超临界水堆控制条件下扰动特性分析
引用本文:王晗丁,周涛,陈娟,樊昱楠.超临界水堆控制条件下扰动特性分析[J].原子能科学技术,2012,46(5):555-560.
作者姓名:王晗丁  周涛  陈娟  樊昱楠
作者单位:华北电力大学 ;核热工安全和标准化研究所,北京102206
摘    要:超临界水堆的一次通过循环设计不同于现有轻水堆,因此研究其扰动特性十分重要。在发生扰动后欲保持电站运行稳定,就要依靠控制系统调节达到稳定的状态。本文通过FORTRAN编制程序,研究以控制棒、汽轮机控制阀与反应堆冷却剂泵为控制方式的电站系统中,发生压力、温度等扰动时,反应堆内参数的变化。结果表明:给水流量的扰动不会对系统行为有很大影响,给水温度下降的扰动需较长时间才能达到稳定,压力设定值变化扰动时稳定所需的时间较短。

关 键 词:超临界水堆    控制方式    扰动    堆内特性

Perturbation Characteristics Analysis of Supercritical Cooling-Water Reactor Under Control Condition
WANG Han-ding , ZHOU Tao , CHEN Juan , FAN Yu-nan.Perturbation Characteristics Analysis of Supercritical Cooling-Water Reactor Under Control Condition[J].Atomic Energy Science and Technology,2012,46(5):555-560.
Authors:WANG Han-ding  ZHOU Tao  CHEN Juan  FAN Yu-nan
Affiliation:Institute of Nuclear Thermal-hydraulic Safety and Standardization, North China Electric Power University, Beijing 102206, China
Abstract:Supercritical cooling-water reactor is a once-through cycle plant system which is different from the existing light-water reactor,so it’s important to research its perturbation.In order to maintain power plant operation stable after perturbation,we must rely on control system regulate to achieve stable state.Using FORTRAN program to make code,when perturbation happens such as pressure set-point changes,feed-water temperature drop,reactor parameters changes with time were researched at the control rod,steam turbine control valves and the reactor coolant pumps as the plant control system.The results show that feedwater flowrate perturbation will not have a significant impact on system behavior.The feedwater temperature decrease perturbation need longer time to stabilize.Pressure setpoint change has shorter time to stabilize.
Keywords:supercritical cooling-water reactor  control mode  perturbation  reactor characteristics