首页 | 官方网站   微博 | 高级检索  
     


Experimental study to establish an evaluating method for the responsiveness of liquid flowmeters to transient flow rates
Affiliation:\\National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, 305-0861, Japan
Abstract:An aim of this research work is to establish an evaluation method concerning a responsiveness of flowmeters for a transient flow rate. To this end, reference flow metering systems for the transient flow are proposed in this paper. Because a behavior of the responsiveness depends on the type of flowmeter, evaluations using different parameters, such as response time to sudden rise and sudden fall in flow rate, response to the frequency and amplitude of flow pulsation, mean characteristic and so on are needed. To achieve a precise evaluation, two reference flow metering methods for transient flow rates are proposed in this paper. One is a high-response weighing method and the other is a velocity profile measurement method using the ultrasonic pulsed Doppler method (UPDM). Since the behaviors of the transient flow rate measured by both methods show good agreement, we conclude them to be useable as a reference flow metering system.
Keywords:Flow rate  Transient flow  Velocity profile  Pipe flow
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号