首页 | 官方网站   微博 | 高级检索  
     

AP1000核电厂丧失正常给水稳压器防满水措施研究
引用本文:马柏松,郭宏恩.AP1000核电厂丧失正常给水稳压器防满水措施研究[J].核动力工程,2021,41(5):146-149.
作者姓名:马柏松  郭宏恩
摘    要:

关 键 词:AP1000  丧失正常给水  稳压器满水  堆顶放气  

Study on Measures to Prevent Pressurizer Overfill During Loss of Normal Feedwater for AP1000 NPP
Ma Baisong,Guo Hongen.Study on Measures to Prevent Pressurizer Overfill During Loss of Normal Feedwater for AP1000 NPP[J].Nuclear Power Engineering,2021,41(5):146-149.
Authors:Ma Baisong  Guo Hongen
Abstract:In an accident of loss of feedwater in an AP1000 plant, the pressurizer was filled with water for a series of improper operations, and the safety valves may not be qualified to re-close following multiple cycles of opening, which is not acceptable in Condition Ⅱ events. The paper analyzes the causes for the filling of water in the pressurizer in this event, that is, the instantaneous evaporation of coolant in the loop during the process of improper depressurization of RCS while the PRHR HX is with sufficient cooling capability. At this time, the water level in the pressurizer level cannot be decreased by opening the reactor vessel head vent valves for emergency letdown. Finally, the recommended measure is provided to prevent the filling of water in the pressurizer during loss of normal feedwater for AP1000 NPP. The RCS pressure should always be higher than the saturation pressure corresponding to the temperature of the hot legs to avoid the coolant evaporation.
Keywords:
点击此处可从《核动力工程》浏览原始摘要信息
点击此处可从《核动力工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号