γ-γ符合测量系统的新型前端读出电路研制
引用本文:颜俊伟,牛晓阳,柯凌云,杨海波,陈金达,杜成名,张秀玲,孙志朋,苏弘,孔洁.γ-γ符合测量系统的新型前端读出电路研制[J].原子能科学技术,2020,54(8):1500-1507.
作者姓名:颜俊伟  牛晓阳  柯凌云  杨海波  陈金达  杜成名  张秀玲  孙志朋  苏弘  孔洁
作者单位:中国科学院 近代物理研究所,甘肃 兰州730000;中国科学院大学 核科学与技术学院,北京100049
摘    要:研制了一种新型前端读出电路,用于重离子治癌装置中符合测量原型系统的研究和测试。电路主要包括能量链、时间链和数据处理单元。能量链由截止频率7 MHz的抗混叠滤波器和模数转换器(ADC)组成,形成波形采样电路;时间链由高速比较器构成的定时甄别电路和时间数字转换器(TDC)组成;数据处理单元基于现场可编程门阵列(FPGA)设计实现。电路的线性度优于0.8%,噪声小于0.8 mV(RMS)。配合LaBr3单晶体条测试,能量分辨为4.5%(FWHM),在与LYSO晶体阵列配合测试时,位置映射散点图清晰。该前端读出电路性能优于CAMAC系统,具有较好的实际应用前景。

关 键 词:符合测量系统    前端读出电路    现场可编程门阵列    能量分辨    位置分辨

Development of New Front-end Readout Electronics for γ-γ Coincidence Measurement System
YAN Junwei,NIU Xiaoyang,KE Lingyun,YANG Haibo,CHEN Jinda,DU Chengming,ZHANG Xiuling,SUN Zhipeng,SU Hong,KONG Jie.Development of New Front-end Readout Electronics for γ-γ Coincidence Measurement System[J].Atomic Energy Science and Technology,2020,54(8):1500-1507.
Authors:YAN Junwei  NIU Xiaoyang  KE Lingyun  YANG Haibo  CHEN Jinda  DU Chengming  ZHANG Xiuling  SUN Zhipeng  SU Hong  KONG Jie
Affiliation:Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China;School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:A new front-end readout electronics was developed, which was used for research and testing of the prototype coincidence measurement system in the heavy-ion cancer therapy device. The circuit mainly includes the energy measurement chain, time measurement chain and data processing unit. The energy measurement chain is composed of an anti-aliasing filter with a cut-off frequency of 7 MHz and an analog-to-digital converter (ADC), which forms a waveform sampling circuit. The time measurement chain is composed of a timing discrimination circuit formed by high-speed comparator and a time-to-digital converter (TDC). The data processing unit is designed and implemented based on a field programmable gate array (FPGA). The linearity of the circuit is better than 0.8% and the noise is less than 0.8 mV (RMS). It was tested coupled with a LaBr3 crystal strip, and the energy resolution is 4.5% (FWHM). Meanwhile, the test was performed with the LYSO crystal detection array, and the position map scatter plot is clear. The performance of the developed front-end readout circuit is superior to the CAMAC system and has a good practical application prospect.
Keywords:coincidence measurement system  front-end readout circuit  field programmable gate array  energy resolution  position resolution  
点击此处可从《原子能科学技术》浏览原始摘要信息
点击此处可从《原子能科学技术》下载全文