Transplantation Using Quantitative Hepatobiliary Scintigraphy
Authors:Si-Juan Zou  Dong Chen  Yan-Zhao Li  Dun-Feng Du  Zhi-Shui Chen  Xiao-Hua Zhu
Affiliation:From the Department of Nuclear Medicine (SJZ, YZL, XHZ); and Institute of Organ Transplantation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China (DC, DFD, ZSC).
Abstract:The significance of hepatobiliary scintigraphy (HBS) for hepatic graft function assessment was established mostly on retrospective studies and was not widely recognized due to the lack of quantitative data and variation in accuracy. This prospective study was performed to investigate the effectiveness of quantitative HBS for assessing hepatocyte dysfunction and biliary complication in liver transplant recipients.In 57 recipients who had undergone orthotopic liver transplantation, a total of 67 dynamic 99mTc-EHIDA scans were performed and quantitative parameters including the hepatocyte extraction fraction (HEF), time to maximum hepatic radioactivity (Tmax), and time for peak activity to decrease by 50% (T1/2) were calculated. The scintigraphic results based on the 3 parameters were compared against the final diagnosis. A ROC curve analysis was carried out to identify the cutoff value of Tmax for diagnosis of biliary stricture. Correlation between the parameters of postoperative HBS and conventional biochemical liver function indices were also analyzed.Quantitative 99mTc-EHIDA HBS had an overall sensitivity of 94.12% (16/17), specificity of 93.33% (42/45), and diagnostic accuracy of 93.55% (58/62) for detecting hepatocyte dysfunction and biliary complication in liver transplant recipients. The recommended cutoff value of Tmax for diagnosis of post-transplant biliary stricture was set at 15.75 min with a sensitivity of 100.0% and a specificity of 94.0%. The scintigraphic parameters (HEF, Tmax) were statistically significantly associated with the conventional liver function parameters.Quantitative 99mTc-EHIDA HBS offers a noninvasive imaging modality with high sensitivity and specificity to diagnose hepatocyte dysfunction as well as distinguish between patients with or without biliary stricture following liver transplantation. Furthermore, HEF and Tmax values obtained from dynamic HBS show good correlation with conventional liver function parameters.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号