Magnetically induced vibration in a permanent-magnet brushless DC motor with symmetric pole-slot configuration |
| |
Authors: | Taeyong Yoon |
| |
Affiliation: | Hitachi Global Storage Technol. Inc., San Jose, CA, USA; |
| |
Abstract: | The paper reports a numerical and experimental study of magnetically induced vibration associated with rotor/stator eccentricity and imperfect magnetization for 8-pole 6-slot symmetric brushless dc (BLDC) motors. Magnetic forces and cogging torque are calculated for various slot angles by using the finite-element method (FEM). The results show that there is an optimal slot angle for minimum cogging torque, but this slot angle is not optimal for reducing magnetic forces. In the idle acoustics test, the motors with reduced magnetic forces show clear reduction at the expected frequencies while the motors with minimum cogging torque show no change at the cogging torque frequency, which implies unbalanced magnetic forces have greater effect on actual vibration of the spindle motor than cogging torque. The results show that the proper direction in motor design is to reduce unbalanced magnetic forces when both cogging torque and unbalanced magnetic forces are not achievable simultaneously. |
| |
Keywords: | |
|
|