首页 | 官方网站   微博 | 高级检索  
     


Use of a Continuous Glucose Monitoring System in High-Risk Hospitalized Noncritically Ill Patients With Diabetes After Cardiac Surgery and During Their Transition of Care From the Intensive Care Unit During COVID-19: A Pilot Study
Authors:Ann T Sweeney  Samara Pena  Jeena Sandeep  Bryan Hernandez  Ye Chen  Janis L Breeze  Aysegul Bulut  Karen Feghali  Moaz Abdelrehim  Mohamed Abdelazeem  Padmavathi Srivoleti  Linda Salvucci  Susan Berry Cann  Catalina Norman
Affiliation:1. Department of Medicine, St Elizabeth’s Medical Center, Tufts University School of Medicine, Boston, Massachusetts;2. Tufts Clinical and Translational Science Institute, Tufts University and Tufts Medical Center, Boston, Massachusetts
Abstract:ObjectiveContinuous glucose monitoring (CGM) has demonstrated benefits in managing inpatient diabetes. We initiated this single-arm pilot feasibility study during the COVID-19 pandemic in 11 patients with diabetes to determine the feasibility and accuracy of real-time CGM in patients who underwent cardiac surgery and whose care was being transitioned from the intensive care unit.MethodsA Clarke error grid analysis was used to compare CGM and point-of-care measurements. The mean absolute relative difference (MARD) of the paired measurements was calculated to assess the accuracy of CGM for glucose measurements during the first 24 hours on CGM, the remaining time on CGM, and for different chronic kidney disease (CKD) strata.ResultsOverall MARD between point-of-care and CGM measurements was 14.80%. MARD for patients without CKD IV and V with an estimated glomerular filtration rate (eGFR) of ≥20 mL/min/1.73 m2 was 12.13%. Overall, 97% of the CGM values were within the no-risk zone of the Clarke error grid analysis. For the first 24 hours, a sensitivity analysis of the overall MARD for all patients and those with an eGFR of ≥20 mL/min/1.73 m2 was 15.42% ± 14.44% and 12.80% ± 7.85%, respectively. Beyond the first 24 hours, overall MARD for all patients and those with an eGFR of ≥20 mL/min/1.73 m2 was 14.54% ± 13.21% and 11.86% ± 7.64%, respectively.ConclusionCGM has shown great promise in optimizing inpatient diabetes management in the noncritical care setting and after the transition of care from the intensive care unit with high clinical reliability and accuracy. More studies are needed to further assess CGM in patients with advanced CKD.
Keywords:cardiac surgery  chronic kidney disease (CKD)  Clark error grid (CEG) analyses  continuous glucose monitoring (CGM)  mean absolute relative difference (MARD)  noncritically ill  ARD"}  {"#name":"keyword"  "$":{"id":"kwrd0050"}  "$$":[{"#name":"text"  "_":"absolute relative difference  CABG"}  {"#name":"keyword"  "$":{"id":"kwrd0060"}  "$$":[{"#name":"text"  "_":"coronary artery bypass grafting  CEG"}  {"#name":"keyword"  "$":{"id":"kwrd0070"}  "$$":[{"#name":"text"  "_":"Clarke error grid  CGM"}  {"#name":"keyword"  "$":{"id":"kwrd0080"}  "$$":[{"#name":"text"  "_":"continuous glucose monitoring  CKD"}  {"#name":"keyword"  "$":{"id":"kwrd0090"}  "$$":[{"#name":"text"  "_":"chronic kidney disease  eGFR"}  {"#name":"keyword"  "$":{"id":"kwrd0100"}  "$$":[{"#name":"text"  "_":"estimated glomerular filtration rate  ESRD"}  {"#name":"keyword"  "$":{"id":"kwrd0110"}  "$$":[{"#name":"text"  "_":"end-stage renal disease  ICU"}  {"#name":"keyword"  "$":{"id":"kwrd0120"}  "$$":[{"#name":"text"  "_":"intensive care unit  MARD"}  {"#name":"keyword"  "$":{"id":"kwrd0130"}  "$$":[{"#name":"text"  "_":"mean absolute relative difference  POC"}  {"#name":"keyword"  "$":{"id":"kwrd0140"}  "$$":[{"#name":"text"  "_":"point-of-care  TIR"}  {"#name":"keyword"  "$":{"id":"kwrd0150"}  "$$":[{"#name":"text"  "_":"time in range
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号