首页 | 官方网站   微博 | 高级检索  
     

分布式供能系统消防安全设计的探讨
引用本文:朱鸣.分布式供能系统消防安全设计的探讨[J].上海节能,2005(6):77-79.
作者姓名:朱鸣
作者单位:朱鸣(上海市消防局建审处)
摘    要:通过对分布式供能系统设备本身及其布置所存在的危险性分析,分别对公共建筑中站房的设置位置、站房内应配备的安全设施、设备的安全性要求、供气管道的安全性要求、投入使用后的维护保养措施等给出了详细的论述。

关 键 词:消防  建筑  安全性  危险性

Discussion of fire control safety design of decentral cogeneration system
Zhu Ming.Discussion of fire control safety design of decentral cogeneration system[J].ShangHa Energy Conservation,2005(6):77-79.
Authors:Zhu Ming
Abstract:Through risk analysis of decentral co-generation system itself and its arrangement, these are separately discussed in details in this paper which include arrangement of station house in public building, what safety facility should be equipped with in station house, safety demand of equipment, safety demand of air-feed piping, maintaining and tending steps after devoting into operation.
Keywords:fire control  building  safety  risk