底框砌体房屋转换层楼板厚度
引用本文:潘振新.底框砌体房屋转换层楼板厚度[J].工程抗震与加固改造,2004(1):30-33,17.
作者姓名:潘振新
作者单位:南京华顺房地产开发有限公司,南京,210042
摘    要:底框上部刚体结构在地震作用下,水平力要通过转换层楼板传给下部剪力墙等受力结构,因此楼板 要有充分的平面内抗弯刚度。合理的板厚非但能保证结构的整体稳定性,而且可避免结构的过剩强度储备或个 别薄弱环节。

关 键 词:转换层  当量厚度  网格加劲深梁

Thickness of Transition Floor Slabs for Masonry Buildings with Bottom Frames
Pan Zhenxin et al..Thickness of Transition Floor Slabs for Masonry Buildings with Bottom Frames[J].Earthquake Resistant Engineering and Retrofitting,2004(1):30-33,17.
Authors:Pan Zhenxin
Affiliation:Pan Zhenxin et al.
Abstract:Under the earthquake action, the horizontal forces induced by the rigid structure above the bottom frames are transmitted through the transition floor slabs to have adequate in - plane flexural rigidity. A reasonable slab thickness will not only ensure the integral stability of the structure, but also prevent excessive strength reserve or individual weak points.
Keywords:transition floor  equivalent thickness  grid stiffening deep beam