首页 | 官方网站   微博 | 高级检索  
     


A finite element model for the analysis of flexible tube Coriolis mass flow meter using first order shear deformation shell theory
Affiliation:2. Assistant Professor of Mechanical Engineering, SCT College of Engineering, Trivandrum, Kerala
Abstract:The numerical modelling of Coriolis Mass flow Meter (CFM) is essential for predicting its outcomes accurately in terms of sensitivity as well as exact mass flow rates. In the majority of mathematical and numerical modelling concerning the flexible structures, the authors neglect the dimensional and shape variation of the structure due to self-weight. The shell based on the First-order shear deformation shell theory (FSDST) is preferred in modelling shells compared to the beam model. The current work includes numerical modelling of CFM using eight noded isoparametric shell elements and twenty noded Acoustic fluid elements. The fluid energy describes as the potential, and the dynamic boundary condition is assumed utilising the displacement of structure and potential of the fluid. The fluid dynamic equation combining suitable numerical model, fluid-structure interaction module and cross-correlation technique helps to achieve the numerical modelling of CFM. The numerical model of CFM utilises the Newmark Beta method of numerical integration, and the response of two equidistant locations from the point of tube excitation is acquired. For the flexible tube conveying fluid, there exists sagging of tube due to the weight of tube and fluid. The Coriolis force and the external excitation force cause the fluid conveying tube to bend and twist, and as a result, the velocity responses picked from two equidistant points shows a difference in phase. The effect of sagging leads to a lower phase shift and time decay, and hence the sensitivity of the CFM is low for low pre-stretched flexible tubes. The pre-stretching of flexible tubes reduces the effect of sagging, facilitates to regain the cylindrical shape of the tube and increases the sensitivity of CFM. The result reveals that the shell element along with the three-dimensional acoustic fluid element provides the most accurate numerical model for the CFM and the change in sensitivity, as well as the change in mass flow measurements, can appropriately be analysed with the help of this numerical model. The amplitude of the velocity of the structure, measured from the two equidistant points, shows a difference. The severe variation in amplitude of velocity measured from two points is an implication of the out of plane deflection of the tube. For a CFM made up of metal tubes, the amplitude of velocity variation is minimal and ignored by the authors.
Keywords:CFM  Flexible tube  Pre-stretch  Beat  Natural frequency  Sensitivity
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号