首页 | 官方网站   微博 | 高级检索  
     


Composition of explosives by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
Authors:Wu Zhigang  Hendrickson Christopher L  Rodgers Ryan P  Marshall Alan G
Affiliation:Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University, Tallahassee 32310, USA.
Abstract:Commercial explosives are complex mixtures that contain not only the active explosive agent(s) but also a host of other organic and inorganic compounds. The ultrahigh mass resolving power (m/delta m50% >200,000) and mass accuracy (<1 ppm) of electrospray ionization Fourier transform ion cyclotron resonance (ESI FTICR) mass spectrometry allow for definitive identification of various species in TNT, RDX, and HMX. We are thereby able to correct prior misassignments of the elemental compositions of the most abundant negative ions from electrospray of RDX and HMX. Although the (known) active agents of many explosives may be identified by low-resolution MS or MS/MS, it is the other characteristic components (indigenous or artificial additives) whose presence and elemental composition can potentially identify the source of the product. ESI FTICR mass spectrometry of smokeless powder, TNT, and Powermite resolves and identifies numerous nonactive ingredients, many of which are recovered in a postblast residue. In contrast, the residue recovered from an explosion of military C4 yielded several species derived from RDX but virtually none from other ingredients.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号