首页 | 官方网站   微博 | 高级检索  
     

一管多机布置抽水蓄能电站非线性动力学建模与瞬态分析
引用本文:郭鹏程,郑小波,张浩,苟东明.一管多机布置抽水蓄能电站非线性动力学建模与瞬态分析[J].振动与冲击,2021(7):105-111.
作者姓名:郭鹏程  郑小波  张浩  苟东明
作者单位:西安理工大学水利水电学院;中国电建集团北京勘测设计研究院有限公司
基金项目:国家自然科学基金(51839010);陕西省重点研发计划(2017ZDXM-GY-081);陕西省教育厅服务地方专项计划(17JF019);陕西省联合研究基金(2019JLP-25)。
摘    要:一管多机布置抽水蓄能电站存在共用管段引水系统,其中共用管段的水力耦合相互作用是抽水蓄能电站系统动力学建模的关键。考虑共用管段水力系统耦合作用,将其分解成多个仅依赖于各子管段流量的单变量函数,通过结合水泵水轮机组动态特性,建立一管多机布置抽水蓄能电站非线性动力学模型。利用数值模拟探究了两机在额定工况并列运行时,一机突甩全负荷在不同导叶关闭规律且另一机组在调速器PID控制下,对各支管内机组流量、水头、出力动态特性的影响规律。仿真结果表明正常运行机组出力和流量动态响应具有正相关关系,机组水头动态响应与其流量和出力具有负相关关系,且波动周期相近。突甩负荷机组水头与流量的动态响应与导叶关闭规律密切相关,突甩负荷机组水头波动程度始终高于正常运行机组水头,且两机组水头波动周期相近;研究结果为探究一管多机抽水蓄能电站系统瞬态动力学建模与稳定性调控提供理论参考。

关 键 词:一管多机系统  抽水蓄能电站  非线性动力学  过渡过程

Nonlinear dynamic modeling and transient analysis of pumped storage power station with one tube and multi-unit
GUO Pengcheng,ZHENG Xiaobo,ZHANG Hao,GOU Dongming.Nonlinear dynamic modeling and transient analysis of pumped storage power station with one tube and multi-unit[J].Journal of Vibration and Shock,2021(7):105-111.
Authors:GUO Pengcheng  ZHENG Xiaobo  ZHANG Hao  GOU Dongming
Affiliation:(Institute of Water Resources and Hydro-Electric Engineering,Xi’an University of Technology,Xi’an 710048,China;Power China Beijing Engineering Corporation Limited,Beijing 100024,China)
Abstract:There is a shared pipe segment diversion system in a pumped storage power station with one pipe and multi-unit,hydraulic coupling interaction of the shared pipe segment is the key to the system dynamic modeling of pumped storage power station.Here,the coupling action of hydraulic system of the shared pipe segment was considered,and it was decomposed into several single variable functions only depending on the flow rate of each sub-pipe segment.Combining with dynamic characteristics of a pump-water turbine set,the non-linear dynamic model of a pumped storage power station with one pipe and multi-unit was established.When two units running in parallel under the rated condition,numerical simulation was used to explore effects of sudden full load rejection of one unit on dynamic characteristics of unit flow rate,water head and output inside each branch pipe under different guide blade closing rules and the other unit with speeder PID control.The simulation results showed that there is a positive correlation between dynamic responses of normal operation unit output and flow rate,dynamic response of unit water head has a negative correlation to its flow rate and output,and their fluctuation periods are close to each other;dynamic responses of water head and flow rate of the unit with sudden load rejection are closely related to closing rules of guide blade;fluctuation degree of water head of the unit with sudden load rejection is always higher than that of normal operation unit,and their fluctuation periods are similar;the study results provide a theoretical reference for exploring transient dynamic modeling and stability control of pumped storage power station systems with one tube and multi-unit.
Keywords:one tube and multi-unit system  pumped storage power station  nonlinear dynamics  transient process
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号