实时三维超声在评价人工机械瓣功能中的应用
引用本文:杨军,项小苗,李东玉,郭亚军,刘守君.实时三维超声在评价人工机械瓣功能中的应用[J].中国医学影像技术,2008,24(5):680-682.
作者姓名:杨军  项小苗  李东玉  郭亚军  刘守君
作者单位:1. 中国医科大学附属盛京医院超声科,辽宁,沈阳,110004
2. 中国医科大学附属盛京医院心外科,辽宁,沈阳,110004
摘    要:目的在二维(2D)基础上应用三维实时超声心动图(RT-3DE),探讨RT-3DE在评价人工瓣功能方面的临床应用价值。方法应用PhilipsIE33型彩色多普勒超声诊断仪,对23例受检者进行了实时三维超声心动图检查,其中二尖瓣位18例,主动脉瓣位5例。结果23例人工瓣均获得较清晰的三维图像。20例人工瓣功能正常。3例功能异常,其中2例为人工瓣瓣周漏,另有1例为二尖瓣位人工瓣血栓导致梗阻。结论RT-3DE在2DE基础上,可获得更丰富的空间信息,可以对2DE做出有益的补充。

关 键 词:超声心动描记术  三维  心脏瓣膜  人工  实时三维超声心动图  评价  人工机械瓣  功能异常  临床应用  mechanical  assessment  echocardiography  有益的补充  空间信息  血栓  瓣周漏  三维图像  结果  主动脉瓣  二尖瓣  检查  受检者  多普勒超声诊断仪  彩色
文章编号:1003-3289(2008)05-0680-03
收稿时间:2007/11/2 0:00:00
修稿时间:2007年11月2日

Application of real-time three-dimensional echocardiography in the assessment of mechanical prosthetic valves
YANG Jun,XIANG Xiao-miao,LI Dong-yu,GUO Ya-jun and LIU Shou-jun.Application of real-time three-dimensional echocardiography in the assessment of mechanical prosthetic valves[J].Chinese Journal of Medical Imaging Technology,2008,24(5):680-682.
Authors:YANG Jun  XIANG Xiao-miao  LI Dong-yu  GUO Ya-jun and LIU Shou-jun
Affiliation:Department of Ultrasound, Shengjing Hospital, China Medical University, Shenyang 110004, China;Department of Ultrasound, Shengjing Hospital, China Medical University, Shenyang 110004, China;Department of Cardic Surgery, Shengjing Hospital, China Medical University, Shenyang 110004, China;Department of Ultrasound, Shengjing Hospital, China Medical University, Shenyang 110004, China;Department of Ultrasound, Shengjing Hospital, China Medical University, Shenyang 110004, China
Abstract:Objective To assess the clinical value of real-time three-dimensional echocardiography (RT-3DE) for evaluating the function of mechanical prosthetic valves. Methods Twenty-three patients, in which 18 patients with mitral valve prosthesis, and 5 with aortic valve prosthesis were examined with Philips IE33 to evaluate morphology and function of the mechanical protective valves. Results All the prosthetic valves of the twenty-three patients could be successfully observed by RT-3DE. Twenty of them worked normally. Other three cases were observed dysfunction, with perivalvular leakage in one case and obstruction of the prosthetic valve by thrombosis in another case. Conclusion As a new technique, RT-3DE can provide more spatial information than those of the 2DE in mechanical heart valve and offer the useful supplement to 2DE.
Keywords:Echocardiography  three-dimensional  Heart valve prosthesis