首页 | 官方网站   微博 | 高级检索  
     

生物除铁除锰滤池对As(V)的去除效果研究
作者姓名:刘晓天  杨朋朋
作者单位:1. 天津市市政工程设计研究院,天津,300051
2. 潍坊市白浪河水库管理局,山东潍坊,261052
摘    要:采用人工配水模拟天然水体,考察了生物除铁除锰滤池对As(V)的去除性能。结果表明,当原水As(V)含量不高于200wg/L时,生物除铁除锰滤池对铁、锰的去除效果不受砷的影响,且As(V)去除率可达到95%以上,出水铁、锰及砷含量均满足标准限值要求;生物除铁除锰滤池对As(V)的去除主要发生在深度为0~660mm的滤层内;滤柱在反冲洗后,短时期内会出现砷、铁含量超标现象。

关 键 词:生物滤池    除铁  除锰

Removal effect of As ( V )by biological iron and manganese removal filter
Authors:Liu Xiaotian  Yang Pengpeng
Affiliation:1. Tianjin Municipal Engineering Design & Research Institute, Tianjin 300051, China ; 2. Weifang Bailanghe Reservoir Administration Bureau, Weifang 261052, China)
Abstract:The removal efficiency of As ( V ) by biological iron and manganese removal filter was investigated by adopting synthetic water distribution which could simulate natural water. The results showed that the removal effect of iron and manganese had no influence on As ( V ) by iron and manganese removal filter when the concentration of As ( V ) in water was no more than 200 p,g/L, and the removal rate of As ( V ) could reach above 95 % , the concentration of effluent iron, manganese and As could satisfy the requirement of standard limit value respectively. The removal effect of As ( V ) by biological iron and manganese removal filter mainly occurred within 0 to 660 mm depth of filter layer. The concentration of As and iron could exceed the standard in short period after backwash of filter cylinder.
Keywords:biological filter  As  iron removal  manganese removal
本文献已被 CNKI 维普 万方数据 等数据库收录!