首页 | 官方网站   微博 | 高级检索  
     

氟脱氧葡萄糖PET-CT常规及双时相显像检测食管癌术后复发转移的价值
引用本文:刘文健,孔莉,胡漫,于金明,韩安勤,马莉.氟脱氧葡萄糖PET-CT常规及双时相显像检测食管癌术后复发转移的价值[J].中华放射肿瘤学杂志,2011,20(1).
作者姓名:刘文健  孔莉  胡漫  于金明  韩安勤  马莉
作者单位:1. 泰山医学院附属医院肿瘤科
2. 山东大学医学院附属山东省肿瘤医院放疗科,济南,250117
3. 山东大学医学院附属山东省肿瘤医院核医学科,济南,250117
摘    要:目的 评价氟脱氧葡萄糖(FDG)PET-CT常规及双时相显像在监测食管癌术后复发转移中的应用价值.方法 回顾分析食管癌术后临床怀疑复发转移而行FDG PET-CT检查的48例患者临床资料,根据细胞学、病理或随访结果分析FDG PET-CT检查结果.两样本率比较采用Fisher's精确概率法检验.结果 48例患者中位随访21.5个月,34例出现复发转移,确定复发转移灶61处.FDG PET-CT常规显像对全部病灶诊断的敏感性、特异性和准确性分别为93.44%、74.29%和86.46%;对局部复发和区域淋巴结转移的敏感性、特异性、准确性分别为91.67%、57.14%、78.95%和90.48%、77.78%、84.62%.FDG PET-CT双时相显像诊断局部复发+区域淋巴结转移的敏感性、特异性、准确性均高于常规显像,分别为96.97%∶90.90%(P=0.613)、96.00%∶72.00%(P=0.049)、96.55%∶82.76%(P=0.029).结论 FDG PET-CT常规显像虽然检测食管癌术后局部复发及区域淋巴结转移的特异性和准确性较低,但仍是检测其术后复发转移的有效手段;双时相显像较常规显像更具优势,可有效提高检测的特异性及准确性.
Abstract:
Objective To evaluate the clinical value of regular and dual-time-point 18-fluorodeoxyglucose positron emission tomography-CT(FDG PET/CT)imaging for recurrence and metastasis in esophageal carcinoma(EC)after curative esophagectomy. Methods A retrospective study was done on 48 patients received curative esophagectomy, who underwent FDG PET/CT scans to detect doubtful recurrent or metastatic lesions. The diagnostic accuracy of FDG PET-CT was assessed with the help of pathological findings as well as clinical or follow-up data. Using Fisher's Exact Test from SPSS 11.5 to analyze the data.Results Of the 48 patients, after a median follow-up of 21.5 months, 61 sites of local and regional recurrence or metastasis were finally confirmed in 34 patients. The sensitivity, specificity and accuracy of regular FDG PET/CT imaging in detecting recurrence of all sites were 93.44%, 74.29% and 86.46%respectively. The specificity and accuracy of local recurrence and regional metastasis were 57.14% ,78.95% and 77.78% ,84.62%, respectively. The sensitivity, specificity and accuracy of dual-time-point FDG PET/ CT imaging in detecting local and regional recurrence(96.97% ,96.00% and 96.55%)were higher than those of regular FDG PET/CT(90.90%, 72.00% and 82.76%)and there were significant differences of specificity and accuracy(P = 0.049, P = 0.029). Conclusions Regular FDG PET/CT imaging is highly effective in detecting recurrence and metastasis in EC patients after curative esophagectomy despite the low specificity and accuracy. Dual-time-point FDG PET/CT imaging can elevate the specificity and accuracy.

关 键 词:食管肿瘤  肿瘤复发  局部  肿瘤转移  体层摄影术  发射型计算机  氟脱氧葡萄糖  双时相显像

Value of regular and dual-time-point FDG PET/CT imaging in detecting recurrence and metastasis after a curative esophagectomy in esophageal carcinoma
LIU Wen-jian,KONG Li,HU Man,YU Jin-ming,HAN An-qin,MA Li.Value of regular and dual-time-point FDG PET/CT imaging in detecting recurrence and metastasis after a curative esophagectomy in esophageal carcinoma[J].Chinese Journal of Radiation Oncology,2011,20(1).
Authors:LIU Wen-jian  KONG Li  HU Man  YU Jin-ming  HAN An-qin  MA Li
Abstract:Objective To evaluate the clinical value of regular and dual-time-point 18-fluorodeoxyglucose positron emission tomography-CT(FDG PET/CT)imaging for recurrence and metastasis in esophageal carcinoma(EC)after curative esophagectomy. Methods A retrospective study was done on 48 patients received curative esophagectomy, who underwent FDG PET/CT scans to detect doubtful recurrent or metastatic lesions. The diagnostic accuracy of FDG PET-CT was assessed with the help of pathological findings as well as clinical or follow-up data. Using Fisher's Exact Test from SPSS 11.5 to analyze the data.Results Of the 48 patients, after a median follow-up of 21.5 months, 61 sites of local and regional recurrence or metastasis were finally confirmed in 34 patients. The sensitivity, specificity and accuracy of regular FDG PET/CT imaging in detecting recurrence of all sites were 93.44%, 74.29% and 86.46%respectively. The specificity and accuracy of local recurrence and regional metastasis were 57.14% ,78.95% and 77.78% ,84.62%, respectively. The sensitivity, specificity and accuracy of dual-time-point FDG PET/ CT imaging in detecting local and regional recurrence(96.97% ,96.00% and 96.55%)were higher than those of regular FDG PET/CT(90.90%, 72.00% and 82.76%)and there were significant differences of specificity and accuracy(P = 0.049, P = 0.029). Conclusions Regular FDG PET/CT imaging is highly effective in detecting recurrence and metastasis in EC patients after curative esophagectomy despite the low specificity and accuracy. Dual-time-point FDG PET/CT imaging can elevate the specificity and accuracy.
Keywords:Esophageal neoplasms  Neoplasm recurrence  local  Neoplasm metastasis  Tomography  emission-computed  Fluoro-deoxyglucose  Dual-time-point imaging