Fenton试剂氧化降解MC-LR影响因素分析 |
| |
作者姓名: | 陈志冉 祝丹丹 |
| |
作者单位: | 1. 黄河水利职业技术学院,河南,开封,475004 2. 郑州市自来水总公司,河南,郑州,450011 |
| |
摘 要: | 研究了Fenton法氧化降解MC-LR的影响因素,包括反应时间、pH、H2O2浓度、Fe2+/H2O2、Fe3+等.正交试验表明,各个因素的影响作用为H2O2浓度>Fe2+浓度>反应时间>pH.最佳试验条件为:H2O2浓度1.8 mmol/L、Fe2+/H2O2=1:18、初始pH=3、反应时间30 min、反应温度2...
|
关 键 词: | Fenton氧化法 MC-LR 氧化 正交试验 |
Influencing factors of MC-LR oxidation and degradation by Fenton method |
| |
Authors: | Chen Zhiran Zhu D an |
| |
Affiliation: | Chen Zhiran1,Zhu Dandan2(1.Yellow River Conservancy Technical Institute,Kaifeng 475004,China,2.Zhengzhou Water Supply Corporation,Zhengzhou 450011,China) |
| |
Abstract: | The influencing factors of MC-LR oxidation and degradation by Fenton method were investigated, including reaction time, pH, H202 concentration, Fe2+/H202 molar ratio, Fe3+ etc. The orthogonal experiment results showed that the capability of effect factors was H2 02 concentration 〉 Fe2+ concentration 〉 reaction time 〉 pH. The optimum conditions were: the H202 concentration of 1. 8 retool/L, 1 : 18 of Fe2+/H202, the initial pH value of 3, reaction time for 30 rain and the reaction temperature of (25 + 1 ) ℃. The removal rate could be 94.4% under these conditions when the initial concentration of the MC-LR was 2.0 μg / L. |
| |
Keywords: | MC-LR |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
|