首页 | 官方网站   微博 | 高级检索  
     


Development and comparison of loop-mediated isothermal amplification and quantitative polymerase chain reaction assays for the detection of Mycoplasma bovis in milk
Authors:Sandra Appelt  Sharif S Aly  Karen Tonooka  Kathy Glenn  Zhengyao Xue  Terry W Lehenbauer  Maria L Marco
Affiliation:1. Department of Food Science and Technology, University of California, Davis 95616;2. Veterinary Medicine Teaching and Research Center, School of Veterinary Medicine, University of California Davis, Tulare 93274;3. Department of Population Health and Reproduction, School of Veterinary Medicine, University of California, Davis 95616
Abstract:Bovine mastitis is an economic burden for dairies worldwide. Mycoplasma species, and especially Mycoplasma bovis, are among the most important causative agents, and rapid, precise, and low-cost methods for Mycoplasma detection are urgently needed. For this purpose, loop-mediated isothermal amplification (LAMP) and quantitative PCR (qPCR) assays were developed and compared. The LAMP assay was designed and primer concentrations optimized to M. bovis oppD, encoding oligopeptide permease D. For qPCR, a Taqman assay (Applied Biosystems, Carlsbad, CA) targeting M. bovis gltX, encoding glutamate transfer RNA ligase, was optimized for primer concentration, annealing temperature, and DNA polymerase. Both assays were similarly sensitive, with a detection limit of approximately 104 to 105 M. bovis cells/mL. Both assays were also successful in confirming M. bovis identity in laboratory culture suspensions and in bovine milk. The LAMP and qPCR assays combined with the MoBio DNA extraction kit (MoBio Laboratories Inc., Carlsbad, CA) resulted in the correct detection of 13 out of 13 M. bovis isolates and 14 out of 16 M. bovis-positive milk samples collected from commercial dairies in California. When combined with the PrepMan Ultra reagent (Applied Biosystems), the qPCR assay resulted in confirming 21 out of 21 M. bovis-positive milk samples. Comparison of the assays to milk containing either Mycoplasma arginini, Mycoplasma bovigenitalium, Mycoplasma californicum, M. alkalescens, or Acholeplasma laidlawii or milk lacking any detectable Mycoplasma species or relatives resulted in 3 out of 17 (LAMP with MoBio), 1 out of 17 (qPCR with MoBio), and 2 out of 36 (qPCR with PrepMan Ultra) false positives. Overall, the qPCR assay was more robust than LAMP and could be used on DNA recovered from milk prepared with the PrepMan Ultra reagent, a method that does not include a DNA purification step. The use of this qPCR method enables M. bovis detection in bovine milk in 40 to 55 min, and therefore provides new opportunities to accelerate and simplify M. bovis detection in unpasteurized milk to reduce the incidence of M. bovis mastitis outbreaks.
Keywords:mastitis  milk  molecular detection
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号